• 제목/요약/키워드: exposure criteria

검색결과 306건 처리시간 0.04초

어류에 미치는 인위적인 수중소음 영향과 피해기준에 대한 고찰 (Overview of anthropogenic underwater sound effects and sound exposure criteria on fishes)

  • 박지현;윤종락
    • 수산해양기술연구
    • /
    • 제53권1호
    • /
    • pp.19-40
    • /
    • 2017
  • A scientific and objective sound exposure criterion for underwater sound damage on fish has been required since there has been many disputes between an underwater sound maker and a fish damage receiver. The existing criteria are still incomplete scientifically owing to a degree of variability of underwater sounds, diversity of fish hearing sensitivity and damage types, etc. This study reviews existing studies on a hearing mechanism of fish species, manmade underwater sound characteristics and sound exposure assessment parameters, and recent sound exposure criteria. A governing equation for damage coverage estimation and damage coverage dependency on sound source level, ambient noise and transmission loss are also reviewed and interpreted based on sound exposure environments. The foreign and Korean (National Environmental Dispute Medication Commission) criteria are reviewed and compared based on scientific aspects. In addition, the deficit and limit of Korean criteria are presented. The objective of this study is to give a direction for related researches and legislation of sound exposure criteria on fish.

가습기살균제 환경노출 판정등급에 따른 개인 노출 특성 분포 - 4-1차와 4-2차 신청자를 중심으로 - (Individual Exposure Characteristics to Humidifier Disinfectant according to Exposure Classification Groups - Focusing on 4-1 and 4-2 Applicants -)

  • 이슬아;윤정교;옥정원;조은경;류현수;양원호;최윤형
    • 한국환경보건학회지
    • /
    • 제45권4호
    • /
    • pp.370-380
    • /
    • 2019
  • Objective: This study was performed to investigate the distribution of individual exposure characteristics according to an exposure assessment classification for humidifier disinfectant and to identify the factors that influence assessment classification. Methods: We examined the exposure characteristics of 4,482 subjects who applied for the 4-1 and 4-2 assessments of environmental exposure to humidifier disinfectant conducted by the Korea Environmental Industry & Technology Institute (KEITI). Environmental exposure assessment classification was assessed using the following seven criteria: 1) Distance from humidifier to face; 2) Spray direction; 3) Time used, daytime 4) Time used, during sleep; 5) Time used, cumulative; 6) Exposure intensity; and 7) Cumulative exposure level. Each criteria was then classified as 'high' or low'. When participants answered for more than four criteria, exposure assessment was determined as 'definite,' 'probable,' or 'possible' depending on the ratio of 'high' responses. If participants' responses were inconsistent, exposure assessment was listed as 'unlikely.' If participants answered for less than four criteria, exposure assessment was considered 'indeterminate.' Results: For the exposure assessment classes, definite was assigned to 38.5% (1,725 subjects), probable assigned to 32.9% (1,474 subjects), 25.0% (1,122 subjects) were assigned to as possible, unlikely assigned to 0.1% (3 subjects), and indeterminate assigned to 3.5% (158 subjects). Overall, participants who used 'Oxy Ssakssak New Gaseupgi Dangbun,' 'Aekyung Gaseupgi Mate,' 'Homeplus Gaseupgi Chungjungje,' and 'E-Mart Gaseupgi Salgyunje' totaled 2,996, 557, 176, and 162 subjects, respectively. There was a statistical difference in the type of humidifier disinfectant products between high-exposed and low-exposed participants. Based on the assessment criteria of humidifier disinfectant exposure, subjects were likely to be in the highly exposed classes (definite and probable) when the subjects were exposed 1) for more than ten hours per day and 2) for more than four hours at night 3) when the total cumulative exposure time was higher than the average, 4) when the direction of humidifier spray was toward the face, 5) when the respiratory position was less than 1 meter of distance from the humidifier, 6) when the concentration of indoor contaminants (ug/m3) was higher than the average exposure intensity, and 7) when overall exposure level ($ug/m3^*hr$) was higher than the average exposure level. Conclusion: This study suggests that each exposure assessment criteria was able to appropriately estimate cumulative exposure levels.

목재판넬 제조공정의 환경위험성평가 (Environmental Hazardous Assessment on Wood Panel Manufacturing Process)

  • 이수길;이내우
    • 한국안전학회지
    • /
    • 제22권3호
    • /
    • pp.13-21
    • /
    • 2007
  • Personal and static sampling for formaldehyde, wood dust and noise monitoring, in accordance to the equipment running on the day, were carried out throughout wood panel manufacturing process. Even though the exposure level of formaldehyde and wood dust were below than exposure criteria, but the personal protective equipment(PPE) for those should be worn to everyone in the process because of its potential characteristics like carcinogenicity. Also a few local air extraction system above the cutting, grinding sections and organic blending room should be required. Most of the exposures of noise exposure were exceeded permitted exposure criteria, in case of Hopper operators, exposed to maximally 94dB(A) as LAeq 8hr, therefore active controls like PPE, monitoring, isolation etc. are necessary. The main sources of noise were caused on compressed air of the machinery, radio sound and operation noise like running machines, conveying, cutting, sawing, moving vehicles, storing and so on. For the comparison of control criteria in each country, the permitted exposure standards for above hazardous materials and noise in Korea, ACGIH and Australia were discussed. We have recognized that the Korean criteria should be discussed urgently to give the right information to employee and modified, if it is necessary.

지하수 중 자연방사성물질의 위해성 관리에 대한 고찰 (International Trends in Risk Management of Groundwater Radionuclides)

  • 신동천;김예신;문지영;박화성;김진용;박선구
    • Environmental Analysis Health and Toxicology
    • /
    • 제17권4호
    • /
    • pp.273-284
    • /
    • 2002
  • At present, the health risks associated with the natural radionuclides of ground water have become a concern as potential social problems. However, there are no regulatory actions or control strategies for such risks. Therefore, we have investigated and discussed the risks and associated management strategies for radionuclides in other countries. US EPA has proposed MCL (300 pCi/L) and AMCL (4,000 pCi/L) for radon, and 30 ppb for uranium, 15 pCi/L for gross-alpha and 5 pCi/L for radium as final MCLs. Also, Canada, WHO and European countries have their inherent management levels. Finally, we suggested several criteria for setting guidelines in our countries including exposure related criteria such as geological distribution, occurrence, exposure probability distribution, exposure population and multimedia exposure assessment, acceptable risk, and cost -benefit analysis. The national-scale exposure and risk assessment, and economic analysis should be conducted for producing and aggregating the representative information on these criteria.

AN INTEGRATED APPROACH TO RISK-BASED POST-CLOSURE SAFETY EVALUATION OF COMPLEX RADIATION EXPOSURE SITUATIONS IN RADIOACTIVE WASTE DISPOSAL

  • Seo, Eun-Jin;Jeong, Chan-Woo;Sato, Seichi
    • Journal of Radiation Protection and Research
    • /
    • 제35권1호
    • /
    • pp.6-11
    • /
    • 2010
  • Embodying the safety of radioactive waste disposal requires the relevant safety criteria and the corresponding stylized methods to demonstrate its compliance with the criteria. This paper proposes a conceptual model of risk-based safety evaluation for integrating complex potential radiation exposure situations in radioactive waste disposal. For demonstrating compliance with a risk constraint, the approach deals with important exposure scenarios from the viewpoint of the receptor to estimate the resulting risk. For respective exposure situations, it considers the occurrence probabilities of the relevant exposure scenarios as their probability of giving rise to doses to estimate the total risk to a representative person by aggregating the respective risks. In this model, an exposure scenario is simply constructed with three components:radionuclide release, radionuclide migration and environment contamination, and interaction between the contaminated media and the receptor. A set of exposure scenarios and the representative person are established from reasonable combinations of the components, based on a balance of their occurrence probabilities and the consequences. In addition, the probability of an exposure scenario is estimated on the assumption that the initiating external factors influence release mechanisms and transport pathways, and its effect on the interaction between the environment and the receptor may be covered in terms of the representative person. This integrated approach enables a systematic risk assessment for complex exposure situations of radioactive waste disposal and facilitates the evaluation of compliance with risk constraints.

산업안전보건법상 허용기준 설정대상 유해인자 선정기준 마련에 관한 연구 (A Study on the Criteria for Selection of Permitted Standard Substances in the Occupational Safety and Health Act in Korea)

  • 이정현;함미란;이은정;이권섭;홍문기;변상훈
    • 한국산업보건학회지
    • /
    • 제27권2호
    • /
    • pp.97-104
    • /
    • 2017
  • Objectives: This study aims to suggest definitions in accordance with the purpose of the permissible limit system in order to suggest criteria for substances with permissible exposure limits and expanded candidate substances under the Occupational Safety and Health Act in Korea. Methods: The occupational safety and health related acts from six countries were researched, including from Korea. To understand the health hazards of substances with permissible exposure limits, health hazards were prioritized for 211 substances through working environment measurement on the basis of KOSHA's preceding research. Results: To suggest criteria for substances with permissible exposure limits and expanded candidate substances, definitions were suggested in accordance with the purpose of the permissible limit system. Based on the health hazard priorities for the working environment, selection criteria were identified. Conclusions: Three suggestions for substances with permissible exposure limits were proposed including substances where occurred serious health hazards such as carcinogenicity, germ cell mutagenicity, and reproductive toxicity to workers.

체형과 사회문화적 특성에 따른 속옷평가기준의 비교 연구 (Comparative Analysis of Underwear Evaluative Criteria according to Somatotypes and Socio-Cultural Characteristics)

  • 박선미
    • Human Ecology Research
    • /
    • 제51권5호
    • /
    • pp.563-571
    • /
    • 2013
  • This study aimed to investigate the effects of somatotypes and body-related variables such as body exposure and body satisfaction on underwear evaluative criteria. Usable questionnaires were obtained from a total of 250 male and female students in their 20s. The data were mainly analyzed by t-test, ANOVA and analysis of variance using SPSS ver. 21.0. The results of this study are as follows: First, differences between underwear and outerwear evaluative criteria were found. For example, size, comfort and washing were important for the underwear but design, brand and fashionability were meaningful for outerwear. Price, color, material, and sewing were important for both outerwear and underwear. Second, the groups divided by somatotypes, a thin person group, a moderate person group and a fat person group, showed no difference in underwear evaluative criteria. Members of all the somatotype groups evaluated underwear similarly. Third, the groups divided by body image distortion showed different evaluative criteria for underwear. The negative discordance group emphasized the importance of the practicality factor, but the positive discordance group stressed the significance of the symbolism factor. Finally, the groups divided by body exposure and body satisfaction showed different evaluative criteria for underwear, too. The effects of socio-cultural variables on the underwear evaluative criteria proved to be significant.

화재하중밀도를 고려한 건축물의 내화설계법에 관한 연구 (A Study on the Fire Resistance Design of Buildings Considering the Fire Load Energy Density)

  • 이평강;이용재;최인창;김회서
    • 한국화재소방학회논문지
    • /
    • 제17권2호
    • /
    • pp.10-16
    • /
    • 2003
  • 본 연구의 목적은 성능위주의 화재안전설계법에 따른 구획실 용도별 요구내화시간산정을 실시함으로써 현행 내화성능기준의 문제점도출 및 개선방향을 제시하는 것이다. 내화성능기준에 대한 검토를 위해 본 연구에서는 현재 국내의 시방규정에 의해 결정된 요구내화시간과 등가시간공식에 의해 산정된 화재노출상응시간과 비교하였고, 화재노출상응시간을 산정하기 위해 화재하중밀도, 환기계수, 구조재료의 열적특성 그리고 구획실 형상치수 등을 조사하였다.

정밀산업(TFT-LCD) 공장 내 노광장치의 대형 세대별 동강성 허용규제치 예측 및 평가에 관한 연구 (A Study on How to Predict and Evaluate the Dynamic Stiffness Criteria of Exposure Equipment in Precision Industrial Factory(TFT-LCD))

  • 백재호;전종균;박상곤
    • 반도체디스플레이기술학회지
    • /
    • 제10권4호
    • /
    • pp.15-20
    • /
    • 2011
  • The lithography system installed inside precision industry's (e.g. TFT-LCD) production factories are increasing in size, thereby increasing its dynamic load along with it. Such condition causes vibration within the area where the system is installed, which then negatively affects the production line to produce defective products. To prevent this type of situation, the facilities should adopt dynamic design that considers the lithography system's dynamic load. This study predicts the maximum value allowed for dynamic stiffness (which is a ratio of vibration response against a single unit of the dynamic load) of the lithography system and explains the result of its application on actual structures inside the facilities.

Verification of Harmonization of Dose Assessment Results According to Internal Exposure Scenarios

  • Kim, Bong-Gi;Ha, Wi-Ho;Kwon, Tae-Eun;Lee, Jun-Ho;Jung, Kyu-Hwan
    • Journal of Radiation Protection and Research
    • /
    • 제43권4호
    • /
    • pp.143-153
    • /
    • 2018
  • Background: The determination of the amount of radionuclides and internal dose for the worker who may have intake of radionuclides results in a variation due to uncertainty of measurement data and ingestion information. As a result of this, it is possible that for the same internal exposure scenario assessors could make considerably different estimation of internal dose. In order to reduce this difference, internal exposure scenarios for nuclear facilities were developed, and intercomparison were made to determine the harmonization of dose assessment results among the assessors. Materials and Methods: Seven cases on internal exposures incidents that have occurred or may occur were prepared by referring to the intercomparison excercise scenario that NRC and IAEA have carried out. Based on this, 16 nuclear facilities concerned with internal exposure in Korea were asked to evaluate the scenarios. Each result was statistically determined according to the harmonization discrimination criteria developed by IDEAS/IAEA. Results and Discussion: The results were evaluated as having no outliers in all 7 cases. However, the distribution of the results was spread by various causes. They can be divided into two wide categories. The first one is the distribution of the results according to the assumption of the intake factors and the evaluation factors. The second one is distribution due to misapplication of calculation method and factors related to internal exposure. Conclusion: In order to satisfy the harmonization criteria and accuracy of the internal exposure dose evaluation, it is necessary that exact guidelines should be set on low dose, and various intercomparison cases also be needed including high dose exposure as well as the specialized education. The aim of the blind test is to make harmonization evaluation, but it will also contribute to securing the expertise and high quality of dose evaluation data through the discussion among the participants.