• Title/Summary/Keyword: erection

Search Result 338, Processing Time 0.025 seconds

Experimental study on standard and innovative bolted end-plate beam-to-beam joints under bending

  • Katula, Levente;Dunai, Laszlo
    • Steel and Composite Structures
    • /
    • v.18 no.6
    • /
    • pp.1423-1450
    • /
    • 2015
  • The paper presents the details and results of an experimental study on bolted end-plate joints of industrial type steel building frames. The investigated joints are commonly used in Lindab-Astron industrial buildings and are optimized for manufacturing, erection and durability. The aim of the research was to provide an experimental background for the design model development by studying load-bearing capacity of joints, bolt force distribution, and end-plate deformations. Because of the special joint details, (i.e., joints with four bolts in one bolt-row and HammerHead arrangements), the Eurocode 3 standardized component model had to be improved and extended. The experimental programme included six different end-plate and bolt arrangements and covered sixteen specimens. The steel grade of test specimens was S355, the bolt diameter M20, whereas the bolt grade was 8.8 and 10.9 for the two series. The end-plate thickness varied between 12 mm and 24 mm. The specimens were investigated under pure bending conditions using a four-point-bending test arrangement. In all tests the typical displacements and the bolt force distribution were measured. The end-plate plastic deformations were measured after the tests by an automatic measuring device. The measured data were presented and evaluated by the moment-bolt-row force and moment-distance from centre of compression diagrams and by the deformed end-plate surfaces. From the results the typical failure modes and the joint behaviour were specified and presented. Furthermore the influence of the end-plate thickness and the pretension of the bolts on the behaviour of bolted joints were analysed.

The design of 111m high steel towers with 220kv double circuits crossing 12 km wide Bangladesh River (230KV 2회선승 111M 높이 철탑설계 (I) (강폭 12km인 Bangladesh Jamana강 횡단용))

  • 이재숙
    • Journal of the Korean Professional Engineers Association
    • /
    • v.15 no.4
    • /
    • pp.12-24
    • /
    • 1982
  • East Parts of Bangladesh have been benifited by low cost energy generated by domestic natural gas but West parts where energy generated by imported fuel. Bangladesh Government authority has very much concerned to transmit the low cost electricity to the West from the East for past several years. To solve such concerns, cross-country 230kv double circuits Power transmission line was proposed, however there was a big obstacle for the realization of this line to cross the Jamuna river which has 12 km long width with a deep muddy river bed. A consultant engineering firm named Merz-Mclellan anyway finalized this plan and a world-wide bid was announced on June 31, 1979. Due to the expected difficulty to construct the towers on sea like area, only three construction groups have participated. including a Korean joint venture organization of Samsung-Korean Developement corporation-Kolon Electric Machinery company. After 3 months bid evaluation, contract was awarded to Korean Consosium and KEM Co was in charge of designing steel towers with anchor bolts and base plates beside to electrical engineering field. Then KEM Co have faced and over-comed many unenpected technical difficulties such as forced eccentricity joint on base plate, distorsion issue of 60mm thick plates welding, threading anchor bolts, tad heat treatment of some anchor bolts, disagreement from Consultant Engineer on multiplying factor of leg stresses for 45$^{\circ}$ wind and on reducing O.L.F for wind loads on cables for such 1220km long spans. After spending two years long period for designing and engineering towers, base plates, and anchor bolts, first shipment of tower was finally realized on Nov. 8, 1981 and on the other hand KDD has proceeded concrete caisson work on schedule at Jamuna river site and expected to complete tower erection and stringing of cables within this year of 1982 which was original completion target.

  • PDF

Feasibility Analysis for Introduction of Scaffolding with Advanced Guardrail System to Prevent Falls (비계작업의 추락재해예방을 위한 선행 안전난간 공법의 도입 타당성 분석)

  • Park, J.D.;Moon, S.O.;Lee, H.S.;Jeong, S.C.;Kwon, Y.J.;Jung, K.
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.4
    • /
    • pp.23-31
    • /
    • 2020
  • In the construction sector, there were 99 fatalities from falls associated with steel tube and system scaffolds for three years from 2016 to 2018 and out of which 27.3 percent (27 workers) were found to have occurred during installing and dismantling procedure. To erect scaffolding which is installed for the work at height, the work platforms are generally installed first and the safety guardrails are installed and vice versa to dismantle. As a result, workers are exposed to the risk of falling because they erect and dismantle scaffolding without guardrails. To minimize the risk of falling, it is necessary to study a new construction method that can erect or dismantle scaffolding while guardrails are installed (called advanced guardrail system). This study analyzed advanced guardrail system in terms of safety regulation, workability and economic efficiency by investigating the domestic situation on the use of scaffolding, reviewing domestic and foreign standards for guardrails and conducting economic feasibility study. The results of this study is expected to greatly contribute to preventing falls in scaffolding installation and dismantlement procedure. As a follow-up study, empirical research is required including physical test of scaffolding with advanced guardrail system and effectiveness analysis after trial applications.

Design and Construction of GINZA KABUKIZA

  • Kawamura, Hiroshi;Ishibashi, Yoji;Morofushi, Tsutomu;Saragai, Yasuyuki;Inubushi, Akira;Yasutomi, Ayako;Fuse, Naohiko;Yoshifuku, Manabu;Saitoh, Kouji
    • International Journal of High-Rise Buildings
    • /
    • v.5 no.3
    • /
    • pp.233-241
    • /
    • 2016
  • This paper describes the structural solution for the design of a 29-story high-rise tower, which features a large office space above the Kabukiza Theatre. Kabuki is a type of Japanese traditional drama, and Kabukiza is the home building of Kabuki. GINZA KABUKIZA is the fifth generation of the Kabukiza Theatre, the first of which was built in 1889. In order to support 23 stories of office space above the theater - featuring a large void in plan - two 13-meter-deep mega-trusses, spanning 38.4 meters, are installed at the fifth floor of the building. Steelwork is used as a primary material for the structure above-ground, and a hybrid response control system using a buckling-restrained brace and oil damper is adopted in order to achieve a high seismic performance. This paper also describes the erection process of installing hydraulic jacks directly above the mega-truss at column bases, in order to keep the structure above the truss level during construction. The temple architecture of the previous Kabukiza is carefully restored by incorporating contemporary light-weight materials supported by steelwork.

Evaluation of Structural Performance the Hollow PC Column Joint Subjected to Cyclic Lateral Load (반복 횡하중을 받는 유공 PC 기둥 접합부의 구조성능 평가)

  • Seo, Soo-Yeon;Yoon, Seong-Joe;Lee, Woo-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.3
    • /
    • pp.335-343
    • /
    • 2008
  • In order to improve the workability in erecting Precast Concrete (PC) members and enhance the seismic resistance capacity of the joints in PC moment frames, a new PC column and its construction process are introduced in this paper. This column is manufactured by centrifugal force in keeping the hollow tube inside; the hollow is little bit wide and the grout can be poured from top to bottom after erection at site so that more compact grouting is possible in horizontal joint. The repeated cyclic loading test for four full scaled specimens was conducted to evaluate the seismic resistance capacity of the joint designed by the proposed system. For the continuity of main reinforcements in column, two connecting methods are used in designing specimens; one is to use mechanical connector and other is lab splice. From the cyclic lateral loading test, it was found that the seismic capacity of the developed PC column joint is comparable to that of monolithic joint.

A Study on the Unstable behavior According to rise-span ratio of dome type space frame (돔형 공간 구조물의 Rise-span 비에 따른 불안정 거동 특성에 관한 연구)

  • Shon, Su-Deok;Kim, Seung-Deog;Kang, Moon-Myung
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 2004.05a
    • /
    • pp.75-82
    • /
    • 2004
  • Many researcher's efforts have made a significant advancement of space frame structure with various portion, and it becomes the most outsanding one of space structures. However, with the characteristics of thin and long term of spacing, the unstable behavior of space structure is shown by initial imperfection, erection procedure or joint, especially space frame structure represents more. This kind of unstable problem could not be set up clearly and there is a huge difference between theory and experiment. Moreover, the discrete structure such as space frame has more complex solution, this it is not easy to derive the formulation of design about space structure. In this space frame structure, the character of rise-span ratio or load mode is represented by the instability of space frame structure with initial imperfection, and snap-through or bifurcation might be the main phenomenon. Therefore, in this study, space frame structure which has a lot of aesthetic effect and profitable for large space covering single layer is dealt. And because that the unstable behavior due to variation of inner force resistance in the elastic range is very important collapse mechanism, I would like to investigate unstable character as a nonlinear behavior with a geometric nonlinear. In order to study the instability. I derive tangent stiffness matrix using finite element method and with displacement incremental method perform nonlinear analysis of unit space structure, star dome and 3-ring star dome considering rise-span $ratio(\mu}$ and load $ratio(R_L)$ for analyzing unstable phenomenon.

  • PDF

Seismic characterization of cold formed steel pallet racks

  • Saravanan, M.;Marimuthu, V.;Prabha, P.;Surendran, M.;Palani, G.S.
    • Earthquakes and Structures
    • /
    • v.7 no.6
    • /
    • pp.955-967
    • /
    • 2014
  • Storage racks are used worldwide in industries and commercial outlets due to the advantage of lighter, faster erection and easy alteration of pallet level as required. The studies to understand the behaviour of cold formed steel pallet racks, under seismic action is one of the emerging area of research. The rack consists of perforated uprights and beams with hook-in end connector, which enables the floor height adjustments. The dynamic characteristics of these racks are not well established. This paper presents the dynamic characteristics of 3-D single bay two storey pallet rack system with hook-in end connectors, which is tested on shake table. The sweep sine test and El Centro earthquake acceleration is used to evaluate the seismic performance of the cold formed steel pallet racks. Also an attempt is made to evaluate the realistic dynamic characteristics by using STAAD Pro software. Modal analysis is performed by incorporating the effective moment of inertia of the upright, which considers the effect of presence of perforations and rotational stiffness of the beam-to-upright connection to determine the realistic fundamental frequency of pallet racks, which is required for carrying out the seismic design. Finite element model of the perforated upright section has been developed as a cantilever beam through which effective moment of inertia is evaluated. The stiffness of the hook-in connector is taken from the previous study by Prabha et al. (2010). The results from modal analysis are in good agreement with the respective experimental results.

The Development and Application of Intelligent Welding Carriage with High Deposition Rate by 3-D Weaving (3차원 위빙 대용착 지능 용접캐리지 개발 및 적용)

  • Kim, Young-Zoo;Cho, Bang-Hyun;Amit, Amit;Lee, Sang-Bum;Lee, Weon-Gu;Kim, Jin-Yong;Huh, Man-Joo
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.65-65
    • /
    • 2010
  • In shipbuilding industry, welding position are usually flat and vertical position at the erection stage. Application of SAW and EGW for these positions makes it possible to achieve enhanced productivity and high quality. But owing to their large size and weight it is difficult to apply these techniques in short and narrow regions. To overcome this problem, our company developed light weight and compact size 4-axis welding carriage which perform 3D weaving. The purpose of this study is to explain the development and application of intelligent welding carriage using 3D weaving pattern that can fill a large amount of welds and thereby making it possible to achieve high quality of welding. This study shows 3D weaving pattern, development of weaving database, and skill of adaptive control response for the variable gap. Also, it shows the results of procedure qualification test for the AH-grade steel when applied to the intelligent welding carriage.

  • PDF

A study on the architectural character of JE-DANG in Ulsan (울산지역(蔚山地域) 제당(祭堂)의 건축적(建築的) 특성(特性)에 관한 연구(硏究) - 웅재면(熊材面)과 강동면(江東面)의 제당(祭堂)을 사례(事例)로 -)

  • Kang, Hye-Kyung;Nishimura, Ichiro;Han, Sam-Geon
    • Journal of architectural history
    • /
    • v.8 no.3 s.20
    • /
    • pp.9-22
    • /
    • 1999
  • The purpose of this study is to analyse the architectural character of JE-DAMG at farm village in Ulsan. JE-DANG means the building for DONG-JE (the sacrificial rite of a village). The regions of this study are KANG-DONG MYEN, and UNG-CHON MYEN in Ulsan. The method of this study is the analysis of them after the actual field surveys of 47 JE-DANGs in these regions The survey contains the area, the height, the period of the erection, the architectural structure, the roof shape, the material, the landowner, SHIN-CHE (means a god's name and shape), DANG-SU tree and so on. Methods of the survey are the field survey, the interview of villager, the analysis of reference data and so on. Results of the study are below. JE-DANGs(buildings) of these regions had been built first in the period of Japanese occupancy and erections of them had continued until 1970's. Since then, they have been rebuilt. The primary JE-DANG is characterized by a tiled roof, a wooden post lintel, a mud-plastered wall, and a wooden door. After rebuilding, characters are a flat slab, a tiled roof, a structure of using red bricks, and the area is getting larger than the primary JE-DANG, but 1 KAN persists without variety. Most of houses in the inland area like UNG-CHON MYEN face the south, and ones in the coastal area like KANG-BONG MYEN face the east. Generally there is DANG-SU tree behind JE-DANG. That proves DANG-SU tree to be the object of the rite. The species of DANG-SU is a pine in general ,but various in UNG-CHON MYEN. In general names of the god are DONG-SHIN , DANG-SAN SHIN and SUNG-HWANG SHIN. I think that the landownership of JE-DANG should change the private ownership into the village ownership to preserve JE-DANG though most of lands of JE-DANG are private ones.

  • PDF

Studies on Constituents of the Higher Fungi of Korea(LIV) -Studies on Toxic Component of Auricularia polytricha- (한국산(韓國産) 고등균류(高等菌類)의 성분연구(成分硏究)(제54보)(第54報) -털목이의 독성(毒性) 성분(成分)에 관한 연구(硏究)-)

  • Kim, Ha-Won;Choi, Eung-Chil;Kim, Byong-Kak
    • The Korean Journal of Mycology
    • /
    • v.14 no.4
    • /
    • pp.265-271
    • /
    • 1986
  • To screen biologically active components of the higher fungi of Korea, the dried carpophores of Auricularia polytricha were extracted with water. The extract was examined for acute toxicity in ICR mice. A low molecular weight toxin of this fungus was purified by a acetone precipitation followed by cellulose, silica gel and Sephadex LH-20 column chromatography. Major symptoms of this toxin were decreasing of normal motility, eye extrusion, hair erection, shivering, trembling of head, paralysis, rapid running or moving before death and depression of respiration. The median lethal doses of the total extract were 1. 28 g/kg and 4. 31 g/kg by i.p. and p.o. administrations, respectively. The amounts of one mouse lethal unit of the total extract and final fraction that killed a 20 g mouse within 30 minutes were 28.5 and 12.0 mg/mouse, respectively.

  • PDF