• Title/Summary/Keyword: exposure control system

Search Result 490, Processing Time 0.031 seconds

Changes of Thyroid Hormone Levels in Plasma of Rats during Cold Exposure (저온환경 적응에 있어서의 갑상선 Hormone의 변동)

  • Lee, H.W.;Kim, W.J.;Hong, S.S.;Kim, H.S.;Hong, S.U.
    • The Korean Journal of Pharmacology
    • /
    • v.17 no.2
    • /
    • pp.37-45
    • /
    • 1981
  • The importance of thyroid hormones for the survival of rats in the cold is along-established fact. Hypothyroid animals are unable to survive in a cold environment. It was also reported that acute exposure of rats, guinea pigs and rabbits to cold produced an increased secretion of TSH and thereby thyroid hormone secretion within 10 to 30 min, but this increase of thyroid activity disappeared quite rapidly during warming. However, in human study no significant difference was found in the concentration of $T_4$, TSH and cortisol between summer and winter. But plasma $T_3$ concentration was increased significantly in winter in 56 adult men. On the other hand, it has been also known that catecholamines are important in the maintenance of body temperature of rat exposured to cold. Abundant evidences suggest that the sympathetic nervous system is involved in the activation of nonshivering thermogenesis and that thyroid hormone metabolism and secretion are influenced by catecholamines and consequently by the activity of the sympatheticadrenal system. Many of the metabolic effects of catecholamines are associated with an increase in the level of cAMP mediated through activation of adenylate cyclase which converts ATP to cAMP. Other studies have shown that thyroid hormones affect the amount of adenylate cyclase present in the adipose tissue. On the other hand. it was also reported that a particulate cAMP phosphodiesterase activity in fat cells was modulated by the action of thyroid hormones. The objective of the present study was to determine the interaction between thyroid activity and cyclic nucleotides during acute exposure to cold. Albino rats weighing around 200 g were used as the experimental animal. The room temperature group was kept at $25^{\circ}C$ and the cold-exposured group was kept at $4^{\circ}C$ for 1 week or 2 weeks. Each group was subdivided into three subgroups; control, KI, and MTU group. At the end of experiment the animals were etherized and blood was taken from abdominal aorta for $T_4,\;T_3$ and cyclic nucleotides. The determinations of $T_3,\;T_4$ and cyclic nucleotides were carried out with a radioimmunoassay(RIA) method. The results were summerized as followings. 1) A significant increase of thyroid weight was observed in rats exposured to cold for 2 weeks. Furthermore, in rats administered MTU while to exposure to cold the thyroid weight was also increased significantly. 2) After 2 weeks $T_3$ concentration in the plasma of cold-exposured rats was significantly increased in KI group and MTU group as well as in control group. On the contrary, after 2 weeks of cold exposure $T_4$ level was decreased in control group. 3) In the case of cyclic nucleotides, plasma cAMP was increased in the control group after 1 or 2 weeks of cold exposure. However, cAMP level in plasma was rather significantly decreased in KI group and MTU group as well as in control group.

  • PDF

Robust sliding mode control for a USV water-jet system

  • Kim, HyunWoo;Lee, Jangmyung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.2
    • /
    • pp.851-857
    • /
    • 2019
  • A new robust sliding mode control with disturbance and state observers has been proposed to control the nozzle angle of a water-jet system for a Unmanned Surface Vehicle (USV). As the water-jet system of a ship is subjected to direct disturbances owing to the exposure to the marine environment in water, it requires a robust control. A state observer and a disturbance observer are added to the water jet nozzle control system to achieve a robust control against disturbances. To verify the performance of the proposed algorithm, a test bed is constructed by a propulsion system used in the popular USV. This proposed algorithm has been evaluated by comparing to the existing algorithm through experiments. The results show that the performance of the proposed algorithm is better than that of the conventional PID or sliding mode controller when controlling the steering of the USV with disturbances.

Patient Exposure Dose Reduction in Coronary Angiography & Intervention (심혈관조영술 및 중재술 시 환자 선량 감소방안)

  • Lim, Do-Hyung;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.45 no.1
    • /
    • pp.69-76
    • /
    • 2022
  • This study, the method of reducing the exposure dose by changing the geometrical requirements among the preceding studies and the method of directly wearing a protector on the patient were used to expose the patient. A comparative experiment was conducted on the method of reducing the dose and the most effective method for reducing the exposure dose was investigated. Using the phantom, the dose of the lens, thyroid gland, and gonad gland in the 5 views most used in coronary angiography and intervention accumulated 5 times for 10 seconds at 60~70 kV, 200~250 mA as an automatic controller of the angiography system, and measured by Optically Stimulated Luminescent Dosimeter(OSLD). SID 100 cm and Cine 15 f/s as a control group the experiment was conducted by dividing the experimental group into 3 groups: a group lowered to Cine 7.5 f/s, a phantom protector, and a group lowered to 95 cm SID. As a result of the experiment, showing decrease in exposure dose compared to the control group. Lowering the cine frame may be the simplest and most effective method to reduce the exposure dose, but there is a limit that it cannot be applied if the operator judges that the diagnostic value is small or feels uncomfortable with the procedure. Conclusion as fallow reducing the exposure dose by directly wearing protector is the next best solution, and it is hoped that the conclusions obtained through this study will help reduce the exposure dose to unnecessary organ.

Worker's exposure assessment of cyclonite in explosive compounds and bomb manufacturing companies (폭약 및 폭탄 제조시 발생하는 시클로나이트의 작업자 노출수준 평가)

  • Jeong, Jee Yeon;Lee, Jee Hyeon;Kim, Eun Young;Lee, Seung Hoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.21 no.1
    • /
    • pp.55-61
    • /
    • 2011
  • Cyclonite is a white powder and is very explosive. It can cause seizures (a problem of the nervous system) in human and animals when large amounts are inhaled or eaten. Research papers for workers exposure assesment of the cyclonite are very a few in the world. A field study was conducted at explosive compounds and bomb manufacturing companies to evaluate workers exposure to cyclonite. The airborne average concentration of cyclonite in explosive compounds manufacturing company was $4.10{\mu}g/m^3$(range: ND - $59.92{\mu}g/m^3$), and that of cyclonite in bomb manufacturing company was $31.49{\mu}g/m^3$(range: ND - $291.41{\mu}g/m^3$). Package process and assembly process in both companies were considered the high potential of exposure to cyclonite. Even though all airborne concentrations of cyclonite were lower than occupational exposure standard (MOEL: $500{\mu}g/m^3$), exposure to cyclonite can also occur through dermal contact during manufacture, handling, and clean-up of cyclonite. So control measures for protecting skin absorption of cyclonite were needed for preventing adverse health effect by cyclonite exposure.

Mobi-Kids Study: Exposure Assessment of Electromagnetic Radiation from Mobile Phones I. Analysis on Exposure Types (Mobi-Kids Study: 휴대전화의 전자파 노출량 평가 I. 노출 유형 분석)

  • Lee, Ae-Kyoung;Wi, Hyunho;Yoon, Yonghyun;Kim, Dae-Keon;So, Jae-Sang;Lee, Byungje;Choi, Hyung-Do
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.10
    • /
    • pp.1017-1026
    • /
    • 2013
  • Four countries are participating in exposure assessment for Mobi-Kids Study. Each country evaluates RF and ELF exposure from mobile phones considering telecommunication system and environment in the corresponding area. The results will be used to determine accumulation exposure level of each subject in case and control groups to assess the potential carcinogenic effects of childhood and adolescent exposure to radio frequency(RF) and extremely low frequency( ELF) from mobile phones on the central nervous system. This paper analyzes exposure types of mobile phones which have been used in Korea for about 10 years, based on Mobi-Kids protocol. It includes investigation of mobile phone models released in the domestic market, design of numerical phone models to represent each exposure type, and measurement of ELF radiation from mobile phones.

The Research of Railway Noise through Auditory Experiments Focused on the Autonomic Nervous System and Cardiovascular System (청감실험을 통한 철도소음의 자율신경 및 심혈관계통 영향도 연구)

  • Lee, Jae Kwan;Yoon, Eun Sun;Jang, Chae Mi;Jae, Sae Young;Chang, Seo-Il
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.6_spc
    • /
    • pp.674-679
    • /
    • 2016
  • According to the conventional studies on the noise and cardiovascular effect, railway noise is better associated with hypertension and adverse cardiovascular events than road traffic noise. But the underlying mechanisms remain unclear. We investigated the hypothesis that exposure to acute railway noise would the unfavorable effect of cardiovascular and autonomic system in healthy young subjects. Using a randomized, sham-controlled cross-over design, ten subjects were assigned to receive either an exposure to high speed train noise (84 dB) for 30 minutes or a control condition (non noise), separated by two days. Blood pressure, heart rate, augmentation index and heart rate variability as indices of cardiovascular and autonomic system function were measured at baseline, during, and recovery from two trials. The results show that exposure to acute railway noise significantly increased diastolic blood pressure and augmentation index, which may cause of adverse cardiovascular effects.

Study on image quality and dosage comparison of F/S system and DR system (F/S시스템과 DR시스템의 화질과 피폭선량 비교에 관한 검토)

  • Kim, Sun-Chil;Jung, Jae-Eun
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.7-11
    • /
    • 2003
  • Currently, many hospitals are hastening to introduce digital radiography systems. This is a direct result of the intentions to improve medical services and to digitalize radiology information systems, and is also leading to the improvement of medical imaging technology. Throughout F/S system's long history, many people have researched the image quality and dosage concerning these systems, and as a result, huge improvements in the dosage of patients were possible. Similarly, I believe that DR systems need the same kind of effort. Of course, decreases in dosage that ignore image quality are unthinkable. The results of experiments conducted by five hospitals during a period of 3 months brought to us the conclusions listed below. 1. Based on the comparison and analysis of the exposure control of F/S systems and DR systems, DR systems generally showed higher exposure control for parts of the phantom that became thicker, and the exposure control improved rapidly as the thickness increased. 2. DR systems still proved to be somewhat deficient in resolution measurements compared to existing F/S systems. The image processing part of DR systems contributed much to these result. 3. Under conditions used clinically, the dosage measurements of DR systems were generally higher regardless of region. 4. According to the evaluation of image quality, DR systems showed a higher degree of satisfaction as the thickness of the region became thinner. As mentioned above and based on the mutual relationship experiments between the dosage and image quality of F/S systems and DR systems, research to increase the satisfaction of DR systems must be considered.

  • PDF

Measurement of Breast Skin Dose According to Shield Thickness During Whole Spine Scanography Using Digital Radiography System (Digital Radiography 시스템을 사용하여 전 척추검사 시 차폐체 두께에 따른 유방피부선량 측정)

  • Nam, Soon-Kwon;Choi, Joon-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.1
    • /
    • pp.25-30
    • /
    • 2019
  • Whole Spine Scanography (WSS) using the Digital Radiography (DR) system is an examination that requires whole body X-ray exposure, which involves more exposure to radiation for patients than other general radiographies. This can affect the occurrence of breast cancer. This research measured radiation dose when breasts were shield and not shield using the Auto Exposure Control (AEC) mode. The radiation dose without a shield was 1.540 mGy, and that using a collimator was measured 0.506 mGy. Moreover, 0.733 mGy was measured when 1 shield (0.3 mm) was used, and $0.523{\mu}Gy$ when 5 of them (1.5 mm) were used. The results showed that the radiation dose with 5 shields and the radiation dose with a collimator were similar. Moreover, 0.233 mGy was measured when 8 shields (2.4 mm) were used. The standard deviation were 0.081 when using collimator and 0.014 when 5 shields were used. Also, when 8 shields were used, it was found to be 0.002. Most patients who go under a scoliosis test are children or young people who are highly sensitive to radiation. In the research results, the case where the organs sensitive to radiation, women's breasts, were shielded showed more distinct differences compared to without shields. It is considered that using shields can provide more constant shield than using a collimator and lower the risk of breast cancer caused by exposure to radiation.

Blue light Exposure Control System Using Sensor Modules

  • Lim, Myung-Jae;Jung, Dong-Kun;Kim, Kyu-Dong;Kwon, Young-Man
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.315-319
    • /
    • 2021
  • Recent impact of 4th industrial revolution is increasing usage of IoT technology along with smartphones and tablet PC. However blue light emitted from electronic devices such as smartphones and tablet PC causes detrimental change to human bodies. As the controversy over the harmfulness of blue light became known through the media and various communities, related markets were formed, and various blocking films, software, and vision protection monitors were released. In this paper focuses on utilizing IoT technology to protect human organizations from blue light. It presents anti-blue light system which prevents excessive exposure to blue light through Arduino module such as ultrasound, piezo buzzer and blue light measurement module.

Set Up and Operation for Medical Radiation Exposure Quality Control System of Health Promotion Center (건강검진센터의 의료방사선 피폭 품질관리 시스템 구축 운영 경험 보고)

  • Kim, Jung-Su;Jung, Hae-Kyoung;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.13-17
    • /
    • 2016
  • In this study, standard model of medical radiation dosage quality control system will be suggested and the useful of this system in clinical field will be reviewed. Radiation dosage information of modalities are gathered from digital imaging and communications in medicine(DICOM) standard data(such as DICOM dose SR and DICOM header) and stored in database. One CT scan, two digital radiography modalities and two mammography modalities in one health promotion center in Seoul are used to derive clinical data for one month. After 1 months research with 703 CT scans, the study shows CT $357.9mGy{\cdot}cm$ in abdomen and pelvic CT, $572.4mGy{\cdot}cm$ in brain without CT, $55.9mGy{\cdot}cm$ in calcium score/heart CT, screening CT at $54mGy{\cdot}cm$ in chest screening CT(low dose screening CT scan), $284.99mGy{\cdot}cm$ in C-spine CT and $341.85mGy{\cdot}cm$ in L-spine CT as health promotion center reference level of each exam. And with 1955 digital radiography cases, it shows $274.0mGy{\cdot}cm2$ and for mammography 6.09 mGy is shown based on 536 cases. The use of medical radiation shall comply with the principles of justification and optimization. This quality management of medical radiation exposure must be performed in order to follow the principle. And the procedure to reduce the radiation exposure of patients and staff can be achieved through this. The results of this study can be applied as a useful tool to perform the quality control of medical radiation exposure.