• 제목/요약/키워드: exposure correction

검색결과 116건 처리시간 0.032초

Celiac Disease in South Jordan

  • Altamimi, Eyad
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제20권4호
    • /
    • pp.222-226
    • /
    • 2017
  • Purpose: Celiac disease, an autoimmune enteropathy triggered by exposure to gluten, is not uncommon in South Jordan. However, its prevalence is underestimated due to lack of physician awareness of the diversity of disease presentation. The clinical spectrum includes classic gastrointestinal manifestations, as well as rickets, iron-deficiency anemia, short stature, elevated liver enzymes, and edema. Our goal was to evaluate celiac disease presentation in clinically diagnosed children. Methods: Retrospective study included all children diagnosed with celiac disease between September 2009 and September 2015. Hospital charts were reviewed. Demographic data, clinical characteristics, and follow-up were recorded. Results: Thirty-five children were diagnosed with celiac disease during the study period. Mean age${\pm}$standard deviation was $6.7{\pm}3.8$ years (range, 2.0-14 years). There were 17 (48.6%) female patients. The average duration between onset of symptoms and diagnosis was $16.3{\pm}18.7$ months. Fifteen (42.9%) patients presented with classic malabsorption symptoms, whereas 7 (20.0%) patients presented with short stature. Positive tissue transglutaminase antibodies (tTg)-immunoglobulin A (IgA) was seen in 34 (97.1%) patients. The one patient with negative tTg-IgA had IgA deficiency. Although tTG-IgA values were not available for objective documentation of compliance, clinical data (resolution of presenting abnormalities and growth improvement) assured acceptable compliance in 22 (62.9%) patients. Conclusion: CD in children may present with diverse picture. Although of the small number, the non-classical presentations are not uncommon in our rural community. Gluten-free diet is the main strategy for treatment and associated with usually correction of laboratory abnormalities and improvement of growth.

Occupational Burden of Cancer in Korea

  • Kim, Eun-A;Lee, Hye-Eun;Kang, Seong-Kyu
    • Safety and Health at Work
    • /
    • 제1권1호
    • /
    • pp.61-68
    • /
    • 2010
  • Objectives: The extent of the occupational cancer burden has rarely been estimated in Korea. The aim of this study is to provide an estimation of the population attributable fraction (PAF) of occupational cancer in Korea. Methods: Nine kinds of Group 1 carcinogens addressed by the International Agency for Research on Cancer (IARC) and 7 kinds of cancer were selected for the target carcinogens and diseases, respectively. The prevalence of carcinogen-exposed workers was estimated and correction factors were applied so that the value would be representative of the total population. Data on relative risk (RR) were taken from IARC reports and were compared with the RRs from the studies on Korean workers. The PAF was estimated according to Levin's formula. Results: The proportion of the general Korean population exposed to carcinogens was 9.7%. The PAF of total cancer was 1.1% for incident cancer cases and 1.7% for cancer deaths. The PAFs of lung cancer and leukemia were 7.0% and 4.5%, respectively. With the RRs reported from Korean studies, the PAF for lung cancer and leukemia were 3.7% and 3.4%, respectively. Conclusion: The PAF in this study (1.1%) was lower than that reported in previous studies (2-4%) from developed countries. Considering that only 9 of the 29 kinds of Group 1 carcinogens were included in this study, the PAF might be underestimated. However, because the process of industrialization in Korea differs from that which occurred in other developed countries, 1.1% of the PAF might be appropriate for Korea.

3D 프린팅을 이용한 한국인 골밀도 맞춤 팬텀 개발 (Developing Customized Phantom for Korean Bone Density Using 3D Printing)

  • 이준호;최관용;최재호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권3호
    • /
    • pp.223-229
    • /
    • 2019
  • In order to reduce the radiation exposure dose of the patient and to obtain accurate diagnosis results, the quality control of the diagnostic radiation generator must be conducted periodically In particular, bone density test equipment could be influenced by many factors, and it is far more important because inaccurate measurement would eventually affect the result value. However, the cross-correction phantom of DXA equipment is poorly penetrated due to lack of awareness of the industry and the high cost. Therefore, this study developed a BMD phantom using a 3D printer and Korean BMD phantom with low cost by cross analyzing Korean BMD value from The Korean National Health and Nutrition Examination Survey and evaluated it. The L1, L2, and L3 BMD values of phantoms produced with the 3D printer were measured to be $0.887{\pm}0.006g/cm^2$, $0.927{\pm}0.006g/cm^2$, and $0.960{\pm}0.005g/cm^2$, at 215 mm height and $0.882{\pm}0.011g/cm^2$, $0.914{\pm}0.005g/cm^2$, $0.933{\pm}0.008g/cm^2$ at 155 mm height displaying statistically significant relevance. The result suggests that a proper quality control and cross calibration of DXA device be possible and expected to be an essential data for various medical phantom manufacture development using 3D printer.

의료기기 재처리 세척 직원의 개인보호구 착용 이행의 영향요인 (Factors Influencing Compliance on the Use of Personal Protective Equipment during Cleaning of Medical Device Reprocessing Staffs)

  • 박현희;홍정화;정계선;이광옥
    • 근관절건강학회지
    • /
    • 제31권1호
    • /
    • pp.42-52
    • /
    • 2024
  • Purpose: This study aimed to identify the factors affecting compliance with personal protective equipment (PPE) use among medical device reprocessing staff. Methods: This descriptive cross-sectional study included 163 cleaning staff members from ten general hospitals in Seoul and Gyeonggi. Data were collected using self-report questionnaires administered between July and September 2023. Analysis included t-tests, ANOVA, Pearson's correlation coefficient, Bonferroni correction, and multiple regression, conducted using SAS ver.9.4. Results: Statistically significant differences in compliance with PPE were found based on department and exposure to contamination within six months (t=-2.82, p=.007). Attitudes toward PPE (r=.22, p=.006) and awareness of the safety climate (r=.22, p=.006) showed a statistically significant positive correlation with PPE compliance. Factors influencing use of personal protective equipment by cleaning staff during medical device reprocessing were department, compliance with PPE, and awareness of the safety climate. The explanatory power of these factors was 58.0%. Conclusion: Improving PPE compliance and creating a safe cleaning environment entails fostering a supportive safety climate. Additionally, regular training that takes into consideration the characteristics of the cleaning staff, alongside continuous monitoring, is required.

PET-MRI에 대한 최적의 정보 제공에 대한 연구: 문헌 보고 중심으로 (A Study on the Optimal Information Provision for PET-MRI: Focused on Literature Article)

  • 손동섭;구은회
    • 방사선산업학회지
    • /
    • 제17권4호
    • /
    • pp.391-396
    • /
    • 2023
  • Currently, state-of-the-art devices such as SPECT, PET/CT, and PET/MRI are rapidly spreading nationwide, and the penetration rate of nuclear medical devices is also ranked fifth in the world. However, PET/MRI's system is slower and less common because it is more complex than PET/CT. The purpose of this study is to provide optimal information on PET/MRI according to the patient's disease. The subjects obtained information on head and neck cancer, pediatric patients, breast cancer patients, heart disease patients, lung cancer patients, and rectal cancer patients. We tried to accumulate protocols by obtaining a lot of information about each disease. In diagnosing head and neck cancer, it is believed that it is highly likely to be used in evaluating preoperative stage determination, recurrence and remote metastasis after treatment, and unclear primary cervical lymph node metastasis. Diagnosis and continuous follow-up of pediatric patients can increase patient benefits by minimizing radiation exposure. Breast cancer provides a comprehensive evaluation of the clinical need to determine the extent of disease in breast and local lymph nodes and the systematic stages of early diagnosis or recurrence. In diagnosing heart disease patients, MR-based PET motion correction helps to realize the full potential of PET images. For lung cancer patients, the clinical value and usefulness of the resolution and detection ability of integrated PET/MRI for soft tissues such as lung cancer will be sufficient. In diagnosing rectal cancer patients, the detection of missing residual diseases can change the clinical response evaluation for rectal cancer patients treated with TNT, and both the initial stage and treatment response evaluation are possible. Therefore, this literature study provided basic clinical data for PET/MRI tests.

지역사회 주민의 당화혈색소와 중금속 생체표지자와의 관련성 (The Association between HbA1c and the Biological Exposure Index for Heavy Metals in Community)

  • 민영선;이관
    • 농촌의학ㆍ지역보건
    • /
    • 제47권3호
    • /
    • pp.181-188
    • /
    • 2022
  • 당뇨병 발생에는 생활습관이나 생활환경과 관련된 다양한 원인들이 있는데 최근 연구에서 중금속에 많이 노출된 사람에서 당뇨병 발생 및 당뇨병의 악화가 늘어났다는 역학적 연구가 많이 발표되고 있다. 이에 국내 대규모 철강공업단지를 가진 일개 도시 지역 주민을 대상으로 당화혈색소와 체내 중금속의 상관성을 파악하고자 하였다. 2008~2009년 연구대상 총 414명에 대한 설문조사와 생체시료를 채취하였다. 설문은 성별, 연령, 인구학적 특성, 흡연, 음주, 직업, 당뇨진단 유무 등의 항목으로 구성하였다. 혈액을 채취하여 HbA1c, 혈중 납 농도를 측정하였고, 소변을 채취하여 요중 카드뮴, 무기비소, 수은 농도를 측정하였다. HbA1c는 6.5%기준으로 미만군과 이상군으로 분류하였다. 각 중금속별 10분위수부터 90분위수 농도에 해당하는 기준으로 미만군과 이상군 등 두 군을 분류하였다. 당뇨관련검사 결과 HbA1c 6.5% 기준으로 이상군은 남자 14(9.9%)명, 여자 17(6.2%)명이었다. 혈중 납의 기하평균 농도는 2.48 (1.80) ㎍/dl, 요중 카드뮴의 기하평균농도는 1.20 (2.26) ㎍/g creatinine, 요중 무기비소의 기하평균농도는 12.08 (1.80) ㎍/g creatinine, 요중 수은의 기하평균농도는 1.63 (2.23) ㎍/g creatinine 이었다. 연령, 지역, 성별, 흡연으로 보정하였을때 요중 카드뮴 농도 30분위수 이상군이 미만군에 비하여 교차비 5.26(95% 신뢰구간 : 1.44~19.17)으로 유의하게 높았다. 납, 무기비소, 수은은 HbA1c(6.5% 기준) 변수와의 교차분석에서 유의한 분포 차이는 없었다. 여러 요인을 보정하고도 요중 카드뮴과 HbA1c의 유의한 양의 상관관계를 파악하였고, 특히 유의한 상관관계를 보인 요중 카드뮴 농도의 특정 컷오프 값을 찾아내어 이를 통해 우리나라에 적합한 생물학적 노출값 설정의 참고자료로 활용될 수 있다는 점에서 의의가 있다고 생각한다.

On Board Imager (OBI)를 이용한 Setup Error 분석에 대한 연구 (Analyses of the Setup Errors using on Board Imager (OBI))

  • 김종덕;이행오;유재만;지동화;송주영
    • 대한방사선치료학회지
    • /
    • 제19권1호
    • /
    • pp.1-5
    • /
    • 2007
  • 목적: 방사선치료 시 OBI (on board imager) 시스템으로 환자 셋업 오차(set-up error)를 확인, 보정한 결과를 분석하여, 셋업 오차(set-up error)의 경향 및 원인을 살펴보고, 기존 필름과 EPID (electronic portal imaging device)를 사용한 방법에 비해 OBI의 정확성과 유용성에 대하여 알아보고자 한다. 대상 및 방법: 2006년 3월부터 2006년 5월까지 본원에 내원한 3차원 치료계획 환자 130명을 대상으로 주 1회 이상 OBI를 이용하여 치료전 셋업 영상의 분석을 시행하였다. 직각으로 획득한 2개의 영상을 모의 치료실에서 획득한 기준영상(reference image)과 합성(Fusion) 후 분석을 하였다. 분석 후 Vertical, Lateral, Longitudinal 방향으로 변위(Shift)거리를 측정하여 오차를 분석했다. 또한, 주요 부위별, 방향별로 구분하여 셋업 오차(set-up error) 요인들을 비교, 평가하였다. 결과: OBI를 적용하여 분석한 환자 41.5%에서 변위가 없이 Setup이 정확하였고, 52.3%에서 $1{\sim}5mm$정도의 오차가 존재하였다. 5 mm오차 이상인 환자도 6.1%가 확인되었다. 5 mm이상의 오차를 보인 환자들은 치료실내에서 확인한 결과 환자의 움직임이나 모의치료 자세와의 차이에서 오는 결과임을 알 수 있었다. 또한, 3 mm이상의 오차 경향이 3번 이상 지속될 경우에는 모의 치료실로 이동하여 보정후 치료를 시행하였다. 결론: 치료 전 2인의 근무자가 셋업을 정확히 하고 3면의 레이저와 조사야를 확인하였지만, 직각의 KV 영상으로 분석한 결과 셋업 오차가 발생할 수 있음을 확인하였다. 기존의 EPID에 의한 MV 영상은 낮은 영상의 특성과 환자의 피폭선량 증가라는 단점이 존재하지만, 본 연구에서 분석한 OBI는 모의 치료와 같은 높은 화질의 영상으로 셋업 오차의 정확한 계산과 객관적인 셋업 보정이 가능하여 영상유도 방사선치료의 정확도와 유용성을 입증할 수 있었다.

  • PDF

F-18 FDG 자동분주기의 분주 최적화에 관한 연구 (Study on Optimized Dispensing of F-18 FDG Auto Dispenser)

  • 지봉근;이상훈;김종언;김원태;지태정
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권3호
    • /
    • pp.377-384
    • /
    • 2016
  • 본 연구는 PET/CT 종사자의 피폭선량 감소 및 방사성의약품의 정확한 방사능량 투여를 목적으로 사용 중인 자동분주기의 분주 최적화에 관한 연구이다. 연구방법은 주사기 종류 및 분주 속도, Vial 압력에 따른 평가 결과를 통해 분주 횟수에 따른 오차 값을 알아보고 보정 값을 적용하여 최적화된 분주방법을 찾고자 하였다. 연구결과 5 ml 주사기에서는 평균 9.38 mCi가 분주되었고, 3 ml에서는 9.55 mCi가 분주되어 3 ml 주사기에서 10 mCi에 근접한 재현성을 보였다. 분주 속도에 따른 평가에서는 속도를 5, 10, 15, 20 mm/min 으로 증가시켜 10회씩 측정한 결과, 5 mm/min의 속도에서 10 mCi 정량에 가까운 방사성의약품이 분주되었다. Needle필터 사용 전/후 Vial 압력에 따른 평가 결과에서는 3 ml 주사기의 경우 사용 전 9.53 mCi, 사용 후 9.84 mCi로 측정되어 Needle필터를 사용한 후 분주하는 것이 최적화된 값으로 확인되었다. 또한 분주 횟수 증가에 따른 보정 값 적용 전/후 방사능 평가에서는 보정 전 9.53 mCi, 보정 후 10.07 mCi로 측정되어 보정 값을 적용한 실험에서 정량 값에 가까운 것으로 확인되었다. 따라서, 방사성의약품 분주 시 최적화된 분주방법은 주사기는 3 ml를 사용하고, 분주 속도는 5 mm/min로 설정하며 분주 시 Needle필터를 사용하고, 장비의 분주 횟수(x)에 따른 보정 값은 [$y=0.097{\times}x$]로 설정하는 것이 좋은 것으로 확인되었다.

경구흡수율을 반영한 농약의 AOEL 설정 및 농작업자 위해성 평가 (Application of Oral Absorption in Establishment of AOEL for Pesticides and Occupational Risk Assessment for farm worker)

  • 유아선;홍순성;이제봉;이승돈;임양빈
    • 농약과학회지
    • /
    • 제18권4호
    • /
    • pp.342-349
    • /
    • 2014
  • 미국, EU, 한국의 농작업자위해성평가를 위한 AOEL 설정, 국가별 경구흡수율 적용, 노출량 산출방법을 조사하였다. 농약성분 141종에 대한 경구흡수율을 조사하였으며 경구흡수율을 적용한 농작업자노출허용량(AOEL)과 국내 설정 AOEL을 이용하여 농작업자위해성평가를 실시하였다. 미국과 EU에서는 external dose를 internal dose로 변환하기 위하여 경구흡수율 또는 피부흡수율을 적용하였으나 한국에서는 AOEL 설정 시 경구흡수율을 적용하지 않은 external dose를 사용하였다. 141종의 농약성분 중 50종이 경구흡수율 80% 미만이었으며 경구흡수율을 적용하는 경우 약 36%의 농약성분이 이전 AOEL보다 낮아질 것으로 사료되었다. 50종의 농약성분 중 한국에 등록된 농약 28품목에 대해 EU AOEL을 이용하여 농작업자위해성평가를 실시한 결과, chlorothalonil WG 등 12품목이 독성노출비가 1 이하로 계산되어 위해성이 높은 것으로 나타났다. 또한 50종 중 한국 AOEL이 설정되어 있으며 한국에 등록된 농약 24품목에 대해 한국 AOEL을 이용하여 농작업자위해성평가를 실시한 결과, chlorothalonil WG 등 6품목은 독성노출비가 1 이하로 위해성이 높게 나타났다. 한국 AOEL이 없는 4품목에 대해 EU AOEL을 경구흡수율 100%로 환산한 수치를 이용하여 위해성평가를 실시한 결과, daminozide WP 등 4품목 모두 독성노출비 1 초과로 위해성이 낮게 나타났다. 경구흡수율 적용 및 미적용 EU AOEL과 한국 AOEL을 사용한 농작업자위해성평가를 비교한 결과 oxadiagyl SC 등 6품목을 제외한 22품목에서 동일한 위해성평가 결과가 나타났다. 본 연구 결과, 농작업자 위해성 평가를 실시할 때 경구흡수율을 적용한 AOEL을 이용할 수 있을 것으로 사료되었다. 경구흡수율을 적용한 AOEL 설정 및 이용한 농작업자위해성평가를 수행하였을 때 보다 실제에 가까운 평가방법으로 판단되므로 등록농약의 평가에 적용될 수 있도록 개선이 필요할 것으로 사료된다.

CMOS 이미지 센서의 영상 개선을 위한 실시간 전처리 프로세서의 설계 (Design of Real-Time PreProcessor for Image Enhancement of CMOS Image Sensor)

  • 정윤호;이준환;김재석;임원배;허봉수;강문기
    • 대한전자공학회논문지SD
    • /
    • 제38권8호
    • /
    • pp.62-71
    • /
    • 2001
  • 본 논문은 CMOS 이미지 센서에서 획득한 영상의 품질을 개선하기 위한 실시간 전처리 프로세서의 설계를 제시한다. CMOS 이미지 센서는 기존 IC와의 통합, 저전력소모, 저가격화등의 다양한 이점을 갖지만, 기존의 CCD 소자로부터 획득한 영상에 비해 열등한 품질의 영상을 제공하는 단점이 있다. CMOS 이미지 센서의 이러한 물리적 한계를 극복하기 위해 본 논문에서 제안하는 전처리 프로세서에는 색상 보간, 색상 보정, 감마 보정, 자동 노출 조정 등의 기본적인 전처리 알고리즘 외에 공간 가변적 대비 향상 알고리즘이 포함되었다. 여기에서 제안하는 전처리 프로세서는 이러한 알고리즘을 효율적으로 구현하기 위한 하드웨어 구조를 가지며, VHDL 언어를 이용하여 설계 및 검증되었다. 설계된 전처리 프로세서는 합성 결과 약 19K의 논리 게이트를 포함하였으며, 이는 저가격의 PC 카메라 구현에 적합하다. 제안된 전처리 프로세서의 실시간 동작 여부를 검증하기 위해 설계된 전처리 프로세서는 Altera사의 Flex EPF10KGC503-3 FPGA 칩으로 구현되었으며, 성공적으로 동작함을 확인하였다.

  • PDF