• Title/Summary/Keyword: errors of zero

Search Result 226, Processing Time 0.023 seconds

Development of a fast reactor multigroup cross section generation code EXUS-F capable of direct processing of evaluated nuclear data files

  • Lim, Changhyun;Joo, Han Gyu;Yang, Won Sik
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.340-355
    • /
    • 2018
  • The methods and performance of a fast reactor multigroup cross section (XS) generation code EXUS-F are described that is capable of directly processing Evaluated Nuclear Data File format nuclear data files. RECONR of NJOY is used to generate pointwise XS data, and Doppler broadening is incorporated by the Gauss-Hermite quadrature method. The self-shielding effect is incorporated in the ultrafine group XSs in the resolved and unresolved resonance ranges. Functions to generate scattering transfer matrices and fission spectrum matrices are realized. The extended transport approximation is used in zero-dimensional calculations, whereas the collision probability method and the method of characteristics are used for one-dimensional cylindrical geometry and two-dimensional hexagonal geometry problems, respectively. Verification calculations are performed first for various homogeneous mixtures and cylindrical problems. It is confirmed that the spectrum calculations and the corresponding multigroup XS generations are performed adequately in that the reactivity errors are less than 50 pcm with the McCARD Monte Carlo solutions. The nTRACER core calculations are performed with the EXUS-F-generated 47 group XSs for the two-dimensional Advanced Burner Reactor 1000 benchmark problem. The reactivity error of 160 pcm and the root mean square error of the pin powers of 0.7% indicate that EXUF-F generates properly the broad-group XSs.

Spatial target path following and coordinated control of multiple UUVs

  • Qi, Xue;Xiang, Peng;Cai, Zhi-jun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.832-842
    • /
    • 2020
  • The coordination control of multiple Underactuated Underwater Vehicles (UUVs) moving in three dimensional space is investigated in this paper. The coordinated path following control task is decomposed into two sub tasks, that is, path following control and coordination control. In the spatial curve path following control task, path following error dynamics is build in the Serret-Frenet coordinate frame. The virtual reference object can be chosen freely on the desired spatial path. Considering the speed of the UUV, the line-of-sight navigation is introduced to help the path following errors quickly converge to zero. In the coordination control sub task, the communication topology of multiple UUVs is described by the graph theory. The speed of each UUV is adjusted to achieve the coordination. The path following system and the coordination control system are viewed as the feedback connection system. Input-to-state stable of the coordinated path following system can be proved by small gain theorem. The simulation experiments can further demonstrate the good performance of the control method.

Identification of flutter derivatives of bridge decks using stochastic search technique

  • Chen, Ai-Rong;Xu, Fu-You;Ma, Ru-Jin
    • Wind and Structures
    • /
    • v.9 no.6
    • /
    • pp.441-455
    • /
    • 2006
  • A more applicable optimization model for extracting flutter derivatives of bridge decks is presented, which is suitable for time-varying weights for fitting errors and different lengths of vertical bending and torsional free vibration data. A stochastic search technique for searching the optimal solution of optimization problem is developed, which is more convenient in understanding and programming than the alternate iteration technique, and testified to be a valid and efficient method using two numerical examples. On the basis of the section model test of Sutong Bridge deck, the flutter derivatives are extracted by the stochastic search technique, and compared with the identification results using the modified least-square method. The Empirical Mode Decomposition method is employed to eliminate noise, trends and zero excursion of the collected free vibration data of vertical bending and torsional motion, by which the identification precision of flutter derivatives is improved.

The Design of Sliding Model Controller with Perturbation Estimator Using Observer-Based Fuzzy Adaptive Network

  • Park, Min-Kyu;Lee, Min-Cheol;Go, Seok-Jo
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.3 no.2
    • /
    • pp.117-123
    • /
    • 2001
  • To improve control performance of a non-linear system, many other reserches have used the sliding model control algorithm. The sliding mode controller is known to be robust against nonlinear and unmodeled dynamic terms. However, this algorithm raises the inherent chattering caused by excessive switching inputs around the sliding surface. Therefore, in order to solve the chattering problem and improve control performance, this study has developed the sliding mode controller with a perturbation estimator using the observer-based fuzzy adaptive network. The perturbation estimator based on the fuzzy adaptive network generates the control input of compensating unmodeled dynamics terms and disturbance. And the weighting parameters of the fuzzy adaptive network are updated on-line by adaptive law in order to force the estimation errors converge to zero. Therefore, the combination of sliding mode control and fuzzy adaptive network gives rise to the robust and intelligent routine. For evaluation control performance of the proposed approach, tracking control simulation is carried is carried out for the hydraulic motion simulator which is a 6-degree of freedom parallel manipulator.

  • PDF

Neural Network Control of Humanoid Robot (휴머노이드 로봇의 뉴럴네트워크 제어)

  • Kim, Dong-W.;Kim, Nak-Hyun;Park, Gwi-Tae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.10
    • /
    • pp.963-968
    • /
    • 2010
  • This paper handles ZMP based control that is inspired by neural networks for humanoid robot walking on varying sloped surfaces. Humanoid robots are currently one of the most exciting research topics in the field of robotics, and maintaining stability while they are standing, walking or moving is a key concern. To ensure a steady and smooth walking gait of such robots, a feedforward type of neural network architecture, trained by the back propagation algorithm is employed. The inputs and outputs of the neural network architecture are the ZMPx and ZMPy errors of the robot, and the x, y positions of the robot, respectively. The neural network developed allows the controller to generate the desired balance of the robot positions, resulting in a steady gait for the robot as it moves around on a flat floor, and when it is descending slope. In this paper, experiments of humanoid robot walking are carried out, in which the actual position data from a prototype robot are measured in real time situations, and fed into a neural network inspired controller designed for stable bipedal walking.

The Position and Speed Estimation of Switched Reluctance Motor using Sliding Mode Observer

  • Yang, Lee-Woo;Kim, Bo-Youl;Kim, Jin-Soo;Kim, Young-Seok
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.774-779
    • /
    • 1998
  • For the speed control of motors, the position or speed sensors are necessary to obtain the position information of the rotor. Specially, SRM(Switched Reluctance Motor) needs an accurate rotor position data because both the rotor and the stator have a salient pole structure. High functional sensors like resolver or encoder are expensive and have complex connecting lines to the controller so the pure signals are apt to be mixed with noised. In the sight of SRM drives, the high temperature, heavy dust, and the EMI surroundings reduce the reliability of speed and position sensors. Therefore, the speed and position sensorless control algorithms using observer have been accepted widely. In this paper An adaptive sliding observer is described to control the SRM without speed or position sensors. The adaptive sliding observer is set on the basis of variable structure control theory. The sliding surface is constructed by current error terms and this surface guarantees the errors converge to "zero". The stability of observer is affirmed by Lyapunov stability analysis and popov's hyper stability theory.ty theory.

  • PDF

A study on monitoring of fatigue using the $2^{nd}$ order maximum entropy method ($2^{nd}$ order maximum entropy method를 이용한 근피로도의 측정에 관한 연구)

  • Cho, S.J.;Kim, M.S.;Lee, K.W.;Kim, K.G.;Kim, S.L.;Park, H.S.;Lee, K.M.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1990 no.05
    • /
    • pp.47-50
    • /
    • 1990
  • In this study, the degree of spectral transfer to lower frequency caused by accumulation of Latic acid inside the muscle is estimated the convintional dip analysis, zero-crossing method and FFT method have intrinsic errors and estimation problems in case of severe noise. The new spectral analysis method using "$2^{nd}$ order Maximum Entropy Method" was applied to estimate mean frequency and we confirmed that this new method yields fast and reliable estimation over the FFT method.

  • PDF

A Robust Fault Location Algorithm for Single Line-to-ground Fault in Double-circuit Transmission Systems

  • Zhang, Wen-Hao;Rosadi, Umar;Choi, Myeon-Song;Lee, Seung-Jae;Lim, Il-Hyung
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • This paper proposes an enhanced noise robust algorithm for fault location on double-circuit transmission line for the case of single line-to-ground (SLG) fault, which uses distributed parameter line model that also considers the mutual coupling effect. The proposed algorithm requires the voltages and currents from single-terminal data only and does not require adjacent circuit current data. The fault distance can be simply determined by solving a second-order polynomial equation, which is achieved directly through the analysis of the circuit. The algorithm, which employs the faulted phase network and zero-sequence network with source impedance involved, effectively eliminates the effect of load flow and fault resistance on the accuracy of fault location. The proposed algorithm is tested using MATLAB/Simulink under different fault locations and shows high accuracy. The uncertainty of source impedance and the measurement errors are also included in the simulation and shows that the algorithm has high robustness.

Predictive Current Control for Multilevel Cascaded H-Bridge Inverters Based on a Deadbeat Solution

  • Qi, Chen;Tu, Pengfei;Wang, Peng;Zagrodnik, Michael
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.76-87
    • /
    • 2017
  • Finite-set predictive current control (FS-PCC) is advantageous for power converters due to its high dynamic performance and has received increasing interest in multilevel inverters. Among multilevel inverter topologies, the cascaded H-bridge (CHB) inverter is popular and mature in the industry. However, a main drawback of FS-PCC is its large computational burden, especially for the application of CHB inverters. In this paper, an FS-PCC method based on a deadbeat solution for three-phase zero-common-mode-voltage CHB inverters is proposed. In the proposed method, an inverse model of the load is utilized to calculate the reference voltage based on the reference current. In addition, a cost function is directly expressed in the terms of the voltage errors. An optimal control actuation is selected by minimizing the cost function. In the proposed method, only three instead of all of the control actuations are used for the calculations in one sampling period. This leads to a significant reduction in computations. The proposed method is tested on a three-phase 5-level CHB inverter. Simulation and experimental results show a very similar and comparable control performance from the proposed method compared with the traditional FS-PCC method which evaluates the cost function for all of the control actuations.

Synchronizing control of intelligent indoor lift system (지능형 실내 위치전환 시스템의 동기제어)

  • 양호남;양현석;최용제;홍만복
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.330-333
    • /
    • 2003
  • In this thesis. the application of the synchronizing control of the intelligent indoor lift system is showed. The separate axes of the indoor lift system are driven independently. PID controller, synchronous flexible logic compensating method and tilt sensor are applied to enhance the performance of the intelligent indoor lift system. the tilt sensor senses the horizontal error of the whole system. PID controller and synchronous flexible logic are used to compensate the synchronous errors of both the separate axes and whole system to be zero. Namely, using not the hardware coupling but the software algorithm. the indoor life system is operated without the error. Before applying the real system, the simulation using matlab testifies the possibility of the lift system. And the realization of the system is demonstrated with two DC servo motors. In the experiment test, flexible logic to compensate the synchronous error is chosen by the comparative method. the indoor lift system has to be considered the loading factor as the disturbance. Because the intelligent indoor lift system is developed to support the patients who don't change for themselves to move. finally, the system which considers the weight of the patient as the disturbance can carry the patients safely without synchronous and position error.

  • PDF