• 제목/요약/키워드: existing reinforced concrete buildings

검색결과 171건 처리시간 0.032초

Modifier parameters and quantifications for seismic vulnerability assessment of reinforced concrete buildings

  • Oumedour, Amira;Lazzali, Farah
    • Earthquakes and Structures
    • /
    • 제22권1호
    • /
    • pp.83-94
    • /
    • 2022
  • In recent years, some studies have identified and quantified factors that can increase or decrease the seismic vulnerability of buildings. These modifier factors, related to the building characteristics and condition, are taken into account in the vulnerability assessment, by means of a numerical estimation resulting from the quantification of these modifiers through vulnerability indexes. However, views have differed on the definition and the quantification of modifiers. In this study, modifier parameters and scores of the Risk-UE Level 1 method are adjusted based on the Algerian seismic code recommendations and the reviews proposed in the literature. The adjusted modifiers and scores are applied to reinforced concrete (RC) buildings in Boumerdes city, in order to assess probable seismic damage. Comparison between estimated damage and observed damage caused by the 2003 Boumerdes earthquake is done, with the objective to (i) validate the model involving influence of the modifier parameters on the seismic vulnerability, and (ii) to define the relationship between modifiers and damage. This research may help planners in improving seismic regulations and reducing vulnerability of existing buildings.

FRP자켓 시스템이 보강된 비내진 철근콘크리트 골조의 실물 크기 강제 진동 실험 (Forced Vibration Testing of Full-scale Non-seismic Reinforced Concrete Frame Structure Retrofitted Using FRP Jacketing System)

  • 신지욱
    • 한국지진공학회논문집
    • /
    • 제22권5호
    • /
    • pp.281-289
    • /
    • 2018
  • Existing reinforced concrete building structures have seismic vulnerabilities due to their seismically-deficient details resulting in non-ductile behavior. The seismic vulnerabilities can be mitigated by retrofitting the buildings using a fiber-reinforced polymer column jacketing system, which can provide additional confining pressures to existing columns to improve their lateral resisting capacities. This study presents dynamic responses of a full-scale non-ductile reinforced concrete frame retrofitted using a fiber-reinforced polymer column jacketing system. A series of forced-vibration testing was performed to measure the dynamic responses (e.g. natural frequencies, story drifts and column/beam rotations). Additionally, the dynamic responses of the retrofitted frame were compared to those of the non-retrofitted frame to investigate effectiveness of the retrofit system. The experimental results demonstrate that the retrofit system installed on the first story columns contributed to reducing story drifts and column rotations. Additionally, the retrofit scheme helped mitigate damage concentration on the first story columns as compared to the non-retrofitted frame.

Seismic risk investigation for reinforced concrete buildings in Antalya, Turkey

  • Kepenek, Engin;Korkmaz, Kasim A.;Gencel, Ziya
    • Computers and Concrete
    • /
    • 제26권3호
    • /
    • pp.203-211
    • /
    • 2020
  • Turkey is located in one of the most seismically active regions of in Europe. The majority of the population living in big cities are at high seismic risk due to insufficient structural resistance of the existing buildings. Such a seismic risk brings the need for a comprehensive seismic evaluation based on the risk analysis in Turkey. Determining the seismic resistance level of existing building stock against the earthquakes is the first step to reduce the damages in a possible earthquake. Recently in January 2020, the Elazig earthquake brought the importance of the issue again in the public. However, the excessive amount of building stock, labor, and resource problems made the implementation phase almost impossible and revealed the necessity to carry out alternative studies on this issue. This study aims for a detailed investigation of residential buildings in Antalya, Turkey. The approach proposed here can be considered an improved state of building survey methods previously identified in Turkey's Design Code. Antalya, Turkey's fifth most populous city, with a population over 2.5 Million, was investigated as divided into sub-regions to understand the vulnerability, and a threshold value found for the study area. In this study, 26,610 reinforced concrete buildings between 1 to 7 stories in Antalya were examined by using the rapid visual assessment method. A specific threshold value for the city of Antalya was determined with the second level examination and statistical methods carried out in the determined sub-region. With the micro zonation process, regions below the threshold value are defined as the priority areas that need to be examined in detail. The developed methodology can be easily calibrated for application in other cities and can be used to determine new threshold values for those cities.

Seismic retrofit of a steel-reinforced concrete hospital building using continuous energy-dissipative steel columns

  • Massimiliano Ferraioli;Biagio Laurenza;Angelo Lavino;Ciro Frattolillo;Gianfranco De Matteis
    • Steel and Composite Structures
    • /
    • 제47권4호
    • /
    • pp.467-488
    • /
    • 2023
  • Seismic retrofit of an existing steel-reinforced concrete hospital building that features innovative use of a continuous energy-dissipative steel column (CEDC) system is presented in this paper. The special system has been adopted to provide an efficient solution taking into account the difficulties of applying traditional intervention techniques to minimize the impact on architectural functionality and avoid the loss of building function and evacuation during the retrofit implementation. The lateral stiffness and strength of the CEDC system were defined based on the geometric and mechanical properties of the steel strip dampers. The hysteretic behavior under cyclic loadings was defined using a simplified numerical model. Its effectiveness was validated by comparing the results of full-scale experimental data available from the literature. All the main design considerations of the retrofitting plan are described in detail. The effectiveness of the proposed retrofitting system was demonstrated by nonlinear time-history analyses under different sets of earthquake-strong ground motions. The analysis results show that the CEDC system is effective in controlling the deformation pattern and significantly reducing damage to the existing structure during major earthquakes.

격자형 유닛 상세를 가진 단면증설공법으로 보강된 철근콘크리트 기둥의 구조성능평가 (An Evaluation of Structural Performance of Reinforced Concrete Column Retrofitted with Grid Type Unit Details of Jacketing Method)

  • 문홍비;이정인;이영학
    • 한국공간구조학회논문집
    • /
    • 제22권1호
    • /
    • pp.41-49
    • /
    • 2022
  • In the case of columns in buildings with soft story, the concentration of stress due to the difference in stiffness can damage the columns. The irregularity of buildings including soft story requires retrofit because combined load of compression, bending, shear, and torsion acts on the structure. Concrete jacketing is advantageous in securing the strength and stiffness of existing members. However, the brittleness of concrete make it difficult to secure ductility to resist the large deformation, and the complicated construction process for integrity between the existing member and extended section reduces the constructability. In this study, two types of Steel Grid Reinforcement (SGR), which are Steel Wire Mesh (SWM) for integrity and Steel Fiber Non-Shrinkage Mortar (SFNM) for crack resistance are proposed. One reinforced concrete (RC) column with non-seismic details and two columns retrofitted with each different types of proposed method were manufactured. Seismic performance was analyzed for cyclic loading test in which a combined load of compression, bending, shear, and torsion was applied. As a result of the experiment, specimens retrofitted with proposed concrete jacketing method showed 862% of maximum load, 188% of maximum displacement and 1,324% of stiffness compared to non-retrofitted specimen.

비선형 동적해석을 이용한 소규모 필로티형 철근콘크리트 건축물의 내진성능평가 (Seismic Performance Evaluation of Small-size Pilloti-type Reinforced Concrete Buildings using Nonlinear Dynamic Analysis)

  • 유창환;김태완;추유림
    • 한국지진공학회논문집
    • /
    • 제20권4호
    • /
    • pp.191-199
    • /
    • 2016
  • Piloti-type building is one of typical vertical atypical buildings. These buildings can fail by weak-story or flexible-story mechanism on the first story. They should be designed by taking into account the special seismic load, but those less than six stories are not required to confirm the seismic performance from structural engineers in Korea. For this reason, small-size pilloti-type RC buildings need to be checked for seismic performance. Based on this background, this study performed nonlinear dynamic analysis using the PERFORM-3D for small-size pilloti-type RC buildings and assessed their seismic performance. Examples are two through four story buildings with and without walls in the first story. The walls and columns in the first story satisfied the target performance in the basic of flexural behavior due to quite a large size and reinforcement. However, wall shear demands exceed shear strength in some buildings. When designed for KBC2009, wall shear strength exceed shear demand in some buildings, but still does not in others. Consequently, wall shear must be carefully checked in both existing and new small-size pilloti-type RC buildings.

설계스펙트럼의 개정에 따른 철근콘크리트 보통모멘트골조의 내진성능수준 평가 (Performance-Based Evaluation of Seismic Design Proposals for RC Ordinary Moment Frames by Spectrum Revision)

  • 심정은;최인섭;김준희
    • 한국지진공학회논문집
    • /
    • 제26권5호
    • /
    • pp.211-217
    • /
    • 2022
  • New buildings have been designed using different seismic design standards that have been revised. However, the seismic performance of existing buildings is evaluated through the same performance evaluation guidelines. Existing buildings may not satisfy the performance targets suggested in the current guidelines, but there are practical limitations to discriminating the existing buildings with poor seismic performance through a full investigation. In this regard, to classify buildings with poor seismic performance according to the applied standard, this study aimed to evaluate performance-based investigation of the seismic design proposals of buildings with different design standards. The target buildings were set as RC ordinary moment frames for office occupancy. Changes in seismic design criteria by period were analyzed, and the design spectrum changes of reinforced concrete ordinary moment resisting frames were compared to analyze the seismic load acting on the building during design. The seismic design plan was derived through structural analysis of the target model, compared the member force and cross-sectional performance, and a preliminary evaluation of the seismic performance was performed to analyze the performance level through DCR. As a result of the seismic performance analysis through the derived design, the reinforced concrete ordinary moment frame design based on AIK 2000 has an insufficient seismic performance level, so buildings built before 2005 are likely to need seismic reinforcement.

The investigation of seismic performance of existing RC buildings with and without infill walls

  • Dilmac, Hakan;Ulutas, Hakan;Tekeli, Hamide;Demir, Fuat
    • Computers and Concrete
    • /
    • 제22권5호
    • /
    • pp.439-447
    • /
    • 2018
  • One of the important factors is the infill walls in the change of the structural rigidity, ductility, dynamic and static characteristics of the structures. The infill walls are not generally included in numerical analysis of reinforced concrete (RC) structural system due to lack of suitable theory and the difficulty of calculating the recommended models. In seismic regions worldwide, the residential structures are generally RC buildings with infill wall. Therefore, understanding the contribution of the infill walls to seismic performance of buildings may have a vital importance. This paper investigates the effects of infill walls on seismic performance of the existing RC residential buildings by considering requirements of the Turkish Earthquake Code (TEC). Seismic performance levels of residential RC buildings with and without walls in high-hazard zones were determined according to the nonlinear procedure given in the code. Pushover curves were obtained by considering the effect of masonry infill walls on seismic performance of RC buildings. The analysis results showed that the infill walls beneficially effected to the rigidity, roof displacements and seismic performance of the building.

중·저층 철근콘크리트 건물의 SRCF 외부접합 내진보강공법의 내진성능 평가 (Seismic Performance Evaluation of Seismic Strengthening Method using SRCF External Connection of Medium and Low-rise R/C Buildings)

  • 이강석;정주성;이종권
    • 콘크리트학회논문집
    • /
    • 제27권2호
    • /
    • pp.147-155
    • /
    • 2015
  • 본 연구에서는 기존 강도증진형 내진보강법의 단점을 보완 개선할 수 있는 새로운 개념의 내진보강법인 SRCF (Steel Reinforced Concrete Frame) 외부접합형 내진보강법을 제안하였다. SRCF 보강법은 거주자가 거주가 가능하면서 내진보강 공사를 실시할 수가 있으며, 접합부 시공성이 탁월하며, 특히 필요 내진보강량 산정이 간편한 전형적인 강도증진형으로 전단파괴가 지배적인 비내진상세를 가지는 국내 중 저층 철근콘크리트 건물에는 내력확보가 용이한 내진보강공법이다. 본 연구에서 제안한 SRCF 외부접합형 공법의 유용성을 검증 할 목적으로 기존 중 저층 철근콘크리트 학교건물의 골조를 대상으로 유사동적실험을 실시하여 내진보강효과를 검토하였다. 그 결과, 국내에서 발생 가능한 최대 지진규모(300gal)에서 비보강 골조는 붕괴를 하였지만, SRCF 외부접합형 내진보강법으로 보강한 골조는 경미한 지진피해가 예상되었으며, 대규모 지진(400, 500gal)을 상정한 경우에도 소규모 이하의 지진피해가 예상되어 본 연구에서 개발한 SRCF 내진보강법의 유효성이 검증되었다고 사료된다.

고강도 표면매립용철근과 탄소섬유시트로 보강된 비연성 철근콘크리트 골조의 실물 진동기 실험 (Full-Scale Shaker Testing of Non-Ductile RC Frame Structure Retrofitted Using High-Strength Near Surface Mounted Rebars and Carbon FRP Sheets)

  • 신지욱;전종수
    • 한국지진공학회논문집
    • /
    • 제23권1호
    • /
    • pp.43-54
    • /
    • 2019
  • Existing reinforced concrete frame buildings designed for only gravity loads have been seismically vulnerable due to their inadequate column detailing. The seismic vulnerabilities can be mitigated by the application of a column retrofit technique, which combines high-strength near surface mounted bars with a fiber reinforced polymer wrapping system. This study presents the full-scale shaker testing of a non-ductile frame structure retrofitted using the combined retrofit system. The full-scale dynamic testing was performed to measure realistic dynamic responses and to investigate the effectiveness of the retrofit system through the comparison of the measured responses between as-built and retrofitted test frames. Experimental results demonstrated that the retrofit system reduced the dynamic responses without any significant damage on the columns because it improved flexural, shear and lap-splice resisting capacities. In addition, the retrofit system contributed to changing a damage mechanism from a soft-story mechanism (column-sidesway mechanism) to a mixed-damage mechanism, which was commonly found in reinforced concrete buildings with strong-column weak-beam system.