• Title/Summary/Keyword: evaluation scale

Search Result 4,701, Processing Time 0.038 seconds

Design and Performance Evaluation of Fiber Optic Gyro with Digital Closed-loop Processing (디지털 폐루프 신호처리를 적용한 광섬유 자이로 설계 및 성능평가)

  • 도재철;정경호
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.9
    • /
    • pp.97-103
    • /
    • 2006
  • This paper described the design and performance evaluation of fiber optic gyro using digital closed-loop processing. For the feedback to null the gyro input rate, digital serrodyne modulation was employed, and for scale factor stabilization, the control circuits of modulation amplitude and optical power are implemented. Performance tests show that prototype fiber optic gyro has bias stability of 0.34 deg/hr, scale factor non-lineality of about 100ppm, and maximum measurement range of ${\pm}500$ deg/sec.

A study on the acoustical-design for PANSORI hall (한국창악공연장의 음향설계연구)

  • 최석주;박병전
    • The Journal of the Acoustical Society of Korea
    • /
    • v.3 no.2
    • /
    • pp.3-12
    • /
    • 1984
  • This paper is to suggest the optimum structure and the rating scale of PANSORI hall. The method of this study is as follows. 1. Consideration for the characteristics of OPANSORI and Beranek's music & acoustic theory. 2. To take advice from the expert. 3. The experiment and evaluation of a model. 4. The structure of PANSORI hall and the study of the availability in Beranek's rating scale of orchestra and opera. 5. The establishment of the rating scale in PANSORI hall. 6. The evaluation of the forms of performance in each hall. The result of this study, the proper hall in the performance of PANSORI is, 1. The initial time delay gap less than 25ms. 2. The reverberation time of the extents of 1.2 seconds. 3. The proper average bass ratio of 1.25 extents. 4. The distance from performers to audience is within 30 meters. 5. THE VOLUME OF HALL IS 450-7400 ㎥ extents. 6. It should be designed not to be a acoustical disturbancenoise, echo, and the unbalance of sound pressure level, etc.

  • PDF

Evaluation of the City Residents' images on the Landscape of the Rural Traditional Theme Village (농촌전통마을 경관에 대한 도시주민의 이미지 평가)

  • Kim, Ick-hwan;Hong, Kyoung-youn;Jang, Han-seub;Kim, Chun-il
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.12 no.4
    • /
    • pp.221-228
    • /
    • 2009
  • This study analyzes the behaviors and images of city residents on the six Gyeongsangbuk-do rural theme villages. The results of analysis bring the following conclusions. 1) Behaviors of city residents are related with the images on rural villages. In addition, the better the image is, the higher their behaviors' needs. 2) Behaviors' needs become higher on the village as the image on 'Scale type' becomes better. 3) Especially, in case of Gimcheon and Gyeongju, we find a strong relationship between the images of 'Scale type' and 'Magnificent type' and behaviors; these villages should raise the scale and standard of villages by certain point.

  • PDF

A Study on Securing Objectivity in Small-Scale Environmental Impact Assessments Using Delphi Analysis

  • Dong-Myung CHO;Ju-Yeon LEE;Woo-Taeg KWON
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.7 no.3
    • /
    • pp.73-95
    • /
    • 2024
  • Purpose: Since August 2000, the small-scale environmental impact assessment system has prevented indiscriminate development. However, its qualitative reports lack objectivity and consistency. This study analyzes these issues through literature and expert surveys and proposes improvements. Research Methodology: Samples were selected based on regional consultation numbers. Mitigation measures were categorized into qualitative and quantitative factors. Issues were identified, and improvements suggested. The Delphi method helped select evaluation items and propose a scoring table. Results and Conclusions: The Delphi method selected 14 absolute and 22 relative evaluation items, excluding 3 invalid ones. A 100-point scoring table was created, with points assigned based on element significance. A 1-point bonus was added for top-scoring elements to promote eco-friendly planning.

Performance Improvement of Packet Loss Concealment Algorithm in G.711 Using Adaptive Signal Scale Estimation (적응적 신호 크기 예측을 이용한 G.711 패킷 손실 은닉 알고리즘의 성능향상)

  • Kim, Tae-Ha;Lee, In-Sung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.5
    • /
    • pp.403-409
    • /
    • 2015
  • In this paper, we propose Packet Loss Concealment (PLC) method using adaptive signal scale estimation for performance improvement of G.711 PLC. The conventional method controls a gain using 20 % attenuation factor when continuous loss occurs. However, this method lead to deterioration because that don't consider the change of signal. So, we propose gain control by adaptive signal scale estimation through before and after frame information using Least Mean Square (LMS) predictor. Performance evaluation of proposed algorithm is presented through Perceptual Evaluation of Speech Quality (PESQ) evaulation.

The Evaluation of Fire Safety Performance on Interior Finish Materials (Gypsum Board, Plywood) (건물내장재(석고보드, 합판)의 화재성능평가)

  • 김충환;김종훈;김운형;하동명;이수경
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.55-62
    • /
    • 2001
  • The fire performance evaluation methods in Korea and overseas for interior finish materials were analysed and tested with gypsum board and Plywood by using room corner test not adopted by domestic code until now. The results of gypsum board (thickness:8 mm) and Plywood (thickness:4 mm) applying NFPA 265 and ISO 9705 test respectively are satisfied the assessment criteria. To assess a actual fire performance and classify fire hazard levels for interior finish materials, room-corner test and flame spread models should be adopted in building code and fire code to overcome limitations of current bench-scale test method.

  • PDF

Real-time large-scale hybrid testing for seismic performance evaluation of smart structures

  • Mercan, Oya;Ricles, James;Sause, Richard;Marullo, Thomas
    • Smart Structures and Systems
    • /
    • v.4 no.5
    • /
    • pp.667-684
    • /
    • 2008
  • Numerous devices exist for reducing or eliminating seismic damage to structures. These include passive dampers, semi-active dampers, and active control devices. The performance of structural systems with these devices has often been evaluated using numerical simulations. Experiments on structural systems with these devices, particularly at large-scale, are lacking. This paper describes a real-time hybrid testing facility that has been developed at the Lehigh University NEES Equipment Site. The facility enables real-time large-scale experiments to be performed on structural systems with rate-dependent devices, thereby permitting a more complete evaluation of the seismic performance of the devices and their effectiveness in seismic hazard reduction. The hardware and integrated control architecture for hybrid testing developed at the facility are presented. An application involving the use of passive elastomeric dampers in a three story moment resisting frame subjected to earthquake ground motions is presented. The experiment focused on a test structure consisting of the damper and diagonal bracing, which was coupled to a nonlinear analytical model of the remaining part of the structure (i.e., the moment resisting frame). A tracking indictor is used to track the actuator ability to achieve the command displacement during a test, enabling the quality of the test results to be assessed. An extension of the testbed to the real-time hybrid testing of smart structures with semi-active dampers is described.

Hand Assessment for Women's Spring-Fall Dress Fabrics(Part 1) - Development for the Subjective Hand Evaluation Scale - (여성용 춘추복지의 태에 관한 연구(제1보) -태의 주관적 평가척도 개발을 중심으로-)

  • 홍경희;김재숙
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.18 no.3
    • /
    • pp.327-338
    • /
    • 1994
  • KES-F system is widely used in hand evaluation, however, it has encountered some challenges, such as the overlapping of primary hand value, lack of predictability in case of women's thin dress, difficulties in communication due to complexity of primary hand expression and cultural differences in subjective evaluation. Therefore, this study was intended 1) to find out the Korean primary hand expressions(factors) of the overall concept of fabric hand associated with women's spring- fall dress fabrics, 2) to develope the fabric hand attributes of those fabrics and 3) to show whether there are any differences between Korean textile experts and non-experts in terms of the concept of fabric hand descriptors of hand attributes. Data base of hand descriptors were collected by extensive interview 60 experts and 10 non - experts using 110 spring-fall dress fabrics. Finally, hand of selected fabrics was assessed by 205 experts and 265 non-experts using 7-point scale of 26 descriptors based on the data base. Subjective ratings were analyzed by common factor analysis with varimax rotation. It was found that Korean primary hand expression indicated rather simple property, hence, did not equate exactly with Japanese experssion(e.g. koshi, shinayakasa, etc.) which contains several material properties. There were differences in stretch IE resilience, especially liveliness, between the judgement of non- ex- pert than to experts. Surface- related category was more important to non-experts than to experts. Slight differences were found between both groups in terms of preferred descriptors. Important descriptors as a rating scale were suggested.

  • PDF

Methodological Development of Physical Environment Rating Scale for Interior Space of Child Care Facility (아동 보육시설 실내환경 평가 도구 개발)

  • 이수진
    • Korean Institute of Interior Design Journal
    • /
    • no.33
    • /
    • pp.27-35
    • /
    • 2002
  • The qualify of preschool education is related to the qualify of the physical environment, This research is aiming to develop and validate the set of scales for the measurement of physical quality of the interior spaces in child care facilities. The research has been in three major phases: (1)the development of indicative sub-scales for the description, measurement and evaluation of the physical designed quality of early childhood environments (2)two rounds of iterative phases of reliability and validity testing of the scales through expert panels and observational field-testing and (3)implications for future research to be done. 13 sub-scales were developed, which are based on Moore's 15 design principal for child care environments. And each sub-scale includes several evaluation items based upon developmental theory, existing empirical literature, and Korean, Australian and American child care standards. This set of scales will (1)aid research on the effects of environmental variables on quality of child care facilities for infants, toddlers, and preschoolers; (2)permit evaluation of such environments to identify areas of needed improvement; and (3)provide information for policy makers, parents, administrators, and designers/architects.

The Evaluation of Burst Pressure for Corroded Pipeline by Full Scale Burst Test (실배관 파열시험을 통한 부식배관의 파열압력 평가)

  • Kim, Yeong-Pyo;Baek, Jong-Hyeon;Kim, U-Sik;Go, Yeong-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.1
    • /
    • pp.203-210
    • /
    • 2002
  • The transmission pipeline industry spends many millions of dollars annually performing inline inspections, excavating sites of possible corrosion, and repairing or replacing damaged sections of pipe. New criteria fur evaluation of the integrity of corroded pipe have been developed in recent years to help in controlling these costs. These new criteria vary widely in their estimates of integrity and the most appropriate criterion fur a given pipeline is net always clear. This paper presents an overview, comparison and evaluation of acceptability criteria for corrosion deflects in pipelines. By full scale burst tests, this paper has assessed the relative accuracy of each of theses criteria in predicting burst pressure. Many of the criteria appear to be excessively conservative and indicate that deflects must be repaired when none is needed, based upon burst test data.