• Title/Summary/Keyword: exposure control system

Search Result 490, Processing Time 0.026 seconds

Evaluation of Chemical Resistance Performance of Synthetic Rubber and Cement Based Injection Repair Materials Used in Underground Concrete Structures (지하 콘크리트 구조물에 적용되는 합성고무계 및 시멘트계 주입형 보수재료의 화학 저항성능평가)

  • Kim, Soo-Yeon;Lee, Yeon-Sil;Song, Je-Young;Kim, Byoungil;Oh, Sang-Keun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.5
    • /
    • pp.148-155
    • /
    • 2017
  • In this study, by using the international standards ISO TS 16774, Part 2 Test method for chemical resistance as a quality control method of injection type repair material used for leakage crack of underground concrete structure, the performance requirement against of chemical environment of underground concrete structures for repair materials was tested. For this testing 3 types for each of the 2 classes of repair materials(synthetic rubber, cement), with a total of 9 types repair materials, were selected and examined. As a result, the test results showed that the smallest performance deterioration by the change in the mass was with the synthetic rubber(RG) type as opposed to the cement type system, showing that the synthetic rubber type had the strongest relative resistance to chemical exposure. Furthermore, it is necessary to investigate the material with high resistance to chemical substances and to examine the material which can increase resistance to sodium hydroxide and sodium chloride in cement system. These results can be used as a basic index for the selection of repair materials with the strongest resistance to chemical environment found in concrete structures. In addition, it is expected that the test results derived in this study can be used as reference data that can be reflected in the quality improvement of the maintenance material to be developed later.

Assessment of VOCs Emission Characteristics from Building Materials such as Wall Paper, Paints, and Adhesives Using Small Chamber Method (소형챔버법을 이용한 건축자재 중 벽지, 페인트 및 접착제의 VOCs 방출특성 평가)

  • Lee Suk-Jo;Jang Seong-Ki;Cho Yong-Sung;Jung Kyung- Mi;Jeong Gi-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.2
    • /
    • pp.191-204
    • /
    • 2005
  • Building and furnishing materials and consumer product are important sources of volatile organic compounds(VOCs) and other aldehydes in the indoor environment. Some available evidence indicates that VOCs can cause adverse health effects to the building occupants and contribute to some of the symptoms of what we call, 'Sick House Syndrome' in Korea. The aims of this study were to evaluate the efficiency of emission system and to investigate comparison of the emission characteristics of different building materials such as wall-papers, paints, and adhesives. The emission of VOCs from building materials were determined in the small chambers defining the temperature, relative humidity, and ventilation rate in this study. VOCs were sampled for 20 minutes using Tenax-TA tubes and analysed by GC-MS with thermal desorption. The stability of conditions for temperature and relative humidity in this small chamber system showed that the fluctuation of temperature was between 25.4$\pm$0.3$^{\circ}C$ and that of relative humidity was 50.2$\pm$0.6$\%$ under the airflow rate of 167 mL/min. The emission tests from building materials resulted in TVOC emission rates of 0.011 $\~$ 3.108 mg/m$^{2}$h after 7 days. The general wall-papers emitted toluene abundantly and the natural wall-papers mainly emitted n-butanol and a minor amount of alkanes compound such as n -tetradecane. The remainder consisted of toluene, m,p -xylene, and styrene. The paints mainly emitted toluene and the adhesives mainly emitted chloroform as well as toluene. As a result, this study is expected to suggest meaningful data for future studies in exposure control through selecting healthy building materials and for the establishment of guidelines for various building materials in Korea.

Noise Exposure of Radiographer Caused by Magnetic Resonance Imaging(MRI) (자기공명영상(MRI) 검사 시 방사선사의 소음노출)

  • Gil, Jong-Won
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.11
    • /
    • pp.699-706
    • /
    • 2016
  • This study aimed to propose the necessity and system establishment of noise reduction facility via evaluating noise level exposed by the radiographer due to MRI scan. Noise measurements were carried out using at S general hospital in Daejeon using 1.5 Tesla MRI (7 exams) and 3.0 Tesla MRI (16 exams), while using SC-804 noise meter. The measurement distance was from the soundproof door of the MRI room to the radiographer which measured 100cm, and the measurement height, the height to the radiographer's ears when working, 100cm. The noise measured for each exam was an average of three measures per exam which observed the noise occurring in each sequence recorded every 20 seconds. As the results, the maximum of noise exposed by the radiographer is 73.3 dB(A), which is MRCP by the 3.0 Tesla device, and also the maximum of average noise is 66.9(3.1) dB(A), which is Myelogram by the 3.0 Tesla device. Average noise by each device is 61.9(4.1) dB(A) by the 3.0 Tesla device and 52.0(3.1) dB(A) by the 1.5 Tesla device, which comes to the result that the 3.0 Tesla MRI device is about 10 dB(A) degree higher(p <0.001). The noise level exposed by the radiographer does not affect auditory acuity, but the level is able to incur a non auditory effect. The reflect sound can be removed by installing curtains in the rear wall of MRI control room in order to reduce the noises, but, first of all, An institutional system is needed in order to prevent noise.

Eco-physiological Responses of Two Populus deltoides Clones to Ozone

  • Yun, Sung-Chul;Kim, Pan-Ki;Hur, Jae-Seoun;Lee, Jae-Cheon;Park, Eun-Woo
    • The Korean Journal of Ecology
    • /
    • v.24 no.2
    • /
    • pp.93-100
    • /
    • 2001
  • One-year-old cottonwood (Populus deltoides Bartr.) clones, which were classified as sensitive or tolerant, were exposed to 150 n1/1 ozone (O$_3$) over 8 days for 8 hours each day under glass chamber conditions with natural sunlight. The leaves of the sensitive clone had black stipple and bifacial necrosis after $O_3$ treatment. Photosynthesis and stomatal conductance were measured before, during, and after the $O_3$ treatment. The photosynthetic rates due to $O_3$ treatment were decreased 51 percent and 34 percent on the sensitive and tolerant clone, respectively. The stomatal conductance of the sensitive clone was more than 40 percent higher than that of the tolerant clone regardless of the $O_3$ treatment. As light intensity increased, the $O_3$ effect on photosynthesis was clear. Compared to the previous growth chamber studies, our natural light exposure system was able to maintain a stable photosynthetic responses of the control treatment throughout the fumigation period. In addition, changes in assimilation versus intercellular $CO_2$ concentration (A/C curves) showed that $O_3$ decreased the slope and asymptote of the curves for the sensitive clone. This indicates that $O_3$ decreases the biochemical capacity of photosynthesis on the sensitive clone. Chlorophyll contents and fluorescence of the two clones were analyzed to examine the $O_3$ effects on photosystem 11, but $O_3$ did not impact these variables on either clone. Although the tolerant clone did not show any foliar injury, we could not find any ecophysiological defensive responses to $O_3$ treated. Stomatal conductance of the tolerant clone was originally much lower than that of the sensitive one. Thus, the mechanisms of the tolerant clone in this system are to narrowly open stomata and efficiently maintain photosynthesis with a more durable biochemical apparatus of photosynthesis under $O_3$ stress. The sensitive clone has higher photosynthetic capacity and more efficient light reaction activity than the tolerant one under charcoal filtered condition, but is not as resilient under stress.

  • PDF

Bacteriological Research for the Contamination of Digital Portable Radiography (디지털 이동방사선검사에서의 세균 오염도)

  • Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.7-12
    • /
    • 2017
  • The study was performed to investigate the bacteriological contamination of portable digital radiography system and their detectors in a university hospital. CNS and VRE were detected in the samples collected from vinyl cover on detectors used for the infection control patients. On the other hand, no bacteria was detected in the samples collected from detectors with vinyl cover removed. In the series of imaging of patients from general wards, no bacteria was detected from the patient 1. However, CNS was detected from the patients 2 and 3, CNS and Enterococcus faecalis detected from the patient 4, CNS and Enterococcus casseliflavus detected from the patient 5, and CNS, Enterococcus casseliflavus, and Klebsiella pneumoniae all detected from the patient 6. CNS and Enterococcus faecium were detected in the controller handle of collimator. Also, CNS was detected from the handle of detector and exposure switch. In the treatment gloves of the radiological technologist after the imaging, CNS, Enterococcus gallinarum, and Klebsiella pneumoniae were detected. Therefore, it is recommended for DR portable to take images after sterilizing the detector after taking each image and to use disposable vinyl covers on detectors to remove after imaging. And treatment gloves must be changed after each imaging. Also, hospital infection via portables must be prevented by complete sterilization of the controller handles of collimator which are in frequent contact during imaging and infection education of employees.

The Electrochemical Chlorination for Marine Plankton Community Disinfection (해양 플랑크톤 군집의 전기분해 염소소독 효과)

  • Kang, Jung-Hoon;Shin, Kyoung-Soon;Hyun, Bong-Gil;Jang, Min-Chul;Kim, Eun-Chan;Chang, Man
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.10 no.3
    • /
    • pp.127-137
    • /
    • 2007
  • To confirm whether or not the Electrochemical Disinfection System (EDS) meet with the D-2 regulation established by IMO (International Maritime Organization), the biological treatment efficacy of the EDS was assessed using three groups of natural marine plankton (bacteria, $10-50\;{\mu}m$ and $>50\;{\mu}m$ sized organisms). Influent water was passed through the EDS under the flow velocity ($23.8\;m^3/hr$) and test design was consisted of control (no treatment) and experimental (10 ppm and 30 ppm) condition for total residual chlorine (TRC). And the biological condition of the influent water followed the standards established by the guidelines for the approval of ballast water management systems. The disinfection efficacy of the $10-50\;{\mu}m$ sized organisms (phytoplankton) was assessed by three kinds of measurements using photomicroscope, epifluorescence microscope and fluorometer (fumer Designs 10-AU). After being passed through the EDS, all motile phytoplankton lost their motility under photomicroscope, the colour of chlorophyll fluorescence fumed from red into green under epifluorescence, and the high chlorophyll fluorescence (Expt. 1: 6.95, Expt. 2: 7.11) detected by fluorometer decreased into value not detected. These results indicated phytoplankton community was totally killed after electrochemical disinfection treatment. Survivorship of the larger organisms than $50\;{\mu}m$ was determined based on the appendage's movement under a stereomicroscope. Natural assemblage collected from ambient seawater was killed shortly after being passed through the EDS, whereas some Artemia remained alive. However, no live Artemia was found after 24 hour further exposure to each TRC concentration (10 and 30 ppm) under darkness. After electrochemical treatment, the target bacteria such as aerobes, coliform and Escherichia coli were completely killed on the basis of CFU (colony forming unit) on Petrifilm plate ($3\;M^{TM}$) after 48 hr incubation. Moreover, no regrowth was found in the three groups of plankton during five days under additional exposure to the treated water. These results indicated that the disinfection efficiency of the EDS on the three groups of plankton satisfy D-2 regulation.

  • PDF

Microbe Hunting: A Curious Case of Cryptococcus

  • Bartlett, Karen H.;Kidd, Sarah;Duncan, Colleen;Chow, Yat;Bach, Paxton;Mak, Sunny;MacDougall, Laura;Fyfe, Murray
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.45-72
    • /
    • 2005
  • C. neoformans-associated cryptococcosis is primarily a disease of immunocompromised persons, has a world-wide distribution, and is often spread by pigeons in the urban environment. In contrast, C. gattii causes infection in normal hosts, has only been described in tropical and semi-tropical areas of the world, and has a unique niche in river gum Eucalyptus trees. Cryptococcosis is acquired through inhalation of the yeast propagules from the environment. C. gattii has been identified as the cause of an emerging infectious disease centered on Vancouver Island, British Columbia, Canada. No cases of C. gattii-disease were diagnosed prior to 1999; the current incidence rate is 36 cases per million population. A search was initiated in 2001 to find the ecological niche of this basidiomycetous yeast. C. gaftii was found in the environment in treed areas of Vancouver Island. The highest percentage of colonized-tree clusters were found around central Vancouver Island, with decreasing rates of colonization to the north and south. Climate, soil and vegetation cover of this area, called the Coastal Douglas fir biogeoclimatic zone, is unique to British Columbia and Canada. The concentration of airborne C. gattii was highest in the dry summer months, and lowest during late fall, winter, and early spring, months which have heavy rainfall. The study of the emerging colonization of this organism and subsequent cases of environmentally acquired disease will be informative in planning public health management of new routes of exposure to exotic agents in areas impacted by changing climate and land use patterns. Cryptococcosis is an infection associated with an encapsulated, basidiomycetous yeast Cryptococcus neoformans. The route of entry for this organism is through the lungs, with possible systemic spread via the circulatory system to the brain and meninges. There are four cryptococcal serogroups associated with disease in humans and animals, distinguished by capsular polysaccharide antigens. Cryptococcus neoformans: variety grubii (serotype A), variety neoformans (serotype D), and variety gattii (serotypes B and C) (Franzot et at. 1999). C. neoformans variety gattii has recently been elevated to species status, C. gattii. C. neoformans val. grubii and var. neoformans have a world-wide distribution, and are particularly associated with soil and weathered bird droppings. In contrast, C. gattii (CG) is not associated with bird excrement, is primarily found in tropical and subtropical climates, and has a restricted environmental niche associated with specific tree species. (Ellis & Pfiffer 1990) Ellis and Pfeiffer theorize that, as a basidiomycete, CG requires an association with a tree in order to become pathogenic to mammals. In Australia, CG has been found to be associated with five species of Eucalypts, Eucalyptus camaldulensis, E. tereticornis, E. blakelyi, E. gomphocephala, and E. rudis. Eucalypts, although originally native to Australia, now have a world-wide distribution. CG has been found associated with imported eucalypts in India, California, Brazil, and Egypt. In addition, in Brazil and Columbia, where eucalypts have been naturalized, native trees have been shown to harbour CG (Callejas et al. 1998; Montenegro et al. 2000). In British Columbia, Canada, since the beginning of 1999, there have been 120 confirmed cases of cryptococcal mycoses associated with CG in humans, including 4 fatalities (data from British Columbia Centre for Disease Control), and over 200 cases in animal pets in BC (data from Central Laboratory for Veterinarians). What is remarkable about the BC outbreak of C. gattii-cryptococcosis is that all of the cases have been residents of, or visitors to, a narrow area along the eastern coast of Vancouver Island, BC, from the tip of the island in the south (Victoria) to Courtenay on the north-central island as illustrated in Figure 1. Of the first 38 human cases, 58% were male with a mean age of 59.7 years (range 20 - 82): 36 cases (95%) were Caucasian. Ten cases (26%) presented with meningitis, the remainder presented with respiratory symptoms. Cultures recovered from cases of cryptococcosis associated with the outbreak were typed as serogroup B, which is specific to CG (Bartlett et al. 2003). This was the first reported outbreak of CVG in Canada, or indeed, the world. Where infection with CG is endemic, for example, Australia, the incidence of cryptococcosis ranges from 1.8 - 4.7 per million between the southern and northern states (Sorrell 2001). However, the overall incidence of cryptococcosis in immunocompenent individuals has been estimated at 0.2 per million population per year (Kwon-Chung et al. 1984). The population of Vancouver Island is approximately 720,000,consequently, even if the organism were endemic, one would expect a maximum of 0.15 cases of cryptococcal disease annually.

  • PDF

Design of Real-Time PreProcessor for Image Enhancement of CMOS Image Sensor (CMOS 이미지 센서의 영상 개선을 위한 실시간 전처리 프로세서의 설계)

  • Jung, Yun-Ho;Lee, Joon-Hwan;Kim, Jae-Seok;Lim, Won-Bae;Hur, Bong-Soo;Kang, Moon-Gi
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.8
    • /
    • pp.62-71
    • /
    • 2001
  • This paper presents a design of the real-time digital image enhancement preprocessor for CMOS image sensor. CMOS image sensor offers various advantages while it provides lower-quality images than CCD does. In order to compensate for the physical limitation of CMOS sensor, the spatially adaptive contrast enhancement algorithm was incorporated into the preprocessor with color interpolation, gamma correction, and automatic exposure control. The efficient hardware architecture for the preprocessor is proposed and was simulated in VHDL. It is composed of about 19K logic gates, which is suitable for low-cost one-chip PC camera. The test system was implemented on Altera Flex EPF10KGC503-3 FPGA chip in real-time mode, and performed successfully.

  • PDF

Characteristics of Humidifier Disinfectant-like Products Containing NaDCC (sodium dichloroisocyanurate) and Their Use in Hospitals (NaDCC (sodium dichloroisocyanurate) 성분 가습기살균제 유사제품의 특성과 의료기관에서의 사용 사례)

  • Jo, Eun-Kyung;Han, Kyunghee;Ju, Min Jae;Yang, Wonho;Cho, Yoon-Hyeong
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.5
    • /
    • pp.495-503
    • /
    • 2020
  • Objective: This study aimed to compare the characteristics of humidifier disinfectant-like products (HD-like products) and humidifier disinfectant products (HD products) and introduce actual cases of the usage of HD-like products in hospitals based on an on-site investigation. Methods: The characteristics, chemical components, and usage of HD-like products (Hichlor or Biospot) and HD products (N-with) containing NaDCC (sodium dichloroisocyanurate) were compared. In the process of conducting the on-site investigation, four hospitals were identified as previously using HD-like products. Each on-site investigation to identify the use of HD-like products was composed of four parts: 1) hospital infection control guidelines, 2) manual for humidifiers in patient's rooms, 3) interviews with nursing staff, infection managers, and purchase managers, 4) searching on the product purchase system. Results: Although HD-like products (Hichlor and Biospot) and HD products (N-with) were sold for different usage purposes, they were all white-colored and coin-shaped foaming tablets with the same chemical component, NaDCC. The manual for using HD-like products and HD products was similar (inserting the tablet in a humidifier container with water). Among the four hospitals, one had used Hichlor in the same manner as HD (N-with) by inserting a tablet in 1L of water in a filled humidifier container and Biospot as a kind of detergent for humidifier container cleaning. Another two hospitals had used Biospot and/or Aniosyme as a kind of detergent for humidifier container cleaning. The other hospital had used unknown product in the same manner as N-with, so we thus assumed it was either an HD products (N-with) or HD-like products (Hichlor, Biospot). Conclusion: This study raises the possibility of the development of adverse health effects similar to exposure to an HD-products when exposed to an HD-like products and the possibility of further use in other medical institutions or multi-use facilities. Therefore, an expansion of the investigation is needed in order to confirm whether there have been similar cases in the past.

Optimization of Curing Treatment and Storage Temperature of Chinese Yam (마의 수확후 처리 및 저장 온도 최적화)

  • Lee, Dong-Suk;Park, Youn-Moon
    • Horticultural Science & Technology
    • /
    • v.31 no.3
    • /
    • pp.289-298
    • /
    • 2013
  • Effects of curing treatments and storage temperature on the quality of Chinese yams (Dioscorea polystachya Turcz.) were investigated stepwise in three consecutive years for the optimization of postharvest handling procedures. Tuberous roots were harvested in early to mid November and cured under ambient or $29^{\circ}C$ heated air conditions for various periods according to the treatment conditions. Storage temperatures in the range of 0.5 to $7.5^{\circ}C$ were phased in to avoid chilling injury while examining storage potential from 4 to 7 months. As poststorage technology, short-term $60^{\circ}C$ hot-air exposure or low shelf temperature treatments were additively imposed. Curing treatments, especially heated air curing for 3-5 days tended to reduce the respiration and weight loss during storage while maintaining flesh firmness. Storage at $0.5^{\circ}C$ brought out typical chilling injury symptoms on the shelf with increases in respiration and lower flesh firmness by tissue breakdown resulting in the rapid loss of marketability. Optimum storage temperature appeared to be the $3-4^{\circ}C$ range which suppresses quality deterioration while avoiding chilling injury. Low shelf temperature seemed to be a necessary part of postharvest handling system to keep marketability through control of poststorage disorders such as rooting and decay. Overall results suggested that optimized postharvest program consisting of heated-air curing, storage at $3-4^{\circ}C$, and low shelf temperature could extend storage potential of Chinese yam to longer than 7 months.