• Title/Summary/Keyword: exchange length

Search Result 232, Processing Time 0.023 seconds

A Study on Burial Guideline of Horizontal Geothermal Heat Exchanger based on Exit Temperature (출구 온도를 고려한 수평형 지중열교환기의 매설 지침에 관한 연구)

  • Cho, Sung-Woo;Ihm, Pyeong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.553-558
    • /
    • 2014
  • Geothermal energy can be used with a geothermal heat pump or an earth-to-air heat exchange system (EAHES), which is referred to as a "cooling tube" in Korea. In this study, we suggest EAHES burial guidelines in terms of the parameters of buried pipe length and air velocity regarding the exit air temperature of EAHES. The exit air temperature for EAHES in three regions (Changwon, Busan and Seoul) was calculated with variation in buried pipe length and air velocity at ${\Phi}100mm$ and ${\Phi}200mm$. In conclusion, variation in the buried pipe length is more effective than that of air velocity to achieve the required exit air temperature.

Iterative Symbol Decoding of Variable-Length Codes with Convolutional Codes

  • Wu, Hung-Tsai;Wu, Chun-Feng;Chang, Wen-Whei
    • Journal of Communications and Networks
    • /
    • v.18 no.1
    • /
    • pp.40-49
    • /
    • 2016
  • In this paper, we present a symbol-level iterative source-channel decoding (ISCD) algorithm for reliable transmission of variable-length codes (VLCs). Firstly, an improved source a posteriori probability (APP) decoding approach is proposed for packetized variable-length encoded Markov sources. Also proposed is a recursive implementation based on a three-dimensional joint trellis for symbol decoding of binary convolutional codes. APP channel decoding on this joint trellis is realized by modification of the Bahl-Cocke-Jelinek-Raviv algorithm and adaptation to the non-stationary VLC trellis. Simulation results indicate that the proposed ISCD scheme allows to exchange between its constituent decoders the symbol-level extrinsic information and achieves high robustness against channel noises.

Theorizing Length of Relationship as Moderator of Key Account Management Performance- Repeat Order Link

  • Ahmmed, Kawsar;Mohd, Nor Azila
    • The Journal of Economics, Marketing and Management
    • /
    • v.2 no.1
    • /
    • pp.1-17
    • /
    • 2014
  • In today's highly competitive and fast changing business environment, key account management-a supplier company initiated relationship marketing approach targeted at the most important customers to solve their complex requirements with special treatment that eventually ensures both parties' financial and nonfinancial objectives- has regarded as a strategic weapon of many companies' sales efforts to manage their strategically important customers. On the basis of the existing studies, this research introduces a theoretical model highlighting the hypothetical relationship between key account management performance and repeat order. In addition, moderating effect of length of relationship on the relationship between key account management performance and repeat order is also introduced. We theorize the conditions under which key account management performance influences key customer repeat order behavior as well as the influence of moderating variable of length of relationship on key account management performance-repeat order relationship. Theoretical and managerial implications are provided along with suggestions to isolate a platform for future empirical research.

Synthesis of Lithium Titanate Whisker Using Ion-Exchange of Acid Treatment

  • Um Myeong-Heon;Lee Jin-Sik
    • Korean Journal of Materials Research
    • /
    • v.14 no.9
    • /
    • pp.627-633
    • /
    • 2004
  • Lithium titanate whiske($Li_{x}Ti_{4}O_9$) was prepared by an ion-exchange reaction. To this end, the initial material, potassium tetratitanate ($K_{2}Ti_{4}O_9{\cdot}nH_{2}O$) was prepared by calcination of a mixture of $K_{2}CO_3\;and\;TiO_2$ with a molar ratio of 2.8 at $1050^{\circ}C$ for 3 h, followed by boiling water treatment of the calcined products for 10 h. Fibrous potassium tetratitanate could be transformed into layered hydrous titanium dioxide ($H_{2}Ti_{4}O_9{\cdot}nH_{2}O$) through an exchange of $K^{+}\;with\;H^{+}$ using 0.075 M HCl. Also, lithium titanate whisker was finally prepared as $Li^{+}\;and\;H^{+}$ ions were exchanged by adding 20 mL of a mixture solution of LiOH and $LiNO_3$ to 1g whisker and stirring for $5\~15$ days. The average length and diameter of the $Li_{x}Ti_{4}O_9$ whiskers were $10\~20{\mu}m\;and\;1\~3{\mu}m$, respectively.

Effects of Pitch Length of Stack-type EGR Cooler on Heat Exchange Characteristics in a Diesel Engine (적층형 EGR Cooler의 Pitch 길이 변화가 열교환 특성에 미치는 영향)

  • Hwang, Se-Joon;Kim, Min-Chol;Jang, Sang-Hoon;Kim, Hyung-Man
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.2
    • /
    • pp.135-140
    • /
    • 2010
  • An important goal in diesel engine research is the development of a means to reduce the emissions of nitrogen oxides (NOX). The use of a cooled exhaust gas recirculation (EGR) system is one of the most effective techniques currently available for reducing nitrogen oxides. Since Particular Matter (PM) fouling reduces the efficiency of an EGR cooler, a trade-off exists between the amount of NOX and PM emissions, especially at high engine loads. In the present study, engine dynamometer experiments have been performed to investigate the heat exchange characteristics of the stack-type EGR coolers with wave fin pitches of 3.6 and 4.6 mm. The results show that the heat exchange effectiveness is decreased as surface area decrease with pitch of 4.6 mm due to PM fouling. As surface area increase at pitch of 3.6 mm, super-cooling happens in the recirculated exhaust gas.

Estimation of Heat Exchange Rate of Standing Column Well for Sustainable Groundwater Curtain for Greenhouse Heating (순환식 지하수 수막시스템 그린하우스 난방을 위한 스탠딩컬럼웰 열교환율 산정)

  • Byoung Ohan Shim;Seung Gyun Baek;Seonghoon Jeong
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.20 no.2
    • /
    • pp.11-23
    • /
    • 2024
  • In order to design a standing column well (SCW) for a sustainable groundwater curtain system for greenhouse heating, we conducted parameter sensitivity tests. These tests simulated the outlet temperature changes of the SCW in a groundwater recirculating greenhouse cultivation system. Our modeling considered ground thermal conductivity and hydrogeological conditions. Specifically, we examined several factors, including SCW length, enhanced thermal conductivity of the ground, and groundwater circulation rate. The simulation results indicated that there was not a significant difference in the heat exchange rate based on the characteristics of enhanced thermal conductivity. However, we anticipate a substantial difference in the case of varying SCW lengths. Therefore, we conclude that the simulation results are primarily influenced by conductive heat exchange values, as the circulating water remains at a constant groundwater level.

Evaluation of Heat Exchange Rate in Horizontal Slinky and Coil Type Ground Heat Exchangers Considering Pitch Interval (피치 간격에 따른 수평 슬링키형과 코일형 지중 열교환기의 열효율 평가)

  • Yoon, Seok;Lee, Seung-Rae;Kim, Min-Jun;Kim, Woo-Jin;Go, Gyu-Hyun;Jeon, Jun-Seo
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.7
    • /
    • pp.55-61
    • /
    • 2014
  • The need of geothermal energy is constantly increasing for economical and environmental utilization. Horizontal ground heat exchangers (GHEs) can reduce installation cost and increase efficiency. There are many kinds of GHEs, and it is known that slinky and spiral coil type GHEs show high thermal performance. Therefore, this paper presents experimental results of heat exchange rates in horizontal slinky and spiral coil type GHEs installed in a steel box whose size is $5m{\times}1m{\times}1m$. Dried Joomunjin standard sand was filled in a steel box, and thermal response tests (TRTs) were conducted for 30 hours to evaluate heat exchange rates by changing different pitch spaces of horizontal slinky and spiral coil type GHEs. As a result, spiral coil type GHE showed 30~40% higher heat exchange rates per pipe length than horizontal slinky type GHEs. Furthermore, long pitch interval (Pitch/Diameter=1) showed 200~250% higher heat exchange rates per pipe length than short pitch interval (Pitch/Diameter=0.2) in both spiral coil and horizontal slinky type GHEs, respectively.

The Synthesis of Sodium Titanate by the Ion Exchange of H+/Na+ from Hydrous Titanium Dioxide and its Phase Transition (Hydrous Titanium Dioxide로부터 H+/Na+의 이온교환에 의한 티탄산나트륨의 합성 및 성전이)

  • Lee, Jin-Sik;Song, Yon-Ho;Lee, Chul-Tae
    • Applied Chemistry for Engineering
    • /
    • v.9 no.4
    • /
    • pp.585-590
    • /
    • 1998
  • Fibrous $Na_xTi_nO_{2n+1}$ whisker was prepared by $H^+/Na^+$ ion-exchange on layered hydrous titanium dioxide ($H_2Ti_4O_9{\cdot}nH_2O$). The ion-exchange reaction was proceeded at 0.5~2.0 M NaOH solution. In the ion-exchange at 2.0 M NaOH solution, 73% of sodium was exchanged and the prepared $Na_xTi_nO_{2n+1}$ whisker was a fibrous crystal of about $10{\sim}20{\mu}m$ of length and about $0.7{\mu}m$ of diameter. The phase transition of the ion-exchange phases identified by the thermal analysis. The result showed that the $Na_xTi_nO_{2n+1}$ whisker was decomposed into $Na_2Ti_6O_{13}$ and $TiO_2$ in the temperature of $200{\sim}600^{\circ}C$.

  • PDF

Study on the Recovery and Determination of Scandium from Tin Slag (주석슬러그에서 스칸듐원소의 정량 및 회수에 관한 연구)

  • Cha, Gi Won;Jeong, Ui Sik;Kim, Gyeong Hwan
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.1
    • /
    • pp.98-101
    • /
    • 1990
  • A new spectrophotometric determination method of scandium in the tin slag solution has been investigated using methyl thymol blue as a colorimetric reagent. Scandium is recovered by the anion exchange resin, Amberlite IRA 400, using the mixture solution of ammonium sulfate and sulfuric acid and an eluent. The mole ratio of complex of scandium and MTB at pH 6 is 1 to 1 and the wave length of the maximum absorbance is 585 nm and the molar absorptivity at this wave length is $2.0 {\times} 10^4\;\iota{\cdot}mol^{-1}{\cdot}cm^{-1}$. When tin slag solution is loaded into anion exchange resin and eluted, ions in the solution except scandium ion are eluted rapidly and scandium is eluted lately. So scandium is recovered easily.

  • PDF

Reactive Dispersion and Mechanical Property of Dicyanate/Montmorillonite Nanocomposite (반응이 수반된 Dicyanate/Montmorillonite Nanocomposite의 분산과 물성특성 연구)

  • 장원영;이근제;남재도
    • Polymer(Korea)
    • /
    • v.27 no.1
    • /
    • pp.75-83
    • /
    • 2003
  • Dicyanate-clay nanocomposite has been prepared by a melt in-situ polymerization method for different modifiers and cation exchange capacity (CEC) values in order to study dispersion and mechanical property. Various dicyanate nanocomposites were prepared by using different MMT systems containing different intercalants which led to different initial gallery heights and packing density. Depending on compatibility between dicyanate and clays, the degree of dispersion varied. Dispersion of clay plates in dicyanate resin depended mainly on CEC and aliphatic chain length of modifier. The lower CEC and shorter aliphatic chain length of modifier gave the exfoliation structure. It was also found that the reactivity of intercalant with dicyanate resin was one of the key factors facilitating the intercalation/exfoliation process of dicyanate/MMT nanocomposites. Shear modulus of reaction-induced dicyanate nanocomposite was significantly increased.