• Title/Summary/Keyword: estimation of difference

Search Result 2,061, Processing Time 0.029 seconds

Estimation of Diagnostic Range for Measurement Tools, while BMD Testing to Health Examination in Transitional Ages (생애전환기 건강진단 골밀도 검사시 측정도구에 따른 진단범위의 유효성 평가)

  • Kim, Nam-Soo;Jung, Kyung-Sick;Kang, Eun-Jung;Oh, Jung-Eun;Lee, Byung-Kook
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.10
    • /
    • pp.385-394
    • /
    • 2012
  • The aim of this study was to determine the effectiveness of diagnostic range for BMD measurement tools(DEXA, QUS, and RA) to health examination in transitional ages. In standard T-score -2.5 of DEXA, cutoff value by RA is -1.675(sensitivity: 70.0%, specificity: 63.7%) and cutoff value by QUS is -1.733(sensitivity: 70.4, specificity: 59.5%), also T-score -3.0 of DEXA, cutoff value by RA is -2.325(sensitivity: 70.0%, specificity: 42.9%) and cutoff value by QUS is -2.323(sensitivity: 70.4, specificity: 56.8%). There was, however, no significant difference in standard DEXA(lumbar spine and femur) between RA and QUS by repeat measurement(precision), and correlation were without effect. ROC analysis showed that all methods are qualified for BMD measurement tools to health examination in transitional ages; however, the different sensitivities and specificities of the methods, as well as age and gender, calibration parameters for diagnostic tests have to be considered.

A Study of the Urban Tree Canopy Mean Radiant Temperature Mitigation Estimation (도시림의 여름철 평균복사온도 저감 추정 연구)

  • An, Seung Man;Son, Hak-gi;Lee, Kyoo-Seock;Yi, Chaeyeon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.1
    • /
    • pp.93-106
    • /
    • 2016
  • This study aimed to estimate and evaluate the thermal mitigation of the urban tree canopy on the summer outdoor environment by quantitative use of mean radiant temperature. This study applied the SOLWEIG model based $T_{mrt}$ comparison method by using both (1) urban tree canopy presence examples and (2) urban tree canopy absence examples as constructed from airborne LiDAR system based three-dimensional point cloud data. As a result, it was found that an urban tree canopy can provide a decrease in the entire domain averaged daily mean $T_{mrt}$ about $5^{\circ}C$ and that the difference can increase up to $33^{\circ}C$ depending both on sun position and site conditions. These results will enhance urban microclimate studies such as indices (e.g., wind speed, humidity, air temperature) and biometeorology (e.g., perceived temperature) and will be used to support forest based public green policy development.

Rainfall Characteristics in the Tropical Oceans: Observations using TRMM TMI and PR (열대강우관측(TRMM) 위성의 TMI와 PR에서 관측된 열대해양에서의 강우 특성)

  • Seo, Eun-Kyoung
    • Journal of the Korean earth science society
    • /
    • v.33 no.2
    • /
    • pp.113-125
    • /
    • 2012
  • The estimations of the surface rain intensity and rain-related physical variables derived from two independent Tropical Rainfall Measuring Mission (TRMM) satellite sensors, TRMM Microwave Imager (TMI) and Precipitation Radar (PR), were compared over four different oceans. The precipitating clouds developed most frequently in the warmest sea surface temperature (SST) region of the west Pacific, which is 1.5 times more frequent than in the east Pacific and the tropical Atlantic oceans. However, the east Pacific exhibited the most intense rain intensity for the convective and mixed rain types while the tropical Atlantic showed the most intense rain intensity for all TMI rainy pixels. It was found that the deviation of TMI-derived rain rate yielded a big difference in region-to-region and rain type-to-type if the PR rain intensity value is assumed to be closer to the truth. Furthermore, the deviation by rain types showed opposite signs between convective and non-convective rain types. It was found that the region-to-region deviation differences reached more than 200% even though the selected tropical oceans have relatively similar geophysical environments. Therefore, the validation for the microwave rain estimation needs to be performed according to both rain types and climate regimes, and it also requires more sophisticated TMI algorithm which reflects the locality of rainfall characteristics.

Typical Seismic Intensity Calculation for Each Region Using Site Response Analysis (부지응답해석을 이용한 지역별 대표 진도 산출 연구)

  • Ahn, Jae-Kwang;Son, Su-Won
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.1
    • /
    • pp.5-12
    • /
    • 2020
  • Vibration propagated from seismic sources has damping according to distance and amplification and reduction characteristic in different regions according to topography and geological structure. The vibration propagated from the seismic source to the bedrock is largely affected by the damping according to the separation distance, which can be simply estimated through the damping equation. However, it is important to grasp geological information by location because vibration estimation transmitted to the surface are affected by the natural period of the soil located above the bedrock. Geotechnical investigation data are needed to estimate the seismic intensity based on geological information. If there is no Vs profile, the standard penetration tests are mainly used to determine the soil parameters. The Integrated DB Center of National Geotechnical Information manages the geotechnical survey data performed on the domestic ground, and there is the standard penetration test information of 400,000 holes. In this study, the possibility of quantitation the amplification coefficient for each region was examined to calculated the physical interactive seismic intensity based on geotechnical information. At this time, the shear wave column diagram was generated from the SPT-N value and ground response analysis was performed in the target area. The site coefficients for each zone and the seismic intensity distribution for the seismic motion present a significant difference according to the analysis method and the regional setting.

Effect of the Multisensory on the Stress-relieving for Vehicle Driver (운전자 스트레스 저감을 위한 다감각 자극의 효과)

  • Kim, Young-Joo;Kim, Hyejin;Lee, Hyunwoo;Jo, Youngho;Whang, Mincheol
    • Science of Emotion and Sensibility
    • /
    • v.24 no.4
    • /
    • pp.107-116
    • /
    • 2021
  • This study aims to investigate the effect of multisensory stimulation on relieving the stress experienced by drivers. The photoplethysmograms (PPGs) of 30 healthy subjects were measured, and their subjective response to stressful situations and normal driving were evaluated. The subjects underwent nonstimulation and multisensory stimulation in stressful driving situations. Heart rate estimation from the PPG was collected via an ear-type sensor to reduce movement noise. The signals acquired were sampled at 200 Hz using BIOPAC PPG100C. Heart rate variability (HRV) was analyzed to compare the effect of multisensory stimulation on stress situations. In the multisensory stimulation, blue, green, and yellow were used for the visual sensory system; white, pink, and brown noises were used for the auditory sensory system; and lavender, lemon, and rosemary were used for the olfactory sensory system. No difference was observed in the subjective evaluation; however, the HRV results showed an increased HF (%) and decreased LF (%) and LF/HF (%) in the multisensory stimulation (e.g., green, pink noise, and rosemary) when compared to the nonstimulation.

An Enhanced Frequency Synchronization Algorithm for 3GPP LTE FDD/TDD Dual Mode Downlink Receiver (3GPP LTE FDD/TDD 듀얼 모드 하향 링크 수신기를 위한 개선된 주파수 동기 알고리즘)

  • Shim, Myung-Jun;Jang, Jun-Hee;Choi, Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.1C
    • /
    • pp.103-112
    • /
    • 2010
  • In this paper, we propose a coarse and fine frequency synchronization method which is suitable for the 3GPP(3rd Generation Partnership Project) LTE(Long Term Evolution) FDD(Frequency Division Duplexing) / TDD(Time Division Duplexing) dual mode system. In general, PSS(Primary Synchronization Signal) correlation based estimation method and CP(Cyclic Prefix) correlation based tracking loop are applied for coarse and fine frequency synchronization in 3GPP LTE OFDMA(Orthogonal Frequency Division Multiple Access) system, respectively. However, the conventional coarse frequency synchronization method has performance degradation caused by fading channel and squaring loss. Also, the conventional fine frequency synchronization method cannot guarantee stable operation in TDD mode because of signal power difference between uplink and downlink subframe. Therefore, in this paper, we propose enhanced coarse and fine frequency synchronization methods which can estimate more accurately in multi-path fading channel and high speed channel environments and has stable operation for TDD frame structure, respectively. By computer simulation, we show that the proposed methods outperform the conventional methods, and verify that the proposed frequency synchronization method can guarantee stable operation in 3GPP LTE FDD/TDD dual mode downlink receiver.

Assessment of Water Control Model for Tomato and Paprika in the Greenhouse Using the Penman-Monteith Model (Penman-Monteith을 이용한 토마토와 파프리카의 증발산 모델 평가)

  • Somnuek, Siriluk;Hong, Youngsin;Kim, Minyoung;Lee, Sanggyu;Baek, Jeonghyun;Kwak, Kangsu;Lee, Hyondong;Lee, Jaesu
    • Journal of Bio-Environment Control
    • /
    • v.29 no.3
    • /
    • pp.209-218
    • /
    • 2020
  • This paper investigated actual crop evapotranspiration (ETc) of tomato and paprika planted in test beds of the greenhouse. Crop water requirement (CWR) is the amount of water required to compensate ETc loss from the crop. The main objectives of the study are to assess whether the actual crop watering (ACW) was adequate CWR of tomato and paprika and which amount of ACW should be irrigated to each crop. ETc was estimated using the Penman-Monteith model (P-M) for each crop. ACW was calculated from the difference of amount of nutrient supply water and amount of nutrient drainage water. ACW and CWR of each crop were determined, compared and assessed. Results indicated CWR-tomato was around 100 to 1,200 ml/day, while CWR-paprika ranged from 100 to 500 ml/day. Comparison of ACW and CWR of each crop found that the difference of ACW and CWR are fluctuated following day of planting (DAP). However, the differences could divide into two phases, first the amount of ACWs of each crop are less than CWR in the initial phase (60 DAP) around 500 ml/day and 91 ml/day, respectively. Then, ACWs of each crop are greater than the CWR after 60 DAP until the end of cultivation approximately 400 ml/day in tomato and 178 ml/day in paprika. ETc assessment is necessary to correctly quantify crop irrigation water needs and it is an accurate short-term estimation of CWR in greenhouse for optimal irrigation scheduling. Thus, reducing ACW of tomato and paprika in the greenhouse is a recommendation. The amount of ACW of tomato should be applied from 100 to 1,200 ml/day and paprika is 100 to 500 ml/day depend on DAP.

Estimation of Physico-Chemical Characteristics of Domestic Aroma Rice and Foreign Aroma Rice (국내 육성 및 도입 향미자원의 이화학적 특성 평가)

  • Kim, Jeong-Soon;Ahn, Sang-Nag;Kang, Hee-Kyoung;Cho, Yang-Hee;Gwag, Jae-Gyun;Lee, Sok-Young
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.2
    • /
    • pp.203-216
    • /
    • 2008
  • This study was conducted to provide the fundamental data based on the analysis of phsyco-chemical characteristics of domestic aroma rice and foreign aroma rice for breeding of aroma rice. The average amylose content of domestic aroma rice and widely cultured domestic traditional rice were 18.1% and 19.0% respectively. The Indica and the Japonica types were 25.6% and 25.0%. In the domestic rice of Tongil and Japonica type, the average protein content were 7.6% and 6.4% respectively. And the average protein content of foreign Indica and Japonica type were 7.6% and 7.0% respectively. And the average protein content of widely cultured domestic traditional rice was 5.6%. The Japonica type of rice shown a low protein content compared with Indica type of rice, and the foreign Indica types of rice exhibited a wide range of protein contents. The average alkali digestive value (ADV) of Tongil type of the domestic aroma rice was about 5.0 and the value of Japonica type was about 6.0. The average ADV of foreign Indica and Japonica type were 4.3 and 5.1 respectively. Also the average ADV of widely cultured domestic aroma rice was about 6.0. The foreign aroma rice were distributed a variable range of ADV value and lower than the both domestic aroma rice and widely cultivated domestic rice. In the whole aspect of the amylogram, the highest viscosity, the lowest viscosity and the last viscosity of the total resources, in domestic aroma rice were clearly lower with the next order, Japonica type of foreign aroma rice, Indica type of foreign aroma rice, Japonica type of domestic aroma rice, widely cultured domestic traditional rice, and Tongil type of domestic aroma rice. It shown the difference aspect of amylograms according to the eco-type of the domestic and foreign aroma and the general rice, and it was distinguishable in difference of the aspect of the amylogram of the endosperm of rice as non-glutinous rice, waxy rice, and middle-waxy rice.

Detection of Wildfire Burned Areas in California Using Deep Learning and Landsat 8 Images (딥러닝과 Landsat 8 영상을 이용한 캘리포니아 산불 피해지 탐지)

  • Youngmin Seo;Youjeong Youn;Seoyeon Kim;Jonggu Kang;Yemin Jeong;Soyeon Choi;Yungyo Im;Yangwon Lee
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1413-1425
    • /
    • 2023
  • The increasing frequency of wildfires due to climate change is causing extreme loss of life and property. They cause loss of vegetation and affect ecosystem changes depending on their intensity and occurrence. Ecosystem changes, in turn, affect wildfire occurrence, causing secondary damage. Thus, accurate estimation of the areas affected by wildfires is fundamental. Satellite remote sensing is used for forest fire detection because it can rapidly acquire topographic and meteorological information about the affected area after forest fires. In addition, deep learning algorithms such as convolutional neural networks (CNN) and transformer models show high performance for more accurate monitoring of fire-burnt regions. To date, the application of deep learning models has been limited, and there is a scarcity of reports providing quantitative performance evaluations for practical field utilization. Hence, this study emphasizes a comparative analysis, exploring performance enhancements achieved through both model selection and data design. This study examined deep learning models for detecting wildfire-damaged areas using Landsat 8 satellite images in California. Also, we conducted a comprehensive comparison and analysis of the detection performance of multiple models, such as U-Net and High-Resolution Network-Object Contextual Representation (HRNet-OCR). Wildfire-related spectral indices such as normalized difference vegetation index (NDVI) and normalized burn ratio (NBR) were used as input channels for the deep learning models to reflect the degree of vegetation cover and surface moisture content. As a result, the mean intersection over union (mIoU) was 0.831 for U-Net and 0.848 for HRNet-OCR, showing high segmentation performance. The inclusion of spectral indices alongside the base wavelength bands resulted in increased metric values for all combinations, affirming that the augmentation of input data with spectral indices contributes to the refinement of pixels. This study can be applied to other satellite images to build a recovery strategy for fire-burnt areas.

Study on the Heat Transfer Phenomenon around Underground Concrete Digesters for Bigas Production Systems (생물개스 발생시스템을 위한 지하매설콘크리트 다이제스터의 열전달에 관한 연구)

  • 김윤기;고재균
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.22 no.1
    • /
    • pp.53-66
    • /
    • 1980
  • The research work is concerned with the analytical and experimental studies on the heat transfer phenomenon around the underground concrete digester used for biogas production Systems. A mathematical and computational method was developed to estimate heat losses from underground cylindrical concrete digester used for biogas production systems. To test its feasibility and to evaluate thermal parameters of materials related, the method was applied to six physical model digesters. The cylindrical concrete digester was taken as a physical model, to which the model,atical model of heat balance can be applied. The mathematical model was transformed by means of finite element method and used to analyze temperature distribution with respect to several boundary conditions and design parameters. The design parameters of experimental digesters were selected as; three different sizes 40cm by 80cm, 80cm by 160cm and l00cm by 200cm in diameter and height; two different levels of insulation materials-plain concrete and vermiculite mixing in concrete; and two different types of installation-underground and half-exposed. In order to carry out a particular aim of this study, the liquid within the digester was substituted by water, and its temperature was controlled in five levels-35。 C, 30。 C, 25。 C, 20。C and 15。C; and the ambient air temperature and ground temperature were checked out of the system under natural winter climate conditions. The following results were drawn from the study. 1.The analytical method, by which the estimated values of temperature distribution around a cylindrical digester were obtained, was able to be generally accepted from the comparison of the estimated values with the measured. However, the difference between the estimated and measured temperature had a trend to be considerably increased when the ambient temperature was relatively low. This was mainly related variations of input parameters including the thermal conductivity of soil, applied to the numerical analysis. Consequently, the improvement of these input data for the simulated operation of the numerical analysis is expected as an approach to obtain better refined estimation. 2.The difference between estimated and measured heat losses was shown to have the similar trend to that of temperature distribution discussed above. 3.It was found that a map of isothermal lines drawn from the estimated temperature distribution was very useful for a general observation of the direction and rate of heat transfer within the boundary. From this analysis, it was interpreted that most of heat losses is passed through the triangular section bounded within 45 degrees toward the wall at the bottom edge of the digesten Therefore, any effective insulation should be considered within this region. 4.It was verified by experiment that heat loss per unit volume of liquid was reduced as the size of the digester became larger For instance, at the liquid temperature of 35˚ C, the heat loss per unit volume from the 0. 1m$^3$ digester was 1, 050 Kcal/hr m$^3$, while at for 1. 57m$^3$ digester was 150 Kcal/hr m$^3$. 5.In the light of insulation, the vermiculite concrete was consistently shown to be superior to the plain concrete. At the liquid temperature ranging from 15。 C to 350 C, the reduction of heat loss was ranged from 5% to 25% for the half-exposed digester, while from 10% to 28% for the fully underground digester. 6.In the comparison of heat loss between the half-exposed and underground digesters, the heat loss from the former was fr6m 1,6 to 2, 6 times as much as that from the latter. This leads to the evidence that the underground digester takes advantage of heat conservation during winter.

  • PDF