• Title/Summary/Keyword: evaluation case

Search Result 8,079, Processing Time 0.039 seconds

Performance Evaluation of Hydrocyclone Filter for Treatment of Micro Particles in Storm Runoff (Hydrocyclone Filter 장치를 이용한 강우유출수내 미세입자 제거특성 분석)

  • Lee, Jun-Ho;Bang, Ki-Woong;Hong, Sung-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.11
    • /
    • pp.1007-1018
    • /
    • 2009
  • Hydrocyclone is widely used in industry, because of its simplicity in design, high capacity, low maintenance and operational cost. The separation action of a hydrocyclone treating particulate slurry is a consequence of the swirling flow that produces a centrifugal force on the fluid and suspended particles. In spite of hydrocyclone have many advantage, the application for treatment of urban stormwater case study were rare. We conducted a laboratory scale study on treatable potential of micro particles using hydrocyclone filter (HCF) that was a combined modified hydrocyclone with perlite filter cartridge. Since it was not easy to use actual storm water in the scaled-down hydraulic model investigations, it was necessary to reproduce ranges of particles sizes with synthetic materials. The synthesized storm runoff was made with water and addition of particles; ion exchange resin, road sediment, commercial area manhole sediment, and silica gel particles. Experimental studies have been carried out about the particle separation performance of HCF-open system and HCF-closed system. The principal structural differences of these HCFs are underflow zone structure and vortex finder. HCF was made of acryl resin with 120 mm of diameter hydrocyclone and 250 mm of diameter filter chamber and overall height of 800 mm. To determine the removal efficiency for various influent concentrations of suspended solids (SS) and chemical oxygen demand (COD), tests were performed with different operational conditions. The operated maximum of surface loading rate was about 700 $m^3/m^2$/day for HCF-open system, and 1,200 $m^3/m^2$/day for HCF-closed system. It was found that particle removal efficiency for the HCF-closed system is better than the HCF-open system under same surface loading rate. Results showed that SS removal efficiency with the HCF-closed system improved by about 8~20% compared with HCF-open system. The average removal efficiency difference for HCF-closed system between measurement and CFD particle tracking simulation was about 4%.

Production of Alternative Coagulant Using Waste Activated Alumina and Evaluation of Coagulation Activity (폐촉매 부산물로부터 대체 응집제 제조 및 응집성능 평가)

  • Lee, Sangwon;Moon, Taesup;Kim, Hyosoo;Choi, Myungwon;Lee, Deasun;Park, Sangtae;Kim, Changwon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.7
    • /
    • pp.514-520
    • /
    • 2014
  • In this study, the production potential of alternative coagulant ($Al_2(SO_4)_3$ solution) having the identical coagulation activity with respect to the commercial coagulant was investigated. The raw material of alternative coagulant was a spent catalyst including aluminium (waste activated alumina) generated in the manufacturing process of the polymer. The alternative coagulant was produced through a series of processes: 1) intense heat and grinding, 2) chemical polymerization and substitution with $H_2SO_4$ solution, 3) dissolution and dilution and 4) settling and separation. To determine the optimal operating conditions in the lab-scale autoclave and dissolver, the content of $Al_2O_3$ in alternative coagulant was analyzed according to changes of the purity of sulfuric acid, reaction temperature, injection ratio of sulfuric acid and water in the dissolver. The results showed that the alternative coagulant having the $Al_2O_3$ content of 7~8% was produced under the optimal conditions such as $H_2SO_4$ purity of 50%, reaction temperature of $120^{\circ}C$, injection ratio of $H_2SO_4$ of 5 times and injection ratio of water of 2.3 times in dissolver. In order to evaluate the coagulation activity of the alternative coagulant, the Jar-test was conducted to the effluent in aerobic reactor. As a result, in both cases of Al/P mole of 1.5 and 2.0, the coagulation activity of the alternative coagulant was higher than that of the existing commercial coagulant. When the production costs were compared between the alternative and commercial coagulant through economic analysis, the production cost reduction of about 50% was available in the case of the alternative coagulant. In addition, it was identified that the alternative coagulant could be applied at field wastewater treatment plant without environmental problem through ecological toxicity testing.

Ultrastructure of nasal cilia in children with recurrent or persistent respiratory diseases (반복 지속성 호흡기 질환 소아에서 비강 섬모의 미세구조 검사의 의의)

  • Shin, Su-A;Yang, Seung;Oh, Jae-Won;Lee, Ha-Baik;Park, Cheol-Eon;Kwan, Jung-Kyun
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.4
    • /
    • pp.410-416
    • /
    • 2006
  • Purpose : Ciliary abnormalities of the respiratory system usually accompany recurrent or persistent respiratory diseases such as paranasal sinusitis, bronchiectasis, rhinitis, and/or otitis media, since they cause certain derangements in ciliary cleaning activities. This disease is usually inherited by autosomal recessive trait, but may also be found to be acquired or transient in rare cases after heavy exposure to pollutants, cigarette smoking or severe infection. We performed this study in children with frequently recurrent or persistent respiratory diseases to clarify if the ciliary abnormalities are preceding factors. Methods : We enrolled 17 children with suspected respiratory ciliary abnormalities. The indications for evaluation of ciliary ultrastructure were recurrent or persistent respiratory infections. Children with immunologic abnormalities were excluded. From August 2000 to July 2003, we performed a biopsy on nasal mucosa and examined the structure of ciliary status by using an electron microscope. Results : Of the subjects, there were seven males and 10 females, aged 2 to 10 years. Out of the 17 subjects, 12 cases of chronic paranasal sinusitis, nine chronic coughs, nine frequent upper respiratory infections, seven cases of recurrent otitis media, four cases of recurrent pneumonia, and four cases of bronchial asthma were found. Out of the 17 cases on which histologic examinations were conducted, four cases showed pathologic findings, including one case of inner dynein arm defect, one of microtubular transposition, one of supernumerous tubules, and one singlet, respectively. Conclusion : It is essential for differential diagnosis and effective treatment to identify the abnormalities of ultrastructure of nasal cilia in children with symptoms of frequently recurrent or persistent respiratory diseases, if immunodeficiency or respiratory allergy could be excluded.

The Study on Physical Properties and Applicability of Material of Polyamide-66/Glass Fiber Blends Composition to the Eyewear Frame (Polyamide-66/Glass fiber 블렌드 조성물의 물리적 특성 및 안경테 소재로써의 적용성에 관한 연구)

  • Son, Jin-Young;Lee, Ji-Eun;Choi, Kyung-Man;Bae, Yu-Hwan;Kim, Ki-Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.365-371
    • /
    • 2013
  • Purpose: In this study, we evaluated the physical and thermal properties of the compositions made by blending glass fiber (GF) of different contents into glass fiber polyamide-66, and investigated if the compositions applying to the glasses frame to replace the TR-90, which is polyamide-12 resin used as an injection-type spectacle frame material. Methods: To investigate the characteristics change of polyamide-66 (PA-66) compositions with the change of the content of glass fibers, we produced a composition of the content by using a twin-screw extruder. The mechanical strength of the composition production was measured and coating properties as well as cutting processability were evaluated. We evaluated the applicability of the glasses frame by comparison the results of new compositions with characterizations of traditional TR. Results: For the results of the characterization of Polyamide-66/GF composition, we found that the higher increase of content of the glass fiber, the less mold shrinkage rate, and the mechanical strength was increased. Tensile strength increased from $498kg/cm^2$ for 0 wt% of the content of the glass fibers to $849kg/cm^2$ for 30 wt% of the content of the glass fibers. As a result of a coating evaluation, the strength of coating was 4B in the GF 5wt% and 5B, which was extremely good coating characteristics, in the over than GF 5 wt%. Conclusions: In case that 30 wt% of the glass fiber was blended, the mechanical strength was greatly improved, the hardness was increased, injection temperature increased due to increase of the viscosity, and the flow mark of the product may occur. The paint coating of PA-66 blended with glass fiber was all excellent. With general evaluating physical properties and workability properties it was determined that around 10 wt% of the content of the glass fibers was possible to apply a spectacle frame.

Proficiency Testing for the Gas-chromatographic Analysis of Procymidone, Chlorpyrifos and Metolachlor Residues in Soil (가스크로마토그래피를 이용한 토양 중 프로사이미돈과 클로르피리포스, 메톨라클로르의 잔류분석 숙련도시험)

  • Kim, Chan-Sub;Son, Kyeong-Ae;Gil, Geun-Hwan;Kim, Jin-Bae;Hong, Su-Myeong;Kwon, Hye-Young
    • The Korean Journal of Pesticide Science
    • /
    • v.17 no.2
    • /
    • pp.94-106
    • /
    • 2013
  • The proficiency testing for the residue laboratories of pesticide registration was conducted in order to improve the reliability and the ability for pesticide residue analysis. On October 2011 the testing was carried out using the soil collected and kept as the moistened state for five years, which is expected to very low residue levels of pesticides. The soil was fortified with chlorpyrifos, metolachlor and procymidone in a manner similar to prepare soil sample for indoor soil degradation test, and then sub-samples were prepared for the distribution to participants. Some of them were randomly selected for confirm of homogeneity and to ensure the stability of samples at room temperature. Samples were consisted of two soil treated as different levels, one of which was used to the assesment and another used to confirm. In addition, provide three standard solutions, respectively concentration of 10 mg/L, and untreated soil. Forty seven institutions submitted results. The medians of results were used as the assigned values for pesticide residues. Fitness for purpose standard deviation of proficiency test was calculated by applying 20% RSD as the coefficient of variation allowed in the soil residue test. Z-score was applied for evaluation of individual pesticides, and the average of the absolute value of the Z-score for the overall assessment of pesticides. Laboratories evaluated the absolute value of the Z-score less than 2 to fit the case of chlorpyrifos and procymidone were 44, metolachlor 40.

Evaluation of the accuracy of the HexaPOD evo RT system using Non-coplanar beams in lung cancer (폐암환자의 비동일평면 선속 빔 치료 시 HexaPOD evo RT system 의 정확성 평가)

  • Jang, Sewuk;cho, Kangchul;Lee, Sangkyoo;Kim, Jooho;Cho, Jeonghee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.115-122
    • /
    • 2015
  • Purpose : The aim of this study, evaluate the accuracy of HeaxPOD evo RT system using the non-coplanar beam. Materials and Methods : 13 treatment plans are used which applied non-coplanar beams and 10 treatment plans which coplanar beams are used. the correction value what adjust to 6D couch is determined by each patient's setup errors only rotation direction. The study executed followings. first, Applying the correction value, measure the point dose and calculate the ${\gamma}$-index(${\gamma}=3%$ / 3 mm, ${\gamma}=2%$ / 2 mm). second, acquire data as previous methods without correction by HexaPOD. Results : For comparing the two results, we find out the more precise applying HexaPOD by point dose 0.2% in coplanar and non-coplanar. in the case of ${\gamma}$-index<1(${\gamma}=3%$ / 3 mm), more precise 2.2% in coplanar and 7% in Non-coplanar. Particularly, ${\gamma}$-index<1(2% / 2 mm) show the difference 9.2% in coplanar and 15.1% non-coplanar between apply HexaPOD and dose not apply HexaPOD. Conclusion : Using the HexaPOD is more precise than without HexaPOD. It suggests that HexaPOD evo RT system is very useful for precise and high dose delivery.

  • PDF

Evaluation of the Breast plan using the TLD and Mosfet for the skin dose (열형광선량계(TLD)와 MOSFET을 이용한 유방암 방사선치료계획에 대한 피부선량 평가)

  • Kim, seon myeong;Kim, young bum;Bak, sang yun;Lee, sang rok;Jeong, se young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.107-113
    • /
    • 2015
  • Purpose : The measurement of skin dose is very important that treatment of breast cancer. On account of the cold or hot dose as compared with prescription dose, it is necessary to analyse the skin dose occurring during the various plan of the breast cancer treatment. At our hospital, we want to apply various analyses using a diversity of dosimeters to the breast cancer treatment. Subjectss and Methods : In the study, the anthropomorphic phantom is used to find out the dose difference of the skin(draining site), scar and others occurring from the tangential treatment plan of breast cancer. We took computed tomography scan of the anthropomorphic phantom and made plans for the treatment planing using open and wedge, Field-in-Field, Dose fluence. Using these, we made a comparative analysis of the dose date points by using the Eclipse. For the dose comparison, we place the anthropomorphic phantom in the treatment room and compared the measurement results by using the TLD and MOSFET on the dose data points. Results : On the central point of treatment planing basis, the upward and downward skin dose measured by the MOSFET was the highest when the fluence was used. The skin dose of inner and outer was distinguished from the figure(5.7% ~ 10.3%) when the measurements were fulfilled by using TLD and MOSFET. The other side of breast dose was the lowest in the open beam, on the other hand, is highest in the Dose fluence plan. In the different kinds of treatment, the dose deviation of inner and outer was the highest, and so this was the same with the TLD and MOSFET measurement case. The outer deviation was highest in the TLD, and the Inner'was highest in the MOSFET. Conclusion : Skin dose in relation to the treatment plan was the highest in the planing using the fluence technique in general and it was supposed that the high dose had been caused by the movement of the MLC. There's some differences among the all the treatment planning, but the sites such as IM node occurring the lack of dose, scar, drain site are needed pay close attention. Using the treatment planning of dose fluence is good to compensate the lack of dose, but It increases the dose of the selective range rather than the overall dose. Therefore, choosing the radiotherapy technique is desirable in the lights of the age and performance of the patient.

  • PDF

Feasibility of MatriXX for Intensity Modulated Radiation Therapy Quality Assurance (세기변조방사선치료의 품질관리를 위한 이온전리함 매트릭스의 유용성 고찰)

  • Kang, Min-Young;Kim, Yoen-Lae;Park, Byung-Moon;Bae, Yong-Ki;Bang, Dong-Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.91-97
    • /
    • 2007
  • Purpose: To evaluate the feasibility of a commercial ion chamber array for intensity modulated radiation therapy (IMRT) quality assurance (QA) was performed IMRT patient-specific QA Materials and Methods: A use of IMRT patient-specific QA was examined for nasopharyngeal patient by using 6MV photon beams. The MatriXX (Wellhofer Dosimetrie, Germany) was used for IMRT QA. The case of nasopharyngeal cancer was performed inverse treatment planning. A hybrid dose distribution made on the CT data of MatriXX and solid phantom all of the same gantry angle (0$^\circ$). The measurement was acquired with geometrical condition that equal to hybrid treatment planning. The $\gamma$-index (dose difference 3%, DTA 3 mm) histogram was used for quantitative analysis of dose discrepancies. An absolute dose was compared at the high dose low gradient region. Results: The dose distribution was shown a good agreement by gamma evaluation. A proportion of acceptance criteria was 95.8%, 97.52%, 96.28%, 98.20%, 97.78%, 96.64% and 92.70% for gantry angles were 0$^\circ$, 55$^\circ$, 110$^\circ$, 140$^\circ$, 220$^\circ$, 250$^\circ$ and 305$^\circ$, respectively. The absolute dose in high dose low gradient region was shown reasonable agreement with the RTP calculation within $\pm$3%. Conclusion: The MatriXX offers the dosimetric characteristics required for performing both relative and absolute measurements. If MatriXX use in the clinic, it could be simplified and reduced the IMRT patient-specific QA workload. Therefore, the MatriXX is evaluated as a reliable and convenient dosimeter for IMRT patient-specific QA.

  • PDF

Analysis of bone bruise associated with anterior cruciate ligament injury (전방십자인대 손상과 관련된 골멍의 패턴 분석)

  • Jung, Dae-Won;Kim, Chang-Wan;Baik, Jong-Min;Seo, Seung-Suk
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.11 no.1
    • /
    • pp.44-50
    • /
    • 2012
  • Purpose: The purpose of this study is to analyze the relationship between acute anterior cruciate ligament (ACL) injury and bone bruise using the survey for location and incidence of bone bruise. Materials and Methods: From Jan. 2006 to Feb. 2010, 87 knees from who had complaint a traumatic knee pain were diagnosed as acute ACL tear using MRI evaluation. Associated injury, location and incidence of bone bruise were analyzed using MRI. The location of bone bruise on the MRI was classified as medial, central and lateral area on anteroposterior and lateral view of femur and tibia. The bone bruise was classified with Costa Paz classification. Results: Bone bruise of injury during daily living activity were located at medial area on coronary view and anterior area on sagittal view of distal femur, at medial area on coronary view and anterior area on sagittal view of proximal tibia (p=0.024, p=0.021, p=0.025 and p=0.029, respectively). Bone bruise of injury during sports activity were located at lateral area on coronary view and central area on sagittal view of distal femur, at lateral area on coronary view and posterior area on sagittal view of proximal tibia (p=0.014, p=0.015, p=0.018 and p=0.017, respectively). Bone bruise patterns due to traffic accident were inconclusive (p=0.264, p=0.254, p=0.229 and p=0.267, respectively). Conclusion: Injury mechanism of acute ACL injury from activities of daily living or sports activities compared to that of traffic accident showed a more consistent bone bruise patterns. Special attention to acute ACL tear must be paid in case of bone bruise at lateral tibial plateau and lateral femoral condyle.

  • PDF

A study on transferring the effects of brand reputation and level of service satisfaction of an offline channel company when it is expanding to an online distribution channel (온라인 유통채널 확장시 오프라인 채널의 브랜드 명성, 서비스 만족도의 이전 효과에 관한 연구)

  • Hwang, Hee-Joong;Lee, Sun-Mi
    • Journal of Distribution Science
    • /
    • v.9 no.2
    • /
    • pp.31-36
    • /
    • 2011
  • I conducted empirical analyses of what happens when an offline channel expands to an online channel and whether the pre-existing offline channel's competitive assets (e.g. brand reputation and level of service satisfaction) can be linked to online channel preference. I found that an offline channel's brand reputation and level of service satisfaction can have a direct influence on offline channel preference and a second-hand influence on online channel preference. Thus, if the competitiveness of the online channel is strong enough and its customers have a higher preference for the offline channel, they will be committed and loyal to the company. The resultant enhanced competitiveness of the offline channel will present opportunities for both present and future success. The main results are the following. First, the management of the distribution channel service quality is more important than that of the brand reputation. Customers' experiences of service and subjective evaluations are not important only as the leading factors in the long-term brand reputation management but also as influential factors in channel preference. SoThus, given that the service quality of the pre-existing channel is not the customers' main concern, a strategy of improving the level of service satisfaction aimed at present customers is more valuable than a wide brand positioning strategy aimed at general and new customers. Second, when an offline channel company establishes an internet shopping mall on an online channel, it is highly likely that the preference and subjective evaluation of the present customers will influence the online channel. This applies not only to the special case of an expansion from an offline intermediary channel to an online one, but also to an online channel acting as an expansion of the business model of a conventional manufacturing or service company: both cases are vertical integrations of marketing channels in an expansion of the distribution channel. My theory applies to a wide range of contexts. Third and finally, any business strategy can grasp the meaning of 'channel expansion. Fundamentally, it is an expansion of the sales activity channel and marketing activity. However, it is also a way of enhancing marketing and sales competitiveness through an expansion to an online or offline channel. The expansion of an offline company to an online channel could be seen not as improvement but as an innovation of the business process by which two goals are achieved with one technique. The former is expected to increase the sales of the offline company, and the latter is also expected to increase sales while also contributing to cost reduction.

  • PDF