• 제목/요약/키워드: energy saving investment

검색결과 57건 처리시간 0.025초

구조단열패널 적용 저에너지주택의 총에너지사용량 평가 (Evaluation on Total Energy Consumption of Low-Energy House with Structural Insulated Panels)

  • 이현주;나환선;조혜진;최성모
    • 복합신소재구조학회 논문집
    • /
    • 제4권2호
    • /
    • pp.15-24
    • /
    • 2013
  • This project is mainly related to evaluation of total energy consumption of low energy house, the exterior envelope of which was wholly composed of structural insulated panels(SIP). The U-value of applied SIP was in the range of 0.189 to $0.269W/m^2{\cdot}K$ and the U-value of pair glass from 0.78 to $1.298W/m^2{\cdot}K$ was applied for window dependent to its function respectively. For comparison of total energy performance, the energy simulation for pilot house was performed to compare with the control house having insulation criteria of Korean building regulation in 2009. Based on simulation of dynamic energy performance, the pilot house saved 48.3% of annual energy consumption while the control house in 2009 consumed as 85.7GJ/y. In case of heating, the result showed that the energy saving ratio amounted to 76.7%. For $CO_2$ emission, the pilot house diminished approximately 35.4% from $6,208.4kgCO_2$ to $4,009.2kgCO_2$. In payback period to early investment, it was analyzed the pilot house took 7.8 years, when the low energy house built by other insulation method with same thermal perfusion took 11.5 years. From this result, it is considered that the SIP is more effective, economic to Green Home application.

탄소배출권 투자와 위험관리방안 연구 - 일차배출권(Primary CER) 투자 시 등록위험 및 가격변동 위험을 중심으로 - (Study on the Risk Management of the CERs Investment - Regarding Registration Risks and Price Change Risk in Investing Primary CERs -)

  • 이창석;김윤성;전의찬
    • 한국기후변화학회지
    • /
    • 제2권2호
    • /
    • pp.115-131
    • /
    • 2011
  • 온실가스의 감축 규제가 세계 경제에 미치는 영향은 매우 클 것으로 예상되며, 산업 전반에 걸쳐 적절한 대응방안 도입이 필요한 시점이다. 이에 본 연구는 온실가스 감축 규제에 대응하기 위해서 취해질 수 있는 온실가스 저감 기술, 설비 개발, 에너지 절약 및 효율화 활동, 탄소배출권 구입을 통한 탄소 상쇄 등 여러 경제적 행위 중에서 탄소배출권 투자에 초점을 맞추어 연구하였다. 특히, 탄소배출권 투자 시 고려해야 할 위험 요인 중에서 UN 등록 거절 위험과 탄소배출권 가격변동성 위험을 최소화하기 위한 위험관리 모형을 설계하고 검증하였다. 이를 통해 탄소 상쇄가 필요한 다양한 분야의 이해관계자가 최적화된 탄소배출권과 관련한 전략을 수립할 수 있도록 제안하는 것을 목표로 한다. 기후변화에 따른 새로운 메커니즘에 국내 금융회사들이 신속히 대응할 수 있는 방법을 모색하고자 한 본 연구는 현재 청정개발체제(CDM)에서 발급되는 탄소배출권(CER)에 국한되지 않고 공동이행체제(JI) 프로젝트에서 발급되는 탄소배출권(ERU), 배출권거래제(ET)에서 인정되는 탄소배출권(AAU) 뿐만 아니라 향후 새롭게 인정될 탄소배출권에도 유사하게 적용될 수 있을 것이다.

IOT 기술을 활용한 에너지 절약 하우스 시스템 연구 (A Study on the Energy Saving House System Using IOT Technology)

  • 허명회;신승중
    • 한국인터넷방송통신학회논문지
    • /
    • 제20권6호
    • /
    • pp.109-113
    • /
    • 2020
  • 전 세계적으로 저탄소 녹색성장을 배경으로 인간과 자연이 공존하는 지속가능한 사회에 많은 이목이 쏠리고 있다. 탄소 배출은 에너지소비량에 따라 증가하게 되는데 전 세계적으로 건축물에 의한 에너지소비량이 무려 40%에 달한다. 우리나라에서는 2025년 신규 건축물에 한하여 제로 에너지 하우스를 의무화하는 계획을 하고 있으나 제로 에너지 하우스에 관한 기술을 민간 기술 투자에만 의지하고 있다. 정확한 로드맵이 확정된 것이 없어 현재 기술로는 일반건축물 보다 1.5배 이상의 비용이 들고, 민간 기업들은 실험용 주택 말고는 실제 거주하는 제로 에너지 하우스단지가 많이 없다는 것이 현실이다. 본 연구는 제로 에너지 하우스에 에너지를 효율적으로 관찰 및 제어하는 IOT 시스템을 도입하여 쾌적한 환경에 대한 모니터링이 웹에서 확인 및 거주자의 적정온도 유지시스템을 도입하여 제로 에너지 하우스의 새로운 모델을 연구하고자 한다.

Optimal synthesis for retrofitting heat exchanger network

  • Lee, In-Beum;Jung, Jae-Hak;Chang, Kun-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.1259-1264
    • /
    • 1990
  • During the past two decades, a lot of researches have been done on the synthesis of grassroot heat exchanger networks(HEN). However, few have been dedicated to retrofit of existing heat exchanger networks, which usually use more amount of utilities (i.e. steam and/or cooling water) than the minimum requirements. This excess gives motivation of trades-off between energy saving and rearranging investment. In this paper, an algorithmic-evolutionary synthesis procedure for retrofitting heat exchanger networks is proposed. It consists of two stages. First, after the amount of maximum energy recovery(MER) is computed, a grass-root network featuring minimum number of units(MNU) is synthesized. In this stage, a systematic procedure of synthesizing MNU networks is presented. It is based upon the concept of pinch, from which networks are synthesized in a logical way by the heuristics verified by the pinch technology. In the second stage, since an initial feasible network is synthesized based on the pre-analysis result of MER and must-matches, an assignment problem between new and existing units is solved to minimize total required additional areas. After the existing units are assigned, the network can be improved by switching some units. For this purpose, an improvement problem is formulated and solved to utilize the areas of existing units as much as possible. An example is used to demonstrate the effectiveness of the proposed method.

  • PDF

설비 투자비용의 관점에서 쿨루프와 옥상녹화의 비교 평가: 경북대학교 캠퍼스 사례를 중심으로 (Comparative Evaluation between Cool Roof and Green Roof in terms of Installation Cost: a Case Study of KNU Campus)

  • 김준우;엄정섭
    • 환경영향평가
    • /
    • 제21권6호
    • /
    • pp.927-939
    • /
    • 2012
  • Cool roofs are currently being emerged as one of important mechanism to save energy in relation to the building. Although green roof has already gained nation-wide recognition as a typical method of energy saving in the roof, this approach did not provide a realistic evidence that is economically feasible in terms of installation cost. This research is primarily intended to compare installation cost between the two techniques. This research proposes a comparative evaluation framework in a more objective and quantitative way for an installation cost between the two techniques. Kyungpook National University (KNU) was selected as a survey objective and an exhaustive and realistic comparison of installation cost between the two techniques was conducted, based on Life Cycle Cost analysis (initial investment cost, maintenance cost, dismantling and waste disposal expense). It was possible to identify that installation cost of cool roofs is 4.7 times cheaper than that of green roof. Also present value based on probabilistic approach was identified as 0.25 (4.95) higher than the installation cost on the assumption of constant price and interest. It is expected that much more installation cost for the large scale green roof will be required since small-size green roof selected as a survey objective in this study could be operated under less initial installation and maintenance condition.

통합 시뮬레이션을 통한 리모델링용 이중창 시스템 기류 패턴 분석 (Airflow pattern of Double window system for Remodeling by using Integrated Simulation.)

  • 김은희;남현진;육인수;김정윤;김재민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1036-1041
    • /
    • 2008
  • Double facade systems are often paid attention of as an effective energy saving measure for curtain wall buildings. However, it is not easy to install the system in existing buildings and requires substantial investment. An innovative double window system is proposed in this study which can be installed with exiting window systems in a cost effective way. the proposed system is connected to existing return ducts to make airflow between the existing window and the newly installed window. To ensure the best performance of the proposed system, simulation-based analysis was implemented in which airflow characteristics of inside double window were examined according to air pressures of return duct and window material by using computer simulation ESP-r. the overview of the proposed system and the results of the simulation-based analysis are presented in this paper.

  • PDF

시설원예농가의 재생에너지 적용가능성평가 -지열.태양광의 경제성 분석을 중심으로- (Evaluation of Applicability of Renewable Energy in Controlled Horticulture Farms -Centering on Economic Analysis of Geothermal.Solar Powered-)

  • 김태호;윤성이
    • 한국유기농업학회지
    • /
    • 제20권3호
    • /
    • pp.267-282
    • /
    • 2012
  • In this study, RPS system, one of the renewable energy support systems, is utilized for economic analysis of solar generation equipment and the fuel cost savings plan for controlled horticulture farms with high fuel-cost dependency and facility applicability were evaluated. On the exterior of the upper layer of glass greenhouse (9917$m^2$) of controlled horticulture farms using bunker C oil, half of the area (4958$m^2$) was utilized for theoretical installation and operation of 450kW-level solar power generator, and as the result, first, the effect of investment cost only of solar generation system was found to be quite excellent, but it was analyzed that there were limits to saving the fuel costs of the controlled horticulture farms. Second, when geothermal system was first introduced in the farm and solar system was additionally introduced, it was analyzed that the effect of introducing solar system was excellent. In order to apply such effects to the sites of farming, partial supplementation of RPS system which is being uniformly applied regardless of the purpose of renewable energy is necessary. When the subject of use directly install facilities where it is directly connected to national added-value such as food security created by the farming industry, it is necessary to introduce appropriate system that corresponds to such. Moreover, it was studied that the quick development of demonstrative complex that can practically evaluate the applicability of renewable energy in farming industry and interest and preparation of related institutions in financial support structure for its site application would lead to success.

BES를 이용한 온실용 보온커튼의 관류열전달계수 산정 (Evaluation of Overall Heat Transfer Coefficient of Different Greenhouse Thermal Screens Using Building Energy Simulation)

  • 라쉬드아드난;이종원;이현우
    • 생물환경조절학회지
    • /
    • 제27권4호
    • /
    • pp.294-301
    • /
    • 2018
  • 겨울철에 열손실을 줄이기 위해 많은 온실에서 보온커튼을 사용하고 있다. 그러나 적절한 보온커튼을 선택할 때 판단 자료로 활용할 수 있는 명확한 기준이 없는 실정이며 이를 위해서는 보온재의 보온 특성에 대한 정량적인 값이 필요하다. 본 연구에서는 BES를 사용하여 보온커튼의 관류열전달계수를 산정하는 시뮬레이션 모델을 개발하였다. 일중 및 이중 PE필름 피복에 대한 관류열전달계수의 실험값을 사용하여 시뮬레이션 결과를 검증하였다. 검증된 모델을 사용하여 문헌에서 제시된 각종 열적 특성을 가진 보온커튼에 대한 관류열전달계수를 산정하고 비교분석하였다. 개발된 시뮬레이션 모델은 다양한 보온커튼의 관류열전달계수를 산정하는 데 활용될 수 있을 것이며, 제시된 관류열전달계수는 보온커튼의 성능을 정량적으로 비교하는데 유용하게 활용될 수 있을 것으로 판단된다.

기후변화협약 시행에 따른 대응 방안 및 발전분야 영향 분석 (Analysis of the abroad and domestic research trends on climate change and its economical effect on the power plant)

  • 우광제;황재동;정석용;장길홍
    • 청정기술
    • /
    • 제7권1호
    • /
    • pp.43-49
    • /
    • 2001
  • $CO_2$ 의무규제에 대비해 국내외의 대응방안 및 기술개발 동향과 국내 산업계 대처방안, 향후 발전분야에 미칠 영향 등을 분석하였다. 의무규제에 대비하여 가장 많은 준비가 된 유럽은 에너지 효율 개선 및 대체에너지 개발에 많은 투자를 하고 있으며, 일본은 에너지 절약 및 해외사업을 통해 감축의무를 준수하도록 하는 동시에, 장기 기술개발 계획에 따라 여러 분야에서 R&D 투자가 활발히 이루어 지고 있다. 또한, 미국은 에너지 절약 프로그램 및 배출권 거래제를 이용하여 감축의무에 대비하고 있으며 최근에 DOE(Department of energy)등을 중심으로 경제성 있는 신기술 분야에 집중 연구하는 경향을 보여주고 있다. 우리나라도 향후 의무부담을 받을 경우를 대비하여 그동안 정부 및 출연연구소 중심으로 연구가 수행되어 왔다. 한편, 감축의무 적용시 가장 먼저 이행이 예상되는 발전분야에 대해 선진국중 완화된 기준을 가지는 포르투갈 감축기준을 적용하였을 경우, 제5차 장기전력 수급계획에 따른 청정연료 등의 전환 등의 자발적 감축노력에도 불구하고, 2015년 이후 가동중인 발전소중 50여기를 가동 중지해야 하는 사태가 발생할 수 있음을 발전분야 감축의무량 분석결과를 통해 도출하였다.

  • PDF

납사열분해 가스분리공정에서의 Petlyuk Column 설계 (Design of Naphtha Cracker Gas Splitter Process in Petlyuk Column)

  • 이주영
    • 한국가스학회지
    • /
    • 제24권1호
    • /
    • pp.17-22
    • /
    • 2020
  • Naphtha Cracker Gas Splitter Unit 공정은 증류공정에서 얻어지는 경질납사(Light Naphtha)를 Furnace에서 열분해하여 나오는 유분을 각각 끓는점 차이에 따라 메탄, 에틸렌, 프로필렌 반제품등으로 순차적으로 분리한다. 이런 전통적인 분리방법은 2성분을 분리하는 증류탑을 연속으로 설치하여 생산한다. 이러한 분리방법은 Reboiler에서 발생하는 에너지가 증류탑 내부의 성분들을 분리하는 데 사용된 후 증류탑 상부 Condenser에서 응축열로 버려지기 때문에 에너지 낭비가 큰 것으로 알려져 있다. 본 연구에서는 납사 열분해공정내의 가스분리공정의 2개의 증류탑을 Petlyuk Column으로 설계하였다. 증류탑내 조성분포가 평형관계만으로 계산되는 이상단수 효율하에서 stage to stage 계산방법으로 구조적 설계를 하였고 일반 증류탑과 비교한 결과 제시된 Petlyuk Column의 설계방법이 기존의 설계 방법인 3-Column 모델법보다 설계 시간이 단축될 뿐만 아니라 증류탑내의 Liquid의 조성분포를 평형증류 조성곡선과 유사하도록 설계함으로써 에너지 효율측면에서도 효율적임을 증명하였다. 또한 같은 tray 단수하에서 Petlyuk Column은 일반 증류탑 대비 12.1% 에너지가 절약되어 국내 총생산량 기준할 때 하루 4,400만원 비용 절감을 가져오고 추가로 Condenser 및 Reboiler 사용량 감소에 따른 초기 투자비도 절감됨을 알 수 있었다. 12.1% 에너지가 절약될 뿐만 아니라 Condenser 및 Reboiler 사용량 감소에 따른 초기 투자비도 절감됨을 알 수 있었다.