• Title/Summary/Keyword: energy distance

Search Result 1,894, Processing Time 0.031 seconds

Effects of Pipe Network Composition and Length on Power Plant Waste Heat Utilization System Performance for Large-scale Horticulture Facilities (발전소 온배수를 적용한 대규모 시설원예단지용 난방시스템의 열원이송 배관 재질 및 거리에 따른 성능평가)

  • Lee, Keum ho;Lee, Jae Ho;Lee, Kwang Ho
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.4
    • /
    • pp.14-21
    • /
    • 2015
  • Korean government plans to establish large-scale horticulture facility complexes using reclaimed land in order to improve the national competitiveness of agriculture at the government level. One of the most significant problems arising from the establishment of those large-scale horticulture facilities is that these facilities still largely depend on a fossil fuel and they require 24 h a day heating during the winter season in order to provide the necessary breeding conditions for greenhouse crops. These facilities show large energy consumption due to the use of coverings with large heat transmission coefficients such as vinyl and glass during heating in the winter season. This study investigated the applicability of waste heat from power plant for large-scale horticulture facilities by evaluating the waste heat water temperature, heat loss and energy saving performance as a function of distance between power plant and greenhouse. As a result, utilizing power plant waste heat can reduce the energy consumption by around 85% compared to the conventional gas boiler, regardless of the distance between power plant and greenhouse.

Performance Improvements for Silence Feature Normalization Method by Using Filter Bank Energy Subtraction (필터 뱅크 에너지 차감을 이용한 묵음 특징 정규화 방법의 성능 향상)

  • Shen, Guanghu;Choi, Sook-Nam;Chung, Hyun-Yeol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.7C
    • /
    • pp.604-610
    • /
    • 2010
  • In this paper we proposed FSFN (Filter bank sub-band energy subtraction based CLSFN) method to improve the recognition performance of the existing CLSFN (Cepstral distance and Log-energy based Silence Feature Normalization). The proposed FSFN reduces the energy of noise components in filter bank sub-band domain when extracting the features from speech data. This leads to extract the enhanced cepstral features and thus improves the accuracy of speech/silence classification using the enhanced cepstral features. Therefore, it can be expected to get improved performance comparing with the existing CLSFN. Experimental results conducted on Aurora 2.0 DB showed that our proposed FSFN method improves the averaged word accuracy of 2% comparing with the conventional CLSFN method, and FSFN combined with CMVN (Cepstral Mean and Variance Normalization) also showed the best recognition performance comparing with others.

Energy Consumption Evaluation in Pumping System with Different Building Characteristics (건물 특성에 따른 냉수 순환 펌핑 시스템 별 에너지 소모량 분석)

  • Shin, Dong-Shin;Park, Sung-Bin;Jun, Tae-Ik;Ma, Kang-Il;Kim, Tae-Hong;Lee, Sung-Goo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.242-247
    • /
    • 2016
  • This study analyzed the energy consumption of a building pump system that was originally equipped with a primary-secondary zone pump system. Using the HYSYS program the energy consumption of the primary pump system was compared with the primary-secondary zone pump system. The primary-secondary zone pump system consumes less energy than the originally designed primary pump system. When the distance between the machine room and each building is assumed to be equal, the primary pump system can be more efficient than the primary-secondary zone pump system with decreasing the distance. When the distance is 120 m, the primary system consumes less total annual energy than the primary-secondary zone pump system and saves 2,773 kWh. The suggested energy evaluation program can be useful if the designer seeks a more efficient pump system.

A Study on Remediation of Chlorinated Hydrocarbons and Explosives using Pulsed-UV System (Pulsed-UV 시스템을 이용한 염소계 유기화합물 및 화약류 제거에 관한 연구)

  • Lee, Han-Uk;Han, Jonghun;Yoon, Yeomin;Lee, Jongyeol;Her, Namguk
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.1
    • /
    • pp.78-84
    • /
    • 2013
  • This study was conducted in order to evaluate the removal process for long-term contamination sources including chlorinated hydrocarbons (TCE and PCE) and explosive compounds (TNT, RDX, and HMX) in underground water using a pulsed-UV system. Crystallized cells containing the contaminants were placed 10, 20, and 40 cm away from a lamp that emits pulsed-UV rays in order to examine how the removal efficiency is influenced by the distance between the source of the light and the compounds. Chlorinated hydrocarbons were completely removed in 30 minutes with a distance of 10 cm, while PCE was completely removed even with a distance of 20 cm. In the case of explosive compounds, removal efficiencies slightly varied depending on the compounds. The majority of the compounds were perfectly removed with a contact time of 10 minutes. In particular, for RDX, the results showed that complete removal was obtained within one minute, regardless of the distance from the UV source. The amount of light energy is in inverse proportion to the distance, and thus the energy reaching the compounds severely diminishes as the distance increases. Therefore, the removal efficiency decreased with increasing distance in the system.

Enhanced ML-LEACH with additional Relay Node

  • Jin, Seung Yeon;Jung, Kye-Dong;Lee, Jong-Yong
    • International journal of advanced smart convergence
    • /
    • v.6 no.3
    • /
    • pp.9-16
    • /
    • 2017
  • In this paper, we propose a new routing protocol for wireless sensor networks. This protocol improves energy consumption of ML-LEACH by reducing the transmission distance of member node via Relay Node. Since clusters of each Layer in ML-LEACH are randomly formed, the distance, between member node and cluster head may be longer than specific distance, distance threshold value. To improve this, we propose the new routing protocol using 2-Hop transmission via Relay Node depending on the transmission distance of the member node.

Min-Distance Hop Count based Multi-Hop Clustering In Non-uniform Wireless Sensor Networks

  • Kim, Eun-Ju;Kim, Dong-Joo;Park, Jun-Ho;Seong, Dong-Ook;Lee, Byung-Yup;Yoo, Jae-Soo
    • International Journal of Contents
    • /
    • v.8 no.2
    • /
    • pp.13-18
    • /
    • 2012
  • In wireless sensor networks, an energy efficient data gathering scheme is one of core technologies to process a query. The cluster-based data gathering methods minimize the energy consumption of sensor nodes by maximizing the efficiency of data aggregation. However, since the existing clustering methods consider only uniform network environments, they are not suitable for the real world applications that sensor nodes can be distributed unevenly. To solve such a problem, we propose a balanced multi-hop clustering scheme in non-uniform wireless sensor networks. The proposed scheme constructs a cluster based on the logical distance to the cluster head using a min-distance hop count. To show the superiority of our proposed scheme, we compare it with the existing clustering schemes in sensor networks. Our experimental results show that our proposed scheme prolongs about 48% lifetime over the existing methods on average.

Waveform characterization and energy dissipation of stress wave in sandstone based on modified SHPB tests

  • Cheng, Yun;Song, Zhanping;Jin, Jiefang;Wang, Tong;Yang, Tengtian
    • Geomechanics and Engineering
    • /
    • v.22 no.2
    • /
    • pp.187-196
    • /
    • 2020
  • The changeable stress environment directly affect the propagation law of a stress wave. Stress wave propagation tests in sandstone with different axial stresses were carried using a modified split Hopkinson Pressure bar (SHPB) assuming the sandstone has a uniform pore distribution. Then the waveform and stress wave energy dissipation were analyzed. The results show that the stress wave exhibits the double peak phenomenon. With increasing axial stress, the intensity difference decreases exponentially and experiences first a dramatic decrease and then gentle development. The demarcation stress is σ/σc=30%, indicating that the closer to the incident end, the faster the intensity difference attenuates. Under the same axial stress, the intensity difference decreases linearly with propagation distance and its attenuation intensity factor displays a quadratic function with axial stress. With increasing propagation distance, the time difference decays linearly and its delay coefficient reflects the damage degree. The stress wave energy attenuates exponentially with propagation distance, and the relations between attenuation rate, attenuation coefficient and axial stress can be represented by the quadratic function.

Effect of the grain boundary on the magnetic properties of the multi-seeded melt growth processed YBCO superconductors (다중종자결정성장법으로 제조한 YBCO 초전도체의 결정입계에 따른 자기적 성질의 영향)

  • Kim, Chan-Joong;Joo, Jin-Ho;Han, Young-Hee;Han, Sang-Chul;Sung, Tae-Hyun;Hong, Gye-Won;Kim, Ho-Jin
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.293-297
    • /
    • 2000
  • Multiseeding with (100)/(100) grain junctions of top-seeded melt growth (TSMG) processed YBCO superconductors was studied. The effect of the number of seeds and the distance between two seeds on the levitation forces and the trapped magnetic fields of the TSMG-processed YBCO samples was investigated. Multiple seeding shortened the processing time for the fabrication of TSMC-processed YBCO superconductors. The large magnetic field was trapped at the grain junction when two seeds was placed without spacing, while the amount of the magnetic field decreased when the seed distance increased. This is attributed to the increased amount of the residual melt phases around the grain junctions.

  • PDF

A Design Optimization on Coupling Joint between Exhaust Chimney of Electricity Generator and Electromagnetic Pulse (EMP) Shield (EMP 차폐를 위한 비상발전기 연도의 최적 형상 결정)

  • Pang, Seung-Ki;Kim, Jae-Hun
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.159-165
    • /
    • 2015
  • The article presents a parametric study on geometrical design optimization for coupling the joint between a large exhaust air chimney and electromagnetic pulse (EMP) shield for gas turbine electricity generator. We conducted computational fluid dynamics (CFD) simulations on hydraulic diameters of waveguide below cutoff(WBC) ranges 800mm~1025mm, the connection distance ranges 150~450mm, and exhaust gas flow velocities at 15, 20, and 25m/s. The results show that the diameter of main chimney, connection distance, and exhaust gas velocity had impacts on flow stream at the EMP shield. To provide a fully developed stream line at three different flow velocity cases, the WBC diameter and distance of connection should be larger than 1050mm and longer than 300mm, respectively.