• Title/Summary/Keyword: existing building

Search Result 3,038, Processing Time 0.032 seconds

The study of in-situ measurement method for wall thermal performance diagnosis of existing apartment (기존 공동 주택의 벽체 열성능 현장 측정법에 관한 연구)

  • Kim, Seohoon;Kim, Jonghun;Yoo, Seunghwan;Jeong, Hakgeun;Song, Kyoodong
    • KIEAE Journal
    • /
    • v.16 no.4
    • /
    • pp.71-77
    • /
    • 2016
  • Purpose : The energy saving in a residential building (apartment) sector is known as one of the effective solution of energy reduction. In South Korea, the government has recently reinforced regulations associated with the energy performance of buildings. However, there is a lack of research on the methods for the energy performance diagnosis that is used to analyze the wall thermal performance of the existing apartments. Because a reliable diagnosis is necessary to save the building energy, this study analyzed wall thermal performance of an existing apartment in Seoul. Method : This paper applied two methods for analysis of the thermal insulation performance; HFM(Heat Flow Meter) method and ASTR(Air-Surface Temperature Ratio) method. The HFM method is suggested by ISO9869-1 code to measure the thermal performance. The ASTR method is proposed by this study for the simplified In-situ measurement and it uses three temperature data (interior wall surface, interior and exterior air) and the overall heat transfer coefficient. This study conducted the experiment of an existing apartment in Seoul using these methods and analyzed the results. Furthermore, the energy simulation tool of the building was used to suggest retrofit of the building based on the results of measurements. Result : The error rate of HFM method and ASTR method was analyzed in about 17 to 20%. As the results of comparison between the initial design values of the wall and the measured values, the 26% degradation of insulation thermal performance was measured. Lastly, the energy simulation tool of the building shows 10.8% energy savings in accordance with the construction of suggested retrofit.

Determination of Shear Wave Velocity Profile under Existing Building for Site Response Analysis Using HWAW Method (HWAW방법을 이용한 기존 건물 내진 보강을 위한 건물 하부지반 전단파 속도 주상도 결정)

  • Park, Hyung-Choon;Hwang, Hea-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.5
    • /
    • pp.15-23
    • /
    • 2017
  • The evaluation of earthquake load on the surface is very important factor for the seismic reinforcement of existing building, and the magnitude of earthquake load depends on a shear wave velocity profile of soil under a building. To determine a shear wave velocity profile under a existing building, test method should be able to determine a reliable shear wave velocity profile under conditions such as heavy background noise and the small test area, and be sensitive to the variation of material property. In this research, HWAW (Harmonic Wavelet Analysis of Waves) method is applied to determine a shear wave velocity profile under a existing building. In this paper, through numerical simulations and field tests, the feasibility of the proposed method was shown.

An Evaluation of Seismic Performance for Existing School Building Using Capacity Spectrum Method (성능스펙트럼법을 이용한 기존 학교 건축물의 내진성능평가 및 보강효과 검증)

  • Jang, Jeong-Hyun;Hwang, Ji-Hoon;Yang, Kyeong-Seok;Takashi, Kamiya;Choi, Jae-Hyouk
    • Journal of Advanced Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.11-18
    • /
    • 2012
  • Large scale earthquake was occurred in different parts of the world like Japan (in 1995), Republic of Pakistan (2005), in China (2008) etc and enormous structures were damaged. As a result of collapse of school buildings structures numerous students are died and it had a big impact on the international community. Therefore, the interest of preparing the seismic resistant school building structures in our country is increases as school building are used as emergency shelter for local residents. But the current standard of seismic design ratio of 3.7% is applied for school building in Korea which is only significant earthquake damage is expected. In order to overcome the current situation, seismic performance evaluation is carried out for the existing school building and an accurate and appropriate seismic retrofit is required based on performance evaluation to upgrade the existing school buildings. In this paper, nonlinear analysis on existing school buildings for ATC-40(Applied Technology Council, ATC) and FEMA-356(Federal Emergency Management Agency, FEMA) are carried out using the capacity spectrum method to evaluate seismic performance and to determine the need for retrofitting. In addition, after reinforcement to enhance the seismic performance is applied the seismic performance evaluation is carried out to verify the effectiveness of seismic retrofit.

Energy Saving Effects of Green Roof in Exiting Buildings according to Different Insulation Levels (기존 노후 건물의 단열 성능에 따른 옥상 녹화 시스템 설치시 에너지 성능 변화)

  • An, Kyeong A;Han, Seung Won;Moon, Hyeun Jun
    • Journal of Korean Living Environment System
    • /
    • v.21 no.6
    • /
    • pp.959-964
    • /
    • 2014
  • Energy performance of building envelope components, including external walls, floors, roofs, windows and doors, is crutial for determining how much energy is required for heating and cooling in a building. Among various building technologies, a green roof system can be a good option for reducing heat gain and loss in new buildings as well as existing buildings for green remodeling. This paper evaluates the performance of green roof systems according to soil depth and Leaf Area Index (LAI) for existing buildings. It also attempts to quantify the energy saving effects on new and existing buildings with different insulation levels. Thermal performance of green roofs is mainly dependent on soil thickness and LAI. Installation of green roofs in deteriorated existing buildings can lead to improvements in roof insulation, due to the soil layer. An increase in soil depth leads to a decrease in heating load, regardless of conditions of vegetation on the green roof. Larger LAI values may reduce cooling loads in the cooling season. Installation of green roof in deteriorated existing buildings showed bigger energy saving effect in comparison to a case in new buildings. A simulation study showed that the installation of green roof systems in deteriorated existing buildings with low insulation levels, due to low thermal performance requirements when constructed, could improve the energy performance of the buildings similar or better to the peformance on new buildings with the most updated insulation standard. Thus, when remodeling a deteriorated building, green roofs could be a good option to meet the most recent energy requirements.

A Study on Process for District Office Building Maintenance with EPIQR+ (on Focusing Energy and Economics Evaluation) (EPIQR+를 이용한 구청사 건물에 대한 경제적, 에너지관점에서의 건물 재평가)

  • Kim, Tae Han
    • KIEAE Journal
    • /
    • v.9 no.5
    • /
    • pp.13-20
    • /
    • 2009
  • This study suggested practical application of decision aid tool on re-evaluation of current buildings with a focus on a energy and economics evaluation methodology. In Europe, over forty percent of all construction activities are for retrofit. For efficient construction, various tools for re-evaluating existing buildings have been developed and are in use. Legislations of relevant laws and studies are actively initiated. In particular, EPIQR (Energy Performance Indoor environment Quality Retrofit), which was developed through the EU's Third and Fourth Framework Programs laid a foundation on a new concept-based decision aid tool for re-evaluation of existing buildings. As for actual applications, based on this, EPIQR+ was developed to be in line with a building maintenance guideline (SIA 469) and is actively applied to public buildings. This tool quantifies the degree of damages of existing buildings and suggests alternatives to users in energy (SIA 380/1) and economical perspectives. This study examined these preceding tools and suggested some trenchant approaching for more comprehensive and efficient use of re-evaluation tools in building maintenance.

The development and application of environmental impact assessment program for apartment building element based on building materials LCI DB (건축재료 LCI DB 기반의 공동주택 부위별 환경영향 평가 프로그램 개발 및 적용에 관한 연구)

  • Kim, Rak Hyun;Tae, Sung Ho;Kim, Ji Hoon;Lee, Jong Gun
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.151-157
    • /
    • 2016
  • Purpose: The purpose of this study is to develop and apply an environmental impact assessment program for apartment building elements, based on the building materials of the LCI DB, which can link the LCA results of building materials and buildings. Method: For this purpose, a framework for building elements was established, and several building material combinations were developed. In addition, the LCA method for quantifying environmental load emissions from the building materials of each site was applied to establish an environmental impact database of the building materials of the LCI DB. Result: An environmental impact assessment program, based on a Microsoft Excel worksheet, was developed for apartment building elements. This program can link the environmental impact assessment of building materials and building units. To validate the program evaluation results that were obtained in this study, a comparative analysis was carried out using the results of existing evaluation methods. The error rate was estimated to be 5% for environmental impact assessment using existing evaluation methods.

A Classification Methodology of Structural Types of RC Buildings for Improving Seismic Fragility Functions (지진취약도 함수 개선을 위한 철근콘크리트 건물의 구조 유형 분류 방안)

  • Kim, Taewan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.6
    • /
    • pp.285-292
    • /
    • 2020
  • The methodology classifying structural types of concrete buildings in the existing seismic fragility functions is too simple to estimate the fragility of existing residential buildings and neighborhood living facilities, especially those below five stories. Their structural types are dependent on information contained in the building register such as main use, total floor area, story, permission date, and first story floor area of the individual building. All of this information is not considered for classifying types in the existing functions; therefore, the goal of this study was to suggest a methodology that classifies structural types of concrete buildings by utilizing such information. The results of this study showed that the suggested methodology can classify structural types better than the existing methodology. Nevertheless, there is still a need to simplify the methodology because fragility estimation demands quickness rather than accuracy.

Seismic assessment of a R/C strategic existing building

  • Mehani, Youcef;Kibboua, Abderrahmane
    • Structural Engineering and Mechanics
    • /
    • v.26 no.6
    • /
    • pp.617-634
    • /
    • 2007
  • Algeria is a country with a high seismic activity. During the last decade, many destructive earthquakes occurred, particularly in the northern part, causing enormous losses in human lives, buildings and equipments. In order to reduce this risk in the capital and avoid serious damages to the strategic existing buildings, the government decided to invest into seismic upgrade, strengthening and retrofitting of these buildings. In doing so, seismic vulnerability study of this category of buildings has been considered. Structural analysis is performed on the basis of site investigation (inspection of the building, collecting data, materials, general conditions of the building, etc), and existing drawings (architectural plans, structural design, etc). The aim of these seismic vulnerability studies is to develop guidelines and a methodology for rehabilitation of existing buildings. This paper will provide insight to the vulnerability assessment and strengthening of the telecommunication centre, according to the new code RPA 99/version 2003. Both, static equivalent method and non linear dynamic analysis are performed in this study.

A Study on Remodeling Method of Library Architecture (도서관건축의 리모델링 수법)

  • Lee, Ji-Young
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.24 no.1
    • /
    • pp.3-10
    • /
    • 2017
  • This study is to analyze the remodeling method of library in terms of space extension method and urban regeneration by repurposing function in unused facilities through case study. In many case of library extension, horizontal extensions are more frequent than vertical extensions, because there are limits to extend vertically due to high live load estimation by book stacks. Extension schemes was organized by new building extension method in connection with existing buildings, attaching method small scaled mass or linear mass to existing building, connecting method a plurality of existing small buildings, vertical extension method on the top of the structure, underground extension method using special structure. Unused facility remodeling to the library, large scaled buildings can be developed completely to the function of the library through the relocation of the space, while small scaled building needs spatial extension. In the case of spatial extension, existing space that was used for other purposes can be used as a reading room or office, avoiding high live load estimation.

Measurement and Simulation of Interior Luminous Environment for the Decision Process of Building Remodeling (건물 개보수의 의사결정과정에서 필요한 실내의 빛환경 측정 및 시뮬레이션 -사례중심으로-)

  • 최안섭;성민기
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.5
    • /
    • pp.8-13
    • /
    • 2001
  • The make a decision for building remodeling, the economical value of the remodeled building should be analyzed and existing situation of the building system should be checked. For the energy issues related to the building remodeling process, careful diagnosis and re-designs of existing system should be proposed. In this research, the luminous environment for Seoul K Co. headquaters and Seoul S hotel were measured and then the re-design processes of building illumination systems were researched. With measured illuminance quantities of there cases, computer simulations for the existing situation and re-design were conducted.

  • PDF