• 제목/요약/키워드: exposure characteristics

검색결과 1,667건 처리시간 0.022초

General Factors of the Korean Exposure Factors Handbook

  • Jang, Jae-Yeon;Kim, So-Yeon;Kim, Sun-Ja;Lee, Kyung-Eun;Cheong, Hae-Kwan;Kim, Eun-Hye;Choi, Kyung-Ho;Kim, Young-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • 제47권1호
    • /
    • pp.7-17
    • /
    • 2014
  • Risk assessment considers the situations and characteristics of the exposure environment and host. Various physiological variables of the human body reflects the characteristics of the population that can directly influence risk exposure. Therefore, identification of exposure factors based on the Korean population is required for appropriate risk assessment. It is expected that a handbook about general exposure factors will be used by professionals in many fields as well as the risk assessors of the health department. The process of developing the exposure factors handbook for the Korean population will be introduced in this article, with a specific focus on the general exposure factors including life expectancy, body weight, surface area, inhalation rates, amount of water intake, and soil ingestion targeting the Korean population. The researchers used national databases including the Life Table and the 2005 Time Use Survey from the National Statistical Office. The anthropometric study of size in Korea used the resources provided by the Korean Agency for Technology and Standards. In addition, direct measurement and questionnaire surveys of representative samples were performed to calculate the inhalation rate, drinking water intake, and soil ingestion.

하계 실내 및 실외환경의 공기 중 휘발성 유기화합물 농도 및 개인노출 (Volatile Organic Compounds Concentrations and Its Personal Exposure in Indoor and Outdoor Environments in Summer)

  • 양원호;손부순;박종안;장봉기;박완모;김윤신;어수미;윤중섭;류인철
    • 한국환경과학회지
    • /
    • 제12권9호
    • /
    • pp.967-976
    • /
    • 2003
  • Volatile organic compounds (VOCs) are present in essentially all natural and synthetic materials from petrol to flowers. In this study, indoor and outdoor VOCs concentrations of houses, offices and internet-cafes were measured and compared simultaneously with personal exposures of each 50 participants in Asan and Seoul, respectively. Also, factors that influence personal VOCs exposure were statistically analyzed using questionnaires in relation to house characteristics, time activities, and health effects. All VOCs concentrations were measured by OVM passive samplers (3M) and analyzed with GC/MS. Target pollutants among VOCs were Toluene, o-Xylene, m/p-Xylene, Ethylbenzene, MIBK, n-Octane, Styrene, Trichloroethylene, and 1,2-Dichlorobenzene. Indoor and outdoor VOCs concentrations measured in Seoul were significantly higher than those in Asan except Ethylbenzene. Residential indoor/outdoor (I/O) ratios for all target compounds ranged from 0.94 to 1.51 and I/O ratios of Asan were a little higher than those of Seoul. Relationship between personal VOCs exposure, and indoor and outdoor VOCs concentrations suggested that time-activity pattern could affect the high exposure to air pollutant. Factors that influence indoor VOCs level and personal exposure with regard to house characteristics in houses were building age, inside smoking and house type. In addition insecticide and cosmetics interestingly affected the VOCs personal exposure. Higher exposure to VOCs might be caused to be exciting increase and memory reduction, considering the relationship between measured VOCs concentrations and questionnaire (p<0.05).

LCD 제조공정의 이온화 장치에 대한 전리방사선 지역노출특성 분석 (Analysis of Local Exposure Levels of Radiation Emitted from Soft X-ray Ionizers in LCD Manufacturing Processes)

  • 김준범;정은교;정기효
    • 한국산업보건학회지
    • /
    • 제31권4호
    • /
    • pp.342-352
    • /
    • 2021
  • Objectives: This study analyzed the local exposure levels of radiation emitted from the equipment with soft X-ray ionizers to investigate the radiation exposure levels in Liquid Crystal Display(LCD) manufacturing processes. Methods: This study measured the local radiation levels for the equipment installed in two LCD manufacturing companies. The equipment were installed at diverse processes and equipped with various number of ionizers. The local radiation levels were measured on the surface of the equipment by using direct reading equipment, and the measurements were converted into annual effective dose by considering the radiation exposure time of workers. Statistical analyses were performed to investigate the radiation exposure characteristics. Results: Annual effective doses for 97.6% of the equipment being measured were less than 1 mSv. However, the range of annual effective doses was 0.004 mSv ~ 2.167 mSv, which indicated a large variation among the equipment. Statistical analyses of the study found that this large variation was raised due to improper shielding of the equipment rather than process and/or equipment characteristics. To pinpoint the cause of this large variation in annual effective dose, this study improved the shielding of the equipment being radiated over 1 mSv and found that their average effective dose was reduced from 1.604 mSv to 0.126 mSv after shielding improvement. Conclusions: Relatively high exposure levels of radiation were observed in some equipment where their shielding were insufficiently thick and/or sealed. This finding implies that the shielding of the equipment is an important engineering countermeasure to control the radiation exposure levels in industries.

엑스선의 조사시간에 따른 형광유리선량계의 빌드업 특성 (Buildup Characteristics of Radiophotoluminescent Glass Dosimeters with Exposure Time of X-ray)

  • 권대철
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권5호
    • /
    • pp.256-263
    • /
    • 2017
  • By using the buildup characteristics of the radiophotoluminescence glass dosimeter(RPLGD), it is aimed to help the measurement of the accurate dose by measuring the radiation dose according to the time of the glass element. Five glass elements were arranged on the table and the source to image receptor distance(SID) was set to 100 cm for the build-up radiation dose measurement of the fluorescent glass dosimeter glass element(GD-352M). Radiation doses and saturation rates were measured over time according to irradiation time, with the tube voltage (30, 60, 90 kVp) and tube current (50, 100 mAs) Repeatability test was repeated ten times to measure the coefficient of variation. The radiation dose increased from 0.182 mGy to 12.902 mGy and the saturation rate increased from 58.3% with increasing exposure condition and time. The coefficient of variation of the glass elements of the fluorescent glass dosimeter was ranged from 0.2 to 0.77 according to the X - ray exposure conditions. X - ray exposure showed that the radiation dose and saturation rate were increased with buildup characteristics, and degeneration of glass elements was not observed. The reproducibility of the variation coefficient of the radiation generator was included within the error range and the reproducibility of the radiation dose was excellent.

새로운 이온빔장치를 사용한 Twisted Nematic-LCD의 전기광학특성 (Electro-optical Characteristics of Twisted Nematic(TN)-LCD using New Ion Beam Equipment)

  • 김상훈;황정연;장미혜;김귀열;서대식
    • 한국전기전자재료학회논문지
    • /
    • 제19권6호
    • /
    • pp.547-551
    • /
    • 2006
  • We studied liquid crystal (LC) alignment with ion beam (IB) on polyimide and electro-optical characteristics of twisted nematic (TN)-liquid crystal display (LCD) on the polyimide surface using obliquely ion beam (IB) exposure with new IB type equipment. A good uniform alignment of the nematic liquid crystal (NLC) alignment with the ion beam exposure on the polyimide surface was observed. In addition, it can be achieved the good EO properties of the ion-beam-aligned TN-LCD on polyimide surface. Also, the EO characteristics of the ion-beam-aligned TN-LCD on a polyimide (PI) surface with ion beam exposure using new type IB equipment is same or more superior than ion-beam-aligned TN-LCD on a polyimide (PI) surface with ion beam exposure using Kaufman-type Ar ion gun.

Ti-6Al-4V 합금의 단시간 고온 노출 시 모재 및 용접부의 인장강도 특성 (Effects on Tensile Strength of Base and Weld Metal of Ti-6Al-4V Alloy in Short Time Exposure to High Temperature)

  • 채병찬
    • 한국군사과학기술학회지
    • /
    • 제17권4호
    • /
    • pp.413-421
    • /
    • 2014
  • Since the structural temperature of a flight vehicle flying at high speed rises rapidly due to aerodynamic heating, it is necessary for optimum structural design to obtain proper material properties at high temperature by taking into account of its operational environment. For a special alloy, analysis data on strength change due to exposure time to high temperature are very limited, and most of them are for an exposure time longer than 30 minutes for long term operations. In this study, base and weld metal samples of Ti-6Al-4V alloy had been prepared and high temperature tensile tests with induction heating were performed, and then high temperature strength characteristics and strength recovery characteristics through cooling have been analyzed. Pre-tests to determine maximum heating rate were performed, and response characteristics for temperature control were confirmed. As a result, high temperature tensile strength appeared to be lower than that of room temperature, but it was higher than that of high temperature of 30 minite exposure listed in MMPDS. In strength recovery through cooling Ti-6Al-4V alloy has shown higher recovery rate compared with other alloys.

산화알루미늄 섬유와 니켈분말 후처리공정에서 입자의 노출특성 (Exposure Characteristics of Particles during the After-treatment Processes of Aluminum Oxide Fibers and Nickel Powders)

  • 김종범;김경환;류성희;윤성택;배귀남
    • 한국산업보건학회지
    • /
    • 제26권2호
    • /
    • pp.225-236
    • /
    • 2016
  • Objectives: Nanomaterials have been used in various fields. As use of nanoproducts is increasing, workers dealing with nanomaterials are also gradually increasing. Exposure assessments for nanomaterials have been carried out for protection of worker's health in workplace. Exposure studies were mainly focused on manufacturing processes, but these studies on after-treatment processes such as refinement, weighing, and packing were insufficient. So, we investigated exposure characteristics of particles during after-treatment processes of $Al_2O_3$ fibers and Ni powders. Methods: Mass-production of Ni powder process was carried out in enclosed capture-type canopy hood. In a developing stage, $Al_2O_3$ was handled with a local ventilation unit. Exposure characteristics of particles were investigated for $Al_2O_3$ fiber and Ni powder processes during the periods of 10:00 to 16:00, 20 May 2014 and 13:00 to 16:00, 21 May 2014, respectively. Three real-time aerosol instruments were utilized in exposure assessment. A scanning mobility particle sizer(SMPS, nanoscan, model 3910, TSI) and an optical particle counter(OPC, portable aerosol spectrometer, model 1.109, Grimm) were used to determine the particle size distribution in the size range of 10-420 nm and $0.25-32{\mu}m$, respectively. In addition, a nanoparticle aerosol monitor(NAM, model 9000, TSI) was used to measure lung-deposited nanoparticle surface area. Membrane filters(isopore membrane filter, pore size of 100 nm) were also used for air sampling for the FE-SEM(model S-5000H, Hitachi) analysis using a personal sampling pump(model GilAir Plus by 2.5 L/min, Gilian). Conclusions: For Ni powder after-treatment process, only 27% increase in particle concentration was found during the process. However, for $Al_2O_3$ fiber after-treatment process, significant exposure(1.56-3.34 times) was observed during the process.

가습기 살균제 건강 피해 조사에서 노출 평가 방법 고찰 (A Strategy for Exposure Assessment of Humidifier Disinfectant Associated to Health Effects)

  • 박동욱
    • 한국환경보건학회지
    • /
    • 제44권2호
    • /
    • pp.107-114
    • /
    • 2018
  • Objectives: The objectives of this study are to describe strategy for exposure assessment of humidifier disinfectant (HD) used in the national program to associate the use of HD with lung injury. Methods: Strategy and method employed to evaluate HD use characteristics were developed to associate health effects including HD associated with lung injury (HDLI). We developed HD-specific questionnaire to assess potential HD exposure, which was consistently used in the national program. Trained environmental health scientists visited the residences of registered subjects and investigated HD use characteristics. Results: Major HD exposure related variables were type of HD brand/s used; HD volume added to the humidifier, frequency of HD addition, and time spent in room/s with the humidifier; duration of HD use in the household in average months/year, weeks/month, and days/week; average sleeping hours in a room with an operating humidifier containing a disinfectant; number of HD brands used and type of HD; average distance of the bed from the humidifier in meters. Conclusions: We concluded that estimated airborne HD concentration was significantly associated with the risk of HDLI.

a-C:H 박막표면에 UV 배향법을 이용한 TN 셀의 전기광학특성 (Electro-Optical Characteristics of TN Cell using UV Alignment Method on the a-C:H Thin Film)

  • 박창준;황정연;김종환;서대식;안한진;백홍구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1043-1046
    • /
    • 2003
  • We investigated the EO performances of the UV aligned twisted nematic liquid crystal display (TN-LCD) with the UV exposure on a-C:H thin film surface. LC alignment using UV exposure on the a-C:H thin film surface was achieved. Monodomain alignment of the UV aligned TN-LCD can be observed. An good EO characteristics of the UV aligned TN-LCD was observed with oblique ion beam exposure on the a-C:H thin film surface. Therefore, the EO property of the UV-aligned TN-LCD with UV exposure on the a-C:H thin film surface is almost the same as that of the rubbing-aligned TN-LCD on a polyimide (PI) surface.

  • PDF

대학생의 음란물 노출력과 성태도 및 성경험간의 상관성 분석 (Correlation between History of Exposure to Obscene Material, Sexual Attitudes and Intercourse Experience among University Students)

  • 김은만;유수정;송미령
    • 기본간호학회지
    • /
    • 제20권1호
    • /
    • pp.18-26
    • /
    • 2013
  • Purpose: The purpose of this study was to analyze the history of exposure to obscene material, and examine sexual attitudes and intercourse experience in order to develop an effective program for university students. Method: The data were collected in May, 2012 from 385 students attending 3 universities in Korea. An independent t-test and ANOVA were used to determine the differences with regard to sexual attitudes and intercourse experience according to general characteristics and history of exposure to obscene material. Results: Sexual attitudes significantly differed according to timing of first exposure to obscene material (p<.001). Intercourse experience was significantly different according to timing of first exposure to obscene material (p=.016) and type of exposure to obscene material (p=.032). There was a negative correlation between first exposure to obscene material and sexual attitudes (p<.001), and a positive correlation between first exposure to obscene material and intercourse experience (p=.017). Conclusion: Results of this study indicate that history of exposure to obscene material should be considered as an important variable in managing the sexual health of university students.