• Title/Summary/Keyword: error characteristics

Search Result 3,489, Processing Time 0.03 seconds

A CHARACTERISTICS-MIXED FINITE ELEMENT METHOD FOR BURGERS' EQUATION

  • Chen, Huanzhen;Jiang, Ziwen
    • Journal of applied mathematics & informatics
    • /
    • v.15 no.1_2
    • /
    • pp.29-51
    • /
    • 2004
  • In this paper, we propose a new mixed finite element method, called the characteristics-mixed method, for approximating the solution to Burgers' equation. This method is based upon a space-time variational form of Burgers' equation. The hyperbolic part of the equation is approximated along the characteristics in time and the diffusion part is approximated by a mixed finite element method of lowest order. The scheme is locally conservative since fluid is transported along the approximate characteristics on the discrete level and the test function can be piecewise constant. Our analysis show the new method approximate the scalar unknown and the vector flux optimally and simultaneously. We also show this scheme has much smaller time-truncation errors than those of standard methods. Numerical example is presented to show that the new scheme is easily implemented, shocks and boundary layers are handled with almost no oscillations. One of the contributions of the paper is to show how the optimal error estimates in $L^2(\Omega)$ are obtained which are much more difficult than in the standard finite element methods. These results seem to be new in the literature of finite element methods.

A Case Study of a Bilingual Child with SLI : The Role of Speech-Language Pathologist in Assessment and Treatment of Bilingual Children

  • Yim, Dong-Sun;Shin, Moon-Ja
    • Speech Sciences
    • /
    • v.8 no.1
    • /
    • pp.123-133
    • /
    • 2001
  • This case study investigated the assessment and treatment of bilingual children using a 4.5 year old bilingual child. We also compared treatment methods for bilingual children in the U.S. and in Korea, respectively. Given the lack of unbiased assessment tools, it was difficult to evaluate the child properly. In addition, the study of the linguistic characteristics of bilingual children have not been researched extensively in Korea. As a result, there were limitations in assessing the child. However, once all requisite information had been gathered, he was assessed as a bilingual child with specific language impairment (SLI) and his skill in both languages was considered equivalent. During treatment sessions, the child exhibited diverse linguistic characteristics and interesting error patterns which were not evident in monolingual SLI. However, it was difficult to assess whether the error patterns exhibited by the subject were attributable to his own bilingual characteristics or not. This was further complicated by the lack of previous research on the bilingual child's linguistic characteristics. His progress differed from one area to another. Furthermore, we illustrated some of the limitations in assessing bilingual children and proposed several considerations that should be met before treatment is initiated.

  • PDF

An Positioning Error Analysis of 3D Face Recognition Apparatus (3차원 안면자동인식기의 Positioning 오차분석)

  • Kwak, Chang-Kyu;Cho, Yong-Beum;Sohn, Eun-Hae;Yoo, Jung-Hee;Kho, Byung-Hee;Kim, Jong-Won;Kim, Kyu-Kon;Lee, Eui-Ju
    • Journal of Sasang Constitutional Medicine
    • /
    • v.18 no.2
    • /
    • pp.34-40
    • /
    • 2006
  • 1. Objectives We are going to develope 3D Face Recognition Apparatus to analyse the facial characteristics of the Sasangin. In the process, we should identify the recognition rate of the three dimensional position using this Apparatus. 2. Methods We took a photograph of calibrator($280{\times}400mm$) with interval of 20mm longitudinal direction of 10 times using 3D Face Recognition Apparatus. In the practice, we obtained 967 point to the exclusion of points deviating from the visual field of dual camera. And we made a comparison between measurement values and three dimensional standard values to calculate the errors. 3. Results and Conclusions In this test, the average error rate of X axis values was 0.019% and the maximum error rate of X axis values was 0.033%, the average error rate of Y axis values was 0.025% and the maximum error rate of Y axis values was 0.044%, the average error rate of Z axis values was 0.158% and the maximum error rate of Z axis values was 0.269%. This results exhibit much improvement upon the average error rate 1% and the maximum error rate 2.242% of the existing 3D Recognition Apparatus. In conclusion, we assessed that this apparatus was adaptable to abstract the facial characteristic point from three dimensional face shape in the mechanical aspects.

  • PDF

Context-sensitive Word Error Detection and Correction for Automatic Scoring System of English Writing (영작문 자동 채점 시스템을 위한 문맥 고려 단어 오류 검사기)

  • Choi, Yong Seok;Lee, Kong Joo
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.1
    • /
    • pp.45-56
    • /
    • 2015
  • In this paper, we present a method that can detect context-sensitive word errors and generate correction candidates. Spelling error detection is one of the most widespread research topics, however, the approach proposed in this paper is adjusted for an automated English scoring system. A common strategy in context-sensitive word error detection is using a pre-defined confusion set to generate correction candidates. We automatically generate a confusion set in order to consider the characteristics of sentences written by second-language learners. We define a word error that cannot be detected by a conventional grammar checker because of part-of-speech ambiguity, and propose how to detect the error and generate correction candidates for this kind of error. An experiment is performed on the English writings composed by junior-high school students whose mother tongue is Korean. The f1 value of the proposed method is 70.48%, which shows that our method is promising comparing to the current-state-of-the art.

An Hardware Error Analysis of 3D Automatic Face Recognition Apparatus(3D-AFRA) : Surface Reconstruction (3차원 안면자동인식기(3D-AFRA)의 Hardware 정밀도 검사 : 형상복원 오차분석)

  • Seok, Jae-Hwa;Song, Jung-Hoon;Kim, Hyun-Jin;Yoo, Jung-Hee;Kwak, Chang-Kyu;Lee, Jun-Hee;Kho, Byung-Hee;Kim, Jong-Won;Lee, Eui-Ju
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.2
    • /
    • pp.30-39
    • /
    • 2007
  • 1. Objectives The Face is an important standard for the classification of Sasang Constitution. We are developing 3D Automatic Face Recognition Apparatus(3D-AFRA) to analyse the facial characteristics. This apparatus show us 3D image and data of man's face and measure facial figure data. So we should examine the figure restoration error of 3D Automatic Fare Recognition Apparatus(3D-AFRA) in hardware Error Analysis. 2. Methods We scanned Face status by using 3D Automatic Face Recognition Apparatus(3D-AFRA). And also we scanned Face status by using laser scanner(vivid 9i). We compared facial shape data be restored by 3D Automatic Face Recognition Apparatus(3D-AFRA) with facial shape data that be restorated by 3D laser scanner. And we analysed the average error and the maximum error of two data. 3. Results and Conclusions In frontal face, the average error was 0.48mm. and the maximum error was 4.60mm. In whole face, the average error of was 0.99mm. And the maximum error was 6.64mm. In conclusion, We assessed that accuracy of 3D Automatic Face Recognition Apparatus(3D-AFRA) is considerably good.

  • PDF

A Selective Error Control Scheme based on Timely Retransmission in Multimedia Communications (멀티미디어통신에서 적시 재전송에 기반한 선택적인 오류 제어 방법)

  • Jeong, Chung-Il;Gwon, Do-Han;Park, Chang-Yun
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.26 no.10
    • /
    • pp.1225-1236
    • /
    • 1999
  • 기존의 오류 제어 방법들은 실시간 특성과 신축적인 신뢰성을 가지는 멀티미디어 통신 응용의 특징을 충분히 반영하지 못하고 있다. 본 연구는 기존의 재전송을 기반으로 하는 방법에 두 가지 기법을 추가하여 이 문제에 접근하였다. 첫째, 실시간 데이타의 마감 시간을 고려하여 미리 재전송을 실시하는 사전 재전송과 시간적으로 불가능하다고 판단될 때 복구를 포기하는 재전송 포기를 통한 적시 재전송 기법이다. 둘째, 요구되는 신뢰성에 근접하도록 오류가 많이 발생하였을 때만 재전송을 하는 선택적 오류 제어 기법이다. 본 연구는 두 기법을 적용한 오류 제어 프로토콜을 구현하고 네트워크 환경을 바꾸어 가며 성능을 검사하였다. 실험 결과, 제안된 오류 제어 방법은 전체적인 오류 제어 부하는 감소시키면서 오류 복구율을 높인다는 점을 확인하였다.Abstract The current error control schemes do not fit well to the characteristics of multimedia communications: real-time transmission and flexible reliability requirements. This research proposes a new error control scheme, which extends the retransmission-based error control with the following two mechanisms. First, error recovery is performed in two timely fashions: one is retransmission in advance where a retransmission is performed early enough for the deadline if an error is suspected, and the other is retransmission abort where a retransmission is given up if its recovery within the deadline seems to be impossible. Second, error control is selectively performed only when an actual error rate approaches to the threshold on a given reliability requirement. The proposed scheme has been implemented and experimented in various network environments. The performance results show that it has lower control overhead and higher error recovery than the existing schemes.

The Study for Apical Pulse Measurement Technique Through Hospitalized Children (입원한 영유아의 심첨 맥박 측정 방법에 관한 연구)

  • Cho Kyung Mi;Kim Eun Joo
    • Child Health Nursing Research
    • /
    • v.5 no.1
    • /
    • pp.48-58
    • /
    • 1999
  • The purpose of this study was to determine the most accurate technique measuring the apical pulse rate, using three counting duration 15, 30 and 60 seconds, and two methods start ‘0’ and start ‘1’. The instrument used in the study was the EKG monitor, stethoscope and stopwatch. Data was analyzed by utilizing SPSSWIN program. General characteristics of the subjects were analyzed by frequency, percentile, mean, SD. The subject of this research is made up of 46 children and 20 nurses. The children were infants, & under the age of 5. They were hospitalised in PICU & NICU in 2 tertiary hospitals in seoul from Jan. 1. 1998 to Sep. 10. 1998. The measurement of starting 1 & measurement of starting ‘0’ used the T-test to find out the measurement error. Apical pulse duration of 15, 30, 60 seconds were used to find out measurement error, the measurement error depend on experience of Nurse were analyzed by using ANOVA. The result of this study are as follows. 1. When comparing the starting poin of apical pulse 0&1, starting with 1 the measurement error is less, but not statiscally significant. 2. When counting the apical pulse by 15, 30,60 sec. ; 60 seconds counting duration was more accurate, but not statistically significant. 3. The mean of measure error ; Group under 100/min, is 10.33 ; from 100 re 119/min, is 8.30 ; from 120 to 139/min, is 4.76 ; from 140 to 159/min, is 6.09 ; above 160, is 17.83. The differences of these groups are statistically significant. When 60sec were counted, under 140/min the mean of measurement error is 3.4. Also when 30 seconds were counted from 140/min to 159/min the measurement error is 7.14, above 160/min the measurement error is 16.4. That measurement mean is the smallest than the other durations. During the 15 sec. count the measurement error was the largest of them all. 4. By the experience of the nurses, the apical pulse count measurement error was discovered. Under a year experience this measurement error was the largest(11.09), 1 year to under 3 years, the error is the smallest(4.86). 3 year to under 6 years the error is 8.33, 5 years above the error is 6.11 but this is not statistical significant. Under a year experience when counting 15, 30, 60 seconds the error is the largest. The group of the nurses from a year to under 3 years, the measurement error is the smallest of all the groups. The result of the study is to determine the technique measuring the apical pulse rate, Hargest (1974), starting point ‘0’ is not proved. When the pulse rate increases the 30 sec measurement rate is accurate. Under 140/min the 60 sec measurement rate is the most accurate. Depending on the nurses experiences, there is a variable difference to the apical pulse rate measurement. Especially new nurses training courses should enforce the children’s pulse rate count and the basic vital signs.

  • PDF

An Evaluation of Loss Factor of Damping Treatment Materials for Panels of Railway Vehicles (철도차량용 패널 감쇠처리재의 감쇠계수 평가)

  • Kang, Gil-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.489-496
    • /
    • 2019
  • This paper is a study on the evaluation of loss factor of damping treatment materials to reduce the noise and vibration for panels of railway vehicles and automobiles. In order to determine the modal parameters of damping materials, beam excitation tests were carried out using different type PVC coated aluminum and steel base beam specimens. The specimens were excited from 10 Hz to 1000 Hz frequency range using sinusoidal force, and transfer mobility data were measured by using an accelerometer. The loss factors were determined by using integrated program, based on theories of Half Power Method, Minimum Tangent Error Method, Minimum Angle Error Method and Phase Change Method, which enable to evaluate the parameters using modal circle fit and least squares error method. In the case of lower loss factor and data of linear characteristics, any method could be applied for evaluation of parameters, however the case of higher loss factor or data including non-linear characteristics, the minimum angle error method could reduce the loss factor evaluation. The obtained dynamic properties of the coating material could be used for application of Finite Element Method analyzing the noise control effects of complex structures such as carbody or under-floor boxes of rolling stock. The damping material will be very useful to control the structural noise, because the obtained modal loss factors of each mode show very good effect on over $2^{nd}$ mode frequency range.

Macro-model for Estimation of Maximum Power Dissipation of CMOS Digital Gates (CMOS 디지털 게이트의 최대소모전력 예측 매크로 모델)

  • Kim, Dong-Wook
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.10
    • /
    • pp.1317-1326
    • /
    • 1999
  • As the integration ratio and operation speed increase, it has become an important problem to estimate the dissipated power during the design procedure as a method to reduce the TTM(time to market). This paper proposed a prediction model to estimate the maximum dissipated power of a CMOS logic gate. This model uses a calculational method. It was formed by including the characteristics of MOSFETs of which a CMOS gate consists, the operational characteristics of the gate, and the characteristics of the input signals. As the modeling process, a maximum power estimation model for CMOS inverter was formed first, and then a conversion model to convert a multiple input CMOS gate into a corresponding CMOS inverter was proposed. Finally, the power model for inverter was applied to the converted result so that the model could be applied to a general CMOS gate. For experiment, several CMOS gates were designed in layout level by $0.6{\mu}m$ layout design rule. The result by comparing the calculated results with those from HSPICE simulations for the gates showed that the gate conversion model has within 5% of the relative error rate to the SPICE and the maximum power estimation model has within 10% of the relative error rate. Thus, the proposed models have sufficient accuracies. Also in calculation time, the proposed models was more than 30 times faster than SPICE simulation. Consequently, it can be said that the proposed model could be used efficiently to estimate the maximum dissipated power of a CMOS logic gate during the design procedure.

  • PDF

Variation of Psychophysiological Characteristics Related with Human Errors during a Simple Pointing Task (단순 지적과업 중 인간과오 관련 심리생리학적 특성의 변화)

  • Lim, Hyeon-Kyo
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.3
    • /
    • pp.71-78
    • /
    • 2009
  • During a learning process, a human being is assumed to experience knowledge-based behaviors, rule-based behaviors, and skill-based behaviors sequentially if Rasmussen was right. If any psycho-physiological symptom to those different levels can be obtained, it can be useful as a measure whether a human being is fully trained and has gotten a skill in his work. Therefore, this study aimed to draw relationships between human performance measures and psycho-physiological measures while committing a computer-simulated pointing task by utilizing the power spectrum technique of EEG data, especially with the ratio of relative beta-to-alpha band power. The result showed that, during correct responses, the ratio came to stabilize as all the performance data went stable. However, response time was not a simple linear function of task difficulty level only, but a joint function of task characteristics as well as behavior levels. Comparing relative band power ratios from errors and correct responses, activated states of one's brain could be explained, and characteristics of the task could understood. To tell that of pointing task, correlations around C3, C4, P3, P4 and 01, 02 area were significant and high in correct response cases whereas most correlation coefficients went down in error cases standing for imbalance of psycho-motor functions. Though task difficulty was the only one factor that could influence on relative band power ratio with statistical significance, it should be comprehended to mean a different way of expression indicating task characteristics since at least error-some situation could be explained with the help of relative band power ratio that absolute band power failed.