• Title/Summary/Keyword: error range

Search Result 2,816, Processing Time 0.029 seconds

A Study for the Horizontal Induced Phoria in Spectacles Wearers (안경 장용자의 수평 유발 사위에 관한 연구)

  • Sung, Duk Yong;Lee, Won Jin;Kang, Sung Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.2
    • /
    • pp.85-91
    • /
    • 1996
  • Among the 110 glasses wearers, the hyperopic glasses wearers were 18(16.36%) persons and myopic glasses wearers were 92(83.64%) persons. The distance for optical centers was coincided to the pupillary distance in 9(8.18%) persons and discrepant in 101(91.82%) persons. Ophthalmic dispensing Pupillary Distance resulted from testing by the trouble error range(Germany RAL-915), unadopt spectacles had been wearers 52(51.49%) persons. The 65(64.56%) persons and 36(35.64%) persons showed the induced esophoria and the induced exophria, respectively. The maximal induced esophoria was 3.69 prism diopters and maximal induced exophoria was 3.68 prism diopters.

  • PDF

Precise Orbit Estimation of GPS using GIPSY-OASIS (GIPSY-OASIS기반 GPS 정밀 궤도 추정)

  • Ha, Jihyun;Chun, Sebum;Park, Kwan-Dong
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.6
    • /
    • pp.535-541
    • /
    • 2019
  • In this paper, scripts for estimating the reference orbits of navigation satellites were developed and their performance was analyzed as a preliminary study for the development of the Korean GPS precise orbit determination technology. The JPL Flinn AC's data processing strategy was applied and Linux-based scripts were developed using GIPSY-OASIS. For the analysis of the accuracy of the estimated reference orbit, the precise orbit provided by the international GNSS data center was used as the truth. As a result, estimated satellite coordinates showed almost exactly same patterns and trends with the reference precise orbits, and their differences are in the range of ±2 cm. The average error between the two orbits was less than 1 cm in the 3D direction, while the standard deviation was also at 1 cm. From these, we found that the developed scripts have excellent performance in precise orbit determination.

Implementation of Telemetry System using Scatternet in Bluetooth Technology (블루투스의 스캐터넷과 임베디드 시스템을 이용한 텔레메트리 시스템의 구현)

  • 김종현;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.941-944
    • /
    • 2003
  • This paper implement Telemetry System which is used Bluetooth. This System propose system which can detect a total amount of gas, electricity or water without a motorman, at home. BlueTooth is a close range wireless communication technology which uses a wireless frequency 2.4GHz and has a high trust and self - error correction technology according to a low power consumption quality and a high-speed frequency hopping. This makes get a high trust concerning a data transmission than an existing modem. In addition, though wireless modem is restricted by a minimal of a wireless terminal, it will be possible to coincide with the function of the portable with the low power consumption quality by using Bluetooth. And as the system on a chip of module progresses, the possibility of the snail size is present. And, Motorman who use mobility of embedded system can detect detect a total amount of gas, electricity or water outdoor. Embedded system use ARM processor that is low power processor. So it ran use long time efficiently.

  • PDF

Performance Analysis of OFDM-DSRC System Using LMMSE Equalization Technique (LMMSE 등화기법을 적용한 OFDM-DSRC 시스템의 성능분석)

  • Sung Tae-Kyung;Kim Soon-Young;Rhee Myung-Soo;Cho Hyung-Rae
    • Journal of Navigation and Port Research
    • /
    • v.29 no.1 s.97
    • /
    • pp.23-28
    • /
    • 2005
  • The signal in wireless multi-path channel is affected by fading and ISI because of high data rate transmission, so the signal has the high error rate. The present modulation and demodulation method of DSRC system can not expect sufficient for providing data service over 1 Mbps, so the channel equalization and advanced modulation and demodulation methods are required. OFDM is generally known as an effective technique for high data rate transmission system, since it can prevent ISI by inserting a guard interval. However, a guard interval longer than channel delay spread has to be used in each OFDM symbol period, thus resulting a considerable loss in the efficiency of channel utilization Therefore the equalizer is necessary to cancel ISI to accommodate advanced ITS service with higher bit rate and longer channel delay spread condition In this paper, the channel equalizer for the OFDM -DSRC system was designed and its performance in a multi-path fading environment was evaluated with computer simulation.

Design of Filter to Remove Motionartifacts of Photoplethysmography Based on Indepenent Components Analysis and Filter Banks (독립성분 분석법과 필터뱅크를 기반한 PPG 신호의 동잡음제거 필터 설계)

  • Lee, Ju-won;Lee, Byeong-ro
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.8
    • /
    • pp.1431-1437
    • /
    • 2016
  • In mobile healthcare device, when to measure the heart rate by using the PPG signal, its performance is reduced according to the motion artifacts that is the movement of user. This is because the frequency range of motion (0.01-10 Hz) and that of PPG signals overlap. Also, the motion artifacts cannot be rectified by general filters. To solve the problem, this paper proposes a method using filter banks and independent component analysis (ICA). To evaluate the performance of the proposed method, we were artificially applied various movements and compared heart rate errors of the moving average filter and ICA. In the experimental results, heart rate error of the proposed method showed very low than moving average filter and ICA. In this way, it is possible to measure stable heart rate if the proposed method is applied to the healthcare terminal design.

Pharmacogenomics of Depressive Disorders (우울증의 약물유전체학)

  • Ham, Byung-Joo;Lee, Min-Soo
    • Korean Journal of Biological Psychiatry
    • /
    • v.8 no.2
    • /
    • pp.226-232
    • /
    • 2001
  • The pharmacotherapy of depression has reduced morbidity and improved outcome for many depressive patients. A wide range of classical and new antidepressants are available for their treatment. However, 30-40% of all patients do not respond sufficiently to the initial treatment and present adverse effects. Pharmacogenetics studies the genetic basis of an individual's ability to respond to pharmacotherapy. Recently, some reports on serotonin transporter gene polymorphisms and their influence on the response to antidepressive therapy provide an interesting diagnostic tool in assessing the chances of response to antidepressants. We also investigated the relationship between serotonin transprter polymorphisms(5-HTTLPR) and the long-term effect of the antidepressant treatment. 128 depressive patients were enrolled into 2nd year study. The therapeutic response of each subset was not different at 8th, 16th week, but the subset with homozygote(l/l) of long variant showed a better therapeutic response to antidepressant than the heterozygote(l/s) of long and short variant, which showed a better therapeutic response than the subset with homozygote (s/s) of short variant at 1st year and 2nd year after the antidepressant treatment. This result shows that the serotonin transporter polymorphisms may be related to the long-term effect of antidepressant treatment. The potential for pharmacogenomics, the use of genetic information to guide pharmacotherapy and improve outcome by providing individualized treatment decisions, has gained increasing attention. pharmacogenomics will contribute to individualize drug choice by using genotype to predict positive clinical outcomes, adverse reactions, and levels of drug metabolism. Personalized medicine, the use of marker-assisted diagnosis and targeted therapies derived from an individual molecular profile, will impact the antidepressant therapy and this approach will replace the traditional trial-and-error practice of medicine.

  • PDF

A Study on the Heat Release Analysis to Compensate the Error due to Assumption of Single Zone in Diesel Engine (디젤 기관 단일 영역 모델 열발생율 계산의 오차 보상에 관한 연구)

  • Ryu Seung-Hyup;Kim Ki-Doo;Yoon Wook-Hyeon;Ha Ji-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.5
    • /
    • pp.572-579
    • /
    • 2006
  • Accurate heat release analysis based on the cylinder pressure trace is important for evaluating combustion process of diesel engines. However, traditional single-zone heat release models (SZM) have significant limitations due mainly to their simplified assumptions of uniform charge and homogeneity while neglecting local temperature distribution inside cylinder during combustion process. In this study, a heat release analysis based on single-zone model has been evaluated by comparison with computational simulation result using Fire-code, which is based on multidimensional model (MDM). The limitations of the single-zone assumption have been estimated, To overcome these limitations, an improved model that includes the effects of spatial non-uniformity has been applied. From this improved single-zone heat release model (Improved-SZM), two effective values of specific heat ratios, denoted by ${\gamma}_V$ and ${\gamma}_H$ in this study, have been introduced. These values are formulated as the function of charge temperature changing rate and overall equivalence ratio. Also, it is applied that each equation of ${\gamma}_V$ and ${\gamma}_H$ has respectively different slopes according to several meaningful periods during combustion progress. The heat release analysis results based on improved single-zone model gives a good agreement with FIRE-code results over the whole range of operating conditions of target engine, Hyundai HiMSEN H21/32.

Removal of Edge Artifact due to Pertial Volume Effect in the Adaptive Template Filtering (적응 템플릿 필터링에서 복셀의 부분 볼륨 효과로 인한 헤지 아티팩트의 제거)

  • 안창범;송영철
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.120-127
    • /
    • 2000
  • Adaptive template filtering has been proposed recently for enhancement of signal-to-noise ratio without loss of resolution. In the adaptive template filtering, an optimal template among multiple templates is selected, then linear least square error filtering based on the template is applied in vowel by vowel basis. In some magnetic resonance imaging, where the distribution of gray level has relatively small dynamic range, e.g., $T_1$ imaging, however, artificial stair-like artifact is observed at near edges. This is partially due to the edge enhancement effect in such yokels that contain multiple compounds at the boundaries of tissues. The gray levels of these yokels become similar gray levels of near dominant vowels that contain single compound by the adaptive filtering, which enlarges edge discontinuities. In this paper, we propose a technique to eliminate such artifact by identifying those yokels that contain multiple compounds and assigning the largest template for them. Filtered images with the proposed technique show substantial visual enhancement at the edges without degradation of peak signal-to-noise ratio compared to the original adaptive template filtering for both magnetic resonance images and phantom images.

  • PDF

A Study on the World Geodetic System Transformation of Cadastral Record Using by Three parameters (3변수를 이용한 지적공부의 세계측지계 변환 연구)

  • Jung, Wan-Suk;Kang, Sang-Gu
    • Journal of Cadastre & Land InformatiX
    • /
    • v.44 no.2
    • /
    • pp.139-153
    • /
    • 2014
  • The world geodetic system transformation of cadastral record have to minimize differences of boundary and area being in cadastral record according to transformation for that is direct connected with the land owner and property protection. However it is very difficult to accurately maintain the before and after transformation because coordinate transformation is generally using a mathematical conversion formula. At present, Helmert model by using 4-parameter is official coordinate transformation model for Cadastral Resurvey Project but scale factor is most sensitive to changes of area and relative position in the same parcel. In this study, it was proposed 3-parameter method using by scale factor fixing through the application of a Helmert in order to avoid changing the area difference and keeping the error within the tolerance range of the boundary which is related to the boundary point coordinate region.

Comparative Study on Microwave Probes for Plasma Density Measurement by FDTD Simulations

  • Kim, D.W.;You, S.J.;Na, B.K.;Kim, J.H.;Chang, H.Y.;Oh, W.Y.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.218.1-218.1
    • /
    • 2014
  • In order to measure the absolute plasma density, various probes are proposed and investigated and microwave probes are widely used for its advantages (Insensitivity to thin non-conducting material deposited by processing plasmas, High reliability, Simple process for determination of plasma density, no complicate assumptions and so forth). There are representative microwave probes such as the cutoff probe, the hairpin probe, the impedance probe, the absorption probe and the plasma transmission probe. These probes utilize the microwave interactions with the plasma-sheath and inserted structure (probe), but frequency range used by each probe and specific mechanisms for determining the plasma density for each probe are different. In the recent studies, behaviors of each microwave probe with respect to the plasma parameters of the plasma density, the pressure (the collision frequency), and the sheath width is abundant and reasonably investigated, whereas relative diagnostic characteristics of the probes by a comparative study is insufficient in spite of importance for comprehensive applications of the probes. However, experimental comparative study suffers from spatially different plasma characteristics in the same discharge chamber, a low-reproducibility of ignited plasma for an uncertainty in external discharge parameters (the power, the pressure, the flow rate and so forth), impossibility of independently control of the density, the pressure, and the sheath width as well as expensive and complicate experimental setup. In this paper, various microwave probes are simulated by finite-different time-domain simulation and the error between the input plasma density in FDTD simulations and the measured that by the unique microwave spectrums of each probe is obtained under possible conditions of plasma density, pressure, and sheath width for general low-temperature plasmas. This result shows that the each probe has an optimum applicable plasma condition and reliability of plasma density measurement using the microwave probes can be improved by the complementary use of each probe.

  • PDF