• Title/Summary/Keyword: environmental VOCs

Search Result 655, Processing Time 0.028 seconds

Emission of Air Pollutants from Agricultural Crop Residues Burning (농업잔재물 소각에 의한 대기오염물질의 배출 특성)

  • Park, Seong-Kyu;Hong, Young-Shil;Kim, Daekeun;Kim, Dong Young;Jang, Young Kee
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.1
    • /
    • pp.63-71
    • /
    • 2015
  • The gaseous and particulate emissions from agricultural crop residues burning were investigated. The test residues included white soybean stem, pepper stem, apple branch, peach branch, pear branch, grape branch, sesame stem, perilla stem, and barley stem. Particulate emissions were dominated by fine particles (< $0.1{\mu}m$ in size). The highest $PM_{2.5}$ Emission factors were from barley stems (35.2 g/kg), and the lowest from pepper stems (7.9 g/kg). Emission factors for CO, NO, and VOCs were 146~305 g/kg, 4.94~15.02 g/kg, 27.4~353.3 g/kg, respectively. Benzene played an important role in VOCs emissions from biomass burning.

The Study on the Emission Characteristics of HAPs and PM from the Motor Vehicle Paint Facility (자동차 도장시설에서 발생하는 유해대기오염물질 및 미세먼지의 배출특성에 관한 연구)

  • Kim, Han-Na;Bong, Choon-Keun;Kim, Yong-Gu;Jeon, Jun-Min
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.6
    • /
    • pp.713-721
    • /
    • 2013
  • This study is about emission characteristics of HAPs and particulate matters emitted by spray of paint and organic solvent usually used in vehicle paint facilities. To analyze emission characteristics of HAPs and particulate matters emitted from vehicle paint facilities are calculated based on the measuring emission quantity of pollutants based on the amount of paint used (kg) and unit area ($m^2$) by paint manufacturers (J company, K company, and R company). In cases of paint manufacturers (J, K, and R), average emission factors of VOCs, carbonyl compound, particulate matter, and PAHs per 1 kg of paint were 327.81 g/kg, 5.98 g/kg, 336.70 g/kg, and 0.0078 g/kg respectively. The average emission factors of VOCs, carbonyl compounds, particulate matters, and PAHs by unit area were $171.55g/m^2$, $3.10g/m^2$, $176.27g/m^2$, and $0.0036g/m^2$ respectively.

The photo-removal characteristic of VOCs by photocatalyst/scoria/loess concrete (광촉매가 첨가된 스코리아/황토/콘크리트의 VOCs 제거특성)

  • Ko, Seong-Hyun;Lee, Jae-Hoon;Hong, Chong-Hyun;Ryu, Seong-Phil;Kim, Moon-Hoon;Moon, Kyung-Jong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.585-588
    • /
    • 2006
  • The environment-friendly building material, photocatalyst/scoria/loess concrete, was prepared using scoria and loess (which have merits as building materials) and photocatalyst (which has the functions to compose the environmental contaminants and of self cleaning). In order to apply this material as a building material, the compressive and flexible strengths, and water absorptivity (which have been set by Korea Industrial Standard) were measured. The optimum mixing ratio of photocatalyst/scoria/loess concrete was obtained at the condition of $393kg/m^3$ of coarse aggregate, $802kg/m^3$ of fine aggregate in case of scoria, $80kg/m^3$ of loess, $12kg/m^3$ of photocatalyst, $400kg/m^3$ of cement, and $2kg/m^3$ of AE water reducing agent. The photocatalyst/scoria/loess concrete prepared by above mixing ratio of raw materials showed 25 MPa of compressive strength, $3.8{\sim}4.6$ MPa of flexible strength and $11.4{\sim}12.0%$ of water absorptivity, indicating that the quality of this material was suitable for Korea Industrial Standard (more than 21 MPa for compressive strength, more than 2.0 MPa for flexible strength in case of lightweight aggregate, and less than 15 % for water absorptivity in case of clay brick) for using as a building material.

  • PDF

Biological Removal of a VOC Mixture in a Two-stage Bioreactor (이단미생물반응조에서 혼합 VOCs의 생분해 특성)

  • Song, Ji-Hyeon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.758-766
    • /
    • 2006
  • A two-stage bioreactor, which consists of a biotrickling filter module and a biofilter module in series, was investigated for the enhanced treatment of a VOC mixture, toluene and methyl ethyl ketone (MEK). Throughout the experiments, the overall inlet loading rate was maintained at approximately $43g/m^3/hr$, but the inlet ratios of the VOCs were modified. The experimental results showed that the different ratios of the VOC mixture resulted in changes of overall removal efficiencies, elimination capacities (ECs) and microbial accumulation on the surface of each packing material. The ratio of inlet toluene to MEK at 50 : 150 was found to be most effective in terms of the overall removal efficiency, because, at this condition, MEK (i.e., the hydrophilic compound) was mostly removed in the biotrickling filter module and the following biofilter module was used to remove toluene. It was also found that when the inlet loading rate of the VOC mixture was serially increased stepwise within short-term periods, the ECs for toluene dropped significantly but the ECs for MEK increased at the ratio of the VOC mixture. These results implied that substrate interaction and/or substrate preferable utilization might have an effect on the biological removal of each compound in the two-stage bioreactor; therefore, the bioreactor should be operated in the condition where the substrate interaction could be minimized in order to maximize overall performance of the two-stage bioreactor.

Rapid Determination of Volatile Organic Compounds in Human Whole Blood Using Static Headspace Sampling with Gas Chromatography and Mass Spectrometry

  • Lee, Ji-Young;Kim, Seungki;Lee, Jong-Tae;Choi, Jong-Ho;Lee, Jeongae;Pyo, Heesoo
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.12
    • /
    • pp.3963-3970
    • /
    • 2012
  • Headspace (HS) and headspace solid-phase microextraction (HS-SPME) were studied for extracting volatile organic compounds (VOCs) from whole blood, with chemical and instrumental variables being optimized for maximum sensitivity: incubation at $60^{\circ}C$, equilibration for 30 min, pH 11, and 2 mL injection volume. Both techniques provided accurate analyses, with detection limits of 0.05-0.1 ng $mL^{-1}$ and 0.05-0.5 ng $mL^{-1}$. HS showed better sensitivity, reproducibility, and analysis times than HS-SPME. Overall levels of chloroform in whole blood were found to be 0.05-5.84 ng $mL^{-1}$; detected levels of benzene were 0.05-2.20 ng $mL^{-1}$.

A Study on Predication model for TVOC Emissions of Finishing material in Apartment House (공동주택 건축내장재의 TVOC 방출량에 관한 예측모델 연구)

  • Kim, Hyung-Soo;Lee, Kyung-Hoi
    • KIEAE Journal
    • /
    • v.2 no.3
    • /
    • pp.55-62
    • /
    • 2002
  • While cognition about an environment pollution becomes important recently, the intense pollution measures about an indoor air environment is required. In the case of building indoor environment, over 80% of modem people is living in building and these days an interest of building interior materials which becomes a reason for indoor environmental pollution in public house, office, is increasing. An experimental measurement method of this study is as follows. (1) American EPA TO-17, ASTMD5116-97, measurement method in VOCs experiment of Japanese closet industrial association (2) 2.4-DNPH cartridge method in HCHO experiment, based on American EPA TO-11 and measurement method of Japanese closet industrial association (3) standard compound is analyzed by using HPLC after solvent extraction process (4) paint and furniture are selected as measurement objects (5) we also made small chamber to grasp an emission characteristic of HCHO and VOCs and to get an environment-amicable forecast model through it, then we developed the model which can forecast emission rate by chamber experiment.

Separation of VOCs from Air through Composite Membranes Prepared by Plasma Polymerization of Hexamethyldisiioxane (Hexamethyldisiioxane의 플라즈마 중합에 의하여 제조된 복합막을 통한 공기중의 휘발성 유기물질의 분리에 관한 연구)

  • 류동현;오세중;손우익;구자경
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.63-65
    • /
    • 1998
  • 1. Introduction : Atmospheric discharge of VOC-contaminated streams in chemical plants and air streams from chemical processes poses a serious environmental problem and entails large financial losses. Such emissions may be reduced by i) adsorption process, ii) absorption process and iii) incineration process. These processes only forbids the air pollutions. Throughout the recent decade, another technique-membrane process has emerged. The separation and recovery of organic vapors by membrane process may have great economic potential. Most of the published research works on the separation of organic vapors from air were performed using silicon rubber membranes. However, it is very difficult to fabricate very thin membranes with less than 1 $u m thickness. Plasma polymerization could be a good technique to generate a thin polymer film. The objective of this work is to find out the optimum condition of plasma polymerization for producing VOC separation membrane. For the objective, composite membranes are prepared through plasma polymerization of hexamethyldisiloxane onto porous substrates under different conditions. The membrane is then subjected to the permeation of permanent gases and VOCs to find the correlations between the physical properties of the penetrant and permeability and selectivity.

  • PDF

The impact of corrosion on marine vapour recovery systems by VOC generated from ships

  • Choi, Yoo Youl;Lee, Seok Hee;Park, Jae-Cheul;Choi, Doo Jin;Yoon, Young Soo
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.1
    • /
    • pp.52-58
    • /
    • 2019
  • Marine emissions of Volatile Organic Compounds (VOCs) have received much attention because the International Maritime Organization (IMO) requires the installation of vapour emission control systems for the loading of crude oils or petroleum products onto ships. It was recently recognised that significant corrosion occurs inside these vapour emission control systems, which can cause severe clogging issues. In this study, we analysed the chemical composition of drain water sampled from currently operating systems to investigate the primary causes of corrosion in vapour recovery systems. Immersion and electrochemical tests were conducted under simulated conditions with various real drain water samples, and the impact of corrosion on the marine vapour recovery system was carefully investigated. Moreover, corrosion tests on alternative materials were conducted to begin identifying appropriate substitutes. Thermodynamic calculations showed the effects of environmental factors on the production of condensed sulphuric acid from VOC gas. A model of sulphuric acid formation and accumulation by the characteristics of VOC from crude oil and flue gas is suggested.

A Study on Analyzing the Validity between the Predicted and Measured Concentrations of VOCs in the Atmosphere Using the CalTOX Model (CalTOX 모델에 의한 휘발성유기화합물의 대기 중 예측 농도와 실측 농도간의 타당성 분석에 관한 연구)

  • Kim, Ok;Lee, Minwoo;Park, Sanghyun;Park, Changyoung;Song, Youngho;Kim, Byeongbin;Choi, Jinha;Lee, Jinheon
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.5
    • /
    • pp.576-587
    • /
    • 2020
  • Objectives: This study calculated local residents exposures to VOCs (Volatile Organic Compounds) released into the atmosphere using the CalTOX model and carried out uncertainty analysis and sensitivity analysis. The model validity was analyzed by comparing the predicted and the actual atmospheric concentrations. Methods: Uncertainty was parsed by conducting a Monte Carlo simulation. Sensitivity was dissected with the regression (coefficients) method. The model validity was analyzed by applying r2 (coefficient of determination), RMSE (root mean square error), and the Nash-Sutcliffe EI (efficiency index) formula. Results: Among the concentrations in the atmosphere in this study, benzene was the highest and the lifetime average daily dose of benzene and the average daily dose of xylene were high. In terms of the sensitivity analysis outcome, the source term to air, exposure time, indoors resting (ETri), exposure time, outdoors at home (ETao), yearly average wind speed (v_w), contaminated area in ㎡ (Area), active breathing rate (BRa), resting breathing rate (BRr), exposure time, and active indoors (ETai) were elicited as input variables having great influence upon this model. In consequence of inspecting the validity of the model, r2 appeared to be a value close to 1 and RMSE appeared to be a value close to 0, but EI indicated unacceptable model efficiency. To supplement this value, the regression formula was derived for benzene with y=0.002+15.48x, ethylbenzene with y ≡ 0.001+57.240x, styrene with y=0.000+42.249x, toluene with y=0.004+91.588x, and xylene with y=0.000+0.007x. Conclusions: In consequence of inspecting the validity of the model, r2 appeared to be a value close to 1 and RMSE appeared to be a value close to 0, but EI indicated unacceptable model efficiency. This will be able to be used as base data for securing the accuracy and reliability of the model.