• Title/Summary/Keyword: equivalent power

Search Result 1,752, Processing Time 0.03 seconds

A Study on the Fuel Cell Equivalent Circuit Modeling (연료전지 수치해석을 이용한 등가회로 모델링 연구)

  • OH, HWANYEONG;CHOI, YOON YOUNG;SOHN, YOUNG-JUN
    • Journal of Hydrogen and New Energy
    • /
    • v.33 no.3
    • /
    • pp.226-231
    • /
    • 2022
  • Power converter are usually equipped for fuel cell power generation system to connect alternating current (AC) electric power grid. When converting direct current (DC) of fuel cell power source into AC, the power converter has a frequency ripple, which affects the fuel cell and the grid. Therefore, an equivalent circuit having dynamic characteristics of fuel cell power, for example, impedance, is useful for designing an inverter circuit. In this study, the current, voltage and impedance characteristics were calculated through fuel cell modeling and validated by comparing them with experiments. The equivalent circuit element values according to the current density were formulated into equations so that it could be applied to the circuit design. It is expected that the process of the equivalent circuit modeling will be applied to the actual inverter circuit design and simulated fuel cell power sources.

EMTP simulation of 345kv Substation in large network using newly developed Thevenin equivalent network (345kv 미금 변전소 외부 계통의 등가축약 기법을 이용한 EMTP 모델링에 관한 연구)

  • Jeong, Ki-Seok;Baek, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.244-246
    • /
    • 2008
  • EMTP-RV is the very powerful program to analyze the dynamic operation of the power system. To use this package in the large complex power system, it is very important to simplify the power system to simple equivalent network. In our study the 100 MVA STATCOM is placed at 345kV "MIGUM" which is the one of the 345kV substations of the Korean Electric Power System that is consist of more than 1000 bus. MIGUM substation is connected with 7 separated transmission lines to main Korean Electric power system. We developed a new method to simplify the network except the substation that we want to analysis. The power system outside the 345kV substation is modeled into the equivalent network. The loop network outside the substation can be modeled to simplified Thevenin equivalent network. The proposed method is applied to IEEE-14 Reliability Test System and the results shows the effectiveness of the method.

  • PDF

A Study on DC side Model of Current Source type Active Power Filters (전류원형 능동 전력 필터의 직류측 모델에 관한 연구)

  • Han, Hak-Guhn;Park, In-Gyu;Park, Jong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.180-185
    • /
    • 1989
  • In the current source type active power filter, the DC current source is implemented using an inductor with large inductance by maintaining the inductor current constantly. In this case, to compensate the loss of the switching devices of the power converter and the inductor, some real power should be supplied to the filter from the source. This process is analyzed through the equivalent circuit which expresses the loss of the switching devices and the inductor with the equivalent resistor R. This work discusses the validation of this DC side equivalent circuit and points out the problems, through the experiments using the experimental active power filter with 220V, 10KVA ratings, and suggests a more accurate equivalent circuit which puts the saturation voltage of the power transistors and the threshold voltage of the diodes into consideration.

  • PDF

A Study on the Equivalent Model of an External Electrode Fluorescent Lamp Based on Equivalent Resistance and Capacitance Variation

  • Cho, Kyu-Min;Oh, Won-Sik;Moon, Gun-Woo;Park, Mun-Soo;Lee, Sang-Gil
    • Journal of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.38-43
    • /
    • 2007
  • An External Electrode Fluorescent Lamp (EEFL) has longer lifespan, higher power efficiency and higher luminance than a Cold Cathode Fluorescent Lamp (CCFL). Moreover, it is easy to drive them in parallel. Therefore, the EEFL is expected to quickly replace the CCFL in LCD backlight systems. However, the EEFL has more complex characteristics than the CCFL with a resistive component, because it has both a resistive component by plasma and a capacitive component by external electrode. In this paper, values of resistance and capacitance are measured at several power levels and at several operating frequencies. They are expressed by a numeral formula based on a linear approximation that represents the equivalent resistance and capacitance as a function of power. Then we made block diagram of the equivalent circuit model using numerical expressions. Simulation waveforms and experimental results are presented to verify the feasibility of the equivalent model.

An Experimental Study on Multiple ICP & Helicon Source for Oxidation in Semiconductor Process

  • Lee, Jin-Won;Na, Byoung-Keun;An, Sang-Hyuk;Chang, Hong-Young
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.271-271
    • /
    • 2012
  • Many studies have been investigated on high density plasma source (Electron Cyclotron Resonance, Inductively Coupled Plasma, Helicon plasma) for large area source after It is announced that productivity of plasma process depends on plasma density. In this presentation, we will propose the new concept of the multiple source, which consists of a parallel connection of ICP sources and helicon plasma sources. For plasma uniformity, equivalent power (especially, equivalent current in ICP & Helicon) should distribute on each source. We design power feeding line as coaxial transmission line with same length of ground line in each source for equivalent power distribution. And we confirm the equivalent power distribution with simulation and experimental result. Based on basic study, we develop the plasma source for oxidation in semiconductor process. we will discuss the relationship between the processing parameters (With or WithOut magnet, operating pressure, input power ). In ICP, plasma density uniformity is uniform. In ICP with magnet (or Helicon) plasma density is not uniform. As a result, new design (magnet arrangement and gas distributor and etc..) are needed for uniform plasma density in ICP with magnet and Helicon.

  • PDF

EMTP Simulation of 345kV Substation in Large Network Using Newly Developed Thevenin Equivalent Network (345kv 미금 변전소 외부 계통의 등가축약 기법을 이용한 EMTP 모델링에 관한 연구)

  • Kwon, Ki-Jin;Jeong, Ki-Seok;Seo, Gyu-Seok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.14 no.3
    • /
    • pp.121-125
    • /
    • 2011
  • EMTP-RV is the very powerful program to analyze the dynamic operation of the power system. To use this package in the large complex power system, it is very important to simplify the power system to simple equivalent network. In our study the 100 MVA STATCOM is placed at 345kV "MIGUM" which is the one of the 345kV substations of the Korean Electric Power System that is consist of more than 1000-bus. MIGUM substation is connected with 7 separated transmission lines to main Korean Electric power system. We developed a new method to simplify the network except the substation that we want to analysis. The power system outside the 345kV substation is modeled into the equivalent network. The loop network outside the substation can be modeled to simplified Thevenin equivalent network. The proposed method is applied to IEEE-14 Reliability Test System and the results shows the effectiveness of the method.

Equivalent Plate Model and Acoustic Power Radiation of the Corrugated Panel Structures for High Speed Train (고속전철용 주름판넬구조의 등가평판모델 및 방사소음)

  • 장준호;이상윤;홍성철;이우식
    • Journal of the Korean Society for Railway
    • /
    • v.2 no.3
    • /
    • pp.26-35
    • /
    • 1999
  • The acoustic power reduction method can be used to design a quiet structure. To calculate the acoustic power radiated from a vibrating structure, the dynamic responses have to be determined. It is not easy to analyse the structure composed of the corrugated panels because of the structural complexity and the long analysing time. To make up for these defects, the equivalent orthotropic panel is presented. Also the acoustic power prediction method of the vibrating structures is proposed. As examples, the equivalent material properties of the corrugated plates are obtained and the acoustic powers of the floor structure are calculated at several frequency regions for the Korean High Speed Train.

  • PDF

A Study on the Dynamic Analysis Modeling of Industrial Robot's Wrist Power Transmission (산업용 로봇 손목 동력 전달계의 동특성 해석 모델 연구)

  • 김우형;정두한;최영삼;정진태;임흥순
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.243-246
    • /
    • 2004
  • The dynamic characteristic of a wrist power transmission examine closely with mass property, to present the model which induce the vibration is ultimately the purpose. A robot wrist power transmission for analysis model got the mass property through the approach to be the experimental. A bearing equivalent stiffness which supports the axis and a gear contact equivalent stiffness are determined by the simplicity analysis model compared the result of the experiment. We calculate the vibration tendency of the robot wrist power transmission by an analysis tool which is called the RecurDyn. We compared it with a signal analysis experiment's which a robot operation happens which is based on the ambient noise.

  • PDF

A Review Method of Calculation Results on Cable Ampacity using the Transformation to Electric Equivalent Circuit from Cable Thermal Circuit (케이블 열회로의 전기적 등가회로 변환을 이용한 케이블 허용전류 검토 방법)

  • Kang, Yeon-Woog;Kim, Min-Ju;Jang, Tae-In;Park, Jin-Woo;Park, Hung-Sok;Kang, JI-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.738-744
    • /
    • 2016
  • Current rating of a power cable can be calculated by the maximum allowable temperature in an insulating material considering the heat transfer from cable conductor. Therefore, it is very important to calculate the current rating using electrical equivalent circuit by calculated cable thermal circuit parameters but, it has not been fully investigated yet. In this paper, in order to determine the current rating of power cable, conventional calculation method has been reviewed considering the conductor resistance, loss factor of sheath, dielectric losses and thermal resistances based on the maximum allowable temperature of 345 kV $2500mm^2$ XLPE cable. To confirm the calculation result of the current rating, the conductor temperature should be examined whether it reaches the maximum allowable temperature by the thermal equivalent circuit of the cable. Then, utilizing EMTP (Electro-Magnetic Transient Program) which is a conventional program for electrical circuit, the thermal equivalent circuit was transformed to an electric equivalent circuit using an analogous relationship between thermal circuit and electrical circuit, and temperature condition including cable conductor, sheath, cable jacket could be calculated by the current rating of 345 kV $2500mm^2$ XLPE cable.

Chaos Synchronization using Chua Circuit with Equivalent Power Line (등가 전력선을 가진 Chua 회로에서의 카오스 동기화)

  • 배영철
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.259-262
    • /
    • 2000
  • Chua's circuit is a simple electronic network which exhibits a variety of bihucation and attractors. The circuit consists of two capacitors, an inductor, a linear resistor, and a nonlinear resistor. In this paper, a transmitter and a receiver using two identical Chua's circuits are proposed anti synchronizations of a equivalent power line are investigated. Since the synchronization of the equivalent power line system is impossible by coupled synchronization, theory having both the drive-response and the coupled synchronization is proposed. Af a result, the chaos synchronization has delay characteristics in the equivalent power line transmission system caused by the line parameters L and C.

  • PDF