• 제목/요약/키워드: explosion energy

검색결과 402건 처리시간 0.026초

수중폭발 이론을 사용한 노심폭주사고 시 노심 팽창 및 에너지 거동 수치해석 (NUMERICAL ANALYSIS ON THE REACTOR CORE EXPANSION AND ENERGY BEHAVIORS DURING CDA USING UNDERWATER EXPLOSION THEORY)

  • 강석훈
    • 한국전산유체공학회지
    • /
    • 제21권3호
    • /
    • pp.8-14
    • /
    • 2016
  • A numerical analysis is conducted to estimate the core expansion and the energy behaviors induced by a core disruptive accident in a sodium-cooled fast reactor. The numerical formulation based on underwater explosion theory is carried out to simulate the core explosion inside the reactor vessel. The transient pressure, temperature and expansion of the core are examined by solving the equation of state and nonlinear governing equation of momentum conservation in one-dimensional spherical coordinates. The energy balance inside the computation domain is examined during the core expansion process. Heat transfer between the core and the sodium coolant, and the bubble rise during the expansion process are briefly investigated.

압력배출구를 설치한 전동화 차량 배터리 시험실의 내부 폭압 평가 (Evaluation of Internal Blast Overpressures in Test Rooms of Elcetric Vehicles Battery with Pressure Relief Vents)

  • 방승기;신진원;정현진
    • 한국지열·수열에너지학회논문집
    • /
    • 제18권3호
    • /
    • pp.7-18
    • /
    • 2022
  • Secondary batteries used in electric vehicles have a potential risk of ignition and explosion. Various safety measures are being taken to prevent these risks. A numerical study was performed using a computational fluid dynamics code on the cases where pressure relief vents that can reduce the blast overpressures of batteries were installed in the through-compression test room, short-circuit drop test room, combustion test room, and immersion test room in facilities rleated to battery used in electric vehicles. This study was conducted using the weight of TNT equivalent to the energy release from the battery, where the the thermal runaway energy was set to 324,000 kJ for the capacity of the lithium-ion battery was 90 kWh and the state of charge (SOC) of the battery of 100%. The explosion energy of TNT (△HTNT) generally has a range of 4,437 to 4,765 kJ/kg, and a value of 4,500 kJ/kg was thus used in this study. The dimensionless explosion efficiency coefficient was defined as 15% assuming the most unfavorable condition, and the TNT equivalent mass was calculated to be 11 kg. The internal explosion generated in a test room shows the very complex propagation behavior of blast waves. The shock wave generated after the explosion creates reflected shock waves on all inner surfaces. If the internally reflected shock waves are not effectively released to the outside, the overpressures inside are increased or maintained due to the continuous reflection and superposition from the inside for a long time. Blast simulations for internal explosion targeting four test rooms with pressure relief vents installed were herein conducted. It was found that that the maximum blast overpressure of 34.69 bar occurred on the rear wall of the immersion test room, and the smallest blast overpressure was calculated to be 3.58 bar on the side wall of the short-circuit drop test room.

HCNG 혼합연료의 폭발 위험 특성 분석 (Analysis on the Explosion Risk Characteristic of Hydrogen blended Natural Gas)

  • 강승규;김영구;권정락
    • 에너지공학
    • /
    • 제23권4호
    • /
    • pp.223-229
    • /
    • 2014
  • 본 연구는 시뮬레이션 툴을 이용해 HCNG 연료의 폭발 특성에 대하여 고찰하였다. 충전소의 대량 가스누출로 인한 증기운 폭발과 저장용기 폭발에 의한 피해 범위를 예측하였다. HCNG 충전소에서 증기운 폭발이 발생할 경우 충전소 내부에 50~200kPa의 폭발압력이 형성되었다. 저장용기가 폭발할 경우 수소의 경우 과압이 미치는 거리는 59m, 복사열이 미치는 거리는 75m로 측정되었다. CNG의 경우 과압이 미치는 거리는 89m, 복사열이 미치는 거리는 144m로 예측되었다. 수소와 CNG를 혼합한 30%HCNG의 경우 과압이 미치는 거리는 81m, 복사열이 미치는 거리는 130m로 예측되었다. 폭발과압 및 복사열이 미치는 피해거리는 CNG가 가장 높게 나타났으며 HCNG는 CNG와 수소의 사이에 위치하였다.

수소 취급설비의 누출원에 인접한 방폭전기기기의 가스그룹 IIC 기기 회피 방안에 관한 연구 (A Study on the Method to Avoid the Gas Group IIC Equipment of Explosion Proof Electrical Equipment Adjacent to the Source of Release of Hydrogen Handling Facility)

  • 변윤섭
    • 한국수소및신에너지학회논문집
    • /
    • 제33권4호
    • /
    • pp.383-390
    • /
    • 2022
  • Appropriate explosion proof electrical equipment should be installed in hazardous areas. In areas where hydrogen is handled, explosion proof electrical equipment adjacent to the hydrogen handing facility must be reviewed for selection of gas group IIC (or IIB+H2) equipment. When selecting explosion proof electrical equipment for the flammable substance handling facility in areas where hydrogen and flammable substance are handled, the method to avoid gas group IIC (or IIB+H2) equipment has been suggested by using the operating pressure of the hydrogen handling facility. When the operating pressure of the outdoor hydrogen handling facility is 1.065 MPa or less, it has been confirmed that there is no need to install gas group IIC (or IIB+H2) equipment for the flammable substance handling facility adjacent to the hydrogen handling facility. And the method of selecting explosion proof electrical equipment for the flammable substance handling facility has been suggested as a flowchart, so it will be able to be utilized when selecting appropriate explosion proof electrical equipment.

An Assessment of Reactor Vessel Integrity Under In-Vessel Vapor Explosion Loads

  • Bang, Kwang-Hyun;Cho, Jong-Rae;Park, Soo-Yong
    • Nuclear Engineering and Technology
    • /
    • 제32권4호
    • /
    • pp.299-308
    • /
    • 2000
  • A safety assessment of reactor vessel lower head integrity under in-vessel vapor explosion loads has been performed. The core melt relocation parameters were chosen within the ranges of physically realizable bounds. The premixing and explosion calculations were performed using TRACER-II code. Using the calculated explosion pressures imposed on the lower head inner wall, strain calculations were peformed using ANSYS code. Then, the calculated strain results and the established failure criteria were used in determining the failure probability of the lower head, In the explosion analyses, it is shown that the explosion impulses are not altered significantly by the uncertain parameters of triggering location and time, fuel and vapor volume fractions in uniform premixture bounding calculations. Strain analyses show that the vapor explosion-induced lower head failure is not possible under the present framework of assessment. The result of static analysis using the conservative explosion-end pressure of 50 MPa also supports the conclusion. It is recommended, however, that an assessment of fracture mechanics for preexisting cracks be also considered to obtain a more concrete conclusion.

  • PDF

수소생산시설에서의 수소폭발의 안전성평가 방법론 연구 (A Study on Methodology of Assessment for Hydrogen Explosion in Hydrogen Production Facility)

  • 제무성;정건효;이현우;이원재;한석중
    • 한국수소및신에너지학회논문집
    • /
    • 제19권3호
    • /
    • pp.239-247
    • /
    • 2008
  • Hydrogen production facility using very high temperature gas cooled reactor lies in situation of high temperature and corrosion which makes hydrogen release easily. In that case of hydrogen release, there lies a danger of explosion. However, from the point of thermal-hydraulics view, the long distance of them makes lower efficiency result. In this study, therefore, outlines of hydrogen production using nuclear energy are researched. Several methods for analyzing the effects of hydrogen explosion upon high temperature gas cooled reactor are reviewed. Reliability physics model which is appropriate for assessment is used. Using this model, leakage probability, rupture probability and structure failure probability of very high temperature gas cooled reactor are evaluated and classified by detonation volume and distance. Also based on standard safety criteria which is value of $1{\times}10^{-6}$, safety distance between the very high temperature gas cooled reactor and the hydrogen production facility is calculated.

테레프탈산의 분진 폭발특성에 관한 연구 (A Study on Explosion Characteristics of Terephthalic Acid)

  • 목연수;장성록
    • 한국안전학회지
    • /
    • 제15권1호
    • /
    • pp.121-125
    • /
    • 2000
  • This study was executed by dust explosion experiment of terephthalic acid which was widely used for various purposes of food packing material and film etc. and the demand was rapidly increasing. The particle size and concentration of dust affected the minimum ignition energy largely and the lean concentration and the minimum ignition energy in the range of this study were obtained 50$g/m^3$ and 19mJ respectively. Minimum ignition energy was shown at the 4 and 5mm gap distance of discharge electrode, and when the gap distance was below 2mm the explosion could not generated although the sufficient energy was given. It was also found that the ignition energy decreased linearly with the decreasing of dust mean particle size.

  • PDF

사료분진의 폭발특성에 관한 연구 (A study of flour dust explosion)

  • 이홍주;우인성;홍현경;사민형;김윤선;황명환;황성민;박희철;이주엽
    • 대한안전경영과학회지
    • /
    • 제13권4호
    • /
    • pp.109-116
    • /
    • 2011
  • This study examined into property of flour dust explosion to get the basic data for safety of industry by protecting accident of dust explosion. The experiment was conducted to know the effect of distance between explodes in the experiment device, effect of flour dust concentration, effect of humidity, effect of explosion pressure to the dust concentration and effect of inactive substance additive. The study indicated that explosion was happened effectively at the optimum distance 100mm or less in inter-polar distance, and minimum ignition energy was measured at 6mm. The data of feed concentration to the probability of explosion showed that the smaller the particle diameter was, the larger probability of explosion was, and the higher the dust concentration was, the more increased the pressure of explosion was, but more than upper limit of dust concentration, then the explosion of pressure decreased. For the effect of humidity, the more it contained water, the more decreased the ignition energy of dust was, so increased minimum explosive concentration, and effective water content was minimum 10% or more. Inactive substance additive was effective in adding more than 15% CaCO3 and CaO as substance inhibiting dust explosion, in which CaCO3 was more effective than CaO. the analysis of the flame of dust explosion was performed by high-speed video camera, it showed the size of flame bacame smaller in order that sub feed, main feed, wheat powder. As a result, sub feed was expected to be less dangerous than others.

Near-explosion protection method of π-section reinforced concrete beam

  • Sun, Qixin;Liu, Chao
    • Geomechanics and Engineering
    • /
    • 제28권3호
    • /
    • pp.209-224
    • /
    • 2022
  • In this study, the numerical analysis model of π-beam explosion is established to compare and analyze the failure modes of the π-beam under the action of explosive loads, thus verifying the accuracy of the numerical model. Then, based on the numerical analysis of different protection forms of π beams under explosive loads, the peak pressure of π beam under different protection conditions, the law of structural energy consumption, the damage pattern of the π beam after protection, and the protection efficiency of different protective layers was studied. The testing results indicate that the pressure peak of π beam is relatively small under the combined protection of steel plate and aluminum foam, and the peak value of pressure decays quickly along the beam longitudinal. Besides, as the longitudinal distance increases, the pressure peak attenuates most heavily on the roof's explosion-facing surface. Meanwhile, the combined protective layer has a strong energy consumption capacity, the energy consumed accounts for 90% of the three parts of the π beam (concrete, steel, and protective layer). The damaged area of π beam is relatively small under the combined protection of steel plate and aluminum foam. We also calculate the protection efficiency of π beams under different protection conditions using the maximum spalling area of concrete. The results show that the protective efficiency of the combined protective layer is 45%, demonstrating a relatively good protective ability.

MULTIPLE SUPERNOVA EXPLOSIONS INSIDE A WIND-BLOWN BUBBLE

  • Cho, Hyun-Jin;Kang, Hye-Sung
    • 천문학회지
    • /
    • 제40권4호
    • /
    • pp.161-164
    • /
    • 2007
  • We calculate the evolution of multiple supernova (SN) explosions inside a pre-exiting bubble blown up by winds from massive stars, using one-dimensional hydrodynamic simulations including radiative cooling and thermal conduction effects. First, the development of the wind bubble driven by collective winds from multiple stars during the main sequence is calculated. Then multiple SN explosion is loaded at the center of the bubble and the evolution of the SN remnant is followed for $10^6$ years. We find the size and mass of the SN-driven shell depend on the structure of the pre-existing wind bubble as well as the total SN explosion energy. Most of the explosion energy is lost via radiative cooling, while about 10% remains as kinetic energy and less than 10% as thermal energy of the expanding bubble shell. Thus the photoionization and heating by diffuse radiation emitted by the shock heated gas is the most dominant form of SN feedback into the surrounding interstellar medium.