• 제목/요약/키워드: energy module

검색결과 1,520건 처리시간 0.058초

환경변화 요인에 따른 결정질 실리콘 태양전지모듈의 최대출력 특성 분석 (The Analysis on Maximum Output Power Characteristics of Crystalline Silicon Photovoltaic Module by Change of Environmental Effects)

  • 강기환;김경수;박지홍;유권종;안형근;한득영
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.23-28
    • /
    • 2007
  • In this study, we analyzed the maximum output power characteristics of crystalline silicon photovoltaic module by change of environmental effects. The electrical, optical and thermal property of PV modules were investigated during outdoor test period about 70 days. There was a fluctuation in maximum output power by change in transmittance caused by environment effects like rain, snow and dust. The effects of external environmental change were analyzed using climate data. Also local thermal temperature variation and transmittance imbalance on surface of PV module which might lead degradation of constituent material were detected using infrared camera. The further analysis is describe in the following paper.

구성 재료와 방사조도 특성에 따른 태양전지모듈의 최대출력 분석 (Analysis of Maximum Power Generation of Photovoltaic Module Depending on Constituent Materials and Incident Light Characteristics)

  • 강기환;김경수;박지홍;유권종;안형근;한득영
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.1-6
    • /
    • 2007
  • In this study, we analyze the maximum power generation of photovoltaic(PV) module depending on constituent materials and incidence angle dependence of light. To verify characteristics of constituent materials, we made photovoltaic modules with 4 kinds of solar cells and textured glass according to fabrication method. To find the degree of the maximum power generation dependence on intensity of light, Solar Simulator is applied by changing angle of module and light intensity. Through this experiment, to obtain maximum power generation from limited PV modules, it is needed to fully understand constituent materials, fabrication method and dependence of incident light characteristics.

A Safety Analysis of a Steam Generator Module Pipe Break for the SMART-P

  • Kim Hee Kyung;Chung Young-Jong;Yang Soo-Hyung;Kim Hee-Cheol;Zee Sung-Quun
    • International Journal of Safety
    • /
    • 제3권1호
    • /
    • pp.53-58
    • /
    • 2004
  • SMART-P is a promising advanced small and medium category nuclear power reactor. It is an integral type reactor with a sensible mixture of new innovative design features and proven technologies aimed at achieving a highly enhanced safety and improved economics. The enhancement of the safety and reliability is realized by incorporating inherent safety improving features and reliable passive safety systems. The improvement in the economics is achieved through a system simplification, and component modularization. Preliminary safety analyses on selected limiting accidents confirm that the inherent safety improving design characteristics and the safety system of SMART-P ensure the reactor's safety. SMART-P is an advanced integral pressurized water reactor. The purpose of this study is for the safety analysis of the steam generator module pipe break for the SMART-P. The integrity of the fuel rod is the major criteria of this analysis. As a result of this analysis, the safety of the RCS and the secondary system is guaranteed against the module pipe break of a steam generator of the SMART-P.

액체식 PV/Thermal 복합모듈의 성능실험연구 (An Experimental Study of a Water Type PV/Thermal Combined Collector Unit)

  • 이현주;김진희;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.105-111
    • /
    • 2007
  • Hybrid PV/Thermal systems consisting of photovoltaic module and thermal collector can produce the electricity and thermal energy. The solar radiation increases the temperature of PV modules, resulting in the decrease of their electrical efficiency. Accordingly hot air can be extracted from the space between the PV panel and roof, so the efficiency of the PV module increases. The extracted thermal energy can be used in several ways, increasing the total energy output of the system. This study describes a basic type of PV/T collector using water. In order to analyze the performance of the collector, the experiment was conducted. The result showed that the thermal efficiency was 17% average and the electrical efficiency of the PV module was about $10.2%{\sim}11.5%$, both depending on solar radiation, inlet water temperature and ambient temperature.

도시·주택 적용 에너지수확 블록구조의 진동 특성 및 발전성능 평가 (Evaluation on the Performance of Power Generation and Vibration Characteristics of Energy Harvesting Block Structures for Urban & Housing Application)

  • 노명현;이상열
    • 한국산학기술학회논문지
    • /
    • 제13권8호
    • /
    • pp.3735-3740
    • /
    • 2012
  • 본 연구는 다양한 에너지 하비스팅 기술들 중 압전 기술과 전자기 유도 방식을 조합한 에너지 블록 구조를 개발하고 발전성능 평가를 수행한다. 본 연구의 목적은 개발된 에너지 하비스팅 블록의 주택 도시 분야 적용성을 평가하기 위한 것이다. 본 연구는 동적 특성을 분석하기 위하여 유한요소 해석을 실시하고, 실험실 규모의 다층 에너지 하비스터의 현 발전수준을 평가하여 제시하였다. 그 다음으로 증폭기술이 적용된 프로토타입의 특징을 설명하고 개발된 프로토 타입 모듈의 발전성능을 다각적으로 평가하여 제시하였다.

건물일체형 투명 모듈의 온도 변화에 따른 발전 특성 (Generation characteristics of transparent BIPV module according to temperature change)

  • 박경은;강기환;김현일;유권종;장대호;이문희;김준태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.210-211
    • /
    • 2007
  • Amid booming PV(photovoltaic) industry, BIPV(Building Integrated PV) is one of the best fascinating PV application technologies. To apply PV in building, variable factors should be reflected such as installation position, shading, temperature effect and so on. Especially a temperature should be considered, for it affects both electrical efficiency of PV module and heating and cooling load in building. Transparent PV modules were designed as finished material for spandrels are presented in this paper. The temperature variation of the modules with and without air gap and insulation were compared and analyzed. The results showed that the module with air gap and insulation has a much larger temperature variation than another transparent module. The temperature of the module reached by 55degree C under vertical irradiance of lower 500$W/m^2$. And the temperature difference between these modules was about 15degree C. To analyze the output performance of module according to temperature variation, separate module was manufactured and measured by sun-simulator. The results showed that 1 degree temperature rise reduced about 0.45% of output power.

  • PDF

공기식 태양광/열 시스템 공기채널 내 여러 저항체 설치에 따른 전열성능에 관한 CFD 해석 (CFD Analysis on the Heat Transfer Performance with Various Obstacles in Air Channel of Air-Type PV/Thermal Module)

  • 최휘웅;파쿠르 로커만;김영복;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제38권2호
    • /
    • pp.33-43
    • /
    • 2018
  • PV/Thermal module is the combined system, which consist of a photovoltaic module and solar thermal collector that can obtain electrical power and thermal energy simultaneously. Thus the power generation can be increase by decreasing the temperature of photovoltaic module and thermal energy retrieved from module also can be used for heating system. In this study, Heat transfer performance of air type PV/Thermal module was confirmed with various bottom obstacles that can be installed easily to real photovoltaic module by CFD (computational fluid dynamics) analysis. Eight type obstacles were investigated according to the shape and arrangement. As a result, nusselt number represent heat transfer performance was increased about 86% compare with the basic type PV/Tthermal module that has no obstacle and triangle type obstacle had higher value than other types. But pressure drop was also increased with increment of heat transfer enhancement. Thus the performance factor considering both heat transfer and pressure drop was confirmed and V-fin type obstacle arranged in a row for Reynolds number below 9,600 and protrusion type obstacle arranged in zigzag for Reynolds number above 14,400 were shown higher performance factor than other types. From these results, V-fin type obstacle arranged in row and protrusion type obstacle arranged in zigzag were considered as a proper type for applying to real PV/thermal module according to operating condition. But the heat transfer performance can be changed by the geometric conditions of obstacle such as height, width, length and arrangement. Thus, it could also confirmed that the optimal condition and arrangement of this obstacle need to be found in further study.

IEC61215을 통한 PV모듈 내구성 평가 및 분석 (Durability Determination and Analysis during IEC61215 PV Module Test)

  • 김경수;강기환;유권종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1061_1061
    • /
    • 2009
  • Running low of fossil fuel energy forces the industry to find a new way to overcome this energy crisis. One of the solutions is using the unlimited and everlasting energy sources like wind, sun, water, and so on. Especially, sun energy becomes the hottest issue in recent years because of its merit in installation, operation and abundant material source of silicon. In 2008, about 5.5GW photovoltaic (PV) system has been installed all around world. Many professional renewable energy organizations expect that the total PV system installation will be 30GW. To sustain the long-term stability of the PV system, several institutes perform the test based on IEC standards like IEC 61215 for silicon crystalline PV module and IEC 61646 for thin film PV module. Also in South Korea, Korea Institute of Energy Research (KIER) performs the certificate test according to IEC 61215 standards. In this paper, we want to summarize and inform the 3 years‘ test results of domestic and foreign PV modules. The specific and technical explanation will be shown in the following paper in detail.

  • PDF

Characteristics of Photovoltaic I-V According to the Module Temperature

  • Lee, Ying;Choi, Yong-Sung;Zhang, You-Sai;Hwang, Jong-Sun;Lee, Kyung-Sup
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2101.1_2102.1
    • /
    • 2009
  • Solar energy is an extreme intermittent and inconstant energy source. This paper presents the analysis of photovoltaic I-V characteristics according to the module temperature. It shows that the result of the relationship between DC current and the module temperature of solar cell will be effects by the increasing irradiation.

  • PDF

BiTe계 thermoelectric module을 이용한 발전기 제작과 특성 (Manufacturing of thermoelectric generator using BiTe module)

  • 우병철;김봉서;이희웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 C
    • /
    • pp.1446-1448
    • /
    • 1997
  • TEC(Thermoelectric conversion) is direct conversion method between thermal energy and electric energy. We studied on the mechanical, electrical and thermal properties of thermoelectric module and made experimental thermoelectric generator with BiTe material.

  • PDF