• Title/Summary/Keyword: equivalent impedance

Search Result 491, Processing Time 0.032 seconds

Tri-band Microstrip Bandpass Filter Using Dual-Mode Stepped-Impedance Resonator

  • Liu, Haiwen;Lei, Jiuhuai;Zhao, Yulong;Xu, Wenyuan;Fan, Yichao;Wu, Tiantian
    • ETRI Journal
    • /
    • v.35 no.2
    • /
    • pp.344-347
    • /
    • 2013
  • This letter presents a compact dual-mode tri-band bandpass filter by using a short-circuited stub-loaded stepped-impedance resonator (SIR) and a short-circuited stub-loaded uniform impedance resonator. Also, a hairpin SIR geometry is introduced to miniature the size of this filter while maintaining excellent performance. The use of a short-circuited stub at the central point of the hairpin SIR can generate two resonant modes in two passbands. Its equivalent circuit structure is analyzed by using the even-odd mode theory. For demonstration purposes, a tri-band filter for the applications of the Global Positioning System at 1.57 GHz, Worldwide Interoperability for Microwave Access at 3.5 GHz, and wireless local area networks at 5.2 GHz is designed, fabricated, and measured.

Electrochemical Oxidation of Ethanol at Nickel Hydroxide Electrodes in Alkaline Media Studied by Electrochemical Impedance Spectroscopy

  • Kim, Jae-Woo;Park, Su-Moon
    • Journal of the Korean Electrochemical Society
    • /
    • v.8 no.3
    • /
    • pp.117-124
    • /
    • 2005
  • Electrochemical oxidation of ethanol at nickel electrodes has been studied in 1 M KOH solution containing 0.20M ethanol using electrochemical impedance spectroscopy. Equivalent circuits have been worked out by simulating the impedance data, and the results were used to model the oxidation of ethanol as well as the passivation of the electrode. The maximum rate of oxidation of $Ni(OH)_2$ to NiOOH was observed at about 0.37V vs. Ag/AgCl reference electrode, while the maximum rate of ethanol oxidation at the Ni electrode was observed at about 0.42V, The charge-transfer resistance for oxidation of the electrode itself became smaller in the presence of ethanol than in its absence. These results suggest that the $\beta-Ni(OH)_2/\beta-NiOOH$ redox couple is acting as an effective electron transfer mediator far ethanol oxidation. The kinetic parameters also were obtained by the experimental and simulated results.

RF Characteristics of TO-can Packaged FP-LD Optical Transceiver Module (TO-can 패키지 레이저 다이오드 모듈의 주파수 특성 개선)

  • 이동수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.8-12
    • /
    • 2003
  • Characteristics of optical transceiver module in radio frequency(RF) band were investigated with TO-can packaged Fabry-Perot laser diode(FP-LD). R-L-C parameters for equivalent circuit model of the LD were extracted with an impedance analyzer. With this model, impedance matching to the packaged LD could be performed by eliminating inductive components of the leads in the package by using lumped chip capacitors that have opposite reactance, while it shows resonance dip in low frequency band. The resonance dip could be removed using lumped elements for impedance matching by shifting the resonance frequency to the region out of interest.

Impedance spectroscopy analysis of organic light emitting diodes with the $O_2$ anode plasma treatment (저압 산소 플라즈마 처리된 ITO박막을 이용한 유기 EL 소자의 성능 향상에 관한 임피던스 분석)

  • Kim, Hyun-Min;Park, Hyung-June;Lee, Jun-Sin;Oh, Se-Myoung;Jung, Dong-Ggeun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.436-437
    • /
    • 2006
  • In this work, impedance Spectroscopic analysis was applied to study the effect of plasma treatment on the surface of indum-tin oxide (ITO) anodes using $O_2$ gas and to model the equivalent circuit for organic light emitting diodes (OLEDs) with the $O_2$ plasma treatment of ITO surface at the anodes. This device with ITO/TPD/Alq3/LiF/Al structure can be modeled as a simple combination of a resistor and a capacitor. The $O_2$ plasma treatment on the surface of ITO shifts the vacuum level of the ITO as a result of which the barrier height for hole injection at the ITO/organic interface is reduced. The impedance spectroscopy measurement of the devices with the $O_2$ plasma treatment on the surface of ITO anodes shows change of values in parallel resistance ($R_p$) and parallel capacitance ($C_p$).

  • PDF

Real-Time Plasma Process Monitoring with Impedance Analysis and Optical Emission Spectroscopy

  • Jang, Hae-Gyu;Kim, Dae-Kyoung;Kim, Hoon-Bae;Han, Sa-Rum;Chae, Hee-Yeop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.473-473
    • /
    • 2010
  • Plasma is widely used in various commercial etchers and chemical vapor deposition. Unfortunately, real-time plasma process monitoring is still difficult. Some methods of plasma diagnosis is improved, however, it is possible for real-time plasma diagnosis to use non-intrusive probe only. In this research, the object is to investigate the suitability of using impedance analysis and optical emission spectroscopy (OES) for real-time plasma process monitoring. It is assumed that plasma system is a equivalent circuit. Therefore, V-I probe is used for measuring impedance, which can be a new non-intrusive probe for plasma diagnosis. From impedance data, we tried to analyse physical properties of plasma. And OES, the other method of plasma diagnosis, is a typical non-intrusive probe for analyzing chemical properties. The amount of the OES data is typically large, so this poses a difficulty in extracting relevant information. To solve this problem, principal component analysis (PCA) can be used. For fundamental information, Ar plasma and $O_2$ plasma are used in this experiment. This method can be applied to real-time endpoint and fault detections.

  • PDF

Impedance Characterization of Tantalum Oxide Deposited through Pulsed-Laser Deposition

  • Kwon, Kyeong-Woo;Jung, Jin-Kwan;Park, Chan-Rok;Kim, Jin-Sang;Baek, Seung-Hyub;Hwang, Jin-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.207.1-207.1
    • /
    • 2013
  • Tantalum oxide has been extensively investigated as one of the promising Resistive switching materials applicable to Resistive Dynamic Access Memories. Impedance spectroscopy offers simultaneous measurements of electrical and dielectric information, separation of electrical origins among bulk, grain boundaries, and interfaces, and the monitoring of electrical components. Such benefits have been combined with the resistive states of resistive switching devices which can be described in terms of equivalent circuits involving resistors, capacitors, and inductors, The current work employed pulsed laser deposition in order to prepare the oxygen-deficient tantalum oxide. The fabricated devices were controlled between highresistance and low-resistance states in controlled current compliance modes. The corresponding electrical phenomena were monitored both in the dc-based current-voltage characteristics and in the ac-based impedance spectroscopy. The origins of the electrical switching are discussed towards optimized ReRAM devices in terms of interfacial effects.

  • PDF

AC Modeling of the ggNMOS ESD Protection Device

  • Choi, Jin-Young
    • ETRI Journal
    • /
    • v.27 no.5
    • /
    • pp.628-634
    • /
    • 2005
  • From AC analysis results utilizing a 2-dimensional device simulator, we extracted an AC-equivalent circuit of a grounded-gate NMOS (ggNMOS) electrostatic discharge (ESD) protection device. The extracted equivalent circuit is utilized to analyze the effects of the parasitics in a ggNMOS protection device on the characteristics of a low noise amplifier (LNA). We have shown that the effects of the parasitics can appear exaggerated for an impedance matching aspect and that the noise contribution of the parasitic resistances cannot be counted if the ggNMOS protection device is modeled by a single capacitor, as in prior publications. We have confirmed that the major changes in the characteristics of an LNA when connecting an NMOS protection device at the input are reduction of the power gain and degradation of the noise performance. We have also shown that the performance degradation worsens as the substrate resistance is reduced, which could not be detected if a single capacitor model is used.

  • PDF

A Parametric Study on Site Amplification using Equivalent Linear Analysis (등가선형해석을 이용한 지반증폭 영향 요소 연구)

  • 김동수
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.98-107
    • /
    • 2000
  • Free-field ground motion during earthquake is significantly affected by the local site conditions and it is essential for the seismic design to perform the ground response analysis In this study, ground response analyses based on the equivalent linear method were carried out to evaluate the effects of various ground conditions on the site amplification. Four major factors including the depth of the site(very soft and dense soil), the impedance ratio between soil layer and bed rock, linear analysis versus equivalent linear analysis, and the location of soft soil layer were deeply discussed. Based on the analysis results, the importance of various local site conditions on the site amplification was emphasized.

  • PDF

Modal Parameter Estimation of Membrane for Standard Microphone Sensitivity Calibration (표준 마이크로폰 감도 교정을 위한 진동막의 모달 파라미터 측정)

  • 권휴상;서상준;서재갑;박준홍
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.298-302
    • /
    • 2002
  • Equivalent volume estimation of the coupler and two coupled microphones has a key role in standard microphone pressure calibration. The equivalent volume of the microphone is determined by the dynamic characteristics of the diaphragm system and front cavity. Therefore the modal parameters of diaphragm system - natural frequency and damping fatter - should be measured explicitly for the estimation of the equivalent volume. The diaphragm system is composed of the vibrating diaphragm, back slit behind diaphragm, pressure equalization vent, and front cavity which are acoustically coupled. In the measurement, the electrostatic actuator was used to excite the system with the swept sine, and the frequency response was obtained. The close actuator in front of the diaphragm must influence the radiation impedance of the system, and then the modal parameters. From the measured frequency response, the natural frequency and the damping factor could be estimated with the Complex exponential method based on the Prony model and the zero crossing real and imaginary plot.

  • PDF

A Study on Voltage Collapse Mechanism in Electric Power Systems (전력계통에서의 전압붕괴 매카니즘에 관한 연구)

  • Kim, Do-Hyung;Ryu, Heon-Su;Moon, Young-Hyun;Choi, Byoung-Kon;Park, Jung-Do
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.171-174
    • /
    • 2001
  • In this paper, an EMM(Equivalent Mechanical Model) is developed to explain the voltage collapse mechanism by reflecting the effects of reactive powers. The proposed EMM exactly represents the voltage instability mechanism described by the system equations. By the use of the EMM model the voltage collapse mechanism has been illustrated by showing the exactness of the results. It is also discussed a system transform in technique to eliminate the resistance component of the Thevenin equivalent impedance for practical applications.

  • PDF