Clinical Evaluation of the Accuracy of Electronic Home Blood Pressure Measuring Devices (가정용 전자식 혈압계의 정확도에 대한 임상적 평가)

  • Choo Ji-Na
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.9 no.1
    • /
    • pp.101-112
    • /
    • 2002
  • Purpose: This study evaluated the accuracy of electronic devices compared with mercury sphygmomanometer. Of 132 outpatients with electronic devices. 77 who possessed oscillometric cuff devices participated in this study. Method: When the blood pressure was measured, all electronic devices were connected by means of a Y-connector to a mercury sphygmomanometer. Using the simultaneous same arm approach, each comparison was carried out three times at 2-minute intervals. Results: Compared with the mercury sphygmomanometer, the electronic devices underestimated systolic and diastolic blood pressure, respectively by $4.0{\pm}5.8mmHg$ and $2.5{\pm}67mmHg$, which satisfies the standard error range of the American Association for the Advancement of Medical Instrumentation. According to the British Hypertension Society criteria, these differences achieved C grade for both systolic and diastolic pressure. For the graphical analysis, the differences had a tendency to fulfill the permitted error limits in both diastolic and systolic blood pressure. Moreover, the purchase duration was not correlated with the accuracy of electronic devices. Conclusion: These results indicate that difference in blood pressure between electronic devices and mercury sphygmomanometer is within the standard error. Therefore, electronic blood pressure measuring devices may be useful for therapeutic self-management of hypertension.

  • PDF

Hybrid TOA/AOA Cooperative Mobile Localization in 4G Cellular Networks

  • Wu, Shixun;Wang, Shuliang;Xu, Kai;Wang, Honggang
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.2 no.2
    • /
    • pp.77-85
    • /
    • 2013
  • this study examined hybrid Time of Arrival/Angle of Arrival (TOA/AOA) localization technique in a cellular network. Based on the linearized equations from the TOA and AOA measurements, the weighted least square (WLS) method is proposed to obtain the location estimation of a mobile station (MS) by analyzing the statistical properties of the error vector in Line of Sight (LOS) and Non-line of Sight (NLOS) environments, respectively. Moreover, the precise expression of the Cramer-Rao lower bound (CRLB) for hybrid TOA/AOA measurements in different LOS/NLOS conditions was derived when the LOS error is a Gaussian variable and the NLOS error is an exponential variable. The idea of cooperative localization is proposed based on the additional information from short-range communication among the MSs in fourth generation (4G) cellular networks. Therefore, the proposed hybrid TOA/AOA WLS method can be improved further with the cooperative scheme. The simulation results show that the hybrid TOA/AOA method has better performance than the TOA only method, particularly when the AOA measurements are accurate. Moreover, the performance of the hybrid TOA/AOA method can be improved further by the cooperative scheme.

  • PDF

Characteristics of Needle Insertion Performance of Automated Biopsy Device for Robotic Needle Insertion Type Intervention: Insertion Depth and Accuracy (로봇 자동화 바늘삽입형 중재시술을 위한 자동화 생검장치의 바늘삽입 특성: 바늘삽입 깊이 및 삽입정확도)

  • Moon, Youngjin;Choi, Jaesoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.7
    • /
    • pp.565-570
    • /
    • 2016
  • This paper presents the characteristics related to needle insertion of a robotic device for the automated biopsy procedure. The automated biopsy device, a main component of the robotic needle insertion type intervention system, allows performance of the full biopsy procedure, except for anesthesia, without direct handling of a radiologist or a tele-operated control. In this study, the needle length parameters corresponding to various insertion depths and precision for needle insertion of the automated biopsy device, are discussed. There were two combinations of needle length parameters for appropriate needle insertion and motion capture-based measurement was performed; 0.156 mm error for the 90 mm length commanded insertion displacement was measured. The pre-defined goal is a maximum 1 mm error and thus our measured error is within the acceptable range. In the repeatability check, it was also shown that the device can implement a highly accurate insertion.

A Fuzzy-based Fusion Wireless Localization Method (퍼지기반 융합 무선위치추정기법)

  • Cho, Seong-Yun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.4
    • /
    • pp.507-512
    • /
    • 2015
  • In the wireless localization systems using range measurements, iteration method-based approximated solutions have been used. Also, linear closed-form solutions have been investigated in the light of local minimum problem and computational load. However, each closed-form solution has individual error factors that cause usage limit of the solutions. In this paper, a fusion method integrating two representative closed-form solutions is presented. The presented method cancels the error factors of each solution out. Weights for integrating the standalone solutions are determined using the error factors-based fuzzy method. The performance of the proposed method is verified using some simulation results.

Selection and Verification of 3D Finite Element Method Model for Silicone Foot Sensor with Low Detection Pressure (낮은 감지 압력신호 값을 가지는 실리콘 족적 센서에 대한 3차원 유한요소 해석 모델 선정 및 검증)

  • Seong, Byuck Kyung;Seo, Hyung Kyu;Kim, Dong Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.11
    • /
    • pp.1299-1307
    • /
    • 2014
  • In this work, an appropriate analysis model of a precise foot sensor with low detection pressure capability under a low range of variation in the dimensional variables was proposed. With a simple two-dimensional model, it was found that a remarkably high error level sometimes occurred between the analysis and experimental results. In order to overcome the error and improve the performance, a three-dimensional model was introduced, and the detection pressure and sensor characteristics were compared with those of the experimental results, which showed its enhanced performance with less error and higher precision.

Development of the Algorithm for Optimizing Wavelength Selection in Multiple Linear Regression

  • Hoeil Chung
    • Near Infrared Analysis
    • /
    • v.1 no.1
    • /
    • pp.1-7
    • /
    • 2000
  • A convenient algorithm for optimizing wavelength selection in multiple linear regression (MLR) has been developed. MOP (MLP Optimization Program) has been developed to test all possible MLR calibration models in a given spectral range and finally find an optimal MLR model with external validation capability. MOP generates all calibration models from all possible combinations of wavelength, and simultaneously calculates SEC (Standard Error of Calibration) and SEV (Standard Error of Validation) by predicting samples in a validation data set. Finally, with determined SEC and SEV, it calculates another parameter called SAD (Sum of SEC, SEV, and Absolute Difference between SEC and SEV: sum(SEC+SEV+Abs(SEC-SEV)). SAD is an useful parameter to find an optimal calibration model without over-fitting by simultaneously evaluating SEC, SEV, and difference of error between calibration and validation. The calibration model corresponding to the smallest SAD value is chosen as an optimum because the errors in both calibration and validation are minimal as well as similar in scale. To evaluate the capability of MOP, the determination of benzene content in unleaded gasoline has been examined. MOP successfully found the optimal calibration model and showed the better calibration and independent prediction performance compared to conventional MLR calibration.

Effect of initial ground temperature measurement on the design of borehole heat exchanger (초기 지중온도 측정이 지중 열교환기 설계에 미치는 영향)

  • Song, Yoon-ho;Kim, Seong-Kyun;Lee, Kang-Kun;Lee, Tae-Jong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.600-603
    • /
    • 2009
  • We compared relative importance of thermal conductivity and initial ground temperature in designing borehole heat exchanger network and also we test accuracy of ground temperature estimation in thermal response test using a proven 3-D T-H modeler. The effect of error in estimating ground temperature on calculated total length of borehole heat exchanger was more than 3 times larger than the case of thermal conductivity in maximum 20% error range. Considering 10% of error in estimating thermal conductivity is generally acceptable, we have to define the initial ground temperature within 5% confidence level. Utilizing the mean annual ground surface temperature and the geothermal gradient map compiled so far can be a economic way of estimating ground temperature with some caution. When performing thermal response test for estimating ground temperature as well as measuring thermal conductivity, minimum 100 minutes of ambient circulation is required, which should be even more in case of very cold and hot seasons.

  • PDF

Verification of GPS Aided Error Compensation Method and Navigation Algorithm with Raw eLoran Measurements (실제 eLoran TOA 측정치를 이용한 GPS Aided 오차 보상 기법과 항법 알고리즘의 검증)

  • Song, Se-Phil;Choi, Heon-Ho;Kim, Young-Baek;Lee, Sang-Jeong;Park, Chan-Sik
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.9
    • /
    • pp.941-946
    • /
    • 2011
  • The Loran-C, a radio navigation system based on TDOA measurements is enhanced to eLoran using TOA measurements instead of TDOA measurements. Many error factors such as PF, SF, ASF, clock errors and unknown biases are included in eLoran TOA measurements. Because these error factors can cause failure in eLoran navigation algorithm, these errors must be compensated for high accuracy eLoran navigation results. Compensation of ASF and unknown biases are difficult to calculate, while the others such as PF and SF are relatively easy to eliminate. In order to compensate all errors in eLoran TOA measurements, a simple GPS aided bias compensation method is suggested in this paper. This method calculates the bias as the difference of TOA measurement and the range between eLoran transmitters and the receiver whose position is determined using GPS. The real data measured in Europe are used for verification of suggested method and navigation algorithm.

A High Current Efficiency CMOS LDO Regulator with Low Power Consumption and Small Output Voltage Variation

  • Rikan, Behnam Samadpoor;Abbasizadeh, Hamed;Kang, Ji-Hun;Lee, Kang-Yoon
    • Journal of IKEEE
    • /
    • v.18 no.1
    • /
    • pp.37-44
    • /
    • 2014
  • In this paper we present an LDO based on an error amplifier. The designed error amplifier has a gain of 89.93dB at low frequencies. This amplifier's Bandwidth is 50.8MHz and its phase margin is $59.2^{\circ}C$. Also we proposed a BGR. This BGR has a low output variation with temperature and its PSRR at 1 KHz is -71.5dB. For a temperature variation from $-40^{\circ}C$ to $125^{\circ}C$ we have just 9.4mV variation in 3.3V LDO output. Also it is stable for a wide range of output load currents [0-200mA] and a $1{\mu}F$ output capacitor and its line regulation and especially load regulation is very small comparing other papers. The PSRR of proposed LDO is -61.16dB at 1 KHz. Also we designed it for several output voltages by using a ladder of resistors, transmission gates and a decoder. Low power consumption is the other superiority of this LDO which is just 1.55mW in full load. The circuit was designed in $0.35{\mu}m$ CMOS process.

Comparative Analysis on the Mock-ups' Configuration and Monitoring Protocol System of Advanced Daylighting Systems for Daylighting Experiment - Focused on IEA SHC Task21- (첨단채광시스템 실험용 Mock-Up 모형의 형상 및 모니터링 프로토콜 시스템에 관한 비교분석 - IEA SHC Task21을 중심으로-)

  • Jeong, In-Young;Choi, Sang-Hyun;Kim, Jeong-Tai
    • KIEAE Journal
    • /
    • v.4 no.1
    • /
    • pp.11-20
    • /
    • 2004
  • Innovative daylighting systems in buildings in various climatic zones around the world have been developed under the IEA SHC Task21. The performance assessment were obtained by monitoring the most systems using full-scale test model rooms or actual buildings under real sky conditions. This study aims to analyze the configuration and monitoring system of the nine Mock-up models of the IEA SHC Task21 comparatively. For the purpose, the geometry of the test rooms (length, width, height, window area, glazed area and occupied), reflectance of walls, floor and ceiling, transmittance of glazing (transmittance for hemispherical irradiation, normal irradiation and U-value) were compared. And equipment for measurement (manufacturer, range, calibration, maximum calibration error, cosine response error, fatigue error), and data acquisition system (manufacturer, type, number of differential analogue input channels, A/D converter resolution in bits, data acquisition software) were also analyzed comparatively. Some findings of these experimental methodology of standard monitoring have been proven to be a valuable one for future assessment of advanced daylighting systems in our country.