• 제목/요약/키워드: experimental greenhouse

검색결과 297건 처리시간 0.024초

시설재배 토양의 수분 조절을 위한 자동 수분제어시스템 개발 (Development of an Automatic Water Control System for Greenhouse Soil Water Content Management)

  • 이동훈;이규승;장영창
    • Journal of Biosystems Engineering
    • /
    • 제33권2호
    • /
    • pp.115-123
    • /
    • 2008
  • This study was conducted to develop an automatic soil water content control system for greenhouse, which consisted of drip irrigation nozzles, soil water content sensors, an on/off valve, a servo-motor assembly and a control program. The control logic adopted in the system was Ziegler-Nichols algorithm and rising time, time constant and over/undershoot ratio as control variables in the system was selected and determined by various control experiments to maintain small delay time and low overshoot. Based on the experimental results, it was concluded that the control system developed in the study could replace the unreliable conventional greenhouse soil water management.

온풍난방을 채용한 3연동 플라스틱 하우스의 실내공기용적 변화가 하우스 온열환경에 미치는 영향 (Influence on the Thermal Environment by Change of Indoor-air Volume of Plastic Greenhouse with Hot Air Heating Systems)

  • 전삼채;이창수;나수연;허종철;최동호
    • 한국태양에너지학회 논문집
    • /
    • 제22권3호
    • /
    • pp.1-10
    • /
    • 2002
  • Relatively being economical in installation and easy in operation, hot-air heating system has been generally used in greenhouse for heating system regardless of high cost in maintenance and uneven distribution of air temperature. Therefore to overcome the disadvantages in maintenance and in distribution of air temperature and to improve efficiency of heating system, this experimental study is performed. This experimental study aims to improve the character of uneven temperature distribution in vertical direction and to reduce energy consumption for heating in a greenhouse. The experiment had been performed to investigate change of thermal environment and effects on reducing energy consumption for heating in greenhouse by additional surface insulation and reduction of indoor-air volume that come by installing transparent vinyl membranes with different height in each house. The results show that there is a wide difference in oil-energy consumption between houses according to condition of surface insulation and change of indoor-air volume. Furthermore, the results show that the efficiency of dual surface is higher than that of change of indoor-air volume in terms of energy saving.

온실의 열을 이용한 저에너지하우스의 패시브 난방 효과 분석 (An Analysis on Effects of Passive Heating of Low Energy House Using Heat in Greenhouse)

  • 유동완;이태구
    • KIEAE Journal
    • /
    • 제16권5호
    • /
    • pp.103-109
    • /
    • 2016
  • Purpose: In Korea, to reduce greenhouse gas emissions, energy performance standard of buildings is being reinforced with goals of Passive House until 2017 and Zero Energy House until 2025 in order to reduce emissions from buildings which constitute a quarter of greenhouse gas emissions. In order to achieve the target of Zero Energy House, it is certainly necessary to develop renewable energy that can replace cooling and heating energy occupying a significant amount of building energy consumption after increasing the energy performance firstly. Method: In this study, effects of heat in greenhouse heated by solar heating on indoor heating were analyzed by constructing a greenhouse in front of the Low Energy Building. Result: As a result, indoor temperature was increased by peak average $27.8^{\circ}C$, peak average $6.8^{\circ}C$ was increased from when heat in greenhouse has not been used for heating and indoor surface temperature was increased by average $5.1^{\circ}C$. It shows it can be possible to use heat in greenhouse for heating, if the heating effects can be same as this experimental result because Energy Saving-Type buildings such as Low Energy House or Passive House keep from 18 to $20^{\circ}C$ in winter. Therefore, even if energy supply is cut off by disasters and other reasons, cooling and heating can be possible for some time.

An intelligent monitoring of greenhouse using wireless sensor networks

  • Touhami, Achouak;Benahmed, Khelifa;Parra, Lorena;Bounaama, Fateh;Lloret, Jaime
    • Smart Structures and Systems
    • /
    • 제26권1호
    • /
    • pp.117-134
    • /
    • 2020
  • Over recent years, the interest for vegetables and fruits in all seasons and places has much increased, from where diverse countries have directed to the commercial production in greenhouse. In this article, we propose an algorithm based on wireless sensor network technologies that monitor the microclimate inside a greenhouse and linear equations model for optimization plant production and material cost. Moreover, we also suggest a novel design of an intelligent greenhouse. We validate our algorithms with simulations on a benchmark based on experimental data made at lNRA of Montfavet in France. Finally, we calculate the statistical estimators RMSE, TSSE, MAPE, EF and R2. The results obtained are promising, which shows the efficiency of our proposed system.

PLC를 이용한 온실의 환경제어 (Control of Environments in Greenhouse Using Programmable Logic Controller)

  • 김동억;조한근;김형준
    • Journal of Biosystems Engineering
    • /
    • 제23권6호
    • /
    • pp.599-606
    • /
    • 1998
  • This study was carried out to develop the control system with PLC and its operating software and to investigate its control ability of greenhouse environments. Two experimental greenhouses were controlled by PLC and ON/OFF controller, respectively. In greenhouse controlled by PLC, target values of air temperature, relative humidity and $CO_2$ concentration were automatically changed. In warm-water heating, the variation of air temperature was reduced to $\pm$ $0.6^{\circ}C$ by the method of proportional-integration(PI) control with an inverter. In ventilation, the variation of air temperature was reduced, since windows open and close with multistage by mutual relation formula among the target, indoor, and outdoor temperature. Relative humidity at daytime was maintained with range of 35% to 55% by PLC controlled fogger. $CO_2$ concentration was automatically controlled from 300 to 800 $\mu$molㆍ$mol^{-1}$ according to amount of solar radiation. The suppling amount and frequency of nutrient solution were controlled by total integrated solar radiation. Difference in the yield of cucumber in the greenhouse controlled by PLC and by ON/OFF controller was not significant at the 5% level.

  • PDF

온실내 잉여에너지 이용을 위한 지중 열교환 시스템의 상추 재배 효과 (Effect of Air-earth Heat Exchange System on Growth of Leafy Lettuce in Greenhouse)

  • 백이;전종길;윤남규;강금춘;이시영
    • 한국기계기술학회지
    • /
    • 제13권4호
    • /
    • pp.71-76
    • /
    • 2011
  • Earth to air heat exchangers made by iron, aluminium, copper and poly-ethylene pipe for single greenhouse heating were experimented and blowers. Earth to air heat exchanger was installed by pipelines in earth tube at 70cm depths and air blower was the heating capacity 3kW/h, As the result, Temperature difference due to temperature history of the inlet and outlet air on the various type in earth tube in greenhouse showed that air temperature at the various type in earth tube, comparison tube were make no difference respectively. Under the experimental condition, heat fluxes and heating load were showed 6,800Kcal/h, 19,699kcal/h generally yield of Lactuca Sativa cultured during days of sowing 90day in greenhouse using copper pipe was 170% incleased.

태양에너지를 이용한 그린하우스 난방시스템의 열특성과 시뮬레이션 모델개발 (Thermal Energy Characteristics and Simulation Model Development for Greenhouse Heating System Using Solar Energy)

  • 노정근;송현갑
    • 한국태양에너지학회 논문집
    • /
    • 제21권2호
    • /
    • pp.27-34
    • /
    • 2001
  • The greenhouse heating system using solar energy has been realized in the protective agriculture in this study in order to analyse the thermal energy characteristics of the system the effects of ambient air temperature, solar radiation, relative humidities and water content of ambient air on the greenhouse air temperature were investigated through computer simulation experimental analysis for validation of the simulation. The results from this study are summarized as follows: 1) The expected values of inside air temperature for the system solar energy were very much close to the experimental values. 2) In the system using solar energy, the expected values of daytime surface temperature of soil by computer simulation were very much similar to the measured values, but those of nighttime were higher than the measured value by almost $2.5^{\circ}C$. 3) Heat loss of daytime was found to be larger than that of night time as much as 2.0 to 4.2 times for the system using solar energy. 4) In the system using solar energy. while the ambient air temperature varied between $-7^{\circ}C$ and $-3.8^{\circ}C$, the temperature of the inside air was maintained between $0^{\circ}C$ and $22^{\circ}C$. 5) At the minimum ambient temperature of $-7^{\circ}C$, the temperature of the inside air was $0^{\circ}C$.

  • PDF

아치형 단동온실의 최적설계를 위한 풍력계수분포도의 분석 (An Analysis of Wind Force Coefficient Distributions for Optimum Design of Single-Span Arched Greenhouse)

  • 이석건;이현우;권무남
    • 생물환경조절학회지
    • /
    • 제4권1호
    • /
    • pp.1-8
    • /
    • 1995
  • One of the most destructive forces around greenhouses is wind. Wind loads can be obtained by multiplying velocity pressure by dimensionless wind force coefficient. Generally, wind force coefficients can be determined by wind tunnel experiments. The wind force coefficient distribution on a single - span arched greenhouse was estimated using experimental data and compared with reported values from various countries. The results obtained are as follows : 1. The coefficients obtained from this study agree with the values proposed by G. L. Nelson except about 0.5 of difference in the middle region of roof section. This discrepancy is mainly attributed to the dissimilarity of experimental conditions (or wind tunnel test such as Reynolds number, type of terrain, surface roughness of model, location of the lapping and measuring methods. 2. Considering that the wind force coefficients are varied along the height of a wall at wind direction perpendicular to wall, structural analysis using subdivided wind force coefficient distribution is more resonable for wall. 3. It is recommendable that wind force coefficient distribution on a roof should take more subdivision than the existing four equal divisions for more accurate structural design. 4. Structural design using wind forces close to real values is more advantageous in safety and expense.

  • PDF

연동온실 곡부 제설장치의 설계인자 도출을 위한 실험적 연구 (An Experimental Study for Deriving Design Factors of Snow Removal Machines for Multi-span Greenhouse)

  • 송호성;김유용;윤남규;임성윤
    • 한국농공학회논문집
    • /
    • 제57권6호
    • /
    • pp.131-140
    • /
    • 2015
  • This paper presents overall procedure by experimental study in order to deriving design factors of snow removal machine on roof of multi-span greenhouse. For the purpose of the testing, the scale model of the machine was made in the form to drive above the monorail. The test was performed in order to calculating friction coefficient of the machine and shear coefficient between sliced horizontal section of snow at constant temperature and humidity room in National Academic of Agricultural Science. As a result of the laboratory test, shear coefficient between sliced horizontal section of snow were calculated 1.60~2.37. Further investigation, we will study to derive the relationship between the real and scaled model through the field test.

자연환기 온실의 환기회수에 따른 포그냉방시스템의 냉방효과 (The Cooling Effect of Fog Cooling System as Affected by Air Exchange Rate in Natural Ventilation Greenhouse)

  • 김문기;김기성;권혁진
    • 생물환경조절학회지
    • /
    • 제10권1호
    • /
    • pp.10-14
    • /
    • 2001
  • 포그냉방시스템의 냉방효과는 온실 내부의 상대습도, 공기유동과 밀접한 관계가 있다. 냉방설계용 VETH선도에서 냉발효율은 환기회수의 증가와 그에 상응하는 분무수량의 증가로 인하여 개선될 수 있다. 시간제어방식을 이용한 무차광 실험온실에서 분당 환기회수가 평균 0.77회, 분무수량이 2,009g 일 때 온실 내부의 기온이 31$^{\circ}C$로 외부기온과 거의 같게 나타났으며, 이 때의 증발효율은 82%이다. 분당 환기회수가 평균 0.26회, 분무수량이 1.256g인 경우 무냉방 온실의 기온과 비슷한 37.1$^{\circ}C$였다. 차광율 70%인 실험온실의 분당 환기환수가 평균 2.59회, 분무수량이 2,009g 일 때, 내부의 상대습도는 증가하나 기온은 하강하지 못했다. 그러나 분당 환기회수가 평균 2.33회, 분무수량이 2,009g인 경우 내부의 기온이 31.4$^{\circ}C$로 이 때 온실의 유입구 풍속은 최고 1.9m.s$^{-1}$였다. 시간제어의 경우 일정간격으로 일정한 수량을 분무하기 때문에 분무입자가 모두 증발하지 못하고 온실 내부에 누적되어 온실 내부의 상대습도를 증가시켜 냉방효율을 감소 시키는 원인이 되고 차광망이 온실내부의 공기흐름을 차단하여 증발효율을 감소시키는 것으로 나타났다. 포그냉방시스템의 냉방효율을 높이기 위해서는 온실 내부의 상대습도에 의한 제어방식과 내부 공기의 순환에 대한 연구가 필요하다.

  • PDF