• Title/Summary/Keyword: error range

Search Result 2,811, Processing Time 0.03 seconds

Dynamic analysis of a cage affected by the current (조류의 영향을 바든 가두리의 거동해석)

  • Lee, Mi-Kyung;Lee, Chun-Woo
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.40 no.3
    • /
    • pp.214-224
    • /
    • 2004
  • A large cage system for the purpose of fishes farming in the open sea was influenced by various forces from the ocean environment. The deformation of the cage by these forces affects the safety of the cage itself, as well as that of the cultivated creatures. In this research, theoretical model was established to analyzing dynamic movement influenced by current for cage. Also, to increase the accuracy of calculations, the reduction ratio of flow speed acquired using the flume tank experiment. Applying the reduction ratio of flow speed to the numerical calculation, the calculation values were compared with the measured values in the flume tank experiment using cage model. The results were as follows ; 1. When the flow speed of the flume tank is fixed, the decrease of the velocity of flow which is passed the upper panel side is proportion to the increase of porosity ratio of netting. 2. When the porosity ratio is fixed, the increase of the velocity of flow which is passed the upper panel side is proportion to the increase of velocity of flow. 3. When the porosity ratio and the flow speed of the flume tank are fixed, the decrease of the velocity of flow which is passed the upper panel side is proportion to the increase of attack angle. 4. As a result of comparison between the underwater shape by simulation which is applying the reduction ratio of flow speed from the experiment using plane netting and that by model experiment, it was found out that the result of the simulation was very close to that of model gear within ${\pm}$ 5 % error range.

Antioxidant Activities and Quality Characteristics of Fermented Codonopsis lanceolata Tea according to Heating Processes (발효한 더덕 차의 열처리에 의한 항산화 활성 및 품질특성)

  • Lee, Ji Yeon;Kim, Byung Keuk;Park, Hong Je
    • The Korean Journal of Food And Nutrition
    • /
    • v.26 no.4
    • /
    • pp.693-699
    • /
    • 2013
  • This study examines the antioxidant activities and quality characteristics of fermented Codonopsis lanceolata tea according to the heating temperature and time. The browning, turbidity, reducing sugar, total polyphenol and total flavonoid contents all increased with increasing of heating temperature and time, but the pH decreased within the range of error. In particular, the total polyphenol contents of the heat treatment sample for 15 minutes at $200^{\circ}C$ are increased to about 4.5 times of 713.71mg/100ml as compared to the control group. From the results of the antioxidant activity test, as both the heating temperature and time increases, the antioxidant activity was increased for DPPH radical-scavenging activity, FRAP and reducing its power. In the case of the samples treated with heat for 15 minutes at $200^{\circ}C$ in the DPPH radical scavenging ability, it increased about twice more than the 45.17% control plot at 85.40%, and the reducing power and FRAP were increased to approximately two or three times more than the control group. According to the results for sensory test of fermented C. lanceolata tea according to heating temperature and time, the preference was confirmed as high by heat treatment due to increased temperature and time. Heat treatment process of C. lanceolata during the process is determined by the conditions required for high value-added products through the improvements of the taste and functionality of C. lanceolata.

A Signal Readout System for CNT Sensor Arrays (CNT 센서 어레이를 위한 신호 검출 시스템)

  • Shin, Young-San;Wee, Jae-Kyung;Song, In-Chae
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.9
    • /
    • pp.31-39
    • /
    • 2011
  • In this paper, we propose a signal readout system with small area and low power consumption for CNT sensor arrays. The proposed system consists of signal readout circuitry, a digital controller, and UART I/O. The key components of the signal readout circuitry are 64 transimpedance amplifiers (TIA) and SAR-ADC with 11-bit resolution. The TIA adopts an active input current mirror (AICM) for voltage biasing and current amplification of a sensor. The proposed architecture can reduce area and power without sampling rate degradation because the 64 TIAs share a variable gain amplifier (VGA) which needs large area and high power due to resistive feedback. In addition, the SAR-ADC is designed for low power with modified algorithm where the operation of the lower bits can be skipped according to an input voltage level. The operation of ADC is controlled by a digital controller based on UART protocol. The data of ADC can be monitored on a computer terminal. The signal readout circuitry was designed with 0.13${\mu}m$ CMOS technology. It occupies the area of 0.173 $mm^2$ and consumes 77.06${\mu}W$ at the conversion rate of 640 samples/s. According to measurement, the linearity error is under 5.3% in the input sensing current range of 10nA - 10${\mu}A$. The UART I/O and the digital controller were designed with 0.18${\mu}m$ CMOS technology and their area is 0.251 $mm^2$.

A UHF-band Passive Temperature Sensor Tag Chip Fabricated in $0.18-{\mu}m$ CMOS Process ($0.18-{\mu}m$ CMOS 공정으로 제작된 UHF 대역 수동형 온도 센서 태그 칩)

  • Pham, Duy-Dong;Hwang, Sang-Kyun;Chung, Jin-Yong;Lee, Jong-Wook
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.10
    • /
    • pp.45-52
    • /
    • 2008
  • We investigated the design of an RF-powered, wireless temperature sensor tag chip using $0.18-{\mu}m$ CMOS technology. The transponder generates its own power supply from small incident RF signal using Schottky diodes in voltage multiplier. Ambient temperature is measured using a new low-power temperature-to-voltage converter, and an 8-bit single-slope ADC converts the measured voltage to digital data. ASK demodulator and digital control are combined to identify unique transponder (ID) sent by base station for multi-transponder applications. The measurement of the temperature sensor tag chip showed a resolution of $0.64^{\circ}C/LSB$ in the range from $20^{\circ}C$ to $100^{\circ}C$, which is suitable for environmental temperature monitoring. The chip size is $1.1{\times}0.34mm^2$, and operates at clock frequency of 100 kHz while consuming $64{\mu}W$ power. The temperature sensor required a -11 dBm RF input power, supported a conversion rate of 12.5 k-samples/sec, and a maximum error of $0.5^{\circ}C$.

Effect of frequency dependent multipath fading on non-coherent underwater communication system (주파수 종속 다중경로 페이딩이 비코히어런트 수중통신시스템에 미치는 영향)

  • Kim, Jongjoo;Park, Jihyun;Bae, Minja;Park, Kyu-Chil;Yoon, Jong Rak
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.4
    • /
    • pp.295-302
    • /
    • 2016
  • Underwater acoustic communication channel is often defined as a multipath fading channel since the multipath arrivals from various paths interfere with each other and cause frequency dependent constructive or destructive interference in received signals. Therefore signal-to-noise ratio (SNR) of received signal fluctuates as a function of frequency. In addition, sea surface fluctuation induces frequency dependent time variant signal fading due to coherent component variation of surface bounce path. The frequency shift keying (FSK) system is known to be less sensitive and more robust under these interference and fading, and M-ary frequency shift keying (MFSK) system is adopted to increase a data rate. In this study, a bit error rate (BER) of 4 channels 4FSK system are examined in shallow sea multipath channel. Experimental results show that RS code reduces efficiently the BER of 4FSK system since frequency dependent time-varying fading is characterized to give burst errors. The BER of a different data rate or different source-to-receiver range depends on not only the channel coherent bandwidth but also frequency dependent multipath fading.

Moral Reasoning and Ethical Decision Making among Student Nurses in Moral Dilemmas (간호학생의 도덕적 사고와 윤리적 딜레마 상황에서의 의사결정)

  • Han, Sung-Suk;Ahn, Sung-Hee
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.1 no.1
    • /
    • pp.5-21
    • /
    • 1995
  • This study purports to investigate moral reasoning and ethical decision making among student nurses in the hypothetical moral dilemmas. The subjects consisted of 25 senior nursing students attending at a four-year college. Data were collected through self-reported questionnaires in November, 1993. The questionnaires included two kinds of tests. Rest's Defining Issues Test was adopted to measure the stage of moral development, which was classified with the stage 2 (instrumental relativist orientation), the stage 3 (interpersonal concordance), the stage 4 (law and order), the stage 5A (societal consensus), and the stage 5B (intuitional humanism). In particular, the level of principled thinking (P) was measured by summing those scores of the stages 5A, 5B, and 6. The possible range of P is 0 to 95. As for measuring the levels of morality and nursing dilemma, Crisham's Nursing Dilemma Test was adopted. This test generated the morality score(MS) and the dilemma score (DS). The data were analyzed by t-test, ANOVA, Kruskal-Wallis test, and Pearson correlation coefficients. The findings are following. 1. The mean score of P was 52.93 (SD=12.82). The mean score of the stage 5A was significantly higher than the scores of other stages (17.92, p=.0001). 2. The mean score of P was not significantly different by general characteristics of the students. Of the scores of each stage, only the mean score of the stage 3 revealed significant difference by the status of living with parents(p=.0283). The score was highest when "living with both parents"(15.22), which was followed by "living with no parents"(10.0), "living with father only"(9.0), and "living with mother only"(7.50). 3. With regard to the five dilemmas postulated such as forcing medication, performing cardiac pulmonary resuscitation, reporting a medication error, informing diagnosis to terminally ill adult, and providing new-nurse orientation, most students perceived them as moral dilemma rather than nonmoral one. Most students made a positive decision according to moral reasoning in the above situations except for providing new-nurse orientation. 4. The mean score of the MS was 3.30 and that of the DS was 3.32. These scores did not show significant difference with general characteristics of the students. 5. As for the correlations between moral reasoning and decision making, the score of the stage 5A was positively correlated with the scores of P(.74, p<.0001) and DS(.56, p<.001). Positive correlation was also observed between the scores of stage 2 and stage 4(.68, p<.0001). On the other hand, the score of P was negatively correlated with the scores of stage 3(-.47, p<.05) and of stage 4(-.55, p<.001). The score of the stage 5A was also negatively correlated with the score of the stage 6(-.42, p<.05).

  • PDF

The Trend of Korean Nursing Research with the LISREL (공변량 구조분석을 이용한 국내 간호연구의 동향)

  • 임난영;강현숙;이성은;서연옥;권영은
    • Journal of Korean Academy of Nursing
    • /
    • v.31 no.2
    • /
    • pp.221-231
    • /
    • 2001
  • This study was conducted by analyzing all 33 articles based on the LISREL, published from January 1991 to March 1999 in Korea. The analyses consisted of the publication date of articles, principal dependent variables, subjects of the research, adequacy of sampling, adequacy of research purposes and results, accordance between theoretical model and hypothetical model, fit measures, theoretical base of model modification, and adequacy of conclusion. The results were as follows : . The thesis of 33 articles in total were outnumbered as 25 (75.8%) to 8 (24.2%) research articles. As for a sex classification of the subjects, 45.5% of the research were conducted around a female group of subjects, while 54.5% were done for both sex, The range of the sample size was 105 to 803, and the average was 259 subjects. . A single theoretical variable was measured for each measurement variable, any difference between variables was hardly found in 8 articles (24.2%), and 19 articles (57.6%) did not consider any measurement error. To analyze if the representative has been articles (21.2%) were seen with a sign of a representative. Questionnaires were used in a majority (31 articles) of the data collecting process. Only 2 articles (6.1%) were measured with a physiologic index simultaneously. . 14 articles (42.2%) were centered on theory development, 10 articles on theory synthesis, and 9 articles on theory test. The research purposes and results were consistent in 25 articles (75.5%) and 8 articles (24.2%) were inconsistent. The quality of life and health promotion behavior were the concepts most frequently studied as a dependent variable, and 7 articles centered on them. In applied theories a health promotion model was used on 4 articles (12.1%), while role theory and stress-coping models were in 3 articles respectively. . The articles were analyzed to see if the hypothetical model was elaborated and tested by the theoretical model. Twenty-five articles proved to be rationale for the inconsistencies. Also, 56.5% proposed hypotheses were supported among the subject articles, and 30 articles (90.0%) suggested a revised model. Path coefficient (17 articles) and theoretical adequacy (17 articles) were the standards mostly used. In conclusion, the principal factors were obtained from the research are to be considered as the principes of LISREL application. First, a model has to be established on a theoretical base rather than empirical results dependent on the data. The results are also required to be globally interpreted. Secondly, at least 200 samples are necessary to satisfy the need. Third, more than 3 measurement variables are to be adjusted to a single theoretical variable; the measurement errors must be suggested as well. Finally, normal distribution characteristics of the data and the estimation method need to be reported. Based on the research result, the follows are suggested; . Systematic criteria on the LISREL application and procedure need to be developed . Agreement form is required to report the results of research using the LISREL

  • PDF

Evaluation of imaging reformation for root and pulp canal shapes of permanent teeth using a cone beam computed tomography (Cone beam형 전산화단층영상을 이용한 영구치 치근과 근관의 형태 평가)

  • Hong, Jong-Hyun;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.37 no.3
    • /
    • pp.165-170
    • /
    • 2007
  • Purpose: To estimate the shape of root and pulp canal using a dental cone beam computed tomography (CBCT) and to evaluate the accuracy of imaging reformation. Materials and Methods: CBCT images were obtained with incisors, premolars, and molars as the destination by using PSR $9000N^{TM}$ Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) and i-CAT (Imaging Sciences International, Inc, USA) cone beam CT unit that have different kind of detector and field of view, and compared these with the shape and the size of actual root and root canal. Results: When the measuring value of cone beam computed tomography concerning to each root's bucco-lingual diameter and mesio-distal diameter was compared with the value of the actual root, it reveals an error range $-0.49{\sim}+0.63$ mm at PSR900N and $-0.97{\sim}+1.14$ mm at i-CAT (P>0.05). It was possible to identify and measure PSR$9000N^{TM}$ Dental CT system to the limit $0.48{\pm}0.06mm$ (P>0.05) and i-CAT CBCT to the limit $0.86{\pm}0.09mm$ (P<0.05) on estimating the size and the shape of root canal. Two kinds of CBCT images revealed the useful reproducibility to estimate the shape of root, but there was the difference to estimate the shape of root according to apparatus. The reproducibility of root shape in the image of three-dimensions at PSR 900N is low such as 0.65 mm in a case of minute root canal. Conclusions: CBCT images revealed higher accuracy of the imaging reformation for root and pulp and clinically CBCT is a useful diagnostic tool for the assessment of root and canal. However, there are different qualities of imaging reformation according to CBCT apparatus and limitation of reproducibility for minute root canals.

  • PDF

Accuracy of linear measurement using cone-beam computed tomography at different reconstruction angles

  • Nikneshan, Sima;Aval, Shadi Hamidi;Bakhshalian, Neema;Shahab, Shahriyar;Mohammadpour, Mahdis;Sarikhani, Soodeh
    • Imaging Science in Dentistry
    • /
    • v.44 no.4
    • /
    • pp.257-262
    • /
    • 2014
  • Purpose: This study was performed to evaluate the effect of changing the orientation of a reconstructed image on the accuracy of linear measurements using cone-beam computed tomography (CBCT). Materials and Methods: Forty-two titanium pins were inserted in seven dry sheep mandibles. The length of these pins was measured using a digital caliper with readability of 0.01 mm. Mandibles were radiographed using a CBCT device. When the CBCT images were reconstructed, the orientation of slices was adjusted to parallel (i.e., $0^{\circ}$), $+10^{\circ}$, $+12^{\circ}$, $-12^{\circ}$, and $-10^{\circ}$ with respect to the occlusal plane. The length of the pins was measured by three radiologists, and the accuracy of these measurements was reported using descriptive statistics and one-way analysis of variance (ANOVA); p<0.05 was considered statistically significant. Results: The differences in radiographic measurements ranged from -0.64 to +0.06 at the orientation of $-12^{\circ}$, -0.66 to -0.11 at $-10^{\circ}$, -0.51 to +0.19 at $0^{\circ}$, -0.64 to +0.08 at $+10^{\circ}$, and -0.64 to +0.1 at $+12^{\circ}$. The mean absolute values of the errors were greater at negative orientations than at the parallel position or at positive orientations. The observers underestimated most of the variables by 0.5-0.1 mm (83.6%). In the second set of observations, the reproducibility at all orientations was greater than 0.9. Conclusion: Changing the slice orientation in the range of $-12^{\circ}$ to $+12^{\circ}$ reduced the accuracy of linear measurements obtained using CBCT. However, the error value was smaller than 0.5 mm and was, therefore, clinically acceptable.

A Study on the Performance Improvement of Turbo Coded OFDM Systems Considering Frequency Offset (주파수 오프셋을 고려한 Tued OFDM 시스템의 성능 개선에 관한 연구)

  • 이영춘;박기식
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.5
    • /
    • pp.908-915
    • /
    • 2001
  • In this paper, it is analyzed theoretically that the performance degradation, caused by carrier frequency offset, in an OFDM/M-ary PSK system. Then, when Turbo coding is adopted to an OFDM/M-ary PSK system, the degree of performance enhancement is evaluated. Finally, the maximum frequency offset is calculated to satisfy the BER performance required in a Turbo coded OFDM/M-ary PSK system. As results of analysis, it is shown that the more the number of M-ary is, the worse the BER performance is. Moreover, 7dB, 9dB, and 17dB of $E_b/N_o$ are required in QPSK, 8PSK and 16PSK systems, respectively in order to satisfy the error performance, $BER=10^{-3}$ for voice communication. If $E_b/N_o$ are 10㏈ and 15㏈, the frequency offset should be below 0.05 and 0.075, respectively, for voice communication. When Turbo coding is adopted to an OFDM/M-ary PSK system, the less the number of M-ary is, the greater the performance enhancement of Turbo coding is. If the number of a M-ary system of the system is below 16, it is found that required $E_b/N_o$ is about 8dB to satisfy $BER=10^{-5}$ Moreover, in the system the Turbo coding scheme, voice communication is available with greatly low$E_b/N_o$, and 8dB of $E_b/N_o$ is enough for data communication regardless of the permission range of frequency offset.

  • PDF