• 제목/요약/키워드: energy correction

검색결과 645건 처리시간 0.029초

지상관측 자료를 이용한 AMSR2 토양수분자료의 편이 보정 (Bias Correction of AMSR2 Soil Moisture Data Using Ground Observations)

  • 김묘정;김광섭;이재응
    • 한국농공학회논문집
    • /
    • 제57권4호
    • /
    • pp.61-71
    • /
    • 2015
  • Quantitative variability of AMSR2 (Advanced Microwave Scanning Radiometer 2) soil moisture data shows that the remotely sensed soil moisture is underestimated during Spring and Winter seasons and is overestimated during Summer and Fall seasons. Therefore the bias correction of the remotely sensed data is essential for the purpose of water resource management. To enhance their applicability, the bias of AMSR2 soil moisture data was corrected using ground observation data at Cheorwon Chuncheon, Suwon, Cheongju, Jeonju, and Jinju sites. Test statistics demonstrated that the correlation coefficient R is improved from 0.107~0.328 to 0.286~0.559 and RMSE is improved from 9.46~14.36 % to 5.38~9.62 %. Bias correction using ground network data improved the applicability of remotely sensed soil moisture data.

역률개선을 위한 자기에너지 궤환기법의 단일전력단 AC/DC 컨버터의 해석 및 구현 (Analysis and Implementation of Single-Stage AC/DC Converter with Magnetic Energy Feedback Technique for Power Factor Correction)

  • 문건우;오관일;전영수
    • 전력전자학회논문지
    • /
    • 제3권2호
    • /
    • pp.148-155
    • /
    • 1998
  • 역률개선을 위한 변압기 자기에너지 궤환 기법을 이용한 새로운 단일 전력단, 단일 스위치 방식의 AC/DC 컨버터를 제안한다. 제안한 컨버터의 동작원리 및 해석을 수행하였다. 제안한 컨버터는 선전류 고조파 왜곡이 작으며 고역률 및 정확한 전압 조정이 가능하다. 실험모델은 단일 역률에 가까운 역률을 보이며 IEC 555-2를 충분히 만족시킨다.

부피법을 이용한 고압·극저온 수소 흡착량 측정 방식의 기본 원리 (Volumetric Hydrogen Sorbent Measurement at High Pressure and Cryogenic Condition - Basic Measurement Protocols)

  • 오현철
    • 한국수소및신에너지학회논문집
    • /
    • 제27권4호
    • /
    • pp.349-356
    • /
    • 2016
  • Volumetric capacity metrics at cryogenic condition are critical for technological and commercial development. It must be calculated and reported in a uniform and consistent manner to allow comparisons among different materials. In this paper, we propose a simple and universal protocol for the determination of volumetric capacity of sorbent materials at cryogenic condition. Usually, the sample container volume containing porous sample at RT can be directly determined by a helium expansion test. At cryogenic temperatures, however, this direct helium expansion test results in inaccurate values of the sample container volume for microporous materials due to a significant helium adsorption, resulting significant errors in hydrogen uptake. For reducing this container volume error, therefore, we introduced and applied the indirect method such as 'volume correction using a non-porous material', showing a reliable cold volume correction.

Energy Savings in OFDM Systems through Cooperative Relaying

  • Khuong, Ho Van;Kong, Hyung-Yun
    • ETRI Journal
    • /
    • 제29권1호
    • /
    • pp.27-35
    • /
    • 2007
  • Energy savings in orthogonal frequency division multiplexing (OFDM) systems is an active research area. In order to achieve a solution, we propose a new cooperative relaying scheme operated on a per subcarrier basis. This scheme improves the bit error rate (BER) performance of the conventional signal-to-noise ratio (SNR)-based selection relaying scheme by substituting SNR with symbol error probability (SEP) to evaluate the received signal quality at the relay more reliably. Since the cooperative relaying provides spatial diversity gain for each subcarrier, thus statistically enhancing the reliability of subcarriers at the destination, the total number of lost subcarriers due to deep fading is reduced. In other words, cooperative relaying can alleviate error symbols in a codeword so that the error correction capability of forward error correction codes can be fully exploited to improve the BER performance (or save transmission energy at a target BER). Monte-Carlo simulations validate the proposed approach.

  • PDF

초기상승법에 의해 계산된 활성화 에너지의 오차보정에 관한 연구 (Study on the Correction of Error Involved in Activation Energies Calculated by the Initial Rise Method)

  • 류강식;추영배;류부형;김봉협
    • 대한전기학회논문지
    • /
    • 제38권3호
    • /
    • pp.193-200
    • /
    • 1989
  • The errors of activation energy calculated by the initial rise method from the characteristics of thermally stimulated current have been estimated and an equation for the correction of the error is proposed. The coefficients needed in the proposed equation are determined by the numerical method. It is shown that the activation energy calculated by the conventional initial rise method contains errors of 0.7-10% depending on the location of the data points of the interval on which the method is applied. However, the error can be reduced to less than 0.5% when corrected by using the proposed equation. It is finally concluded that the activation energy determined by the initial rise method can approach the true value by adapting the proposed error correction method which is effective and reliable.

  • PDF

Detector Foil Self-Shielding Correction Factors

  • Kwon, Oh-Sun;Kim, Bong-Ghi;Suk, Ho-Chun
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(1)
    • /
    • pp.197-201
    • /
    • 1996
  • In the detail reaction-rate measurements in a critical assembly using the foil activation method, the measured activations of detector foils have inevitably errors caused by detector foil self-shielding effect. If neutron flux could be approximated to Westcott flux: i.e. well thermalized Maxwellian distribution, these activations of detector foil could be corrected to represent the unperturbated flux at any detected position in the cell with using Westcott option and reaction-rate option of the lattice code, WIMS-AECL. These calculated detector material self-shielding correction factors of the tested fuel, CANFLEX provided much information about neutron spectrum of test lattice cell as well as the correction factors themselves. The results could be verified by another lattice calculations.

  • PDF

역률보상회로를 이용한 이동통신 중계기의 에너지 절감에 관한 연구 (Study on the energy savings in the mobile communication repeater using a power factor correction circuit)

  • 임병철;윤원식
    • 한국정보통신학회논문지
    • /
    • 제18권8호
    • /
    • pp.1854-1860
    • /
    • 2014
  • 본 논문에서 이동통신 중계기를 위한 에너지 절감방법에 대한 연구를 수행하였다. 현재 실제 현장에서 서비스하고 있는 DB(Dual Band)소형 중계기에 있는 SMPS(Switching Mode Power Supply)에 PFC(Power Factor Correction)를 추가하여 전력소모를 감소하였으며, 이를 실제 구현하여 검증함으로써 실증된 결과를 도출하였다. 실증결과 장비 1식당 약 38.9% 피상전력 개선효과를 확인하였으며, 이를 연간으로 환산해 보면 약 230.43kWh의 에너지 절감효과가 있다.

전자빔 리소그래피에서의 근접효과 보정을 이용한 패턴 제작에 관한 연구 (A Study on Pattern Fabrication using Proximity Effect Correction in E-Beam Lithography)

  • 오세규;김동환;김승재
    • 반도체디스플레이기술학회지
    • /
    • 제8권2호
    • /
    • pp.1-10
    • /
    • 2009
  • This study describes the electron beam lithography pattern fabrication using the proximity effect correction. When electron beam exposes into electron beam resist, the beam tends to spread inside the substance (forward scattering). And the electron beam reflected from substrate spreads again (back scattering). These two effects influence to distribution of the energy and give rise to a proximity effect while a small pattern is generated. In this article, an electron energy distribution is modeled using Gaussian shaped beam distribution and those parameters in the model are computed to solidify the model. The proximity effect is analyzed through simulations and appropriate corrections to reducing the proximity effect are suggested. It is found that the proximate effect can be reduced by adopting schemes of dose adjustment, and the optimal dose is determined through simulations. The proposed corrected proximity effect correction is proved by experiments.

  • PDF

A Correction Method for the Peak Tailing Backgrounds for Accurate Isotope Ratio Measurements of Uranium in Ultra Trace Levels using Thermal Ionization Mass Spectrometry

  • Park, Jong-Ho;Choi, In-Hee;Park, Su-Jin;Lee, Myung-Ho;Song, Kyu-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권12호
    • /
    • pp.4327-4331
    • /
    • 2011
  • A new method in thermal ionization mass spectrometry (TIMS) was developed to correct peak tailing backgrounds in the isotope ratio measurements of uranium in ultra trace levels for higher accuracy. Two different uranium standard reference materials (U005 and U030) were used to construct databases of signal intensities at mass 234 u and mass 236 u, which correspond to the two uranium minor isotopes, and signal intensity of $^{238}U$. Correlations between peak tailing backgrounds and $^{238}U$ were obtained by least-squares regression on calculated backgrounds at mass 234 u and mass 236 u with respect to the signal intensity of $^{238}U$ followed by separation of the peak tails of the two major isotopes of uranium ($^{235}U$ and $^{238}U$), which enables us to obtain a master equation for peak tailing background correction on all kinds of samples. Verification of the correction method was carried out using U010 and IRMM-040a.

Study of neutron energy and directional distribution at the Beloyarsk NPP selected workplaces

  • Pyshkina, Mariia;Vasilyev, Aleksey;Ekidin, Aleksey;Nazarov, Evgeniy;Nikitenko, Vitaly;Pudovkin, Anton
    • Nuclear Engineering and Technology
    • /
    • 제53권5호
    • /
    • pp.1723-1729
    • /
    • 2021
  • Energy and directional distribution of neutrons at the Beloyarsk NPP workplaces is a subject of this study. Measurements of H*(10) rate and neutron energy distribution were taken at 8 workplaces, which can be divided into three categories: work with spent or fresh nuclear fuel, work with radionuclide neutron sources, work at the rooms adjusted to reactors. The Hp(10) measurements were performed only at 6 out of 8 locations, due to the fact that long term placing of an effective neutron moderator in fresh nuclear fuel storage facility is forbidden. As a result of the research energy and direction distribution of the neutron fields at 8 locations of the Beloyarsk NPP workplaces was obtained. To estimate the accuracy of the H*(10) rate and Hp (10) measurements the reference values of dose equivalents were calculated using energy and directional distribution. To take into account the difference between the reference values and the measured results site-specific correction factors were calculated.