• Title/Summary/Keyword: environmental cleaner

Search Result 146, Processing Time 0.03 seconds

Recent Developments in the Law Relating to Maritime Safety and Environmental Protection

  • James, Jim
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.2 no.1
    • /
    • pp.125-135
    • /
    • 1996
  • I hope that in the limited allotted to me today I managed to draw to your attention just some of the recent legal developments relation to international maritime safety and environmental protection or more simply, of safer ships and cleaner seas, none of us should be in any doubt the ever increasing pressure that is going to be placed upon the shipping industry to achieve the objectives to which those expressions refer.

  • PDF

Development of a Potable Skimmer(II) - Fabrication and Performance Test of an Air Suction Skimmer (휴대용 유출기름회수기의 개발(II) - 공기흡입회수기의 제작과 성능시험)

  • 박외철
    • Journal of Environmental Science International
    • /
    • v.3 no.2
    • /
    • pp.177-184
    • /
    • 1994
  • An air suction skimmer was selected as a potable skimmer to be developed among the many reviewed skimmers because of its advantages such as simple structure, excellent transportability, and easy deployment. A prototype of the skimmer was fabricated. It was shown that the skimmer operated by a commercial vacuum cleaner has good performance. The maximum suction rate of water and the maximum suction head were 18$m^3$/hr and 2.7m, respectively.

  • PDF

Removal Efficiency of Pesticide Residues on Apples by Ultrasonic Cleaner (초음파 세척기를 이용한 사과의 잔류농약 제거 효과)

  • Yoon, Chae-Hyuk;Park, Woo-Churl;Kim, Jang-Eok;Kim, Chung-Hyo
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.3
    • /
    • pp.255-258
    • /
    • 1997
  • In order to determine the removal efficiency of pesticide residues on apples by ultrasonic cleaner, apples(Fuji var.) were artificially treated by dipping in water solution of fenitrothion EC, chlorpyrifos EC and phenthoate EC. The treated apples were washed by the ultrasonic cleaner with water, 30% ethanol solution or 0.2% detergent solution, respectively. The removal efficiency of fenitrothion, chlorpyrifos and phent-hoate by ultrasonicated washing in water for 0.5min. was 39.2%, 32.0% and 50.4%, respectively, but there was a tendency to decrease the removal efficiency of the pesticide residues as the duration of ultrasonicated washing period is increased. The maximum removal efficiency of the pesticide residues washed in the detergent solution was observed by ultrasonicated washing the samples for 5min. and it was recorded as 33.5% ; fenitrothion, 30.1% ; chlorpyrifos and 48.3% ; phenthoate, respectively. However it's appeared that the longer the ultrasonicated washing period in 30% ethanol solution the more pesticides from the apples were removed and the maximum removal efficiency of the pesticides was recorded as 66.2%(fenitrothion ; washed for 15min.), 41.7%(chlorpyrifos ; washed for 10min.), 74.2%(phenthoate ; washed for 10min.).

  • PDF

Characteristics of a Wet Air Cleaning System for Removal of Air Pollutants (습식 공기청정장치의 공기오염물질 제거 특성)

  • Bae, Gwi-Nam;Kim, Yong Pyo;Baik, Nam Jun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.1
    • /
    • pp.21-31
    • /
    • 2000
  • Performance characteristics of a wet air cleaning system were investigated experimentally, and discussed in relation with physicochemical properties of the target pollutants. The system is composed of an air cleaner, a separator, and a medium filter. Removal efficiency of the system was measured for ambient particles and gaseous air pollutants: $SO_2$, NO, $NO_2$, HCHO, and $NH_3$. For particle removal test, particles were introduced into the system through a fan, and the particle size distribution was measured at three locations by using two laser particle counters. Particle removal efficiency for each system component was obtained from the particle size distribution. It was found that the separator primarily removed coarse particles greater than $5{\mu}m$ in diameter, and that the medium filter mainly removed fine particles less than $5{\mu}m$ in diameter. For gas removal test, air with gaseous air pollutant was injected into the outlet of the fan, and the concentration was measured both at the upstream of the air cleaner and at the downstream of the separator. It was found that the gaseous species with high Henry's law coefficients, such as $SO_2$, HCHO, and $NH_3$, showed high removal efficiency, but the gaseous species with low Henry's law coefficients, such as NO and $NO_2$, showed low removal efficiencies. It was also found that negative ions were generated from the air cleaner.

  • PDF

The Effect of STEAM Program using Arduino on Preservice Science Teachers' STEAM Core Competencies (아두이노를 활용한 STEAM 프로그램이 예비 과학교사의 융합인재 핵심역량에 미치는 영향)

  • Kim, Sun Young;Hyun, Yun Se
    • Journal of Science Education
    • /
    • v.44 no.2
    • /
    • pp.183-196
    • /
    • 2020
  • This study explores the effects of STEAM program using Arduino on preservice science teachers toward their STEAM core competencies. The STEAM program using Arduino consists of four stages: presentation of situation, creative design, emotional touch, and evaluation. The preservice science teachers learned the theoretical backgrounds of STEAM and Arduino. Then, they were given the chance to think about an environmental issue, which is fine dust. The preservice teachers designed an air cleaner and a fine dust measuring instrument using Arduino. The preservice science teachers also produced the air cleaner and the measuring instrument using Arduino. They measured the level of fine dust in the classroom before and after the use of the air cleaner. That is, the preservice teachers experienced each stage of STEAM: seriousness of fine dust, design and production of the measuring instrument of fine dust and air cleaner, and evaluation of the effectiveness of air cleaner. Further, they reflected on their experiences of STEAM program using Arduino. The results indicate that these preservice science teachers statistically improved communication competency, problem-solving competency, gathering information competency, logical analytical thinking competency, and creativity competency. However, there were no statistical improvements on teamwork competency and self-development competency. This study suggests that experiencing STEAM program using Arduino is valuable for the preservice science teachers to develop STEAM core competencies and further implement STEAM program their science classes in the future.

Reduction Effect of Air Cleaner on Particulate Matters and Biological Agents in a Swine Facility (공기정화기 적용에 따른 돈사 작업장내 입자상 물질 및 생물학상 물질 저감 효과에 관한 연구)

  • Kim, Ki Youn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.1
    • /
    • pp.70-76
    • /
    • 2017
  • Objectives: This on-site study was performed to evaluate the reduction efficiency of an air cleaner on particulate matters and biological agents in a swine facility. Materials and Methods: Particulate matter was measured using a real-time monitoring recorder and biological agents were sampled with a one-stage impactor and then analyzed based on the microbial culture method. An experimental process for the reduction effect on airborne pollutants through air cleaner operation consisted of three conditions: no treatment, wet scrapper by water spray and wet scrapper by disinfectant spray. Results: Geometric mean levels of particulate matter(TSP, $PM_{10}$, $PM_{2.5}$ and $PM_1$) were presented at $1,608{\mu}g/m^3$, $1,373.8{\mu}g/m^3$, $401.8{\mu}g/m^3$ and $144.5{\mu}g/m^3$ for no treatment; $1,503{\mu}g/m^3$, $1,017{\mu}g/m^3$, $159.4{\mu}g/m^3$ and $69.8{\mu}g/m^3$ for wet scrapper by water spray; and $1,222.17{\mu}g/m^3$, $477.17{\mu}g/m^3$, $33.2{\mu}g/m^3$ and $11.1{\mu}g/m^3$ for wet scrapper by disinfectant spray, respectively. In the case of biological agents, the geometric averaged concentrations of total airborne bacteria and fungi were as follows: $45,371cfu/m^3$ and $13,474cfu/m^3$ for no treatment, $43,286cfu/m^3$ and $8,610cfu/m^3$ for wet scrapper by water spray, and $2,440cfu/m^3$ and 1,867 cfu/ for wet scrapper by disinfectant spray, respectively. Regardless of particulate matter and biological agent, the highest concentrations were found for no treatment, while the lowest concentrations were found with wet scrapper by disinfectant spray. Conclusions: Based on the results obtained from this on-site evaluation, there was a significant reduction effect on particulate matter and biological agents through the application of an air cleaner in this study.

Application of Life Cycle Assessment for Cleaner Production of Paper Products (종이제품의 청정생산을 위한 LCA기법의 적용)

  • Hwang, Yong-Woo;Jo, Byoung-Muk;Kim, Hyoung-Jin;Park, Kwang-Ho
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2002.11a
    • /
    • pp.228-233
    • /
    • 2002
  • In this study, Life Cycle Assessment method has been carried out the Corrugated board box in considering environmental aspects by quantifying the environmental emission and assessing its environmental impact potential. The system boundary in this study is selected from cradle to gate stage(raw material acquisition, raw material production and product manufacturing) of the paper product. To evaluate the environmental impact potential, impact categories are divided into 8 categories. As a results, abiotic resource depletion of the impact categories has the largest contribution to the total impact potential as 31.02% of total, Next were continued ecotoxicity having a contribution of 27.17%. In the life cycle, environmental impacts from law material production stage were contributed largely as 80.78%.

  • PDF

VOCs Concentrations of Indoor and Outdoor in Solvent Thinner-Using Occupation, and Application of TiO$_2$ Photocatalytic Air Cleaner

  • Wonho Yang;Joon Cho;Busoon Son;Park, Jongan
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.1.1-2
    • /
    • 2002
  • Ultimate objective of industrial hygiene is the prevention of health impairment that may result from exposure to chemicals at workplaces. This implies the definition of permissible levels of exposure, that is, levels that according to the present status of knowledge are estimated to cause no adverse health effects during the lifetime of the workers, and the regular assessment of the possible health risk associated with exposure by comparing the current or the integrated exposure with the permissible exposure limits. Workers in solvent thinner-using occupation environment might be highly exposed to VOCs(volatile organic compounds) because solvent thinner has been used extensively such as painting, spraying, degreasing, coating and so on in Korea. The purpose of this study was to recognize, evaluate and propose the alternative control the VOCs from solvent thinner-using workplace.

  • PDF

Effect of Energy Consumptuon on Air Pollution in I.R.Iran

  • Ayati, B.;Ganjidoust, H.
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.43-46
    • /
    • 2003
  • The economy of I.R.Iran is so related to oil that has had many environmental problems especially air pollution in urban areas in recent years. Statistics show that most of the time, the condition of air quality is in crisis level especially during fall and winter seasons. Rapid and high population growth has had large amount of fossil fuels consumption in all sectors including transportation, industry, agriculture, residential and commercial and public services and air pollution and healthy problems. Iran's abundance of fossil fuel resources has tended to discourage the country's incentive to shift to cleaner alternative energy sources for its energy needs that must be considered in future programming. These are discussed in this paper.

  • PDF

Occurrence of Phthalates in Indoor Dust from Children's Facilities and Apartments in Seoul

  • Kim, Ho-Hyun;Lim, Young-Wook;Yang, Ji-Yeon;Shin, Dong-Chun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.5
    • /
    • pp.382-391
    • /
    • 2009
  • The aim of the study was to assess the levels in typical central borough of phthalate exposure by monitoring children's facilities (19 kindergartens and 21 elementary schools) and households (17 old apartments and 22 new apartments) via sampling indoor floor dust. A vacuum cleaner specifically prepared for sampling dust was attached to a filter of a vacuum cleaner dust collecting container. During the sample preparation process, containers made of glass were used and analysis was performed using GC-MSD. The mean concentration of DEHP was $412{\mu}g/g$, DnBP was $24{\mu}g/g$, and BBzP was $10{\mu}g/g$ dust. The indoor characteristics including floor, wall materials, years after construction, water leakage history for the past three years, and ventilation were also examined to categorize phthalate esters from the dust samples. From the flooring and wallpaper materials of kindergartens and elementary schools, DEHP in the dust sample appeared at a statistically significant level (p<0.05) when PVC materials were present. DEHP in the indoor dust also increased significantly (p<0.01) during the construction period. The daily intake of DEHP measured from indoor dust was 0.08~$19.7{\mu}g/kg/day$ for children and 0.02~$1.1{\mu}g/kg/day$ for adults (women). The results clearly revealed that phthalate exposure is greater in children than in adults (women) due to the indoor dust.