• Title/Summary/Keyword: evaluation for comfort

Search Result 618, Processing Time 0.029 seconds

Evaluation of a Curtain-Type Radiation Protection Device for Veterinary Interventional Procedures

  • Minsik Choi;Jaepung Han;Changgyu Lim;Jiwoon Park;Sojin Kim;Uhjin Kim;Jinhwa Chang;Dongwoo Chang;Namsoon Lee
    • Journal of Veterinary Clinics
    • /
    • v.41 no.3
    • /
    • pp.157-164
    • /
    • 2024
  • The standard radiation protection method in the angiography suite involves the use of a thyroid shield, a lead apron, and lead glasses. However, exposure to substantial amounts of ionizing radiation can cause cataracts, tumors, and skin erythema. A newly developed curtain-type radiation protection device consists of a curtain drape composed of a five-layer bismuth and lead acrylic head-shielding plate, with both bearing an equivalent 0.25 mm lead thickness. In this study, a quality assurance phantom was used as the patient to create radiation scatter from the radiographic source, and an anthropomorphic mannequin phantom was used as the interventionalist to measure the radiation dose at seven different anatomical locations. Thermoluminescent dosimeters were used to measure the radiation dose. The experimental groups consisted of all-sided or one-sided curtain set-ups, the presence or absence of a conventional shielding system, and the orientation of beam irradiation. Consequently, the curtain-type radiation protection device exhibited better radiation protection range and capabilities than conventional radiation protection systems, especially in safeguarding the forehead, eyes, arms, and feet, with minimal radiation exposure. Moreover, the mean shielding ratios of the conventional shielding system and curtain-type radiation protection device were measured at 51.94% and 93.86%, respectively. Additionally, no significant decrease in the radiation protection range or capability was observed, even with changes in the beam orientation or one-sided protection. Compared with a conventional shielding system, the curtain-type radiation protection device decreased radiation exposure doses and improved comfort. Therefore, it is a potential new radiation protection device for veterinary interventional procedures.

The evaluation for usefulness of the custom made immobilization device for the anteroperitoneal resection patients with rectal cancer (복 회음부 절제술 환자를 위한 고정용구 제작 및 유용성 평가)

  • Yang Oh Nam;Lee Woo Seok;Hong Tack Kyun;Jo Young Pil;Yun Hwa Ryong;Kim Jung Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.61-65
    • /
    • 2003
  • I. Purpose Patient immobilization is essential factor for successful radiation therapy and major problem is reproducibility to maintain patient position during total radiation therapy period. Purpose of this study is evaluation for usefulness of the custom made immobilization device for the anteroperitoneal resection patients with rectal cancer II. Materials and Methods The object of this study were patients who underwent anteroperitoneal resection and undergo radiation therapy at present with rectal cancer. We made immobilization device for patient individually and analyzed its set up reproducibility, patient position deviation and errors. III. Results There was $5mm{\sim}10mm$ deviation in patient position without individual immobilization device, but we improved the deviation within few mm limitation with individual immobilization device. IV. Conclusion Custom made immobilization device was very helpful for anteroperitoneal resection patient with rectal cancer. We improved the patient position deviation within few mm limitation, shorten the set up time and we could give the comfort to patients.

  • PDF

Evaluation of the Wet Bulb Globe Temperature (WBGT) Index for Digital Fashion Application in Outdoor Environments

  • Kwon, JuYoun;Parsons, Ken
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.1
    • /
    • pp.23-36
    • /
    • 2017
  • Objective: This paper presents a study to evaluate the WBGT index for assessing the effects of a wide range of outdoor weather conditions on human responses. Background: The Wet Bulb Globe Temperature (WBGT) index was firstly developed for the assessment of hot outdoor conditions. It is a recognised index that is used world-wide. It may be useful over a range of outdoor conditions and not just for hot climates. Method: Four group experiments, involving people performing a light stepping activity, were conducted to determine human responses to outside conditions in the U.K. They were conducted in September 2007 (autumn), December 2007 (winter), March 2008 (spring) and June 2008 (summer). Environmental measurements included WBGT, air temperature, radiant temperature (including solar load), humidity and wind speed all measured at 1.2m above the ground, as well as weather data measured by a standard weather station at 3m to 4m above the ground. Participants' physiological and subjective responses were measured. When the overall results of the four seasons are considered, WBGT provided a strong prediction of physiological responses as well as subjective responses if aural temperature, heart rate and sweat production were measured. Results: WBGT is appropriate to predict thermal strain on a large group of ordinary people in moderate conditions. Consideration should be given to include the WBGT index in warning systems for a wide range of weather conditions. However, the WBGT overestimated physiological responses of subjects. In addition, tenfold Borg's RPE was significantly different with heart rate measured for the four conditions except autumn (p<0.05). Physiological and subjective responses over 60 minutes consistently showed a similar tendency in the relationships with the $WBGT_{head}$ and $WBGT_{abdomen}$. Conclusion: It was found that either $WBGT_{head}$ or $WBGT_{abdomen}$ could be measured if a measurement should be conducted at only one height. The relationship between the WBGT values and weather station data was also investigated. There was a significant relationship between WBGT values at the position of a person and weather station data. For UK daytime weather conditions ranging from an average air temperature of $6^{\circ}C$ to $21^{\circ}C$ with mean radiant temperatures of up to $57^{\circ}C$, the WBGT index could be used as a simple thermal index to indicate the effects of weather on people. Application: The result of evaluation of WBGT might help to develop the smart clothing for workers in industrial sites and improve the work environment in terms of considering workers' wellness.

The Occlusal Evaluation and Treatment Planning for Prosthodontic Full Mouth Rehabilitation (보철학적 교합 재구성을 위한 교합진단과 치료계획)

  • Lee, Seung-Kyu;Lee, Sung-Bok;Choi, Dae-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.2
    • /
    • pp.149-159
    • /
    • 2000
  • Occlusal disease is comparable to periodontitis in that it is generally not reversible. Occlusal disease, however, like periodontitis, often maintainable. It does itself to treatment and when restorative dentistry is utilized it becomes, in that sense, reversible. Moreover, a systematized and integrated approach will lead to a prognosis that is favorable and predictable. This approach facilitates development of optimum oral function, comfort, and esthetics, resulting in a satisfied patient. Such a systematized approach consists of four logical phase : (1) patient evaluation, (2) comprehensive analysis and treatment planning, (3) integrated and systematic reconstruction, and (4) postoperative maintenance. An integrated treatment plan is first developed on one set of diagnostic casts, properly mounted on a semiadjustable articulator using jaw relationship records. This is accomplished by using wax to make reconstructive modifications to the casts. These modified casts become the blueprint for planned occlusal changes and the fabrication of provisional restorations. The treatment goals are : (1) comfortably functioning temporomandibular joints and stomatognathic musculature, (2) adherence to the basic principle of occlusion advocated by Schuyler, (3) anterior guidance that is in harmony with the envelope of function, (4) restorations that will not violate the patient's neutral zone. This report shows the treatment procedures for a patient whose mandibular position has been altered due to posterior bite collapse. Migration of the maxillary anterior teeth had occurred, and the posterior occlusal contacts showed pathologic interference. Precise diagnosis using mounted casts was executed and prosthodontic reconstruction by the aid of an unconventional orthodontic correction on maxillary flaring was planned. An unconventional orthodontic correction can be accomplished by using preexisting natural teeth, which can be modified for use in active tooth movement or splinted together for orthodontic anchorage. This technique has an advantage over conventional fixed appliance orthodontic therapy because it can accomplish tooth movement concurrently with restorative and periodontal therapy. On occasion, minor tooth movement can be necessary to achieve the optimum occlusal scheme, crown form, and tooth position for the forces of occlusion to be displaced down the long axis of the periodontally compromised teeth. Once the occlusion, periodontal health, and crown contours for the provisional splinted restoration are acceptable, the final splinted restoration can be similarly fabricated, and it becomes an excellent orthodontic retainer.

  • PDF

A Study on Improvement of Site Selecting Indicators for Safe Pedestrian Environment (안전한 보행환경 사업 대상지 선정지표 개선방안 연구)

  • Lee, Jong Nam;Heo, Joon;Cho, Won Cheol;Lee, Tae Shik
    • Journal of Korean Society of Disaster and Security
    • /
    • v.6 no.1
    • /
    • pp.79-86
    • /
    • 2013
  • As car-oriented road policies have been made forward so far, relatively pedestrians' walking conditions are so in poor environments that more than two thousand pedestrians die from car accidents every year. Pedestrians' walking right has been severely invaded like that. Pedestrians' walking right is a right that people are able to walk safely and comfortably in pleasant surroundings as long as they don't threaten the public safety, order maintenance, and welfare. The government has an obligation to provide safe, comfortable, and pleasant environments to pedestrians. Recently interests in pedestrians' safety are increasing, government-driven supports have been made to make safe, pleasant, and healthy walking surroundings. As poor walking condition improvement projects cost high, they should be progressed to accomplish maximal effects using finite finances efficiently, and post feasibility evaluations of the projects should be severely estimated. However site selecting indicators which satisfy with the goal for composing safe working surroundings have not been decided yet, though currently it has a legal basis to specify walking condition improvement sites by the Law for Pedestrians' safety and Comfort Increasement. Therefore this study focuses on suggesting improved ways for selecting sites where pedestrians' safe environment project by reviewing previous research. When project sites are selected, evaluation indicators related to awareness survey of residents and history should be excluded, and disaster safety assessments for walking safety facilities, latent human hazards and natural disasters like a strong wind are proposed besides evaluations on pedestrians' safety and walking environment for matching with the purpose of the project to make safe working surroundings.

Evaluation of Non-slip for Vehicle's Environmental Sub-Mat (자동차용 친환경적인 Sub-Mat의 Non-Slip기능 평가)

  • Eo, Yu-Rim;Kim, Ki-Tai;Kim, Joo-Yong;Kim, Young-Su
    • Science of Emotion and Sensibility
    • /
    • v.15 no.2
    • /
    • pp.177-182
    • /
    • 2012
  • Automotive sub-mat carpet for convenience and comfort of floor administration is additional supplemented floor mat. Sub Mat Backing of the current vehicle's materials reclaimed rubber, PVC, etc. are used, but secondary rubber and PVC Backing have bad sound absorption. Also rubber is heavy too. Contact surfaces between PET staple fiber, PET non-woven, PVC backing and car's floor carpet was measured the coefficient of friction for each sub-mat's non-slip evaluation. A surface of PET non-woven sub-mat has the highest coefficient of friction. Each of sample was observed by optical microscope the contact surfaces before and after. Contact surfaces of PET staple fiber sub-mat was changed increasingly to non-woven. This fact is shown that the sub-mat would be tangled between its contact surface and top of the floor carpet. It is expected to be highly non-slip. In case of PET non-woven sub-mat had not different for contact surfaces between before and after. And PVC backing was shown lower non-slip than other samples. The result of optical microscope and coefficient of friction is seems to be related.

  • PDF

Ergonomic Design of Office Chair (사무실 의자의 인간공학적 디자인)

  • 곽원모;홍성수;정석길;이상도;이동춘;윤훈용
    • Archives of design research
    • /
    • v.12 no.3
    • /
    • pp.73-80
    • /
    • 1999
  • Many domestic users complain about severe pain to the waist, neck, and shoulder as well as work performance because the domestic chair design was developed with western anthropometry dimension and design criteria. Ergonomic design standards are needed for office chair design to reduce stress and poor physical posture for various user body types. In this study, we have suggested design dimensions recommended from previous studies and Korean anthropometry data. We also have reviewed users' preference dimension through measured subjects and analyzed differences between users' preference dimension and the previous design criteria to verify physical appropriateness. We evaluated general office chairs and adjustable chairs which can adjust to fit each person. we also analyzed how each design dimension was reached and affected the human body by evaluation of physical discomfort and comfort. We have found seat height is very important in a workstation. If the seat height is high, it effects the thigh. If width, height, and angle of the backrest are wrong, fatigue to the shoulder, neck, and waist, etc.. As a result of this experiment, we suggested that the height of a seat for Koreans be 425mm for the fixed type and 365-484mm for the adjustable type. Also other design recommendations were suggested in the thesis. In conclusion, our research will be very important in the database because it provides adjustable ranges to fit user's body types in the various design fields.

  • PDF

Performance Evaluation of the Capillary Tube Radiant Floor Cooling & Heating System (모세유관 바닥복사 냉·난방 시스템의 성능평가)

  • Seo, Yu-jin;Kim, Taeyeon;Leigh, Seung-bok
    • KIEAE Journal
    • /
    • v.12 no.4
    • /
    • pp.89-95
    • /
    • 2012
  • At present, many countries are trying to reduce green gas emissions to mitigate the effects of these gases on climate change. Year after year, there have been efforts to cut energy use for heating and cooling. Heating and cooling systems, common in all forms of housing, are increasing due to the constant supply of new housing resulting from improvements in economic growth and the quality of life. Thus, studies related to the design of cooling and heating systems to improve energy efficiency are expanding. Among the new designs, radiant floor cooling and heating systems which use capillary tubes are becoming viable means of reducing energy use. Radiant floor cooling and heating systems which use capillary tubes are creative and sustainable systems in which cool and hot water is circulated into capillary tube which has small diameter. In this study, the cooling and heating performance of this type of capillary tube system is investigated in an experimental study and a simulation using TRNSYS. The results of the experimental study show that under a peak load, a capillary tube radiant floor cooling system using geothermal energy can achieve desired indoor temperature without an additional heat source. The set room air temperature is maintained while the floor surface temperature, PMV and PPD remain within the comfort range. Also, this system is more economic than a packaged air conditioner system due to its higher COP. The results of the simulation show that the capillary tube radiant floor heating system maintains set temperature more stable than a PB pipe radiant floor heating system due to its lower supply temperature of hot water. In terms of energy consumption, the capillary tube radiant floor heating system is more efficient than the PB pipe radiant floor heating system.

Congenital Polydactyly of the Foot (선천성 족부 다지증)

  • Hwang, Kuhn-Sung;Kim, Tae-Seung;Sung, Il-Hoon;Park, Jun-Sic
    • Journal of Korean Foot and Ankle Society
    • /
    • v.5 no.2
    • /
    • pp.120-128
    • /
    • 2001
  • Purpose: This study was undertaken to review the precise morphological patter'ns of polydactyly of the foot and to evaluate outcomes of surgical interventions. Materials and Methods: The records of patients who had polydactyly of foot from 1983 to 2000 were reviewed retrospectively. 29 duplicated toes(24 patients) were analyzed. All cases were evaluated and classified with Temtamy and McKusick's axial pattern, Watanabe's morphologic pattern and level of duplication. Clinical evaluation was performed according to Phelps and Grogan's. Mean age at surgery was 5.7 years(range: 10 months$\sim21$ years). All the patients were subsequently evaluated during mean 17 months(range: 13 months-$\sim5$ years). Results: Preaxial polydactyly was seen in 3 cases, central polydactyly in 3 cases, postaxial polydactyly in 22 cases and remaining 1 case was multiple my involvement. Only 2 patients have familial history and the most common associated anomaly was hand deformity(20.8%). Clinical results were excellent in 14 cases, good in 5 cases, poor in one. 17 patients(70%) were operated before 6 years olds and they had better results than those of who were operated after 6 years olds. Conclusion: The Method of surgical correction for the polydactyly should be individualized by its morphological pattern because the purpose of operation was to give comfort in wearing shoes and patient's psychological relief. This study showed that polydactyly of the foot could be corrected surgically with good results in most cases, and the better results would be achieved if the operation is performed before preschool age according to its individualized pattern of duplication.

  • PDF

Light Pollution of Outdoor Lighting in Coastal Area - Focused on Busan City - (해안가 야간경관조명의 빛공해 평가 - 부산시를 중심으로 -)

  • Kong, Hyo-Joo;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.18-26
    • /
    • 2010
  • Outdoor lighting has become a necessary essential part of society for safety and comfortable space. However, inappropriate outdoor lighting leads to energy waste and poor landscape. Outdoor lighting is a very important social element, which enables us to conduct various activities at night in a safe, efficient and comfort way. River Thames in UK, Venice in Italy and Sydney in Australia is a good example of the coastal area. This paper aims to evaluate the light pollution of outdoor lighting in coastal area in Busan city. The Radiant Imaging ProMetric-1400 was used to measure the luminance of Gwangalli Beach, Marine City and Haeundae Beach. Compare to the CIE recommendation level the luminance of the all outdoor lighting were about 2~20 times higher. Outdoor lighting of the building facade luminance level and color should be particularly limited.