• 제목/요약/키워드: exposure control system

검색결과 490건 처리시간 0.041초

중소기업 도금공정에서의 6가 크롬 폭로에 관한 연구 (A Study on Worker Exposure to Hexavalent Chromium in Plating 0peration)

  • 정희경;백남원
    • 한국산업보건학회지
    • /
    • 제3권2호
    • /
    • pp.152-165
    • /
    • 1993
  • This study was performed at eleven small-sized plating factories located in Seoul, Incheon, Ansan, and Taejeon from July 21 to October 6, 1992. The major objectives of this study were to evaluate worker exposure to hexavalent chromium and local exhaust ventilation (L.E.V.) systems at the chromium plating operations. The most suitable L.E.V. systems for chromium plating tanks were designed as examples for recommendation to the industry. The results are summarized as follows. The range of chromium plating operations investigated included decorative, hard, and black chromium plating on several kinds of parts. Most of plating tanks were not equipped with proper control methods against emission of hexavalent chromium mists and workers were not wearing appropriate personal protectives. The ariborne hexavalent chromium concentrations showed an approximate lognormal distribution. The geometric means of both personal and area samples were within the Korean and ACGIH standards, $50{\mu}g/m^3$. However, in comparison with the NIOSH criterion, $1{\mu}g/m^3$, the geometric means of personal samples at two factories and the geometric means of area samples at two factories exceeded it. The geometric means of personal and area samples of high exposure groups (above the NIOSH criterion) were 7 and 27 times higher than those of low exposure groups (below the NIOSH criterion), respectively. The L.E.V. systems of high exposure groups were improperly designed, and the factory with the highest exposure level had no L.E.V. systems at all on chemical etching process. Whereas at factories of low exposure groups, mist control methods such as mist suppressants, tank cover, and/or auxillary L.E.V. systems were added to L.E.V systems. The evaluation of L.E.V. systems showed that there was no chromium plating operation satisfying the ACGIH criteria for capture velocity, slot velocity, and exhaust rate simultaneously. To increase performance of L.E.V. systems, it must be designed to minimize the impact of boundary layer separation. Push-pull ventilation hood and downward plenum ventilation hood were suggested for the Korean industry.

  • PDF

Mitochondrial oxidative damage by co-exposure to bisphenol A and acetaminophen in rat testes and its amelioration by melatonin

  • Hina Rashid;Mohammad Suhail Akhter;Saeed Alshahrani;Marwa Qadri;Yousra Nomier;Maryam Sageer;Andleeb Khan;Mohammad F. Alam;Tarique Anwer;Razan Ayoub;Rana J. H. Bahkali
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제50권1호
    • /
    • pp.26-33
    • /
    • 2023
  • Objective: Human exposure to multiple xenobiotics, over various developmental windows, results in adverse health effects arising from these concomitant exposures. Humans are widely exposed to bisphenol A, and acetaminophen is the most commonly used over-the-counter drug worldwide. Bisphenol A is a well-recognized male reproductive toxicant, and increasing evidence suggests that acetaminophen is also detrimental to the male reproductive system. The recent recognition of male reproductive system dysfunction in conditions of suboptimal reproductive outcomes makes it crucial to investigate the contributions of toxicant exposures to infertility and sub-fertility. We aimed to identify toxicity in the male reproductive system at the mitochondrial level in response to co-exposure to bisphenol A and acetaminophen, and we investigated whether melatonin ameliorated this toxicity. Methods: Male Wistar rats were divided into six groups (n=10 each): a control group and groups that received melatonin, bisphenol A, acetaminophen, bisphenol A and acetaminophen, and bisphenol A and acetaminophen with melatonin treatment. Results: Significantly higher lipid peroxidation was observed in the testicular mitochondria and sperm in the treatment groups than in the control group. Levels of glutathione and the activities of catalase, glutathione peroxidase, glutathione reductase, and manganese superoxide dismutase decreased significantly in response to the toxicant treatments. Likewise, the toxicant treatments significantly decreased the sperm count and motility, while significantly increasing sperm mortality. Melatonin mitigated the adverse effects of bisphenol A and acetaminophen. Conclusion: Co-exposure to bisphenol A and acetaminophen elevated oxidative stress in the testicular mitochondria, and this effect was alleviated by melatonin.

암치료용 레이저 시스템 개발 (The development of laser system for cancer)

  • 이동진;김주명;김선학;임현수
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2001년도 하계학술발표회
    • /
    • pp.154-155
    • /
    • 2001
  • A laser system for therapy of cancer is proposed in this paper. In order to accuracy and statistical output control we used the constant current control method and designed the power source to protect the resonator from the over -current, rush-current and electrical fault. The most important things are the radiation type for cancer therapy in laser system, we developed the radiation type of cw, pulse, and burst pulse. The experimental result show that laser beam power increase linearly from 100mW to 300mW for input current increasing and the exposure time.

  • PDF

동물병원의 방사선발생장치 정도관리에 대한 연구 (Quality Control of Diagnostic X-ray Units for Animal Hospital)

  • 김상우;이지훈;박예슬;임재동;성열훈
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2010년도 춘계학술대회
    • /
    • pp.231-237
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using quality assurance (QA) and quality control (QC) of diagnostic X-ray units. The surveys for QA/QC, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The QA/QC included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. As a result, 44.44% of reproducibility of dose exposure was proper, 81. 25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test.

  • PDF

사용후 핵연료 원격 취급 장치의 퍼지 제어 (Remote control of spent nuclear fuel handling equipment with fuzzy logic)

  • 김기준;김호동;윤완기;이재설
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.911-916
    • /
    • 1991
  • Spent nuclear fuel is highly radioactive and requires remote operation due to radiation exposure. Motors which have been used in the highly radioactive environments are a DC type because of their easy implementation on control system. However there are some problems such as mechanical maintenance of brush and commutator, high cost, and heavy material control. AC servo motors are applied and tested on fuzzy and conventional control algorithms. Fuzzy logic controls of AC servo give adequate control accuracy and power for spent fuel handling in radioactive environments.

  • PDF

광자 준결정 제작을 위한 다중 노광 나노구 리소그라피 연구 (A study of multiple-exposure nanosphere lithography for photonic quasi-crystals fabrication)

  • 여종빈;이현용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.62-62
    • /
    • 2010
  • Photonic quasi-crystals(PQCs) have been fabricated by a multiple-exposure nanosphere lithography (MENSL) method using the self-assembled nanospheres as lens-mask patterns. The multiple-exposing source is collimated laser beam and rotation, tilting system. The arrays of the PQCs exhibited variable lattice structures and shape the control of ratating angle ($\theta$), tilting angle ($\gamma$) and the exposure conditions. The used nanosphere size is upto the $1\;{\mu}m$. Images of prepared 2D PQCs were observed by SEM. We believe that the MENSL method is a suitable useful tool to realize the PQCs arrays of large area.

  • PDF

입자상 물질 폭로농도의 통계적 평가방법에 관한 고찰 -용접·연삭 작업장의 근로자를 대상으로- (A Statistical Assessment of Particulate Exposure Concentration for the Welders and Grinding workers)

  • 윤영노;이관형
    • 한국산업보건학회지
    • /
    • 제1권2호
    • /
    • pp.154-163
    • /
    • 1991
  • Particulate matter exposure leva1 of welders and grinding workers was evaluated in Banwol and Changwon industry complexes. Full period single sample and full period consecutive samples were collected with personal air samplers attached to workers. Compliance difference with 8-hour time weighted average (TWA) was compared by Korean strategy and the classification system recommended by OHSA for employee exposure to particulates. And difference of compliance was compared according to precision of measurement and analysis (total precision). Compliance rate was depended on the total precision, therefore, quality control of measurement and analysis was important.

  • PDF

Effects of Beryllium on Human Serum Immunoglobulin and Lymphocyte Subpopulation

  • Kim, Ki-Woong;Kim, DaeSeong;Won, Yong Lim;Kang, Seong-Kyu
    • Toxicological Research
    • /
    • 제29권2호
    • /
    • pp.115-120
    • /
    • 2013
  • To investigate the effects of short-term exposure of beryllium on the human immune system, the proportion of T-lymphocytes such as CD3+, CD4+, CD8+, CD95, and NK cells, and the proportion of B cells and $TNF{\alpha}$ level in peripheral blood and immunoglobulins in the serum of 43 exposed workers and 34 healthy control subjects were studied. External exposure to beryllium was measured by atomic absorption spectrometer as recommended by the NIOSH analytical method 7300. T lymphocyte subpopulation analysis was carried out with flow cytometer. The working duration of exposed workers was less than 3 months and the mean ambient beryllium level was $3.4{\mu}g/m^3$, $112.3{\mu}g/m^3$, and $2.3{\mu}g/m^3$ in molding (furnace), deforming (grinding), and sorting processes, respectively (cited from Kim et al., 2008). However, ambient beryllium level after process change was non-detectable (< $0.1{\mu}g/m^3$). The number of T lymphocytes and the amount of immunoglobulins in the beryllium-exposed workers and control subjects were not significantly different, except for the total number of lymphocytes and CD95 (APO1/FAS). The total number of lymphocytes was higher in the beryllium-exposed individuals than in the healthy control subjects. Multiple logistic regression analysis showed lymphocytes to be affected by beryllium exposure (odd ratio = 7.293; p<0.001). These results show that short-term exposure to beryllium does not induce immune dysfunction but is probably associated with lymphocytes proliferation.

아연의 체내축적이 대복의 생존, 운동성, 성장 및 기관계 구조에 미치는 영향 (Effect of Zinc Bioaccumulation on Survival Rate, Activity, Growth and Organ Structure of the Equilateral Venus, Gomphina veneriformis (Bivalvia: Veneridae))

  • 주선미;이재우;진영국;유준;이정식
    • Environmental Analysis Health and Toxicology
    • /
    • 제21권2호
    • /
    • pp.115-126
    • /
    • 2006
  • This study was conducted to find out survival rate, activity, growth and change of the organ structure of bivalves exposed to heavy metal. The results of the study confirmed that zinc (Zn) induces reduction of survival rate and activity, abnormality of organ structure of the equilateral venus, Gomphina veneriformis. Experimental groups were composed of one control condition and three Zn exposure conditions ($0.64mg\;Zn{\iota}^{1},\;1.07mg\;Zn{\iota}^{-1},\;1.79mg\;Zn{\iota}^{-1}$). As the concentration of zinc increased the accumulation of lipofucin increased in the digestive gland. Survival rate was the lowest in the lowest Zn exposure group at $0.64mg;Zn{\iota}^{-1}$. Growth was not significantly different between the control and exposure group. Activity. with the exception of the lowest Zn exposure group at $0.64mg\;Zn{\iota}^{-1}$, was similar between the control and exposure group. Histological analysis of organ system illustrated expansion of hemolymph sinus, loss of striated border of inner epidermis, increase in the number of mucous cell in the mantle. Also, histological degenerations as epithelial necrosis and hyperplasia of mucous cells are recognized in the gill and foot.

Networked Intelligent Motor-Control Systems Using LonWorks Fieldbus

  • 홍원표
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.365-370
    • /
    • 2004
  • The integration of intelligent devices, devices-level networks, and software into motor control systems can deliver improved diagnostics, fast warnings for increased system reliability, design flexibility, and simplified wiring. Remote access to motor-control information also affords an opportunity for reduced exposure to hazardous voltage and improved personnel safety during startup and trouble-shooting. This paper presents LonWorks fieldbus networked intelligent induction control system architecture. Experimental bed system with two inverter motor driving system for controlling 1.5kW induction motor is configured for LonWorks networked intelligent motor control. In recent years, MCCs have evolved to include component technologies, such as variable-speed drives, solid-state starters, and electronic overload relays. Integration was accomplished through hardwiring to a programmable logic controller (PLC) or distributed control system (DCS). Devicelevel communication networks brought new possibilities for advanced monitoring, control and diagnostics. This LonWorks network offered the opportunity for greatly simplified wiring, eliminating the bundles of control interwiring and corresponding complex interwiring diagrams. An intelligent MCC connected in device level control network proves users with significant new information for preventing or minimizing downtime. This information includes warnings of abnormal operation, identification of trip causes, automated logging of events, and electronic documentation. In order to show the application of the multi-motors control system, the prototype control system is implemented. This paper is the first step to drive multi-motors with serial communication which can satisfy the real time operation using LonWorks network.

  • PDF