• 제목/요약/키워드: energy dissipation factor

Search Result 119, Processing Time 0.037 seconds

스퍼어 기거의 밀폐단조에 관한 상계해석

  • 최재찬;허관도;김창호;최종용
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.52-56
    • /
    • 1992
  • A kinematically admissible velocity field for closed-die forging of spur gear is proposed. The velocity field is divided into three regions of deformation. In the analysis, the involute curve is approximated to be straight line and the upper-bound method is used to calculate energy dissipation rate. A constant frictional factor has been assumed on the contacting surfaces. The effects of root diameter relative pressure is independent of root diameter for the same number of teeth, but increases with the number of teeth on a given root diameter. In the presence of friction, relative forging pressure increases with increasing root diameter at the start of forging, but decreases with increasing root diameter in the processing of forging.

Nonlinear finite element analysis of effective CFRP bonding length and strain distribution along concrete-CFRP interface

  • Dogan, Ali Baran;Anil, Ozgur
    • Computers and Concrete
    • /
    • v.7 no.5
    • /
    • pp.437-453
    • /
    • 2010
  • CFRP has been widely used for strengthening reinforced concrete members in last decade. The strain transfer mechanism from concrete face to CFRP is a key factor for rigidity, ductility, energy dissipation and failure modes of concrete members. For these reasons, determination of the effective CFRP bonding length is the most crucial step to achieve effective and economical strengthening. In this paper, generalizations are made on effective bonding length by increasing the amount of test data. For this purpose, ANSYS software is employed, and an experimentally verified nonlinear finite element model is prepared. Special contact elements are utilized along the concrete-CFRP strip interface for investigating stress distribution, load-displacement behavior, and effective bonding length. Then results are compared with the experimental results. The finite element model found consistent results with the experimental findings.

The Improvement of Radiation Characteristics of Low Density Polyethylene by Adding Treeing Inhibitors (I) (트리억제제 첨가에 의한 저밀도 폴리에틸렌의 내방사선성 향상 (I))

  • Kim, Ki-Yup;Lee, Chung;Ryu, Boo-Hyung;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.926-928
    • /
    • 1999
  • Treeing inhibitors of barbituric acid derivatives effects on the electrical properties of crosslinked low density polyethylene under radiation environments were investigated. The electrical parameters for tree inception voltage, AC breakdown strength, volume resistivity, capacitance and dissipation factor at 1MHz and thermoluminescence, gel content measurements were discussed as a function of irradiated dosages. From the results, barbituric acid among the treeing inhibitors was shown the best treeing and radiation resistance.

  • PDF

Structural Behavior of RC Columns with Mechanically Anchored Crossties under Cyclic Loading (기계적 정착된 전단보강근을 가진 RC 기둥의 구조적 거동)

  • Lee, Sung-Ho;Chun, Sung-Chul;Oh, Bo-Hwan;Nah, Hwan-Sean;Kim, Sang-Koo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.59-62
    • /
    • 2005
  • Seven columns laterally reinforced with either mechanically anchored crossties or conventional crossties under cyclic loading are tested. 4 columns are specimens for flexural strength and 3 columns are for shear strength. Main variable is anchorage types of crossties. Conventional hooks, 180$^{\circ}$ standard hook-mechanical anchorage and all mechanical anchorage type are used. The specimens are tested under 10$\%$ axial load of nominal axial capacity of the columns combined with increasing lateral load. From the flexure test, it is found that columns with mechanical anchorages exhibit superior performance in terms of ductility and energy dissipation. The crossties with mechanical anchorages reduce buckling length of longitudinal rebar. From the shear test, it is found that. 3 specimens exhibit almost the same strength, displacement, and shear failure mode at ductility factor =2.

  • PDF

Structural Performance of Seismic Resistance Capacity of Carbon Sheet-Angle Retrofitting Method in Wall-Slab Joint (탄소섬유와 L형강을 이용한 벽-슬래브 접합부의 보강성능)

  • Roh Gong-Ki;Park Tae-Won;Park Hyun-Soo;Chung Lan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.65-68
    • /
    • 2004
  • In the seismical capacity evaluation for RC structure wall-slab joint is very important factor. Because lateral load is resistance element and gravity load resistance element are acted mutually in the wall-slab joint. In this paper, to improve the seismic capacity of the wall-slab joint in the existing wall type apartments experiment which improve and retrofit a seismic capacity by unequal angle bracing and carbon sheet attachment are carried out. These methods are also economic and simple in mitigating seismic hazard, improve earthquake-resistance performance, and reduce risk level of building occupants. From the experimental results, the change of strength, degration of stiffness, and energy dissipation are evaluated. It can be concluded that these methods are effective in improving the seismic performance.

  • PDF

A Study on the Development of Guryongpo Harbour and Its Impact (구룡포항의 개발과 파급효과에 관한 연구)

  • 이종우
    • Journal of the Korean Institute of Navigation
    • /
    • v.14 no.1
    • /
    • pp.39-55
    • /
    • 1990
  • Numerical model simulations are conducted for the evaluation of the water level variation in and out of the harbor due to the development and improvement of a harbor. The method used for the numerical analysis is the hybrid element method which includes energy dissipation due to imperfect reflection at the shore boundary and friction at the bottom. The model also includes the radiation condition on the open boundary by the analytic formulation and is applied to a real harbor, Guryongpo Harbor at the east coast of Korea. The result of experiment within the selected wave frequency band shows that the amplification factor out of the harbor is more than 2.0 at 32 sec period and strong responses near 20 sec, 25 sec, 54 sec periods in the harbor. Moreover, simulation results indicate that other longer wave periods affect to the variation of water level and horizontal water particle velocity exist. Thus, it seems to be necessary to modify the planform and the design of the harbor structures for the coming development.

  • PDF

The Significance of Transverse Shear on Vibration Damping of 90-degree Unidirectional Laminated Composites (단일방향 $90^{\circ}$적층 보의 횡전단응력이 진도감쇠에 미치는 효과)

  • 임종휘
    • Journal of KSNVE
    • /
    • v.10 no.1
    • /
    • pp.57-63
    • /
    • 2000
  • On the basis of the concept of strain energy-weighted dissipation, an enhanced model for predicting damping in laminates is presented. In this model, the influence of transverse shear on $90^{\circ}$ laminates has been included with those of in-plane stresses on beam. Also, an experimental damping measurement is conducted with changing the length and the thickness of laminated beam specimen for confirmation of the model prediction. The theoretical predictions in $90^{\circ}$laminates were reasonably compared with experimental data. The transverse shear reveals to have an influence on the damping, behavior in $90^{\circ}$ laminates.

  • PDF

Effects of pulse-like nature of forward directivity ground motions on the seismic behavior of steel moment frames

  • Mansouri, Iman;Shahbazi, Shahrokh;Hu, Jong Wan;Moghaddam, Salar Arian
    • Earthquakes and Structures
    • /
    • v.17 no.1
    • /
    • pp.1-15
    • /
    • 2019
  • In the structures with high level of ductility, the earthquake energy dissipation in structural components is an important factor that describes their seismic behavior. Since the connection details play a major role in the ductile behavior of structure, in this paper, the seismic response of 3-, 5- and 8-story steel special moment frames (SMFs) is investigated by considering the effects of panel zone modeling and the influence of forward-directivity near-field ground motions. To provide a reasonable comparison, selected records of both near and far-field are used in the nonlinear time-history analysis of models. The results of the comparison of the median maximum inter-story drift under excitation by near-field (NF) records and the far-field (FF) ground motions show that the inter-story drift demands can be obtained 3.47, 4.86 and 5.92 times in 3-, 5- and 8-story structures, respectively, undergoing near-field earthquakes.

Experimental study on lateral behavior of precast wide beam-column joints

  • Kim, Jae Hyun;Jang, Beom Soo;Choi, Seung-Ho;Lee, Yoon Jung;Jeong, Ho Seong;Kim, Kang Su
    • Earthquakes and Structures
    • /
    • v.21 no.6
    • /
    • pp.653-667
    • /
    • 2021
  • In this study, cyclic loading tests were conducted on the precast concrete (PC) wide beam (WB)-column joints. Two beam-column joint specimens were fabricated with the arrangement and anchorage details of the reinforcing bars penetrating the beam and column as variables. Through a cyclic loading test, the lateral load-story drift ratio responses, seismic performance characteristics (e.g., ductility, overstrength factor), energy dissipation, strength and stiffness degradations of each specimen were compared and analyzed based on the various indices and the current structural codes (ACI 318-19 and ACI 374.1-05 report). In addition, the shear lag effect was confirmed through the gauge values of the PC beam, and the differences in seismic performance between the specimens were identified on that basis.

Cyclic testing of chevron braced steel frames with IPE shear panels

  • Zahrai, Seyed Mehdi
    • Steel and Composite Structures
    • /
    • v.19 no.5
    • /
    • pp.1167-1184
    • /
    • 2015
  • Despite considerable life casualty and financial loss resulting from past earthquakes, many existing steel buildings are still seismically vulnerable as they have no lateral resistance or at least need some sort of retrofitting. Passive control methods with decreasing seismic demand and increasing ductility reduce rate of vulnerability of structures against earthquakes. One of the most effective and practical passive control methods is to use a shear panel system working as a ductile fuse in the structure. The shear Panel System, SPS, is located vertically between apex of two chevron braces and the flange of the floor beam. Seismic energy is highly dissipated through shear yielding of shear panel web while other elements of the structure remain almost elastic. In this paper, lateral behavior and related benefits of this system with narrow-flange link beams is experimentally investigated in chevron braced simple steel frames. For this purpose, five specimens with IPE (narrow-flange I section) shear panels were examined. All of the specimens showed high ductility and dissipated almost all input energy imposed to the structure. For example, maximum SPS shear distortion of 0.128-0.156 rad, overall ductility of 5.3-7.2, response modification factor of 7.1-11.2, and finally maximum equivalent viscous damping ratio of 35.5-40.2% in the last loading cycle corresponding to an average damping ratio of 26.7-30.6% were obtained. It was also shown that the beam, columns and braces remained elastic as expected. Considering this fact, by just changing the probably damaged shear panel pieces after earthquake, the structure can still be continuously used as another benefit of this proposed retrofitting system without the need to change the floor beam.