• Title/Summary/Keyword: energy distribution

Search Result 5,743, Processing Time 0.039 seconds

A Study on Optics and Spectral Energy Distribution Characteristics of LEDs lamp (LED램프의 광학 및 분광분포 특성 연구)

  • Hwang, Myung-Keun;Huh, Chang-Su
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.1
    • /
    • pp.68-75
    • /
    • 2003
  • 본 논문에서는 파랑, 녹색, 호박색 빨강색, 백색 등 고휘도 5mm LED(light emitting diode)의 기본적인 분광분포(SED: spectral energy distribution) 특성을 분석하였으며, LED램프의 중요한 광학 특성인 광속, 효율 피크 파장$({\lambda}p)$, 가중치 평균 파장, 반치폭(FWHM, $\Delta\lambda$), 색도좌표, 주 파장, 자극순도(Pe)와 휘도순도(Pc) 등을 측정 및 실험하였다. 제시된 LED램프의 특성 데이터는 앞으로 LED램프를 사용한 새로운 조명등기구를 개발하는데 많은 도움을 줄 것이며, 이러한 측정 데이터들은 조명용 광원으로서 LED램프의 사용 대체 가능성을 나타낸다.

Electron energy distribution functions in an inductively coupled a-based plasma (Cl-based 유도결합 플라즈마의 전자에너지 분포함수)

  • Kim, Gwan-Ha;Kim, Chang-Il;Kim, Dong-Pyo;Kang, Young-Rog
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.91-91
    • /
    • 2005
  • Electron energy distribution functions and plasma parameters such as electron temperature ($T_e$) and electron density ($n_e$) in low-pressure Cl-based plasmas have been measured. As the $Cl_2/A4$ gas mixing ratio, the $BCl_3$ gas addition and the process pressure increases, the electron energy probability and the electron temperature decreases. In case of source power increases, electron energy probability increases, whereas the electron temperature was not related.

  • PDF

Xenon Initialization for Reactor Core Transient Simulation

  • Kim, Yong-Rae;Song, Jae-Seung;Lee, Chang-Kue;Lee, Chung-Chan;Zee, Sung-Quun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.88-93
    • /
    • 1996
  • The initial condition should be consistent with real reactor core state for the simulation of the core transient. The initial xenon distribution, which cad not be measured in the core, has a significant effect on the transient with xenon dynamics of PWR. In the simulation of the transient stating from non-equilibrium xenon state, the accurate initialization of the non-equilibrium xenon distribution is essential to predict the core transient behavior. In this study, the xenon initialization method to predict the core transient more accurately was developed through the first-order perturbation theory of the relationship between simulated power and measured power distribution and verified by the application of the simulation for a startup test of Yonggwang Unit 3.

  • PDF

Study on the Natural Convection Heat Transfer Characteristics in the Air Duct

  • Kim, Y.K.;Lee, Y.B.;Park, S.K.;J.S. Hwang;H.Y. Nam
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.451-456
    • /
    • 1997
  • Temperature distribution measurements in the mockup apparatus of reactor vessel were performed to determine the effective thermal conductivity of porous media with different geometry and to obtain the experimental data for the heat transfer processes by natural convection occurring in the air duct. The temperature distributions at four separated sections with different arrangements of porous media have different slopes according to the geometrical configuration. From the measured temperature distribution, effective thermal conductivity have been derived using the least square fitting method. The test at air duct was performed to the high heat removal at 3.4kW/$m^2$ by the natural convection from the outer wall to the air. And also the temperature distributions in the air duct agree well with the 1/7th power-law turbulent temperature distribution. The obtained heat transfer data have been compared with the Shin's and Sieger's correlations.

  • PDF

EXPERIMENTAL ANALYSES OF SPALLATION NEUTRONS GENERATED BY 100 MEV PROTONS AT THE KYOTO UNIVERSITY CRITICAL ASSEMBLY

  • Pyeon, Cheol Ho;Azuma, Tetsushi;Takemoto, Yuki;Yagi, Takahiro;Misawa, Tsuyoshi
    • Nuclear Engineering and Technology
    • /
    • v.45 no.1
    • /
    • pp.81-88
    • /
    • 2013
  • Neutron spectrum analyses of spallation neutrons are conducted in the accelerator-driven system (ADS) facility at the Kyoto University Critical Assembly (KUCA). High-energy protons (100 MeV) obtained from the fixed field alternating gradient accelerator are injected onto a tungsten target, whereby the spallation neutrons are generated. For neutronic characteristics of spallation neutrons, the reaction rates and the continuous energy distribution of spallation neutrons are measured by the foil activation method and by an organic liquid scintillator, respectively. Numerical calculations are executed by MCNPX with JENDL/HE-2007 and ENDF/B-VI libraries to evaluate the reaction rates of activation foils (bismuth and indium) set at the target and the continuous energy distribution of spallation neutrons set in front of the target. For the reaction rates by the foil activation method, the C/E values between the experiments and the calculations are found around a relative difference of 10%, except for some reactions. For continuous energy distribution by the organic liquid scintillator, the spallation neutrons are observed up to 45 MeV. From these results, the neutron spectrum information on the spallation neutrons generated at the target are attained successfully in injecting 100 MeV protons onto the tungsten target.

The Stress Distribution Analysis of PEMFC GDL using FEM (유한요소법을 이용한 고분자전해질연료전지 기체확산층의 응력분포 연구)

  • Kim, Chulhyun;Sohn, Youngjun;Park, Gugon;Kim, Minjin;Lee, Jonguk;Kim, Changsoo;Choi, Yusong;Cho, Sungbaek
    • Journal of Hydrogen and New Energy
    • /
    • v.23 no.5
    • /
    • pp.468-475
    • /
    • 2012
  • A proper stacking force and assembly are important to the performance of fuel cell. Improper assembly pressure may lead to leakage of fuels and high interfacial contact resistance, excessive assembly pressure may result in damage to the gas diffusion layer and other components. The pressure distribution of gas diffusion layer is important to make interfacial contact resistance less for stack performance. To analyze the influence of design parameter factors for pressure distribution, and to optimize stack design, DOE (Design of Experiment) was used for polymer electrolyte membrane fuel cell stack pressure test. As commonly known, the higher clamping force improves the fuel cell stack performance. However, non-uniformity of stress distribution is also increased. It shows that optimization between clamping force and stress distribution is needed for well designed structure of fuel cell stack. In this study, stack design optimization method is suggested by using FEM (Finite Element Methode) and DOE for light-weighted fuel cell stack.

Comparison on the Energy Performance of Underfloor Air Distribution System According to Modeling Method Using EnergyPlus (EnergyPlus를 이용한 바닥공조시스템의 모델링 방법에 따른 에너지 성능 비교)

  • Jang, Hyang-In;Yoon, Seong-Hoon;Lee, Hyun-Soo;Suh, Seung-Jik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.10
    • /
    • pp.718-723
    • /
    • 2012
  • The purpose of this study is to propose modeling method of Underfloor Air Distribution System with reliability and validity by comparing characteristics of modeling methods. For this, the modeling methods of UFAD were selected by investigating various modeling methods of previous researches. Then, simulations were conducted by using EnergyPlus which is dynamic analysis program of building energy. Annual energy consumption for each method was compared with a wide range of indoor thermal loads. As a result, the methodology of reducing internal gains can cause under sizing of the system. It suggests modeling methods to reflect occupied zone air-conditioning, temperature stratification and supply plenum which are the main characteristics of UFAD.

Development of Flux Mapping Technique for the Solar Power Tower Plant (타워형 태양열발전을 위한 열유속 분포 측정기술 개발)

  • Chai, Kwan-Kyo;Lee, Hyun-Jin;Kim, Jong-Kyu;Yoon, Hwan-Ki;Lee, Sang-Nam;Kang, Yong-Heack;Seo, Tae-Beom
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.274-279
    • /
    • 2012
  • Daegu Solar Power Tower Plant of 200 kW thermal capacity was developed for the first time in Korea, 2011. Measurement of the heat flux distribution is essential to evaluate the solar energy concentrated by reflectors and to design a suitable receiver. The flux mapping technique, which uses a radiometer and a diffuse plate, is common for measurement of the heat flux distribution. Because the solar power tower plant has a wide concentration area, the flux mapping technique using a fixed diffuse plate is difficult to apply. Therefore, the flux distribution in the solar power tower plant should be measured by the flux mapping technique using a small moving bar. In this study, we measured flux distributions with the moving-bar system developed at the KIER solar furnace and evaluated its applicability for the solar power tower plant.

  • PDF

Artificial Intelligence Application using Nutcracker Optimization Algorithm to Enhance Efficiency & Reliability of Power Systems via Optimal Setting and Sizing of Renewable Energy Sources as Distributed Generations in Radial Distribution Systems

  • Nawaf A. AlZahrani;Mohammad Hamza Awedh;Ali M. Rushdi
    • International Journal of Computer Science & Network Security
    • /
    • v.24 no.1
    • /
    • pp.31-44
    • /
    • 2024
  • People have been using more energy in the last years. Several research studies were conducted to develop sustainable energy sources that can produce clean energy to fulfill our energy requirements. Using renewable energy sources helps to decrease the harm to the environment caused by conventional power plants. Choosing the right location and capacity for DG-RESs can greatly impact the performance of Radial Distribution Systems. It is beneficial to have a good and stable electrical power supply with low energy waste and high effectiveness because it improves the performance and reliability of the system. This research investigates the ideal location and size for solar and wind power systems, which are popular methods for producing clean electricity. A new artificial intelligent algorithm called Nutcracker Optimization Algorithm (NOA) is used to find the best solution in two common electrical systems named IEEE 33 and 69 bus systems to examine the improvement in the efficiency & reliability of power system network by reducing power losses, making voltage deviation smaller, and improving voltage stability. Finally, the NOA method is compared with another method called PSO and developed Hybrid Algorithm (NOA+PSO) to validate the proposed algorithm effectiveness and enhancement of both efficiency and reliability aspects.

Development of Precise Beta Dosimeter (사고시 대응 정밀 베타선량계 개발)

  • Lee, Won-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.468-470
    • /
    • 1996
  • The use of thermoluminescent dosimeters (TLDs) for beta dosimetry has been encumbered by the energy-dependent responses of TLDs to beta radiation. This energy-dependent response is due to the low penetrating ability of beta particles. Thus the determination of the beta dose imparted to an exposed TLD chip can be accurately determined only if the energy distribution of beta radiation is correctly accounted for. So precise beta dosimeter used TLD chips place under several aluminum filters of varying thicknesses and developed to correctly determine doses due to radiation fields where the beta energy distribution is unknown.

  • PDF