흉부 X선사진 농도로부터 표면선량을 산출하는 방법 (The Relationship of Overdensity to Overexposure Each Film/screen Systems in Chest Radiography)

  • 김정민;허준;임태랑;석전유치;앵정달야
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제22권1호
    • /
    • pp.13-20
    • /
    • 1999
  • This study is to calculate the exposed radiation dose using Bit method, NDD calculation method and monogram method without dosimeter. In addition, we can calculate the radiation dose from x-ray film density as a film badge. The authors examined the entrance skin dose from $2{\sim}3$ intercostal chest x-ray film density. We also studied the relationship between film density and equivalent dose in the each screen film system under the different radiation quality and the poor geometry condition of grid ratio. As results, we established the deductive method to define the entrance skindose from chest x-ray film density. The error range was found in the range $-13%{\sim}+l7%$ for between deductive entrance skindose and the $2{\sim}3$ intercostal chest x-ray film density to actual detective radiation dose with dosimeter.

  • PDF

피폭선량 산출을 통한 피부입사선량 계산: 머리 및 손목을 중심으로 (Entrance Surface Dose according to Dose Calculation : Head and Wrist)

  • 성호진;한재복;송종남;최남길
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권3호
    • /
    • pp.305-312
    • /
    • 2016
  • 본 연구에서는 진단용 X선 검사에서 환자에게 피폭되는 두부 및 사지를 다양한 선량 계산법을 통해 실측 선량과 비교 실험하였다. 또한 촬영 장비의 형태, 장비 설정조건, X선의 용량, X선관과 환자와의 거리, X선 후방산란차이 등을 고려한 새로운 계산 방법을 제시하여 피폭선량을 산출하였다. 그 결과 피부입사선량이 기존의 선량 계산법보다 실측과의 오차가 줄어들었으며, 환자가 피폭되는 선량을 쉽게 계산할 수 있었고 의료선량 평가가 이루어지게 되어 방사선 관련 종사자들의 의료 선량 관리가 더욱 수월해지는 계기가 될 것으로 사료된다.

선질계수에 의한 피부입사선량 계산법 (Calculation Method of Entrance Skin Dose in X-ray Beam Quality Factor)

  • 김성철;김종일;안성민
    • 한국콘텐츠학회논문지
    • /
    • 제10권2호
    • /
    • pp.258-267
    • /
    • 2010
  • 방사선피폭에 대한 관심이 높아지면서 X선 검사시에 환자에게 조사되는 피폭선량을 정확히 알고 있다는 것은 환자의 불안을 해소하고 또 방사선사나 의사가 피폭선량 경감의식을 향상시키는 데 중요하지만, 임상에서 측정기를 보유하고 있는 시설은 극소수에 불과하다. 본 연구에서는 bit system 및 NDD-M법의 특징을 살려서 우리나라에 사용되고 있는 진단용 X선장치의 출력선량을 직접 측정하여 도표화 하고, X선 출력선량을 아는 경우 또는 모르는 경우 모두에서 적절히 적용할 수 있게 두 가지 방법을 제시하여 실측선량과 비교 실험을 하였다. 그 결과 bit system 및 NDD-M법보다 정확도가 우수한 결과를 나타내어 임상에서 환자가 받는 선량을 더욱 쉽게 알 수 있게 됨으로 방사선관련 종사자들의 의료피폭에 대한 관심이 더욱 높아지고 의료선량감소에 한층 더 노력하는 계기가 될 것으로 사료된다.

유방암환자의 세기조절방사선치료에서 피부선량 평가 (Evaluation of Skin Dose of Intensity Modulated Radiation Therapy in Breast Cancer Patients)

  • 김성규;김명세;윤상모
    • 한국의학물리학회지:의학물리
    • /
    • 제18권3호
    • /
    • pp.167-171
    • /
    • 2007
  • 유방암 환자의 유방보존절제술 후 방사선치료를 시행하는 경우에서 비껴방향치료방법과 세기조절방사선치료를 시행한 두 경우에 피부에 조사되는 표피 흡수선량을 비교, 분석하여 유방암 환자에서 세기조절방사선치료시 피부선량의 특성을 살펴보았다. 비껴방향치료방법과 세기조절방사선치료에 대한 두 가지 방법으로 치료계획을 시행하여 유방 피부에 조사되는 계산선량과 TLD로 측정한 측정선량을 비교하였다. 선량측정은 유두가 있는 지점을 지나도록 몸의 중심에서 가장자리 방향으로 1 cm 간격으로 피부 흡수선량을 측정하였다. 비껴방향방사선치료에서 PTV에 180 cGy 방사선량을 계획할 때, 유방 표피에서 계산선량은 103.6 cGy에서 155.2 cGy 사이를 나타내었고, 측정선량은 107.5 cGy에서 156.2 cGy 사이를 나타내었으며, 중심부위의 피부선량이 가장자리 피부선량보다 최대 1.45배 많이 조사되었다. 세기조절방사선치료에서는 PTV에 180 cGy 방사선량을 계획할 때, 유방 표피에서 계산선량은 9.8 cGy에서 80.2 cGy사이를 나타내었고, 측정선량은 8.9 cGy에서 77.2 cGy사이를 나타내었으며, 중심부위의 피부선량이 가장자리 피부선량보다 최대 0.23배 적게 조사되었다. 비껴방향방사선치료에서 보다 세기조절방사선치료에서 피부에 조사되는 방사선량이 평균적으로 3.5배 적어서 방사선 치료에 의한 피부 위해를 줄일 수 있다.

  • PDF

디지털 흉부 촬영에서 구리필터사용에 따른 환자 표면선량 감소효과에 관한 연구 (The Study on the Reduction of Patient Surface Dose Through the use of Copper Filter in a Digital Chest Radiography)

  • 신수인;김종일;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권3호
    • /
    • pp.223-228
    • /
    • 2008
  • 의학적으로 방사선을 사용 시 가장 중요한 점은 환자의 병을 진단 가능하되 피폭선량을 최소화시켜야 한다는 점이다. 진단용 X-선 중 장파장부분은 대부분 흡수에 관여하게 되어 환자의 피폭선량을 증가시키므로 불필요하다. 이러한 장파장영역을 제거하기 위한 방법으로 가장 효과적인 방법은 여과 판의 사용이다. 이에 부가여과가 없는 경우와 0.3mmCu filter 사용 시의 화질과 피부입사선량에 대해 실험을 해 보았다. ROC 신호용 지름 4mm, 두께 3mm의 아크릴 디스크를 chest phantom에 랜덤하게 위치시키면서 non filter 및 Cu filter시 각 각 20매씩 총 40매의 신호+잡음영상을 촬영하고, 또한 신호가 없는 영상(잡음만의 영상)을 각 각 20매씩 40매 촬영하여 총 80매의 영상을 준비한 후 5명의 방사선종사자가 판독 후 P(S/s), P(S/n) 구하여, ROC곡선을 그리고, 감도와 특이도 및 곡선하면적을 구해 평가하였다. 또한 AAPM(American Association of Physicists in Medicine by the American Institute of Physics)권고에 따른 ANSI chest phantom과 Contrast-detail phantom을 이용하여 non filter 또는 Cu filter사용 시 시각적으로 관찰 가능한 병소의 갯수를 파악하였으며, 또한 두 경우에서 피부입사선량을 측정하였다. 그 결과 Cu filter사용 시에 ROC곡선이 좌상방향에 위치하고, 감도, 곡선하면적 및 CD phantom 병소의 갯수에서 모두 좋은 결과를 나타내었다. 또한 피부입사선량은 감소가 되어 여러 측면에서 부가필터의 사용을 검토해 볼 필요가 있으리라 사료된다.

  • PDF

입사 표면 선량 계산에 따른 진단용 X-선 촬영시 피폭선량 비교 연구 (Comparative Study of Radiation Exposure using Entrance Skin Dose Calculation Technique in Diagnostic X-Ray Radiography)

  • 한재복;최남길;성호진
    • 한국콘텐츠학회논문지
    • /
    • 제11권12호
    • /
    • pp.357-363
    • /
    • 2011
  • 본 연구는 유리 선량계를 이용한 진단용 X선 장치 선량 및 선질의 입사표면선량 값과 선질 계수에 의한 계산 측정법을 바탕으로 비교 평가하여 의료 피폭 선량에 대해 연구하였다. 실제 측정에 의한 ESDs 값이 Mori에 의한 NDD-M 법에서 가장 큰 차이를 보였으며, Edmonds에 의한 계산법이 가장 적은 차이를 보였다. 또한 정류 방식에 따른 실 측정과 선량 계산법 차이는 삼상 정류 방식, 단상 정류 방식, 인버터 방식으로 차이가 적게 나타났다. 본 연구 결과는 향후 진단용 X-선 촬영 장치의 사용에 있어 환자의 피폭 선량을 예측하고 검사 조건을 조절하여 의료 피폭 선량을 절감할 수 있을 것이다.

복부일반촬영시 선원과 검출기간의 거리변화에 따른 영상 화질 및 피폭선량에 관한 연구 (A Study on Patients Dose and Image Quality according to Source to Image receptor Distance in Abdomen Radiography: comparison of ESD measured and DRLs in other countries)

  • 장지성;최원근;정재연;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.39-46
    • /
    • 2012
  • Purpose : The purpose of this study was to reduce Entrance Surface Dose and maintain image quality by changing Source to Image receptor Distance. And we'd like to compare ESD on this study to DRLs in other contries. Materials and Methods : We used indirect DR system(Definium 8000, General Electric, USA)and phantom(ART-200X, Flukebiomedical, USA),glass dosimeters(GD-352M, Asahi Techno Glass, Japan)for this study. The imagies were obtained throuh 80kVp fixed, and different tube currents using AEC mode in $16{\times}16$(inch) field size and changing Source to Image receptor Distance from 100 cm to 130 cm per 10 cm unit. The phantom with attaching 5 glass dosimeters on abdomonal skin was set at supine and erect position as a anterioposterial projection on detector For measuring Entrance Surface Dose. Image analysis was conducted by histograms of Image J(1.46r) which was given from National Institutes of Health(NIH). Results : Due to inverse square law of distance, the tube currents were increasing 42.6 % in supine position and 32.6 % in erect position according to the change of Source to Image receptor Distance. While Entrance Surface Doses were rapidly decreasing 14.2 % in supine position and 29.4 % in erect position according to the change of Source to Image receptor Distance. As the results of histogram using Image J, pixel mean values from 100 cm to 110 cm, 120 cm and 130 cm were decreasing each 1.4%, 2.5%, 2.7%, 4.5%, 2.2 %, 5.8 % in supine, erect position. While standard deviations from 100 cm to 110 cm, 120 cm and 130 cm were increasing each 1.4 %, 2.5 %, 2.5 %, 4.0 %, 2.0 %, 4.9 % Consequently, there are no significant differences in abdomen images taken. Conclusion: As the results described above, we strongly recommend using long Sourceto Image receptor Distance than 100cm that we have been using. So, we should deliver less Entrance Surface Dose to the patients while maintaining image quality in abdomen radiography.

  • PDF

복부 단순 X-선 촬영조건과 환자 피폭에 관한 조사 연구 (A Survey on Patient Dose and Exposure Conditions in Simple Radiography of the Abdomen)

  • 김성수;이선숙;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제19권2호
    • /
    • pp.59-65
    • /
    • 1996
  • We studied exposure techniques and exposure dose for simple abdomen A-P projection for 41 medical facilities that are located in Seoul area. 1. The range of tube voltage used was 60 to 84 kVp, the average tube voltage used was 74 kVp 2. Only 17% of added filter was used. 3. Tube current mostly used was 200 mA, some of them used 400 mA. 4. The grid ratio mostly was used 10 : 1, 54 % of the rare earth screen was used in most facilities. 5. The average skin entrance dose was 4.15 mSv and the dose range was 1.05 mSv to 11.0 mSv.

  • PDF

Glass Dosimeter를 이용한 환자피폭선량에 관한 분석 (Analysis of Patient Exposure dose with Glass Dosimeter)

  • 김재인;최원근;장성원;오창섭;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제11권1호
    • /
    • pp.15-20
    • /
    • 2009
  • Far reducing medical radiation exposure and managing patient doses, Entrance surface doses(ESDs) were measured at Diagnostic Radiology Department in ASAN medical center, also we determined and compared with the Diagnostic Reference Level(DRL) of some other countries. ESDs were measured far the most common types of X-ray procedures, such as chest PA, lumbar spine AP, lumbar spine lateral, Pelvis AP, Skull PA. ESDs were measured by Glass dosimeter and Unfors Xi meter. Those were applied collimation center of phantom's entrance skin surface. The results of ESDs were compared Glass dosimeter with Unfors Xi meter. Those were measured within 5% statistical difference. It seemed well agreement at two devices. In most cases ESDs measured far the different types of X ray procedures were found to be lower than the DRL of IAEA, but ESDs on chest PA, lumbar spine AP, lumbar spine lateral, Pelvis AP, Skull PA were proximity ar excesses at DRL of advanced country. Through this study, we need an investigation and improvement at present diagnostic radiology exam system. Also, radiologists make an effort to reduce patient dose and having a technical skill.

  • PDF

영상유도 방사선 치료(IGRT)에 따른 정상 조직의 추가 피폭에 대한 연구 (A Study on the Additional Absorbed Dose of Normal Tissues by Image Guided Radiation Therapy(IGRT))

  • 김가중;류준민;최준구;홍동희
    • 한국콘텐츠학회논문지
    • /
    • 제16권1호
    • /
    • pp.75-81
    • /
    • 2016
  • 최근 방사선 치료 분야에서는 다양한 영상유도 방사선 치료(IGRT) 장치들을 이용한 환자 셋업으로 고도의 정밀성이 보장된 치료가 가능해 졌다. 그러나 환자의 정상 조직에 받는 추가 선량 또한 더불어 증가되고 있다. 이에 본 연구에서는 영상유도 방사선 치료 장치 중 OBI, CBCT, ExacTrac를 이용한 환자 셋업에 주변 정상 조직에 받는 피폭선량을 측정하였다. 결과 팬텀 중심부의 선량이 CBCT의 경우 두부 12.57 mGy, 흉부 20.82 mGy, 복부 82.93 mGy, 골반부위 52.70 mGy로 측정되었으며 OBI는 0.76 ~ 8.58 mGy, ExacTrac의 경우 0.14 ~ 0.63 mGy로 CBCT의 피폭선량이 다른 장비에 비해 월등히 높게 나타나는 것을 알 수 있었다. 표면 선량의 경우에서도 CBCT가 다른 장비에 비해 높게 나타났으나 입사 피부표면 선량(Enterance skin dose)의 경우 OBI도 CBCT의 피폭선량과 거의 비슷한 흡수선량이 측정 되었다.