• Title/Summary/Keyword: environmental chamber

Search Result 903, Processing Time 0.033 seconds

Sensitivity Study of the Flow-through Dynamic Flux Chamber Technique for the Soil NO Emissions

  • Kim Deug-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.E3
    • /
    • pp.75-85
    • /
    • 2005
  • A mathematical sensitivity analysis of the flow-through dynamic flux chamber technique, which has been utilized usually for various trace gas flux measurement from soil and water surface, was performed in an effort to provide physical and mathematical understandings of parameters essential for the NO flux calculation. The mass balance equation including chemical reactions was analytically solved for the soil NO flux under the steady state condition. The equilibrium concentration inside the chamber, $C_{eq}$, was found to be determined mainly by the balance between the soil flux and dilution of the gas concentration inside the chamber by introducing the ambient air. Surface deposition NO occurs inside the chamber when the $C_{eq}$ is greater than the ambient NO concentration ($C_{0}$) introducing to the chamber; NO emission from the soil occurs when the $C_{eq}$ is less than the ambient NO concentration. A sensitivity analysis of the significance of the chemical reactions of NO with the reactive species (i.e. $HO_{2},/CH_{3}O_{2},/O_{3}$) on the NO flux from soils was performed. The result of the analysis suggests that the NO flux calculated in the absence of chemical reactions and wall loss could be in error ranges from 40 to $85\%$ to the total flux.

Analysis of Characteristics of Coupled Phosphorus in the Sewage (하수 중 인의 결합 특성 분석)

  • Choi, Hee-Jeong;Lee, Seung-Mok
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.1
    • /
    • pp.97-102
    • /
    • 2007
  • The present investigation deals to achieve an accurate determination of the phosphorous present in the wastewater samples using the membrane reactor. The study may enable to quantify the dissolved (DP) and adsorbed phosphorous (AP), also the adsorbed phosphorous categorically identified as inorganic coupled phosphorous (DRP) and organic coupled phosphorous (NRP). Moreover, the study has been conducted separately in anaerobic and aerobic chamber. The results obtained showed that dissolved phosphorous only can occur in anaerobic chamber with ca. 25%. The study conducted for adsorbed phosphorous showed that the DRP has the percent composition in anaerobic and aerobic chamber respectively 33% and 40% i.e., 7% more in aerobic chamber. The similar values obtained for NRP was found to be 42% and 60% i.e., 18% more in aerobic chamber. On the other hand while comparing the results for NRP and DRP, it has to be noted that NRP has 9% and 20% more percent composition than DRP respectively in anaerobic and aerobic chamber. Further, the adsorbed phase showed the species Al-P, Fe-P in the aerobic chamber with the quotient of 7.73 mg/g TS (total solid) whereas in the anaerobic chamber it showed the species Fe-P and $Fe(OH)_3$-P with the 7.16 mg/g TS.

Generation and Decay Phenomena of Environmental Tobacco Smoke in Controlled Experimental Atmosphere Chamber (환경이 조절되는 Chamber 내에서 Environmental Tobacco Smoke의 생성과 감소 현상)

  • 이문수;나도영;안기영;이규서
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.18 no.2
    • /
    • pp.170-176
    • /
    • 1996
  • This paper describes the generation and decay phenomena of gas, vapor and particulate phase components of environmental tobacco smoke in 18 m3 controlled experimental atmosphere chamber. Real time-weighted average concentration ratios of markers were determinated at no ventilation rates and sampling durations of starting to smoking 45 min. Average concentration of major ETS markers was no significant on the mainstream smoke contents of commercial cigarette and decay ratios were dependent on first order kinetic. RSP/nicotine, solanesol and 3-EP were good predictors of ETS concentration in the public indoor field. The concentration ratio of vapor phase and particulate phase components is highly variable to assessment of indoor air quality with ETS. Key words : ETS, chamber study, ETS markers.

  • PDF

An Analysis of Attenuation Effect of Pressure Head Using an Air Chamber

  • Lee, Jae-Soo;Yoon, Yong-Nam;Kim, Joong-Hoon
    • Korean Journal of Hydrosciences
    • /
    • v.7
    • /
    • pp.77-86
    • /
    • 1996
  • An air chamber is design to keep the pressure from exceeding a predetermined value, or to prevent low pressures and colum separation. Therefore, it can be used to protect against rapid transients in a pipe system following abrupt pump stoppage. In this research, an air chmber was applied to a hypthetical pipe system to analyze attenuation effect of pressure head for different air volumes, locations, chamber areas, coefficients of orifice loss and pollytropic exponents. With an increase of air volume, the maximum pressure head at pump site is decreased and the minimum pressure head is imcreased. For different locations and areas of the chamber, the attenuation effects do not show much difference. Also, as the orifice loss coefficient increases, the maximum pressure head is decreased. For different polytropic exponents, isothermal process shows lower maximum pressure head than that of the adiabatic process.

  • PDF

Emission Estimation and Exposure to Hazardous Gaseous Pollutants Associated with Use of Air Fresheners Indoors (실내 방향제 사용에 의한 유해 가스상 오염물질 배출 산정 및 노출 평가)

  • Jo, Wan-Kuen;Shin, Seung-Ho;Kwon, Gi-Dong;Lee, Jong-Hyo
    • Environmental Analysis Health and Toxicology
    • /
    • v.24 no.2
    • /
    • pp.137-148
    • /
    • 2009
  • This study quantitatively investigated the emissions of indoor air pollutants associated with the utilization of air fresheners indoors, and evaluated individual exposure to five specified indoor air pollutants, which were chosen on the basis of selection criteria. An electrically-polished stainless steel chamber (50L) was employed to achieve this purpose. Test air fresheners were selected through three steps: first, on the basis of market sales; second, on the basis on a preliminary head-space study; and lastly, on the basis of emissions of toxic compounds (benzene, ethyl benzene, limonene, toluene, and xylene). The empirical mathematical model fitted well with the time-series concentrations in the environmental chamber (in most cases, determination coefficient, $R^2{\gtrsim}$0.9), thereby suggesting that the empirical model was suitable for testing emissions. The concentration equilibrium appeared 180 min after the introduction of sample air fresheners into the chamber. Both the chamber concentrations of emission rates or factors varied greatly according to air freshener type. It is noteworthy that although benzene, ethyl benzene, toluene, and xylene were emitted from all test air fresheners, their exposure levels were not significant enough to result in any significant health risk. However, certain type of air fresheners were observed to emit significant amount of limonene, which is potentially reactive with ozone to generate secondary pollutants with oxidants such as ozone, hydroxyl radicals, and nitrogen oxides. The exposure levels to limonene associated with the utilization of three air fresheners were estimated to be 13 to 175 times higher than that of other air fresheners. This information can help consumers to select low-pollutant-emitting air fresheners.

Fuzzy Self-Organizing Control of Environmental Temperature Chamber (온도챔버의 퍼지 자동조정 제어시스템)

  • 김인식;권오석
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.1
    • /
    • pp.34-40
    • /
    • 1994
  • The design and implementation of a fuzzy self-organizing controller for an environmental temperature chamber is discussed. The chamber is a non-linear, time-variant system with delay-time and dead-time. And the parameter tuning is required in PI control when the performance degraded. However the proposed fuzzy-SOC monitors the performance of the process. modifies the data base, and performs the delay-time compensation based on the idealized process model. A series of experiments was performed for the conventional PI and the fuzzy-SOC. These experimental results show the usefulness of the fuzzy-SOC.

  • PDF

Vibration Isolation System of a Large Reverberation Chamber (대형 잔향실의 방진 설계 및 검증)

  • 김영기;김홍배;이동우;우성현;문상무
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.1026-1031
    • /
    • 2003
  • A vibration isolation system fur a large reverberation chamber (1,228㎥, 1,000ton) has been installed. The reverberation chamber generates loud noise and induces high level of vibration to perform spacecraft acoustic environmental tests. The isolation system prevents vibration transfer from the chamber to enclosure buildings. This paper describes logical design process and commissioning experiments of the system. Design criteria have been induced from rigid body model of the chamber. Finite element model has been employed to select the characteristics of rubber pads. A total of 21 rubber pads have been installed between the chamber and supporting pedestals. A sand bag of 800kg was dropped on the chamber floor to measure the natural frequency of the isolation system. Absolute transmissibility has been measured while generating 145㏈ in the chamber. The natural frequency of the chamber is 10.5㎐, which is 80% of estimated value. Overall transmissibility at working frequency range (25㎐-10,000㎐) is less than -6㏈.

  • PDF

Measurement Uncertainty of Methane Concentrations from a Rice Paddy Measured by a Closed Automated Chamber System (벼논에서 폐쇄형 자동 챔버 시스템으로 측정한 메탄 농도에 대한 요인별 측정 불확도 비교)

  • Ju, Ok Jung;Kang, Namgoo;Lim, Gap June
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.3
    • /
    • pp.228-236
    • /
    • 2020
  • BACKGROUND: The closed chamber method is the most commonly used for measuring greenhouse gas emissions from rice fields. This method has the advantages of being simple, easily available and economical. However, a measurement result using the chamber method is an estimated value and is complete when the uncertainty is estimated. The methane emissions from a rice paddy account for the largest portion of the greenhouse gas emissions in the agriculture sectors. Although assessment of uncertainty components affecting methane emission from a rice paddy is necessary to take account of dispersion characteristics, research on these uncertainty components is very rare to date. The goal of this study was to elucidate influencing factors on measurement uncertainty of methane concentrations measured by a closed automated chamber system from a rice paddy. METHODS AND RESULTS: The methane sampling system is located in the rice paddy in Gyeonggi-do Agricultural Research and Extension Services (37°13'15"N, 127°02'22"E). The primary measurement uncertainty components influencing methane concentrations (influencing factors) investigated in this research were repeatability, reproducibility and calibration in the aspects of methane sampling and analytical instrumentation. The magnitudes of the relative standard uncertainty of each influencing factor were quantified and compared. CONCLUSION: Results of this study showed what influencing factors were more important in determination of methane concentrations measured using the chamber system and analytical instrumentation located in the monitoring site. Quantifying the measurement uncertainty of the methane concentrations in this study would contribute to improving measurement quality of methane fluxes.

Effect of infiltration/inflow by rainfall for sewerage facilities in the area with partially separate sewer system (불완전 분류식 하수처리구역의 강우에 의한 하수도시설의 침입수/유입수 영향 분석)

  • Shin, Jungsub;Han, Sangwon;Yook, Junsu;Lee, Chungu;Kang, Seonhong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.3
    • /
    • pp.177-190
    • /
    • 2019
  • The purpose of this study was to analyze the effects of sewerage facilities through I/I analysis by rainfall by selecting areas where storm overflow diverging chamber is remained due to the non-maintenance drainage equipment when the sewerage system was reconstructed as a separate sewer system. Research has shown that wet weather flow(WWF) increased from 106.2% to 154.8% compared to dry weather flow(DWF) in intercepting sewers, and that the WWF increased from 122.4% to 257.6% in comparison to DWF in storm overflow diverging chamber. As a result, owing to storm overflow diverging chamber of partially separate sewer system with untreated tributary of sewage treatment plant, rainfall-derived infiltration/inflow(RDII) has been analyzed 2.7 times higher than the areas without storm overflow diverging chamber. Meanwhile, infiltration quantity of this study area was relatively higher than that of other study areas. Therefore, it is necessary to reduce infiltration quantity through sewer pipe maintenance nearby river. Drainage equipment maintenance should be performed not to operate storm overflow diverging chamber in order to handle the appropriate sewage treatment plant capacity for rainfall because it is also expected that RDII due to rain will occur after maintenance. In conclusion, it is necessary to recognize aRDII(allowance of rainfall-derived infiltration/inflow) and to be reflected it on sewage treatment plant capacity because aRDII can occur even after maintenance to the complete separate sewer system.

A Study on the Variation of Ventilation Effect for Indoor Air Pollutants by Ventilation Hole Sites (환기구 위치별 실내오염물질의 환기효과 변동에 관한 연구)

  • Lee, Jeong Joo;Lee, Ju Sang;Kim, Shin Do
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.226-240
    • /
    • 1995
  • This research has a purpose to achieve experimental data used for design of ventilation systems necessary for indoor air quality control and their operation and management. For the study, spatial concentration distribution of indoor air quality according to pollutant site in a simplified model chamber. In low flow ventilation, flow pattern of indoor air was mainly influenced by diffusion and additionally, spatial distribution was formed by convection. Distribution of ventilation efficiency according to each pattern of model chamber was evaluated. It was confirmed that diffusion patterns of a pollutant among sites were formed, centering around main stream areas of supply and exhaust outlets.

  • PDF