• Title/Summary/Keyword: evaporation loss

Search Result 163, Processing Time 0.02 seconds

Quality of Ginger Powder as Affected by Concentration and Dehydration Methods of Ginger Extracts (농축 및 건조방법에 따른 생강 추출액 분말의 품질변화)

  • Jeong, Moon-Cheol;Jeong, Seong-Weon;Lee, Young-Chun
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.1589-1595
    • /
    • 1999
  • Reverse osmosis(RO) and rotary evaporation, freezer drying and spray drying as concentration and dehydration methods were, respectively, employed to investigate their effect on the flavor quality of ginger powder. Rotary evaporation and spray drying methods were more effective to restrict the browning of ginger powder than RO and freezer drying methods. Concentration methods had no effect on the free amino acids and free sugar contents of ginger powder, but freezer drying resulted in the less quality loss than spray drying. And the powder prepared from enzymatically hydrolyzed extract contained less crude protein, crude ash, browning and the changes in free amino acids, but had more the crude fat, solubility and free sugars than that from ginger extract obtained by filter press. Sensory results indicated that quality of ginger powder prepared by RO concentration and freeze drying of enzymatically hydrolyzed extract was as good as that without enzyme hydrolysis

  • PDF

Experimental Validation on Performance of Waste-heat-recovery Boiler with Water Injection (물분사 폐열회수 보일러의 효용성에 대한 실험적 검증)

  • Jaehun Shin;Taejoon Park;Hyunseok Cho;Junsang Yoo;Seoksu Moon;Changeon Lee
    • Journal of ILASS-Korea
    • /
    • v.28 no.1
    • /
    • pp.43-48
    • /
    • 2023
  • The waste-heat-recovery boiler with water spray (HR-B/WS) applies the heat exchange between the inlet air and exhaust gas with the water spray into the inlet air. The evaporation of water in the inlet air promotes heat recovery from the exhaust gas so that thermal efficiency can be improved by the enhanced condensing effect. The NOx emission can also be reduced by lowering the flame temperature due to the dilution effect of the water. In this study, the validity of this concept is examined by the practical boiler test performed with a 24 kW condensing boiler under the full load condition according to the water injection amount. The theoretical amount of water injection is calculated under the assumption of full evaporation of the sprayed water, which is calculated as 50 g/min. Since the injected water cannot evaporate fully in the actual system, the maximum water spray amount is set as 100 g/min. The results showed that the water injection can increase the thermal efficiency up to 95.59% and reduce NOx and CO emissions simultaneously to 8.9 ppm and 35 ppm at 0% of O2. Although the heat energy loss increased due to the unevaporated water, the increase in water injection amount caused higher thermal efficiency due to the increased amount of the evaporated water.

Comparative Biodegradation of HDPE and LDPE Using an Indigenously Developed Microbial Consortium

  • Satlewal, Alok;Soni, Ravindra;Zaidi, Mgh;Shouche, Yogesh;Goel, Reeta
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.3
    • /
    • pp.477-482
    • /
    • 2008
  • A variety of bacterial strains were isolated from waste disposal sites of Uttaranchal, India, and some from artificially developed soil beds containing maleic anhydride, glucose, and small pieces of polyethylene. Primary screening of isolates was done based on their ability to utilize high- and low-density polyethylenes (HDPE/LDPE) as a primary carbon source. Thereafter, a consortium was developed using potential strains. Furthermore, a biodegradation assay was carried out in 500-ml flasks containing minimal broth (250ml) and HDPE/LDPE at 5mg/ml concentration. After incubation for two weeks, degraded samples were recovered through filtration and subsequent evaporation. Fourier transform infrared spectroscopy (FTIR) and simultaneous thermogravimetric-differential thermogravimetry-differential thermal analysis (TG-DTG-DTA) were used to analyze these samples. Results showed that consortium-treated HDPE (considered to be more inert relative to LDPE) was degraded to a greater extent (22.41% weight loss) in comparison with LDPE (21.70% weight loss), whereas, in the case of untreated samples, weight loss was more for LDPE than HDPE (4.5% and 2.5%, respectively) at $400^{\circ}C$. Therefore, this study suggests that polyethylene could be degraded by utilizing microbial consortia in an eco-friendly manner.

Reduction Characteristics of Pool Top Radiation Level in HANARO (하나로 수조 방사선 준위의 저감 특성)

  • Park, Yong-Chul
    • The KSFM Journal of Fluid Machinery
    • /
    • v.5 no.1 s.14
    • /
    • pp.49-54
    • /
    • 2002
  • HANARO, 30 MW of research reactor, was installed at the depth of 13m in an open pool. The $90\%$ of primary coolant was designed to pass through the core and to remove the reaction heat of the cote. The rest, $10\%$, of the primary coolant was designed to bypass the core. And the reactor coolant through and bypass the core was inhaled at the top of chimney by the coolant pump to prevent the radiated gas from being lifted to the top of reactor pool. But, the part of core bypass coolant was not inhaled by the reactor coolant pump and reached at the top of reactor pool by natural convection, and increased the radiation lovel on the top of reactor pool. To reduce the radiation level by protecting the natural convection of the core bypass flow, the hot water layer (HWL, hereinafter) was installed with the depth of 1.2 m from the top of reactor pool. As the HWL was normally operated, the radiation level was reduced to five percent ($5\%$) in comparing with that before the installation of the HWL. When HANARO was operated at a higher temperature than the normal temperature of the HWL by operating the standby heater, it was found that the radiation level was more reduced than that before operation. To verify the reason, the heat loss of the HWL was calculated by Visual Basic Program. It was confirmed through the results that the larger the temperature difference between the HWL and reactor hall was, the more the evaporation loss increased. And it was verified that the radiation level above was reduced mote safely by increasing the capacity of heater.

Reduction Characteristics of Pool Top Radiation Level in HANARO (하나로 수조 방사선 준위의 저감 특성)

  • Park, Yong-Chul
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.221-226
    • /
    • 2001
  • HANARO, 30MW of research reactor, was installed at the depth of 13m of open pool, The $90\%$ of primary coolant was designed to pass through the core and to remove the reaction heat of the core. The rest $10\%$, of the primary coolant was designed to bypass the core. And the reactor coolant through and bypass the core was inhaled at the top of chimney by the coolant pump to protect that the radiated gas was lifted to the top of reactor pool. But, the part of core bypass coolant was not inhaled by the reactor coolant pump and reached at the top of reactor pool by natural convection and increased the radiation level on the top of reactor pool. To reduce the radiation level by protecting the natural convection of the core bypass flow, the hot water layer (HWL, hereinafter) was installed with the depth of 1.2m from the top of reactor pool. As the HWL was normally operated, the radiation level was reduced to five percent ($5\%$) in comparing with that before the installation of the HWL. When HANARO was operated with higher temperature than the normal temperature of the HWL by operating the standby heater, it was found that the radiation level was more reduced than that before operation. To verify the reason, the heat loss of the HWL was calculated. It was confirmed through the results that the larger the temperature difference between the HWL and reactor hall was, the more the evaporation loss was increased. And it was verified that the radiation level above was reduced more safely by increasing the capacity of heater.

  • PDF

The Relationship between Fat Level and Quality Properties of Ground Pork Patties Cooked by Microwave Energy (전자레인지 가열시 분쇄 돈육 패티의 지방함량과 가열특성과의 상관관계에 관한 연구)

  • Choi, Ji-Hyun;Jeong, Jong-Youn;Choi, Yun-Sang;Lee, Eui-Soo;Kim, Cheon-Jei
    • Food Science of Animal Resources
    • /
    • v.28 no.3
    • /
    • pp.295-300
    • /
    • 2008
  • This study was carried out to elucidate the relationship between different fat levels (0%, 5%, 10%, 15%, 20%, and 25%) and the quality of ground pork patties cooked to reach an internal temperature of $75^{\circ}C$ in a microwave oven. The relationship between fat level and cooking rate of pork patties cooked by microwave energy was highly significant ($R^2=0.72$), and had a low determination coefficient ($R^2=0.55$). The relationship between fat level and total cooking loss of pork patties cooked by microwave energy was also very significant, with a high correlation coefficient of $R^2=0.89$. The correlation coefficient between fat level and cooking drip loss of patties cooked by microwave energy was 0.92, which was highly significant. Although the correlation coefficient between fat level and evaporation loss had a negative value ($R^2=-0.63$), there was a highly significant relationship between fat level and shear force of pork patties cooked by microwave energy.

Volatility of Herbicides Sprayed in Zoysia japonica Turf and Bare Soil (잔디밭과 나지에 산포된 주요 잔디밭용 제초제의 휘산)

  • 김석정;박진희;죽내안지;김길웅;신동현;허영조
    • Asian Journal of Turfgrass Science
    • /
    • v.10 no.3
    • /
    • pp.263-270
    • /
    • 1996
  • This experiment was conducted to investigate the loss of various herbicides by means of vola-tility from the turfgrass field and the hare ground with the different soil moisture contents and temperatures. Different herbicides were applied at the rates of 375 g a.i. /l0a of pendimethalin,250 g a.i. /l0a of napropamide, and 96.4 g a.i. /l0a of dicamba with 200 \ulcorner/10a of spray volume in the turfgrass(Zoysia japonica cut off 5cm) grown in pots(265.8 $cm^2$) and bared soil. The pots were placed in the growth chamber with 10,000 lux of light intensity(12h per day) at 25 and 35˚C for 7days. Amberlite XAD polymeric resin(20/50 mesh) was used as sampling media for herbicide airborne residues. Air flow was maintained at 10 \ulcorner /min by vacuum pump regulated with a factory calibrated flow meter. Herbicide airborne residues were extracted from the XAD resin with 300 ml of 1:1 acetone and hexane. The extracts were concentrated by rotary evaporation at 35˚C and dissolved in 1 ml MeCN for HPLC analysis. The airborne losses of the herbicide applied in the turfgrass and bare soil increased as the temperature and soil moisture contents were increased, regardless of the kinds of herbicide. Higher airborne residues was observed in the turfgrass pots than the bare soil pots. Pendimethalin and dicamba with higher vapor pressure gave rise to the increased loss of airborne herbicides, showing that 6.26 and 6.4% of average airborne loss in pendimethalin and dicamba, respectively, compared to 0.56% in napropamide. The amount of airborne losses in turfgrass was highest at one day after application and then a declined trend was observed as the time was prolonged. Key words. Herbicides, Turfgrass field, Bare ground, Volatility.

  • PDF

Correlation between Meteorological Factors and Water Discharge from the Nakdong River Barrage, Korea (낙동강 하구역 해양물리환경에 미치는 영향인자 비교분석(I) - 하구둑 방류량과 기상인자 -)

  • Park, San;Yaan, Han-Sam;Lee, In-Cheal;Kim, Hean-Tae
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.14 no.2
    • /
    • pp.111-117
    • /
    • 2008
  • We estirmted the yearly and monthly variation in discharge from the Nakdong River Barrage. We studied the total monthly discharge, the mean daily discharge, and the maximum daily discharge based on the observational discharge data for the 11-year period 1996-2006. We also examined the correlation between the discharge and the meteorologiml factors that influence the river inflow. The results from this study are as follows. (1) The total monthly discharge for 11 years at the Nakdong River Barrage was $224,576.8{\times}10^6\;m^3$: The daily maximum was in 2003, with $56,292.3{\times}10^6\;m^3$. The largest daily mean release discharges occurred in August with $52,634.2{\times}10^6\;m^3$ (23.4% of the year), followed by July and September in that order with 23.1 and 17%, respectively. (2) The monthly pattern of discharge could be divided into the flood season for the period July-September (discharge =$1000{\times}10^6\;m^3$/day), the normal season from April to June and October (discharge=$300{\times}10^6\;m^3$/day), and the drought season from December to March (discharge < $300{\times}10^6\;m^3$/day). (3) Periods of high temperature, low evaporation loss, and short sunshine duration produced a much higher discharge in general. Conditions of low rainfall and high evaporation loss, as was the rose in 2003, tended to reduce the discharge, but high rainfall and low evaporation loss tended to increase the discharge as it did in 200l. (4) The dominant wind directions during periods of high discharge were NNE (15.5%), SW and SSW (13.1%), S(12.1%), and NE (10.8%) This results show that it run bring on accumulation of fresh water when northern winds are dominant, and it run flow out fresh water toward offslwre when southern winds are dominant.

  • PDF

Measurement of R-134a Leakage from Vehicle Equipped Mobile Air Conditioning(MAC) System (실차를 이용한 자동차 에어컨 냉매 누출량 평가)

  • Kim, Ji Young;Seo, Chungyoul;Lee, Sangeun;Kim, Jeongsoo
    • Journal of Climate Change Research
    • /
    • v.3 no.2
    • /
    • pp.153-159
    • /
    • 2012
  • CFC-12 used in mobile air conditioning(MAC) system has been replaced by R-134a, a type of HFC refrigerant, from 1991 to 1994. R-134a has since been widely used as a refrigerant of a mobile air conditioner. However, it is one of the six main green house gases listed in Kyoto Protocol, which makes it imperative to regulate its emission and develop alternative refrigerants. In this study, the concentration of leaked R-134a was measured using VT(Variable Temperature) shed and Running loss test shed to analyze the level of air conditioner refrigerant leaked in a vehicle. According to the analysis of the concentration of R-134a leaked from a vehicle parked, annual leakage amount of R-134a was in the range of 6.46~13.28 g/yr. The figure was similar with the leakage from the mobile air conditioning system currently used. In a study using the same vehicle model, a vehicle equipped with dual evaporation system had a higher leakage rate of refrigerant than a vehicle with a single evaporation system. It appears that the added fittings and joints of the dual evaporator system led to higher leakage rate. Besides, the analysis of the change in R-134a concentration under various car speed found that more refrigerant leaked under high speed(100km/hr) and but the volume of the wind did not affect to the variation of refrigerant leakage.

Loss of Metalworking Fluids Collected on PVC Filter Due to Contact with Clean Air and Desiccation (PVC필터에 채취된 절삭유의 손실에 관한 연구)

  • Park, Dong-Uk;Ha, Kwon-Chul
    • Analytical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.451-457
    • /
    • 2001
  • Because liquids with high molecular weight such as mineral oil have low vapor pressure at room temperature, it is generally thought to be difficult to lose them to evaporation. However, when they are dispersed into air in small droplets during application in machining processes, their surface area becomes considerably higher. To determine the potential for metalworking fluids (MWF) filter losses, MWF mist was generated and collected on polyvinyl chloride (PVC) filters in test chamber. After collected MWF was exposed to clean air during designated period (range 10~240 minutes) and the filters were desiccated, losses were evaluated. As duration of clean air passing through PVC filter increased, loss of MWF gradually increased. MWF lost after 10 minutes ranged form 12.4 % to 21.8 % of the original loading mass, on average 53.3 % of the total loss. These results indicate that significant mass of MWF collected on PVC filters can be lost at the beginning of air sampling. Loss of MWF collected on PVC filter also occurred during desiccation without active airflow. In multiple regression to identify which factors influence the loss of MWF collected on PVC filter, both duration of air passing through PVC filter and MWF age (fresh vs. used) were significant predictor (p=0.0001). Therefore, workers' exposure to MWF measured method 0500, may underestimate true concentration. Further study is needed to develop a new method to quantify the workers' exposure to airborne MWF mist accurately.

  • PDF