• Title/Summary/Keyword: esthetic analysis

Search Result 310, Processing Time 0.02 seconds

Analysis of the Traditional Setting-up as an Application for Spatial Composition

  • NamGoong, Sun;Lee, Yu-Ri
    • Journal of the Korea Furniture Society
    • /
    • v.21 no.3
    • /
    • pp.216-228
    • /
    • 2010
  • Recently, there is a new issue, among the contemporary people, for new life style, such as green design and well being. This trend brought up the necessity that there should be alternatives for interior spatial design. In order to catch up with these new issues, the new convenient and environment friendly methods are in need. Space composition using setting-up is skill that can express both the structural aspect and esthetic because it represents traditional beauty into the contemporary age through the structural rigidity and formal beauty. Also the lumber, as main materials for setting up, is in line with well being life style and environment friendliness. The construction of structure by setting-up has advantages in terms of the reuse and the convenience in that the construction of structure is adjustable according to environment. And setting-up has enough plasticity not only because of its own role as linking the objects but also because of being framed by itself. Therefore setting-up will be a design element, if it is expressed outward. Thus, this study aims to give a guide line about how to apply the result from the evaluating that "what is the most suitable setting-up" and "what is the most suitable detail setting-up", based on that structural rigidity, decorativeness and the ease of works. As a result of evaluation, the most excellent types of setting-up in terms of structural rigidity are "Jangbu" and "Panjae" and "Yeongui". The most excellent types of setting-up in terms of decorativeness are "Panjae" and "Yeongui", and the most excellent type of the ease of work is "Mat". And also the most applicable detail setting-up for the utilization of spatial composition is proposed.

  • PDF

A STUDY ON THE SHEAR BOND STRENGTH OF RESIN CEMENTS (수종 레진시멘트의 전단결합강도에 관한 연구)

  • Yang, Mi-Young;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.132-143
    • /
    • 1997
  • Recently composite resin luting cement have been widely used according as esthetic requirement was increased. The purpose of this study was to evaluate of shear bond strength of four resin cements to bovine dentin. The materials used in this study were All-Bond 2(dentin bonding agent), Duolink cement, Bistite resin cement, Twinlook cement, Clearfil CR inlay cement. A total 40 acrylic cylinders with bovine dentin were divided into four groups. Four experimental groups were as follows; Group l(AB) : Specimens bonded with All-Bond 2 and Duolink Cement Group 2(BT) : Specimens bonded with Bistite Resin Cement Group 3(TL) : Specimens bonded with Twinlook Cement Group 4(CR) : Specimens bonded with Clearfil CR Inlay Cement Mter 1 hour of bonding, all specimens were stored for 24 hours in water at $37^{\circ}C$ and tested with Instron universal testing machine between bovine dentin and resin cements. The data were evaluated statistically at the 95% confidence level with a one-way analysis of variance and Tukey's range statistics. The following results obtained; 1. The group l(AB) was highest shear bond strength and the group 3(TL) was 10west(p>0.05). 2. Group 2(BT), 4(CR) were similar shear bond strength and there was no significant difference(p<0.05). 3. Group 1(AB), 4(CR) with acid etching were showed resin tags on the opened dentinal tubules, but Group 2(BT), 3(TL) without acid etching were not showed resin tags. 4. Group l(AB) was showed intimate adaptation than other groups.

  • PDF

CHANGES IN GONIAL ANGLE AND MANDIBULAR WIDTH AFTER ORTHOGNATHIC SURGERY IN MANDIBULAR PROGNATHIC PATIENTS (하악전돌증 환자에서 악교정수술 후 하악각 및 하악폭경의 변화)

  • Kim, In-Ho;Han, Chang-Hun;Ryu, Sun-Youl
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.2
    • /
    • pp.129-137
    • /
    • 2006
  • The treatment plan for orthognathic surgery must be based on accurate predictions, and this can be produced the most esthetic, functional and stable results. The purpose of this study was aimed to evaluate the amount and interrelationship of the gonial angle and the mandibular width change after the mandibular setback surgery in the mandibular prognathic patients. Twenty patients were selected who received orthognathic surgery after presurgical orthodontic treatment. The patients with skeletal and dental Class III malocclusion were operated upon with bilateral sagittal split ramus osteotomy and mandibular setback. The lateral and posteroanterior cephalometric radiographs were taken preoperatively, postoperative 1 day and 12 months later after the orthognathic surgery, and then the gonial angle and mandibular width were measured. The computerized statistical analysis was carried out with SPSS/PC program. The gonial angle at postoperative 1 day was decreased about $5.3^{\circ}$ than preoperative value and the gonial angle at postoperative 12 months was increased about $1.4^{\circ}$ than postoperative 1 day. So the gonial angle at postoperative 12 months was decreased about $3.9^{\circ}$ than preoperative value. The mean preoperative gonial angle was $125.35^{\circ}{\pm}7.36$, showing significantly high value than normal and mean gonial angle at postoperative 12 months was $121.45^{\circ}{\pm}6.81$, showing value near to normal. The mandibular width at postoperative 1 day was decreased about 1.1 mm than preoperative value and the mandibular width at postoperative 12 months was more decreased about 1.7 mm than postoperative 1 day. So the mandibular width at postoperative 12 months was decreased about 2.8 mm than preoperative value. These results indicate that sagittal split ramus osteotomy in mandibular prognathic patients with high gonial angle is effective to improvement of gonial angle. It is considered to be helpful for maintenance of postoperative stable gonial angle area that detailed postoperative care and follow-up.

COMPARATIVE STUDY OF FRACTURE STRENGTH DEFENDING ON THE THICKNESS OF SOME ALL CERAMIC CORES (수종의 전부도재관 코어의 두께에 따른 파절강도의 비교 연구)

  • Kim Doo-Yong;Lee Young-Soo;Park Won-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.49-57
    • /
    • 2004
  • Statement of problem : The increased awareness of esthetics in dentistry has brought the esthetic consideration in prosthetic restorations . Dental ceramics offer better esthetics for use of prosthetic restorations. Unfortunately, dental ceramic materials are not always the most suitable candidate materials since their inherently brittle nature. In recent years, basic research in ceramic science has led to the recognition or several approaches to strengthen and to enhance esthetics of ceramics. Several all ceramic systems use ceramic core and porcelain build up structures . Ceramic cores influence to strength of all ceramic crowns . So the strength of ceramic cores is important to all ceramic crowns. Purpose : The purpose of this study is to estimate the flexural strength of ceramic cores in some all ceramic systems. Material and method : A biaxial flexure test was conducted on three groups(Cergo, Empress 2, In-Ceram). Each group consisted of 30 discs of nearly identical dimension with a 0.5mm, 1.0mm, 1.5mm thickness and 12mm in diameter. The fracture load was recorded by Instron. Analysis of valiance(ANOVA) and Tukey's tests were performed using SAS statistical software. Results : 1.5mm thickness of specimens were significantly stronger than 0.5mm and 1.0mm thickness of specimens in Cergo and In-Ceram. But each sepecimen group of Empress 2 was no significantly strength by thickness. In order of In-Ceram, Empress 2 and Cergo has significantly stronger strength in the same thickness. Conclusion : In-Ceram is the strongest ceramic material in 3 materials. All the materials can be used according to the required characters.

A STUDY ON THE ILLUMINATION OF DENTAL CLINIC (치과 진료실의 조명에 관한 실태 조사연구)

  • Choi Jong-In;Kim Yu-Lee;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.374-382
    • /
    • 2006
  • Purpose: This study was designed to investigate the present conditions of illumination techniques in dental clinics in order to contribute improvement of operating environment. This study also aimed exploring qualitative and quantitative luminous intensity required for color temperature in dental clinic illumination, which was a critical part of esthetic dentistry. Materials and methods: A total of forty-eight local dental clinics were selected for sampling a) luminous intensity, and b) color temperature. The author measured the luminous intensity and the color temperature with lux meter and color meter respectively between 12pm and 2pm. The dental unit chair placed in the general operation positions were kept the distance 60 cm then all dental units were measured three times and averaged. The author measured the luminous intensity and color temperature with both common dental operating light and then without operating light in different office environments. The study was conducted under three conditions: 1 artificial illumination in clear day light 2. artificial illumination in cloudy day light, and 3. artificial illumination alone. Results : The results obtained were as follows. 1. The average luminous intensity in dental clinic lighting was 425 lux which was not sufficient to produce the optimal shade of the patient's teeth. Furthermore, the average luminous intensity even in full operating lighting was 9532 lux which fell short of the required level of 10,000 lux. 2. The average color temperature of all dental clinics surveyed was 5169 K which met the optimal range. However, only 33.3% fell in the correct region between 5,000-5,500 K as 25% were over 5,500 K and 41.6% were below 5,000 K. As a result, 66.7% were under insufficient color temperature conditions. 3. The dental unit chair placed next to a window, hence exposure to natural lighting, had significantly higher luminous intensity and color temperature compared to the dental unit chair which didn't have a window or natural lighting. 4. The data analysis revealed that only 6.3% of the dental clinic were met the standard of the average luminous intensity and color temperature.

Full-mouth rehabilitation of skeletal anterior open bite with severely decayed dentition: A case report (심한 우식을 동반한 골격성 전치부 개방 교합 환자의 전악 수복 증례)

  • Kim, Seong-A;Noh, Kwantae;Pae, Ahran;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.79-87
    • /
    • 2017
  • The open bite malocclusion is a common clinical entity and has multifactorial causes. Development of effective treatment plan and management is dependent on proper diagnosis. The skeletal open bite patient requires a coordinated orthodontic and orthognathic surgical approach to achieve stable occlusion, acceptable esthetics, and improved function. But in case of open bite with severely decayed dentition, restoration in the entire dentition is necessary. Using the facial analysis and diagnostic wax-up, the most effective treatment was prosthetic rehabilitation. The provisional restorations were fabricated to satisfy esthetic and functional requirements, which result in the uniformly distributed occlusal force, anterior and canine guidance. The inter-arch relationship, labio-dental harmony, and the soft tissue aspect, which is important to estimate the longevity were evaluated. Definitive restorations of monolithic zirconia were made by replicating provisional restorations by using the latest CAD/CAM technology. They were delivered to the patient and clinical follow-up observation was satisfactory.

Contemporary fashion design using Chinese ink technique based on Chi-Yun-Sheng-Tung (기운생동(氣韻生動)의 개념을 통해 본 수묵 기법의 패션 디자인)

  • Kim, Ji Young
    • The Research Journal of the Costume Culture
    • /
    • v.24 no.4
    • /
    • pp.441-456
    • /
    • 2016
  • This study considers the modern expression of oriental esthetics by analyzing the fashion design with the Chinese ink technique based on the concept of Chi-Yun-Sheng-Tung, which was regarded as the best rule of art creation in oriental history. This study was performed by conducting a literature review of related books and advanced studies, and then, collection analysis was done with photos derived from fashion websites (seoulfashionweek.org, chinafashionweek.org, vogue.com, firstview. com) from 2010 S/S to 2016 S/S. A total of 317 fashion photos of designs created using the Chinese ink technique by Korean designers at Seoul Fashion Week and Chinese designers at China Fashion Week were analyzed. The contemporary fashions created with the Chinese ink technique were characterized by, first, the bold brush strokes and natural spreading effects of Chinese ink, second, the emphasis of empty space by taking essential elements, and third, the coexistence of deep Chinese ink colors with modern primary colors. The formativeness of the contemporary fashions created with Chinese ink technique based on Chi-Yun-Sheng-Tung were as follows: first, temperance, pursuing spiritual and minimal expression, second, empty space, making design elements interact and pursue harmony, third, changeable rhythm, symbolizing the growth and variation revealing the power of life, and fourth, vitality, represented in the rhythmical movement of the brush. This study was based on the oriental esthetics inherent in Chi-Yun-Sheng-Tung, and it attempted to analyze contemporary fashion design. The aim was to show the possibility of modern applications to traditional values, and it can be a meaningful case in design planning based on culture.

Analysis Study on the Damage of Crack Happening with the Bending at CFRP Plate due to Stacking Angle (적층각도에 따른 CFRP 평판에서의 굽힘으로 발생한 크랙 파손에 관한 해석적 연구)

  • Hwang, Gue-wan;Cho, Jae-ung
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.3
    • /
    • pp.185-190
    • /
    • 2017
  • This study investigates the bending stress, shear stress and deformation energy happening at the inner fiber structure when the bending moment is applied to he specimen with flat shape composed of carbon fiber. As CFRP is composed of innumerable fibers with multi-axes, the stress under bending condition can be effectively distributed. Theses stresses is shown to increase again at the starting point as this angle of $60^{\circ}$. Therefore, the condition at the stacking angle of $60^{\circ}$ is seen to become most adequate under the state where the bending stress happens. On the basis of this study result, the damage property by the bending at the plate due to stacking angle was examined through the analytic approach. it is thought that this study can be devoted to the safe design for damage prevention and durabilty improvement. Also, the esthetic sense can be shown as the designed factor of shape with flat plate is grafted onto the convergence technique.

COMPARATIVE STUDY ON THE FRACTURE STRENGTH OF METAL-CERAMIC VERSUS COMPOSITE RESIN-VENEERED METAL CROWNS IN CEMENT-RETAINED IMPLANT-SUPPORTED CROWNS UNDER VERTICAL COMPRESSIVE LOAD

  • Pae, Ahran;Jeon, Kyung-A;Kim, Myung-Rae;Kim, Sung-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.295-302
    • /
    • 2007
  • Statement of problem. Fracture of the tooth-colored superstructure material is one of the main prosthetic complications in implant-supported prostheses. Purpose. The purpose of this in vitro study was to compare the fracture strength between the cement-retained implant-supported metal-ceramic crowns and the indirect composite resinveneered metal crowns under the vertical compressive load. Material and methods. Standard implants of external type (AVANA IFR 415 Pre-mount; Osstem Co., Busan, Korea) were embedded in stainless steel blocks perpendicular to their long axis. Customized abutments were fabricated using plastic UCLA abutments (Esthetic plastic cylinder; Osstem Co., Busan, Korea). Thirty standardized copings were cast with non-precious metal (Rexillium III, Pentron, Walling ford, Conn., USA). Copings were divided into two groups of 15 specimens each (n = 15). For Group I specimens, metal-ceramic crowns were fabricated. For Group II specimens, composite resin-veneered (Sinfony, 3M-ESPE, St. Paul, MN, USA) metal crowns (Sinfony-veneered crowns) were fabricated according to manufacturer's instructions. All crowns were temporary cemented and vertically loaded with an Instron universal testing machine (Instron 3366, Instron Corp., Norwood, MA, USA). The maximum load value (N) at the moment of complete failure was recorded and all data were statistically analyzed by independent sample t-test at the significance level of 0.05. The modes of failure were also investigated with visual analysis. Results. The fracture strength of Sinfony-veneered crowns ($2292.7{\pm}576.0N$) was significantly greater than that of metal-ceramic crowns ($1150.6{\pm}268.2N$) (P < 0.05). With regard to the failure mode, Sinfony-veneered crowns exhibited adhesive failure, while metal-ceramic crowns tended to fracture in a manner that resulted in combined failure. Conclusion. Sinfony-veneered crowns demonstrated a significantly higher fracture strength than that of metal-ceramic crowns in cement-retained implant-supported prostheses.

Retrospective analysis of $frialit-2^{(R)}$ implant system placed in maxilla (상악에 식립된 Frialit-2 임플란트의 성공률에 대한 후향적 연구)

  • Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Shim, June-Sung;Cho, Kyoo-Sung;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.2
    • /
    • pp.449-460
    • /
    • 2005
  • Objectives Aim of this study was to evaluate the clinical use and the efficacy of Frialit-2 implant system. Experimental Methods Fifty nine patients received placement of Frilalit-2 implants(137 implants) in their maxillary anterior and posterior sites(40 and 97 implants). Intraoral & clinical examination, chart review and radiographs were taken from each patient. Results 1. The total implant survival rate was 92.7% after a mean follow-up period of 19.9 months. 2. The implant survival rate placed in anterior region was 97.5%. 3. The implant survival rate placed in posterior region was 90.7%. 4. The implant survival rate placed in atrophic posterior maxilla with advanced technique (GBR, Sinus elevation) was 87.2%. 5. The implant survival rate placed in type N(D4) bone was 82%, while 95.7% in type III (D3), and 100% in type II(D2) bone. 6. Most of the failed implants(7 of 10) were removed during the maintenance stage after prosthodontic treatment. Conclusion It was concluded that Frialit-2 implant could be used satisfactorily in the esthetic anterior region, but the use in the posterior region, especially with poor bone quality and quantity, further studies are needed.