• Title/Summary/Keyword: experimental plot

Search Result 616, Processing Time 0.024 seconds

Statistical Efficiency of Sampling Plot Size in Half-sib Progeny Test of Korean Pine (Pinus koraiensis S. et Z.) (잣나무 차대검정(次代檢定)에 있어서의 효율적(效率的)인 Plot Sampling에 관(關)한 연구(硏究))

  • Kim, Dae Eun;Chon, Sang Keun
    • Journal of Korean Society of Forest Science
    • /
    • v.80 no.4
    • /
    • pp.379-382
    • /
    • 1991
  • Tree height at age 10 was used to estimate the statistical efficiencies of sampling size in the progeny test of Pinus koraiensis S. et Z. Experimental design was RCB design which consists of 25 half-sib families in each of three blocks. The number of families and blocks were fixed, therefore, the number of trees sampled per plot was the only factor that influences the environmental portion of the family mean height. Coefficient of variation, the estimate of the standard error of the family mean height, decreased with increase of sampling plot size, and became stable from 4-tree plot sampling (6.97%). The experimental error was significant from 7-tree sampling plot size. Nonlinear relationship (${\hat{Y}}=10.425e-^{0.073x}$ ; $R^2$=0.840) was found between the sampling plot size and the standard error of family mean height.

  • PDF

Development of Experimental Gain Tuning Technique for Multi-Axis Servo System (다축 서보 시스템의 Gain Tuning에 관한 연구)

  • Chung W.J.;Kim H.G.;Seo Y.G.;Lee K.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.271-272
    • /
    • 2006
  • This paper presented a new experimental gain tuning technique for a Multi-Axis Servo System. First, the investigation for proportional gain of velocity control loop by using a Dynamic Signal Analyzer (DSA) was performed. Using the FUNCTION characteristic of DSA based on the Bode plot, the Bode plot of open loop transfer function was obtained. In turn, the integral gain of a servo controller can be found out by using the Integration time constant extracted from the Bode plot of open loop transfer function. In the meanwhile, the positional gain of the servo controller has been obtained by using the Bode plot of the closed loop transfer function. We have also proposed the technique to find out an optimal parameter of a notch filter, which has a great influence on vibration reduction, by using the damping factor extracted from the Bode plot of closed loop transfer function.

  • PDF

Experimental Study on Heat Transfer Characteristics for Single-phase Flow in Plate & Shell Heat Exchangers by Using Wilson Plot Method (Wilson plot법을 이용한 Plate & Shell 열교환기의 단상유동 열전달 특성에 관한 실험적 연구)

  • Seo, M.K.;Kim, Y.S.;Lee, S.K.
    • Journal of Power System Engineering
    • /
    • v.3 no.4
    • /
    • pp.22-27
    • /
    • 1999
  • Single phase heat transfer coefficients were measured for turbulent water flow in a plate & shell heat exchangers by using Wilson plot method. An experiment for counterflow heat exchange between the plate and shell was performed. The shell side heat transfer resistance was varied and the overall heat transfer coefficients were measured. The single-phase heat transfer coefficients in a plate side were obtained by Wilson plot method. Single-phase heat transfer correlations based on projected heat transfer area have been proposed for a plate & shell heat exchanger.

  • PDF

Effects of Forest Practices on the Changes of Characteristics of Forest Stand, Mesopore Ratio and Soil Water Contents in Pinus koraiensis Stands (산림시업이 잣나무림의 생장, 토양조공극 및 토양함수능에 미치는 영향)

  • Jun, Jaehong;Jeong, Yongho;Choi, Hyung Tae;Yoo, Jae-Yun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.11 no.3
    • /
    • pp.20-27
    • /
    • 2008
  • This study was conducted to investigate the influence of thinning and pruning on characteristics of forest stand, mesopore ratio and soil water content at the Pinus koraiensis stands in Gwangneung, Gyeonggido. The Pinus koraiensis had been planted in 1976 and thinning and pruning were carried out in 1996. A sample area survey was conducted at experimental plots (thinned and unthinned) in 1998 and 2005, and mesopore ratio and soil water content have been monitored from 2000 to present. Average tree height of the thinned plot increased from 10.9m to 13.2m and from 10.3m to 12.8m for the unthinned plot. Average D.B.H of the thinned plot increased from 15.9cm to 21.1cm and from 14.5cm to 16.7cm for the unthinned plot during the period 1998-2005. Crown density at the thinned plot increased from 81.5% to 95.0% and from 89.5% to 95.0% for the unthinned plot during the period 1998-2005. Mesopore ratio (pF2.7) of A layer soil at the thinned plot was 40.1% while that of the unthinned plot was 37.3%. Changes of mesopore ratio at unthinned plot were not associated with stand age, but those at thinned plot had increased and then decreased, showing declining of the practice effect. Average soil water content at the thinned plot were 23.7% and 22.4% for the unthinned plot. Soil watercontents at both plots have been increased with increase in stand age. But the difference of soil watercontent at each plot has been decreased, especially at the depth of 10cm.

Study on Optimum Sizes of Experimental Units

  • Chang, Suk-Hwan
    • Journal of the Korean Data and Information Science Society
    • /
    • v.14 no.2
    • /
    • pp.201-208
    • /
    • 2003
  • Since no information about the optimum plot sizes on field experiments on the major food crops in Korea is available, present status of plot sizes being used by the research institutes was examined for rice, barley & wheet, soybean, potatoes, red pepper, garlic and onion. The optimum plot sizes in field experiments on these crops were estimated on the basis of soil fertility indices (Smith's regression coefficients) that Chang (1983) reported.

  • PDF

Measurement of Heat Transfer Coefficient in a Flooded Evaporator through Wilson Plot Method (Wilson Plot을 이용한 만액식 증발기의 열전달계수 측정)

  • 윤필현;강용태;정진희
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.8
    • /
    • pp.698-706
    • /
    • 2004
  • Heat transfer coefficients of enhanced tubes in a flooded evaporator are measured through Wilson Plot method. And the correlations are proposed to design a flooded evaporators. Overall heat transfer coefficients are composed of the heat transfer coefficients both inside and outside tubes. Usually the experiments have been conducted separately. But there have been many difficulties like setting up the equipments and measuring the wall temperature. Wilson Plot method makes it possible to measure the separated transfer coefficients at the same equipment through experimental skills. So the cost and time can be reduced. And the results are reliable enough to use for design. Heat transfer coefficients inside the tube were able to be correlated uniquely in spite of various outside conditions. Boiling heat transfer of R134a is more dependent on the saturation temperature and much higher than that of R123.

Studies on the Effect of Soil Conservation According to the Direction of Furrows in the Slope Land. (경사지밭에있어 이랑방향이 농지보전에 미치는 영향)

  • 한욱동
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.11 no.3
    • /
    • pp.1719-1723
    • /
    • 1969
  • In this country, farmers lay out furrows in the direction which is considered by their own judgement to be convenient for cultivation without paying much attention for soil erosion. The direction of furrow has considerable effects on soil and water losses. In this experiment, it is intedned to observe the differences of soil and water losses in different directions of furrows of sloped fields so that the results thus obtained could be informed to farmers who should be careful in determining furrow direction for soil erosion control. Some the major experimental results are summarized as follows: The direction of furrows did not affect so much on the runoffs in a gentle slope, as the runoff is 509 ton/10a in the contouring plot, $51^{\circ}$/ton/10a in the 45-degree plot, and 560 ton/10a in the up-and-down hill plot. The contouring plot among the three plots had best effect on soil conservation, as the soil losses are 5.8 ton/10a in the contouring plot, 9.3 ton/10a in the 45 degree plot, and 10.2 ton/10a in the up-and-down hill plot.

  • PDF

Characteristics of Non-Point Sources Pollutant Loads at Paddy Plot Located at the Valley Watershed during Irrigation Periods (관개기 곡간지 유역 필지논에서의 비점원오염물질 유출특성)

  • Han, Kuk-Heon
    • KCID journal
    • /
    • v.18 no.1
    • /
    • pp.94-102
    • /
    • 2011
  • The aim of this study was to evaluate the load of non-point sources pollutant at a paddy plot located at the valley watershed during irrigation period. Irrigation, runoff and water quality data in the paddy plot were analyzed periodically from June 1 to October 31 in 2005. The observed amount of precipitation, irrigation, runoff for the experimental paddy plot during the irrigation period was 1,297.8, 223.2, and 825.4mm, respectively. Total-N concentrations ranged from 3.73 to 18.10mg/L, which was generally higher than the quality standard of agricultural water (1.0mg/L). Total-P concentrations ranged from 0.111 to 0.243mg/L and the average was 0.139mg/L. The observed runoff pollutants loadings from the paddy plot were measured as 34.4 kg/ha for T-N, 1.0 kg/ha for T-P and 213.8 kg/ha for SS. The non-point sources pollutant load in drainage water depends on rainfall and surface drainage water amount from the paddy plot. We are considering that these results were affected by rainfall as well as hydrological condition, soil management, whether or not fertilizer application, cropping, rice straw and plowing.

  • PDF

Projection analysis for split-plot data (분할구자료의 사영분석)

  • Choi, Jaesung
    • The Korean Journal of Applied Statistics
    • /
    • v.30 no.3
    • /
    • pp.335-344
    • /
    • 2017
  • This paper discusses a method of analyzing data from split-plot experiments by projections. The assumed model for data has two experimental errors due to two different experimental sizes and some random components in treatment effects. Residual random models are constructed to obtain sums of squares due to random effects. Expectations of sums of squares are obtained by Hartley's synthesis. Estimable functions of fixed effects are discussed.

A Study on the Dry Matter Production and Growth Analysis of Zoysia japonica (잔디의 물질생산과 성장해석에 관한 연구)

  • Jin, AHee Sung;Joon Huh
    • The Korean Journal of Ecology
    • /
    • v.9 no.3
    • /
    • pp.161-184
    • /
    • 1986
  • An experiment was made in order to analyze the growth characteristics and productivity of Zoysia japonica under control, mowing and TIBA treatment conditions at the experimental farm of Kyung Hee univ. from May 26 to Oct. 1 in 1985. The field was planned by the randomized block design method and each treatment was given to three plots (2${\times}$2, 4${\times}$4 and 10${\times}$10 cm) and was replicated three times. Each plot was 1$m^2$ for Zoysia japonica. The sampling of each plot was taken once a week after sowing. In order to know the dry matter of total standing crops, kept 9$0^{\circ}C$ and weighted each organ of the plants. Total leaf area of a plant was measured by drawing method. The author adopted the growth analysis of English School. The increasing rates of numbers of leaf and stem were remarkably high in each plot between 10th and 12th weak after sowing and it was highest in TIBA treated plot. The increasin rate of leaf area in each plot was remarkably high beween 10th and 12th week and the maximum value of leaf area was 274.00c$m^2$ in TIBA treated plot of 100 plants/$m^2$. The increasing rate of standing crop was remarkably high between 10th and 12th week and the high increasing tendency in TIBA plot resulted from TIBA. The positive correlationship was founded between standing crop and leaf area. The evaporation rather than temperature acted as a main factor of negative correlation with standing crop during the experiment period. Solar radiation had a high positive correlation in the lower density of plot. C/F ratio was low, during the growth period, from 10th to 12th week after sowing and was low in the higher density under each treated plot. T/R ratio was not constant during the sampling period but was high in the lower density. The increasing rates of RGR and NAR were high between 11th and 12th week after sowing. Leaf area ratio was high in higher density in each plot and not constant in all treated plot.

  • PDF