• Title/Summary/Keyword: error range

Search Result 2,811, Processing Time 0.032 seconds

Estimate of Compressive Strength for Concrete using Ultrasonics by Multiple Regression Analysis Method (초음파를 이용한 중회귀분석법에 의한 콘크리트의 압축강도추정)

  • Park, I.G.;Han, E.K.;Kim, W.K.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.11 no.2
    • /
    • pp.22-31
    • /
    • 1991
  • Various types of ultrasonic techniques have been used for the estimation of compressive strength of concrete structures. However, conventional ultrasonic velocity method using only longitudial wave cannot be determined the compressive strength of concrete structures with accuracy. In this paper, by using the introduction of multiple parameter, e. g. velocity of shear wave, velocity of longitudinal wave, attenuation coefficient of shear wave, attenuation coefficient of longitudinal wave, combination condition, age and preservation method, multiple regression analysis method was applied to the determination of compressive strength of concrete structures. The experimental results show that velocity of shear wave can be estimated compressive strength of concrete with more accuracy compared with the velocity of longitudinal wave, accuracy of estimated error range of compressive strength of concrete structures can be enhanced within the range of ${\pm}$10% approximately.

  • PDF

Optical Probe of white Light Interferometry for Precision Coordinate Metrology (정밀 삼차원 측정을 위한 백색광 간섭 광학 프로브 개발)

  • 김승우;진종한;강민구
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.195-198
    • /
    • 2002
  • Demand for high precision measurement of large area is increasing in many industrial fields. White-light Scanning Interferometer(WSI) is a well-known method for 3D profile measurement. However WSI has some limitations in a measurement range because of the sensing mechanism. Therefore, in this paper we use a heterodyne laser interferometer to get over the limitations of a short measurement range in WSI, We suggest a new WSI system combined with heterodyne laser interferometer. This system is aimed at eliminating Abbe error with measuring the focus point directly. With the use of triggering functionality of WSI, we can use this system as a probe of a precision stage such as a probe of CMM. The suggested system gives a repeatability of 87 nm in the absolute distance measurement test under the laboratory environment.

  • PDF

A Fundamental Study on the Estimation of Water Content in Fresh Concrete by the Heat-Drying Method (가열건조법에 의한 굳지않은 콘크리트의 단위수량 추정에 관한 기초적 연구)

  • 김영득;황인성;전충근;한천구;김광서
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.341-346
    • /
    • 2002
  • This study is intended to check the possibility to estimate water content by heat-drying method with variation of W/C and slump. According to the results, in case of electric range method, when water content is less than 165kg/m$^3$ in mixture, it is estimated more and in more than 165kg/m$^3$, it is estimated less. It shows that water content in gas burner method is estimated less by about 2kg/m$^3$. Also, estimated water content shows difference by less than 12kg/m$^3$ in electric range method and by less than 12kg/m$^3$ in gas burner method. Therefore, it is thinked that if tested without error from preparing a sample to calculating amount of water, water content will be estimated exactly in the construction field.

  • PDF

A New Motor Speed Estimator using Kalman Filter in Low Speed Range (칼만 필터를 이용한 저속 영역에서의 새로운 속도 추정기)

  • Kim, Heui-Wook;Sul, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.576-578
    • /
    • 1994
  • In this. paper, a new technique to estimate both the instantaneous speed and disturbance load torque using a low precision shaft encoder in very low speed range is proposed. To detect the instantaneous speed and disturbance load torque, the Kalman filter which is an optimal full order estimator is used. Experimental results conform the validity of the proposed estimation technique. The effects of parameter variations are discussed, and it is verified that the system is robust to the modeling error.

  • PDF

Quantitative NMR Analysis of PTMEG compounds

  • Kim, Gilhoon;Won, Hoshik
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.20 no.1
    • /
    • pp.7-12
    • /
    • 2016
  • PTMEG(Polytetramethylene ether glycol) is a polymer compound widely used as a wide range of applications in the textile industry. PTMEG substance carrying various 1,800~2,000 molecular weight are mainly used as the raw material of the spandex production. Molecular weight and degree of polymerization value for 4 different PTMEG samples under pilot plant scale synthetic process were determined by a new quantitative NMR method. In NMR experiments, p-toluenesulfonic acid(TSOH) was used for external standard material of PTMEG quantitative analysis. were measuring The concentration of the primary standard TSOH was measured by UV/Vis spectroscopy. By using NMR peak assignments and the integral values of designated proton NMR peaks, We were able to measure the % composition of the synthetic PTMEG polymers, concentrations, molecular weight and the degree of polymerization that show the synthetic process of each manufacturing pilot plant. By utilizing a newly developed quantitative NMR method were able to obtain the molecular weight of PTMEG samples within 0.08 error % range.

Analysis of Main Design Factors for Developing a Soil Water Content Sensor Using Impedance Spectroscopy (Impedance Spectroscopy를 이용한 토양 수분함량 센서의 주요 설계인자 분석)

  • Lee, Dong-Hoon;Cho, Yong-Jin;Chang, Young-Chang;Lee, Kyou-Seung
    • Journal of Biosystems Engineering
    • /
    • v.33 no.4
    • /
    • pp.269-275
    • /
    • 2008
  • This study was conducted to design an impedance sensor that can measure soil water content of soils. Partial least square regression (PLSR) was applied to soil impedance data preprocessed with a smoothing method. An optimal sub-spectrum size and wavelength range were determined by comparing the coefficient of determination ($R^2$) and root mean square error (RMSE) of the PLSR models obtained using soil impedance data. various PLS analysis. Based on the PLSR analysis, it would be concluded that the optimal spectrum measurement range was $32.0{\sim}50.0\;MHz$ with the optimal sub-spectrum size of about 18.5 MHz.

A Weighted Least Square Method for Optimization of Thinned Sensor Arrays (희소어레이의 최적화를 위한 계수 최소 자승 방법)

  • 장병건
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.78-83
    • /
    • 1999
  • This paper concerns a least square method for pattern optimization of a thinned sensor array in which the squared error between a desired pattern and a synthesized one is minimized. A weighting function is applied in the function with respect to the array visual range for a symmetric and asymmetric configuration for sensor spacing. An exponential weighting function is proposed to control the sidelobes efficiently around the mainbeam and to generate a uniform sidelobe. The resulting pattern may be employed to eliminate incoming interferences distributed uniformly around the array visual range.

  • PDF

Gaze Direction Estimation Method Using Support Vector Machines (SVMs) (Support Vector Machines을 이용한 시선 방향 추정방법)

  • Liu, Jing;Woo, Kyung-Haeng;Choi, Won-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.4
    • /
    • pp.379-384
    • /
    • 2009
  • A human gaze detection and tracing method is importantly required for HMI(Human-Machine-Interface) like a Human-Serving robot. This paper proposed a novel three-dimension (3D) human gaze estimation method by using a face recognition, an orientation estimation and SVMs (Support Vector Machines). 2,400 images with the pan orientation range of $-90^{\circ}{\sim}90^{\circ}$ and tilt range of $-40^{\circ}{\sim}70^{\circ}$ with intervals unit of $10^{\circ}$ were used. A stereo camera was used to obtain the global coordinate of the center point between eyes and Gabor filter banks of horizontal and vertical orientation with 4 scales were used to extract the facial features. The experiment result shows that the error rate of proposed method is much improved than Liddell's.

B-Scan Image Processing Technique by Using Ultrasonic Microscope System (초음파 현미경 시스템에 의한 B-스캔 영상처리 기술)

  • 고대식;전계석
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.12
    • /
    • pp.1889-1893
    • /
    • 1990
  • In this paper, ultrasonic microscope system has been constructed with the small aperturre acoustic lens and the angle controller, and the new type of B-scanultransonic imaging has been analyzed. The system with small aperture lens was used to detect flaw existing within the thick specimen and its resolution was in the range of one wavelength at interior plane of sample. The anle controller was used to excited surface acoustic wave or shear wave. In order to obtain B-scan image of the flaw existig at interior of solids, shear wave has been excited and backscattering signals from the flaw have been processed. In experimental results, B-scan ultransonic images have been obtain from the flaws of varable shape and measured flaw size from the images has been in good agreement with practical size in the range of 10% error.

  • PDF

A Study on the High-frequency Operation Characteristics of the High-pressure Sodium Lamps (고압 나트륨램프의 고주파 방전특성 연구)

  • Chee, Chol-Kon;Kim, Hoon
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.11
    • /
    • pp.495-502
    • /
    • 1986
  • The change of the discharge characteristics of the high-pressure sodium (HPS) lamps is investigated over a power source frequency range of 60 Hz to 30, 000 Hz. As the frequency increases, the light and electrical characteristics of the HPS lamps are improved since the re-ignition is not needed due to the constant electron density, and the cathode fall is reduced. But at the certain frequency range, the arc instability called acoustic resonance occurs, and the arc tube is damaged. Regarding these characteristics and the kind of the illuminating system, a proper frequency is selected to operate the HPS lamps. And a new measuring system using a computer and the storage-scope is developed to avoid the error of the ordinary gauges at high frequency power.

  • PDF