• 제목/요약/키워드: equivalent damping method

검색결과 175건 처리시간 0.023초

마찰감쇠기가 설치된 비선형 단자유도 건물의 등가감쇠비 (Equivalent Damping Ratio of the Inelastic SDOF Structures with Friction Damper)

  • 김형섭;민경원;이상현;박지훈;문병욱
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.492-499
    • /
    • 2004
  • The purpose of this paper is to present a design procedure of coulomb friction dampers for controlling elastic and inelastic responses of building structures. The equivalent damping and frequency increased by the friction damper are estimated using ATC-40 and ATC-55 procedures which provide equivalent linear system for bilinear one, and then a design formula to achieve target performance response level by friction damper is presented. It is identified that there exists error between the responses obtained by this formula and by performing nonlinear analysis and the features of the error vary according to the hardening ratio, yield strength ratio, and structural period. Equations for compensating this er개r are reposed based on the least square method, and the results from numerical analyses indicate that the error is significantly reduced, and the proposed formula can be used without much error for designing coulomb friction damper for retrofitting a structure showing elastic or inelastic behavior.

  • PDF

표준 마이크로폰 감도 교정을 위한 진동막의 모달 파라미터 측정 (Modal Parameter Estimation of Membrane for Standard Microphone Sensitivity Calibration)

  • 권휴상;서상준;서재갑;박준홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.298-302
    • /
    • 2002
  • Equivalent volume estimation of the coupler and two coupled microphones has a key role in standard microphone pressure calibration. The equivalent volume of the microphone is determined by the dynamic characteristics of the diaphragm system and front cavity. Therefore the modal parameters of diaphragm system - natural frequency and damping fatter - should be measured explicitly for the estimation of the equivalent volume. The diaphragm system is composed of the vibrating diaphragm, back slit behind diaphragm, pressure equalization vent, and front cavity which are acoustically coupled. In the measurement, the electrostatic actuator was used to excite the system with the swept sine, and the frequency response was obtained. The close actuator in front of the diaphragm must influence the radiation impedance of the system, and then the modal parameters. From the measured frequency response, the natural frequency and the damping factor could be estimated with the Complex exponential method based on the Prony model and the zero crossing real and imaginary plot.

  • PDF

Multiple characteristic response damage analysis of large-span space structures based on equivalent damping ratio

  • Wei, Jun;Yang, Qingshun;Zhou, Lexiang;Chen, Fei
    • Earthquakes and Structures
    • /
    • 제23권4호
    • /
    • pp.339-352
    • /
    • 2022
  • Due to the large volume and generally as a public building, the damage of large-span space structures under various non-conventional loads will cause greater economic losses, casualties, and social impacts, etc. Therefore, it is particularly important to evaluate the seismic performance of large-span space structures. This paper taked a multipurpose sports center as an example and considered its synergistic deformation based on the method of equivalent damping ratio. Furthermore, The ABAQUS software was used to analyze the time-history and energy response of the multipurpose sports center under the action of rare earthquakes, and proposed a quantitative damage index to assess the overall damage of the structure. Finally, the research results indicated that the maximum inter-story drift ratio of the multipurpose sports center under the action of rare earthquakes was less than its limit value. The frame beams presented different degrees of damage, but the key members were basically in an elastic state. The bearing capacity did not reach the limit value, which satisfied the intended seismic performance target. This study taked an actual case as an example and proposed a relevant damage evaluation system, which provided some reference for the analysis of the seismic performance of large-span space structures.

Switching Transient Shaping by Application of a Magnetically Coupled PCB Damping Layer

  • Hartmann, Michael;Musing, Andreas;Kolar, Johann W.
    • Journal of Power Electronics
    • /
    • 제9권2호
    • /
    • pp.308-319
    • /
    • 2009
  • An increasing number of power electronic applications require high power density. Therefore, the switching frequency and switching speed have to be raised considerably. However, the very fast switching transients induce a strong voltage and current ringing. In this work, a novel damping concept is introduced where the parasitic wiring inductances are advantageously magnetically coupled with a damping layer for attenuating these unwanted oscillations. The proposed damping layer can be implemented using standard materials and printed circuit board manufacturing processes. The system behavior is analyzed in detail and design guidelines for a damping layer with optimized RC termination network are given. The effectiveness of the introduced layer is determined by layout parasitics which are calculated by application of the Partial Element Equivalent Circuit (PEEC) simulation method. Finally, simulations and measurements on a laboratory prototype demonstrate the good performance of the proposed damping approach.

결합부 유연성에 따른 감쇠거동에 관한 고찰 : 히스테레틱 감쇠 (Estimations of the Hysteretic Damping by Controlled Joint Flexibilities)

  • 윤성호
    • 소음진동
    • /
    • 제9권2호
    • /
    • pp.258-264
    • /
    • 1999
  • The purpose of this paper is to investigate the damping behavior of a flexible joint. The slip at a structrual joint is selected at the tips of two identical cantilever beams adjoining each other. Both the direction of normal force and its magnitude varies due to the global deformation of the structure from mode to mode in the friction model. The friction dependent on vibration displacements resultsin the same functional behavior of the hysteretic material damping. Linearized energy loss factors are obtained as functions of both linear and torsional spring stiffness for their groups of symmetric and anti-symmetric modes, respectively. Experimental measurements as made for comparisons with analytical estimations by controlling the magnitude of fastening torque in the fastener, Hi-Lite. Trends on damping levelsmeasured in a very common vibration test method make an excellent agreement on the estimated damping levels.

  • PDF

보행하중을 받는 건축물 바닥판의 진동해석 (Vibration Analysis of Building Floor Subjected to Walking Loads)

  • 김기철;이동근
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.414-421
    • /
    • 2001
  • Recently, the damping effect of building structures are greatly reduced because the use of non-structures members as like curtain wall are decreased and large open space are in need for the service of buildings. Assembly and office buildings with a lower natural frequency have a higher possibility of experiencing excessive vibration induced by human activities as like jumping, running and walking. These excessive vibration make the occupants uncomfortable and the serviceability deterioration. The common method of application of walking loads for the vibration analysis of structures subjected to walking loads is to inflict a series unit walking load and a periodic function at a node. But this method could not consider the moving effect of walking. In this study, natural frequency and damping ratio of plate structure are evaluated by heel drop tests. And new application of equivalent walking loads are introduced for vibration analysis of real slab system subjected to walking loads. The response obtained from the numerical analysis are compared well to the results measured by experimental tests. It is possible to efficiently analyze the vibration of floor which is subjected to walking loads by applying equivalent walking loads.

  • PDF

성능목표를 달성하기 위한 점탄성 감쇠기의 설계 (Design of Viscoelastic Dampers to Meet Performance Objectives)

  • 김진구;최현훈
    • 한국전산구조공학회논문집
    • /
    • 제15권2호
    • /
    • pp.329-339
    • /
    • 2002
  • 본 연구에서는 비선형 정적해석법인 능력스펙트럼 법을 이용하여 성능목표를 만족하기 위하여 필요한 점탄성 감쇠기를 설계하는 절차를 제시하였다. 점탄성 감쇠기의 적정 크기를 구하기 위해 목표 변위에서 필요한 유효감쇠 비를 구한 다음 구조물의 이력거동에 의한 등가감쇠 비와 고유감쇠 비를 이용하여 필요한 감쇠기의 감쇠를 구하였다. 점탄성 감쇠기를 설치할 경우에는 구조물의 감쇠뿐만 아니라 강성도 변화하기 때문에 반복계산이 필요하게 된다. 본 연구에서는 먼저 단자유도계에서 구조물의 설계변수를 변화시키면서 제안된 방법의 타당성을 검증하였다. 또한 10층의 철골조 건물에 적용하고 지진응답을 구하였다. 제안된 방법에 따라 설계된 감쇠기를 설치하고 수행한 시간이력해석 결과에 의하면 고려된 설계변수에 관계없이 목표변위를 만족하는 것으로 나타났다.

지진하중을 받는 구조물의 성능에 기초한 마찰감쇠기 설계 (Performance Based Design of Friction Dampers for Seismically Excited Structures)

  • 민경원;김형섭
    • 한국지진공학회논문집
    • /
    • 제7권6호
    • /
    • pp.17-24
    • /
    • 2003
  • 이 논문의 주된 목적은 지진을 받는 구조물의 비탄성 거동을 제어하기 위해 Coulomb 마찰감쇠기의 제어성능을 산출하는 것이다. 능력스펙트럼법을 이용하여 다양한 건물의 내진성능이 평가되나, 만약 평가된 성능수준이 목표수준에 미치지 못할 때는 추가적인 감쇠비를 산출하게 된다. 추가적인 감쇠비를 얻기 위한 마찰감쇠기의 리더 마찰력은 등가 점성 감쇠의 개념을 사용하여 산정된다. 이와 같이 제안된 방법의 효과를 증명하기 위해, 다양한 주기와 항복 후 강성비를 가진 단자유도 구조물들에 대하여 수치해석을 수행하였다.

Evaluation and Comparison of the Low-Frequency Oscillation Damping Methods for the Droop-Controlled Inverters in Distributed Generation Systems

  • Tao, Yong;Deng, Yan;Li, Guangdi;Chen, Guipeng;He, Xiangning
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.731-747
    • /
    • 2016
  • The droop-based control strategy is widely applied in the interfacing inverters for distributed generation. This can be a problem since low-frequency stability issues may be encountered in droop-based microgrid. The objective of this paper is to classify, evaluate and compare various low-frequency damping methods. First, low-frequency stability problems are analyzed and an equivalent model of a droop-controlled inverter is investigated to classify the damping methods into the source-type damping strategies and the impedance-type damping strategies. Moreover, the lead-lag compensation network insertion control is proposed as a beneficial part of the source-type damping strategies. Then, the advantages and disadvantages of the different types of damping methods are theoretically evaluated and experimentally tested. Furthermore, the damping methods are comprehensively compared to illustrate the application field of each method. Finally, the synthesis of different damping methods to enhance the low-frequency stability is discussed and experimental validation is presented.

Seismic equivalent linear response of a structure by considering soil-structure interaction: Analytical and numerical analysis

  • Maroua Lagaguine;Badreddine Sbartai
    • Structural Engineering and Mechanics
    • /
    • 제87권2호
    • /
    • pp.173-189
    • /
    • 2023
  • For a given structural geometry, the stiffness and damping parameters of the soil and the dynamic response of the structure may change in the face of an equivalent linear soil behavior caused by a strong earthquake. Therefore, the influence of equivalent linear soil behavior on the impedance functions form and the seismic response of the soil-structure system has been investigated. Through the substructure method, the seismic response of the selected structure was obtained by an analytical formulation based on the dynamic equilibrium of the soil-structure system modeled by an analog model with three degrees of freedom. Also, the dynamic response of the soil-structure system for a nonlinear soil behavior and for the two types of impedance function forms was also analyzed by 2D finite element modeling using ABAQUS software. The numerical results were compared with those of the analytical solution. After the investigation, the effect of soil nonlinearity clearly showed the critical role of soil stiffness loss under strong shaking, which is more complex than the linear elastic soil behavior, where the energy dissipation depends on the seismic motion amplitude and its frequency, the impedance function types, the shear modulus reduction and the damping increase. Excellent agreement between finite element analysis and analytical results has been obtained due to the reasonable representation of the model.