• 제목/요약/키워드: equivalent series resistance

검색결과 92건 처리시간 0.025초

Zigbee 무선통신을 이용한 UPS DC링크 커패시터의 고장 모니터링 시스템 개발 (A development of Diagnosis Monitoring System for UPS DC Link Capacitors using Zigbee Wireless Communication)

  • 김동준;손진근;전희종
    • 전기학회논문지P
    • /
    • 제61권1호
    • /
    • pp.41-46
    • /
    • 2012
  • Electrolytic power capacitors have been widely used in power conversion system such as inverter or UPS because of characteristics of large capacitance, high-voltage and low-cost. The electrolytic capacitor, which is most of the time affected by the aging effect, plays a very important role for the power-electronics system quality and reliability. Therefore it is important to diagnosis monitoring the condition of an electrolytic capacitor in real-time to predict the failure. In this paper, the on-line remote diagnosis monitoring system for UPS DC link electrolytic capacitors using low-cost single-chip zigbee communication modules is developed. To estimate the health status of the capacitor, the equivalent series resistor(ESR) of the component has to be determined. The capacitor ESR is estimated by using RMS computation using BPF modeling of DC link ripple voltage/current. Zigbee-based hardware experimental results show that the proposed remote capacitor diagnosis monitoring system can be applied to UPS successfully.

가전용 커패시터의 소손원인 규명 및 발열 메커니즘 해석 (Examination of the Cause of Damage to Capacitors for Home Appliances and Analysis of the Heat Generation Mechanism)

  • 박형기;최충석
    • 한국안전학회지
    • /
    • 제26권6호
    • /
    • pp.13-19
    • /
    • 2011
  • The purpose of this study is to examine the cause of damage to electrolytic capacitors and to present the heat generation mechanism in order to prevent the occurrence of similar problems. From the analysis results of electrolytic capacitors collected from accident sites, the fire causing area can be limited to the primary power supply for the initial accident. From the tests performed by applying overvoltage, surge, etc., it is thought that the fuse, varistor, etc., are not directly related to the accidents that occurred. The analysis of the characteristics using a switching regulator showed that the charge and discharge characteristics fell short of standard values. In addition, it is thought that heated electrolytic capacitors caused thermal stress to nearby resistances, elements, etc. It can be seen that the heat generation is governed by the over-ripple current, application of AC overvoltage, surge input, internal temperature increase, defective airtightness, etc. Therefore, when designing an electrolytic capacitor, it is necessary to comprehensively consider the correct polarity arrangement, appropriate voltage application, correct connection of equivalent series resistance(ESR) and equivalent series inductance(SEL), rapid charge and discharge control, sufficient margin of dielectric tangent, etc.

Zigbee통신을 이용한 전력변환기기의 DC Bus 커패시터의 온라인 원격 고장진단 시스템 (On-line Remote Diagnosis System for DC Bus Capacitor of Power Converters Using Zigbee Communication)

  • 정완섭;손진근
    • 전기학회논문지P
    • /
    • 제64권1호
    • /
    • pp.29-34
    • /
    • 2015
  • DC bus electrolytic capacitors are used in variety of equipments as smoothing element of the power converters because it has high capacitance for its size and low price. It is responsible for frequent breakdowns of many static converters and inverter drive systems. Therefore it is important to diagnosis monitoring the condition of an electrolytic capacitor in real-time to predict the failure of power converter. In this paper, the on-line remote diagnosis monitoring system for DC BUS electrolytic capacitors of power converter using low-cost type Zigbee communication modules is developed. To estimate the health status of the capacitor, the equivalent series resistor(ESR) of the component has to be determined. The capacitor ESR is estimated by using RMS computation using AC coupling method of DC link ripple voltage/current. The Zigbee communication-based experimental results show that the proposed remote DC capacitor diagnosis monitoring system can be applied to DC/DC converter and UPS successfully.

저항성 십자 표면 구조를 이용한 광대역 박형 흡수체 설계 (Design of Wideband Thin Absorber Using Resistive Cross-Shaped Surface Structures)

  • 이준호;김건영;이범선
    • 한국전자파학회논문지
    • /
    • 제26권3호
    • /
    • pp.311-316
    • /
    • 2015
  • 본 논문에서는 저항성 sheet를 이용한 광대역 박형 흡수체 설계법을 제안한다. 제안된 흡수체의 등가회로는 직렬 RLC 공진회로와 종단이 단락된 전송선으로 이루어진다. 이 등가회로를 바탕으로 임의의 설계주파수에서 흡수체가 ${\lambda}/4$보다 얇은 두께를 가지면서도, 광대역 흡수율 특성을 가지는 세가지 조건을 정리하였다. 수치해석을 통해 이를 동시에 만족하는 R, L, C 소자 값을 구했다. 구한 등가 R, L, C값은 특정한 chip 저항이나 표면저항을 가지는 십자 모양의 구조로써 구현이 가능하다. 이러한 설계법을 설계 중심주파수 3 GHz에서 적용해서 두께가 18.75 mm(전기적 길이 $67.5^{\circ}$)이고, 90 % 흡수율 기준으로 116 % 대역폭을 갖는 광대역 흡수체를 설계하였다.

주파수 의존적인 회로상수를 이용한 시변자장 시스템의 과도상태 해석 (Transient Analysis of Magnetodynamic Systems Using Frequency-dependent Circuit Parameters)

  • 최명준;이세희;박일한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.61-63
    • /
    • 1999
  • This paper presents an efficient method for analysis of magnetodynamic system using frequency-dependent parameters. In equivalent electric circuit of linear magnetodynamic system, parameters of inductance and resistance are not constant since they vary with its driving frequency. Once frequency-dependent parameters of equivalent electric circuit for a given system are extracted, they can be used to analyze various characteristics of system. We use the Fourier transform, the high-order sensitivity method and Taylor series in order to efficiently extract the frequency-dependent parameters of magnetodynamic system. The proposed algorithm is applied to an induction heating system to validate its numerical efficiency.

  • PDF

탄소 전극 형상 변화에 따른 전기화학 커패시터 특성 향상 (Improvement of Electrochemical Characteristics by Changing Morphologies of Carbon Electrode)

  • 민형섭;김상식;정덕수;최원국;오영제;이전국
    • 한국재료학회지
    • /
    • 제19권10호
    • /
    • pp.544-549
    • /
    • 2009
  • Activated carbon (AC) with very large surface area has high capacitance per weight. However, such activation methods tend to suffer from low yields, below 50%, and are low in electrode density and capacitance per volume. Carbon NanoFibers (CNFs) had high surface area polarizability, high electrical conductivity and chemical stability, as well as extremely high mechanical strength and modulus, which make them an important material for electrochemical capacitors. The electrochemical properties of immobilized CNF electrodes were studied for use as in electrical double layer capacitor (EDLC) applications. Immobilized CNFs on Ni foam grown by thermal chemical vapor deposition (CVD) were successfully fabricated. CNFs had a uniform diameter range from 50 to 60 nm. Surface area was 56 m$^2$/g. CNF electrodes were compared with AC and multi wall carbon nanotube (MWNT) electrodes. The electrochemical performance of the various electrodes was examined with aqueous electrolyte of 2M KOH. Equivalent series resistance (ESR) of the CNF electrodes was lower than that of AC and MWNT electrodes. The specific capacitance of 47.5 F/g of the CNF electrodes was achieved with discharge current density of 1 mA/cm$^2$.

트랜지스터 광대역궤환증폭기 (Transistor Wide-Band Feedback Amplifiers)

  • 이병선;이상배
    • 대한전자공학회논문지
    • /
    • 제5권1호
    • /
    • pp.13-25
    • /
    • 1968
  • 고주파용 transistor를 이용한 광대역증폭기를 hybrid-π 등가회로를 이용하여 상세하게 분석하였다. 저주파와 고주파의 경우에 관한 해석을 하였고 이득과 대역폭및 입력 impedance와 출력 impedance를 주는 식을 유도하였다. 직렬궤환증폭기는 전압원으로 구동하여야하며 저저항부하로 동작시켜야 하고 병렬궤환증폭기는 전류원으로 구동하여야 하며 고저항부하로 동작시켜야 하는 것을 표시하였고 이 두가지 증폭단은 완충증폭단이나 변압기결합을 하지않고 결합시킬 수 있음을 표시하였다.

  • PDF

Supercapacitor용 활성탄 전극의 전기 화학적 특성 (Electrochemical Characteristics of Activated Carbon Electrode for Supercapacitor)

  • 김경민;이용욱;강안수
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2002년도 추계학술대회
    • /
    • pp.273-277
    • /
    • 2002
  • In the electrode fabrication of unit cell, we found that optimal the electrochemical characteristics were obtained with at 90 wt.% of activated carbon(BP-20), 5 wt.% of conducting agent(Ppy, Super P) and 5 wt.% of P(VdF-co-HFP)/PVP mixed binder. The electrochemical characteristics of unit cell with Ppy improver were as follows : 37.6 F/g of specific capacitance, 0.98 $\Omega$ of AC-ESR, 2.92 Wh/kg and 6.05 Wh/L of energy density, and 754 W/kg and 1,562 W/L of power density. It was confirmed that internal resistance were reduced due to the increase of electrical conductivity and filling density by the introduction of conductivity agent, and content of conducting agent was suitable in the range of 4~6 wt.%. According to the impedance measurement of the electrode with conductivity agent, we found that it was possible to charge rapidly by the fast steady-state current convergence due to low equivalent series resistance(AC-ESR), fast charge transfer rate at interface between electrode and electrolyte, and low RC time constant.

  • PDF

텅스텐 전극에 입힌 폴리아닐린의 전기화학적 임피던스 (Electrochemical Impedance Analysis of Polyaniline-Film on Tungsten Electrodes)

  • 천정균;민병훈
    • 대한화학회지
    • /
    • 제40권1호
    • /
    • pp.37-43
    • /
    • 1996
  • 텅스텐을 작업 전극으로 사용하여 순환 전압-전류법으로 합성한 폴리아닐린 막의 전기화학적 임피던스를 0.1M 황산 용액에서 측정하였다. 전기 전도성을 갖는 퍼텐셜 영역에서는 고분자 막의 큰 축전-용량과작은 저항이 직렬로 연결된 전기화학 쎌이 관측되었다. 순수한 텅스텐에 입혀진 폴리아닐린은 접촉 저항을 무시할 수 있었으나, 산화 전극 막이 입혀진 텅스텐의 경우는 산화 전극 막의 저항과 접촉 저항이 관측되었다. 측정된 임피던스 데이터로부터 전극의 등가 회로를 추정하였으며, 이 등가 회로를 토대로 하여 폴리아닐린-막 안에 혼입된 이온의 물질 이동 파라미터를 산출하였다.

  • PDF

A simple approach for quality evaluation of non-slender, cast-in-place piles

  • Zhang, Ray Ruichong
    • Smart Structures and Systems
    • /
    • 제4권1호
    • /
    • pp.1-17
    • /
    • 2008
  • This study proposes a conceptual framework of in-situ vibration tests and analyses for quality appraisal of non-slender, cast-in-place piles with irregular cross-section configuration. It evaluates a frequency index from vibration recordings to a series of impulse loadings that is related to total soil-resistance forces around a pile, so as to assess if the pile achieves the design requirement in terms of bearing capacity. In particular, in-situ pile-vibration tests in sequential are carried out, in which dropping a weight from different heights generates series impulse loadings with low-to-high amplitudes. The high-amplitude impulse is designed in way that the load will generate equivalent static load that is equal to or larger than the designed bearing capacity of the pile. This study then uses empirical mode decomposition and Hilbert spectral analysis for processing the nonstationary, short-period recordings, so as to single out with accuracy the frequency index. Comparison of the frequency indices identified from the recordings to the series loadings with the design-based one would tell if the total soil resistance force remains linear or nonlinear and subsequently for the quality appraisal of the pile. As an example, this study investigates six data sets collected from the in-situ tests of two piles in Taipu water pump project, Jiangshu Province of China. It concludes that the two piles have the actual axial load capacity higher than the designed bearing capacity. The true bearing capacity of the piles under investigation can be estimated with accuracy if the amplitude of impact loadings is further increased and the analyses are calibrated with the static testing results.