• Title/Summary/Keyword: error range

Search Result 2,811, Processing Time 0.026 seconds

Rapid Chloride Penetration Test for Concrete Based on the Electrochemical Method (전기 영동법에 기초한 콘크리트의 급속 염소이온 확산 특성 평가)

  • Oh, Sang-Gyun;Park, Dong-Cheon
    • Journal of Navigation and Port Research
    • /
    • v.34 no.10
    • /
    • pp.787-792
    • /
    • 2010
  • It is necessary to predict the penetration of chloride ions for designing RC construction in marine environments. However, it takes a long time to obtain chloride migration coefficients. Therefore, the rapid chloride penetration test (RCPT) is generally used to shorten the test time. But there is a difference between chloride migration coefficients determined by rapid chloride penetration tests and those based on exposure in marine environments. In this study, we evaluated the effect on the chloride ion migration coefficient caused by a change in voltage and NaCl concentration. We also compared the relationship between the chloride ion migration coefficient by RCPT and that by exposure in marine environments. As a result of the experiments, we found that there is only a small change in the experimental factors based on changes in voltage and NaCl concentration and since they are so small, we can conclude that they are in the range of experimental error and test results from chloride ion migration coefficients by RCPT and exposure were very different from each other. In the exposure experiments, when the water-cement ratio was increased, the smaller fine air gaps in concrete affected the chloride ion migration coefficient.

A Correction Method of Dose to Attenuation Rate of Transmitting Photon Beam Through Couch Top for Radiosurgery Using Novalis (노발리스를 이용한 방사선 수술시 치료테이블을 투과하는 광자선의 감쇠율에 따른 선량 보정방법)

  • Kim, Sung-Joon;Shin, Hyun-Soo;Ko, Seung-Young;Park, Hye-Li;Kim, Ja-Young;Lee, Bo-Mi;Yea, Ji-Woon;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.12-17
    • /
    • 2011
  • This study has its own goal to deliver the accurate dose on the target volume by calculating and modifying the attenuation rate of photon beam transmitting the couch top with geometric model. The experiment was that the transmission rate and attenuation rate of photon beam transmitting the couch top was predicted by the geometric model, then compared and analyzed with what was measured experimentally based on that. The result showed that the predicted value by the geometric model accorded closely with the experimental value. In addition, in order to judge whether the practical clinical application is available, the point dose, measured after modifying the attenuation rate modelinged according to the treatment plan of a patient of spine radiosurgery, was compared with the one done nothing. The result was that the former showed decreased error range with treatment planned one than the latter. This papers calculated the transmission and attenuation rate with the geometric model transmitting the couch top and verified it experimentally. This method is expected to be very useful in not only the radiosurgery using Novalis but also the general radiation therapy.

Evaluation of Dual-channel Compound Method for EBT3 Film Dosimetry

  • Kang, Sang-Won;Chung, Jin-Beom;Kim, Kyeong-Hyeon;Eom, Keun-Yong;Song, Changhoon;Lee, Jeong-Woo;Cho, Woong;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.28 no.1
    • /
    • pp.16-21
    • /
    • 2017
  • This study assessed the feasibility of a dual-channel (DC) compound method for film dosimetry. The red channel (RC) is usually used to ensure dosimetric quality using a conventional fraction dose because the RC is more accurate at low doses within 3 Gy than is the green channel (GC). However, the RC is prone to rapid degradation of sensitivity at high doses, while degradation of the GC is slow. In this study, the DC compound method combining the RC and GC was explored as a means of providing accurate film dosimetry for high doses. The DC compound method was evaluated at various dose distributions using EBT3 film inserted in a solid-water phantom. Measurements with $10{\times}20cm^2$ radiation field and $60^{\circ}$ dynamic-wedge were done. Dose distributions acquired using the RC and GC were analyzed with root-mean-squares-error (RMSE) and gamma analyses. The DC compound method was used based on the RC after correcting the GC for high doses in the gamma analysis. The RC and GC produced comparatively more accurate RMSE values for low and high doses, respectively. Gamma passing rates with an acceptance criterion of 3%/3 mm revealed that the RC provided rapid reduction in the high dose region, while the GC displayed a gradual decrease. In the whole dose range, the DC compound method had the highest agreement (93%) compared with single channel method using either the RC (80%) or GC (85%). The findings indicate that the use of DC compound method is more appropriate in dosimetric quality assurance for radiotherapy using high doses.

Spatial Selectivity Estimation using Cumulative Wavelet Histograms (누적밀도 웨이블릿 히스토그램을 이용한 공간 선택율 추정)

  • Chi, Jeong-Hee;Jeong, Jae-Hyuk;Ryu, Keun-Ho
    • Journal of KIISE:Databases
    • /
    • v.32 no.5
    • /
    • pp.547-557
    • /
    • 2005
  • The purpose of selectivity estimation is to maintain the summary data in a very small memory space and to minimize the error of estimated value and query result. In case of estimating selectivity for large spatial data, the existing works need summary information which reflect spatial data distribution well to get the exact result for query. In order to get such summary information, they require a much memory space. Therefore In this paper, we propose a new technique cumulative density wavelet Histogram, called CDW Histogram, which gets a high accurate selectivity in small memory space. The proposed method is to utilize the sub-histograms created by CD histogram. The each sub-histograms are used to generate the wavelet summary information by applying the wavelet transform. This fact gives us good selectivity even if the memory sire is very small. The experimental results show that the proposed method simultaneously takes full advantage of their strong points - gets a good selectivity using the previous histogram in ($25\%\~50\%$) memory space and is superior to the existing selectivity estimation techniques. The proposed technique can be used to accurately quantify the selectivity of the spatial range query in databases which have very restrictive memory.

The development of asynchronous ranging scheme based on the virtual slot (가상슬롯 기반의 비동기 거리 추정 기법 개발)

  • Ko, Young-Wook;Kim, Hwan-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.31-37
    • /
    • 2016
  • Ranging is divided into a synchronous scheme and an asynchronous scheme according to the presence of global synchronization between nodes. In general, the asynchronous ranging is preferred over synchronous ranging because it does not require an expensive high-precision oscillator for the global synchronization. On the other hand, in a conventional asynchronous ranging scheme, the packets, which are generated by all nodes in a positioning system of a large-scale infrastructure and need to be sent for localization by reference nodes, are considerable, which cause an increase in network traffic as the number of nodes increases. The traffic congestion lowers the throughput of the network leading to a considerable loss of energy. To solve this problem, this paper proposes a ranging scheme, in which virtual transmission slots randomly and discretely selected by a plurality of nodes are used to reduce the overheads needed in synchronizing the nodes, and the ranging is performed asynchronously based on the virtual transmission slots, thereby decreasing the network traffic. In addition, a performance test proved that the proposed ranging scheme was stronger than the TWR and SDS-TWR on an error range, even though the intensity of traffic was very low.

Measurement of Rainfall using Sensor Signal Generated from Vehicle Rain Sensor (차량용 레인센서에서 생성된 센서시그널을 이용한 강우량 측정)

  • Kim, Young Gon;Lee, Suk Ho;Kim, Byung Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.2
    • /
    • pp.227-235
    • /
    • 2018
  • In this study, we developed a relational formula for observing high - resolution rainfall using vehicle rain sensor. The vehicle rain sensor consists of eight channels. Each channel generates a sensor signal by detecting the amount of rainfall on the windshield of the vehicle when rainfall occurs. The higher the rainfall, the lower the sensor signal is. Using these characteristics of the sensor signal generated by the rain sensor, we developed a relational expression. In order to generate specific rainfall, an artificial rainfall generator was constructed and the change of the sensor signal according to the variation of the rainfall amount in the artificial rainfall generator was analyzed. Among them, the optimal sensor channel which reflects various rainfall amounts through the sensitivity analysis was selected. The sensor signal was generated in 5 minutes using the selected channel and the representative values of the generated 5 - minute sensor signals were set as the average, 25th, 50th, and 75th quartiles. The calculated rainfall values were applied to the actual rainfall data using the constructed relational equation and the calculated rainfall amount was compared with the rainfall values observed at the rainfall station. Although the reliability of the relational expression was somewhat lower than that of the data of the verification result data, it was judged that the experimental data of the residual range was insufficient. The rainfall value was calculated by applying the developed relation to the actual rainfall, and compared with the rainfall value generated by the ground rainfall observation instrument observed at the same time to verify the reliability. As a result, the rain sensor showed a fine rainfall of less than 0.5 mm And the average observation error was 0.36mm.

Surficial Sediment Classification using Backscattered Amplitude Imagery of Multibeam Echo Sounder(300 kHz) (다중빔 음향 탐사시스템(300 kHz)의 후방산란 자료를 이용한 해저면 퇴적상 분류에 관한 연구)

  • Park, Yo-Sup;Lee, Sin-Je;Seo, Won-Jin;Gong, Gee-Soo;Han, Hyuk-Soo;Park, Soo-Chul
    • Economic and Environmental Geology
    • /
    • v.41 no.6
    • /
    • pp.747-761
    • /
    • 2008
  • In order to experiment the acoustic remote classification of seabed sediment, we achieved ground-truth data(i.e. video and grab samples, etc.) and developed post-processing for automatic classification procedure on the basis of 300 kHz MultiBeam Echo Sounder(MBES) backscattering data, which was acquired using KONGBERG Simrad EM3000 at Sock-Cho Port, East Sea of South Korea. Sonar signal and its classification performance were identified with geo-referenced video imagery with the aid of GIS (Geographic Information System). The depth range of research site was from 5 m to 22.7 m, and the backscattering amplitude showed from -36dB to -15dB. The mean grain sizes of sediment from equi-distanced sampling site(50 m interval) varied from 2.86$(\phi)$ to 0.88(\phi). To acquire the main feature for the seabed classification from backscattering amplitude of MBES, we evaluated the correlation factors between the backscattering amplitude and properties of sediment samples. The performance of seabed remote classification proposed was evaluated with comparing the correlation of human expert segmentation to automatic algorithm results. The cross-model perception error ratio on automatic classification algorithm shows 8.95% at rocky bottoms, and 2.06% at the area representing low mean grain size.

Application of the Onsite EEW Technology Using the P-Wave of Seismic Records in Korea (국내 지진관측기록의 P파를 이용한 지진현장경보기술 적용)

  • Lee, HoJun;Jeon, Inchan;Seo, JeongBeom;Lee, JinKoo
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.133-143
    • /
    • 2020
  • Purpose: This study aims to derive a predictive empirical equation for PGV prediction from P-wave using earthquake records in Korea and to verify the reliability of Onsite EEW. Method: The noise of P wave is removed from the observations of 627 seismic events in Korea to derive an empirical equation with PGV on the base rock, and reliability of Onsite alarms is verified from comparing PGV's predictions and observations through simulation using the empirical equation. Result: P-waves were extracted using the Filter Picker from earthquake observation records that eliminated noises, a linear regression with PGV was used to derive a predictive empirical equation for Onsite EEW. Through the on-site warning simulation we could get a success rate of 80% within the MMI±1 error range above MMI IV or higher. Conclusion: Through this study, the design feasibility and performance of Onsite EEWS using domestic earthquake records were verified. In order to increase validity, additional medium-sized seismic observations from abroad are required, the mis-detection of P waves is controlled, and the effect of seismic amplification on the surface is required.

A polymer pH-Selectrode Based on Tribenzylamine as Neutral Carrier (Tribenzylamine 중성운반체를 이용한 pH-선택성 고분자 막전극)

  • Park, Myon-Young;Chung, Koo-Chun;Cho, Dong-Hoe;Lee, Kyeong-Jae;Jeong, Seong-Suk;Park, Sun-Young;Kim, Tae-Hun
    • Analytical Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.63-68
    • /
    • 1995
  • For the preparation of pH-selectrode, tribenzylamine, polyvinylchloride, dioctylphthalate, sodium tetraphenylborate and tetrahydrofuran were mixed with 0.02, 0.62, 1.34, 0.02g and 10ml respectively, and added 1g of acetylene black, graphite, silicon carbide or tungsten carbide respectively to improve electric conductivity. The selectrodes of seven kinds were shown linear to hydrogen ion in the range of pH 2 and 9. The best electric conductor for preparation of pH-selectrode based on tribenzylamine as neutral carrier was acetylene black and responded potential of the selectrode to hydrogen ion was shown the values near to theoretical Nernstian slope at $20^{\circ}C$. The interfering effects of the selectrode on hydrogen ion in the presence of alkali and alkaline earth metal ions were shown the better results with less error than glass electrode. The reproducibility and stability were good for use as a selectrode, especially in the presence of fluoride ion.

  • PDF

The Computerized Measurement for the Radiological Severity of Hallux Valgus (무지 외반증의 중증도에 대한 전산화 영상 계측)

  • Kang, Chang-Nam;Choi, Kyung-Jin;Lee, Doo-Yeon;Kim, Sang-Duk;Sung, Il-Hoon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • Purpose: To study the reliability of intra- and interobserver reliability in angular measurement of hallux valgus deformity by assessing hallux valgus angle (HVA) and the 1st to 2nd intermetatarsal angle (1-2 IMA) through using computerized system. Materials and Methods: 20 cases of moderate to severe hallux valgus patients were included in this study. With the standing anteroposterior view of foot, the HVA and 1-2 IMA were calculated by computerized measurement system of Infinity cooperation, called ${\pi}$-view, with its software tools. Using the statistical software program, SPSS (version 12th), we interpreted the results which were measured by two independent observers. Results: In the intraobserver measurement, the HVA of observer A showed reliability ($32.5^{\circ}{\pm}6.9$ and $33.1^{\circ}{\pm}6.8$)(p<0.05). 1-2 IMA in observer A was not regarded as reliable ($16.9^{\circ}{\pm}2.8$ and $17.1^{\circ}{\pm}2.8$)(p>0.05). In the results of observer B, HVAs were measured as $35.7^{\circ}{\pm}7.6$ and $36.2^{\circ}{\pm}7.7$, and were not reliable (p>0.05). 1-2 IMA in observer B was not reliable as well ($17.0^{\circ}{\pm}0.8$ and $20.8^{\circ}{\pm}1.5$)(p>0.05). In the interobservers' measurements, the first and the second results of HVA were $3.2^{\circ}{\pm}3.6$ and $3.1^{\circ}{\pm}3.1$, reliable within the 95% confidence interval (p<0.05). 1-2 IMAs were $0.1^{\circ}{\pm}1.9$ and $3.73^{\circ}{\pm}1.3$, which were not reliable (p>0.05). Conclusion: In the angular measurement of the hallux valgus by computerized system, the HVA and 1-2 IMA showed less error range in the interobserver's results, compared with the previous studies about the manual measurement. However, our results failed to show the statistical reliability of intra- and interobserver's measuring. Therefore, even the computerized angular measurements in the severity of hallux valgus require development of the measuring methods and software tools.

  • PDF