• Title/Summary/Keyword: energy company

Search Result 814, Processing Time 0.02 seconds

Preparation of Cathode Materials for Lithium Rechargeable Batteries using Transition Metals Recycled from Li(Ni1-x-yCoxMny)O2 Secondary Battery Scraps (Li(Ni1-x-yCoxMny)O2계 이차전지 공정 스크랩으로부터 회수한 전이금속을 활용한 리튬이차전지 양극재 제조)

  • Lee, Jae-Won;Kim, Dae Weon;Jang, Seong Tae
    • Journal of Powder Materials
    • /
    • v.21 no.2
    • /
    • pp.131-136
    • /
    • 2014
  • Cathode materials and their precursors are prepared with transition metal solutions recycled from the the waste lithium-ion batteries containing NCM (nickel-cobalt-manganese) cathodes by a $H_2$ and C-reduction process. The recycled transition metal sulfate solutions are used in a co-precipitation process in a CSTR reactor to obtain the transition metal hydroxide. The NCM cathode materials (Ni:Mn:Co=5:3:2) are prepared from the transition metal hydroxide by calcining with lithium carbonate. X-ray diffraction and scanning electron microscopy analyses show that the cathode material has a layered structure and particle size of about 10 ${\mu}m$. The cathode materials also exhibited a capacity of about 160 mAh/g with a retention rate of 93~96% after 100 cycles.

Sludge Returned CMAS에 의한 전기부속품제조공장 폐수처리

  • 김남천;이시진
    • Microbiology and Biotechnology Letters
    • /
    • v.25 no.4
    • /
    • pp.427-433
    • /
    • 1997
  • Sludge Returned CMAS process was applied to treat the wastewater from electric accessory manufacturing company while this type of wastewater was usually treated by chemical process. This result show that the removal rate of TCOD was about 70-80% regardless of hydraulic retention time, On the contrary, the removal rate of BOD was abtained in a range of 77-92% depending on hydraulic retention time. In order to remove more than 80% of organic materials with the proposed process, the F/M ratio should be maintained below 0.17. In this case, the calculated value of organic removal rate, Km, was calculated to be 1.26 hr$^{-1}$, and the ratio of cell synthesis/total energy was 0.32 and 0.26 for COD and BOD base, respectively. The yield coefficient was calculated to be 0.242 and the half velocity coefficient was 0.3 hr$^{-1}$. The value of endogenous respiration coefficient was 0.02 hr$^{-1}$. The measured effluent BOD concentration, MLSS concentration in aeration tank, oxygen uptake rate, and sludge production were matched relatively well with the calculated values using above coefficients, In order to optimize the dewatering of sludge, the hydraulic retention time was recommended to be 15. 6 hrs. These results indicate that the wastewater from an eletric accessory manufacturing company can be treated safely with a biological process.

  • PDF

Saudi Aramco's Global Expansion Strategy: Evidence from Korea

  • PARK, Young-Eun
    • Journal of Distribution Science
    • /
    • v.18 no.5
    • /
    • pp.71-81
    • /
    • 2020
  • Purpose: This case study illustrates the successful entry of Saudi Aramco in the Korean market and how it grows to become one of the world's largest integrated energy enterprises. Research design, data and methodology: This case investigates diverse secondary sources to examine the entry strategy of Aramco in Korea, such as several interviews including public and anonymous dialogues, periodicals, dispatches (i.e. news articles and magazines), annual reports, industrial reports, and others. Results: The main concern for the international strategic approaching of Saudi Aramco is to enter into Korean market by joint venture with SsangYong Oil (today's S-Oil Corporation) in 1991 and finally, ending by Acquisition of S-Oil in 2015. This acquisition of local No.3 company, S-Oil, in Korea is the successful case in Asian Markets overcoming liability of foreignness. Moreover, Saudi Aramco's global distribution strategy through localization in the Korean market is appropriate given the market conditions, timing, effectiveness, and efficiency by sharing their resources and collaborating. Conclusions: It would be valuable, unique, and real story to analyze global leading company's entry and globalization strategy in overseas market. In addition, this study provides decision-makers with a significant and more strategic implication for the overseas expansion of businesses.

Predicting the Oxidation Amount in the Catalyzed DPF according to the EGR Rate for the Off-road Engine (Off-road 엔진의 EGR율에 따른 촉매코팅 DPF의 자연재생율 예측)

  • Shin, Jaesik;Kang, Jungho;Ha, Hyrengsoo;Jung, Haksup;Pyo, Sukang
    • Journal of the Korean Society of Combustion
    • /
    • v.21 no.3
    • /
    • pp.32-38
    • /
    • 2016
  • This paper aims to predict oxidation amounts of catalyst and heat produced through passive regeneration on DPF according to different EGR rates and loads of off-road engines. Soot oxidation model and parameter assumption model were used for the test. Engine data were measureed with 25%, 50% and 75% of 1600 RPM loads and with 0% and 30% of EGR rates in order to estimate parameters. Oxygen levels calculated on the DPF downstream and oxygen levels measured were compared through all of the experimental conditions for validating the model. Oxidation rates on DPF according to different EGR rates and oxygen levels on the DPF downstream were estimateed successfully, which can be applied for off-road vehicles.

CURRENT STATUS AND PROSPECT FOR PERIODIC SAFETY REVIEW OF AGING NUCLEAR POWER PLANTS IN KOREA

  • Jin, Tae-Eun;Roh, Heui-Young;Kim, Tae-Ryong;Park, Young-Sheop
    • Nuclear Engineering and Technology
    • /
    • v.41 no.4
    • /
    • pp.545-548
    • /
    • 2009
  • Korean utility has utilized a Periodic Safety Review (PSR) that assesses the cumulative effects of plant aging, modifications, operating experience, technical developments, and site characteristics since 2000. In particular, the assessment and management of plant aging is one of the major areas in PSR. It includes identification of critical Systems, Structures, and Components (SSCs) for aging, assessment of aging effects, and implementation of aging management programs. Since the PSR system was introduced based on the atomic energy acts and related laws, PSRs of eight sets for 12 Nuclear Power Plants (NPPs) that have been operating more than 10 years have been completed. PSRs of two sets for 4 NPPs are currently being carried out. The utility has confirmed that domestic NPPs have been operated safely through these PSRs and have implemented the follow-up corrective activities to increase the nuclear safety. In this paper, the status of PSR implementation is discussed and improvement programs to conduct PSR follow-up corrective activities efficiently for NPPs are suggested based on experiences with aging assessments.

Improvement of University Education to Supply Technical Manpower for Plant Engineering Industry in Mechanical Engineering Field (국내 플랜트 엔지니어링 산업의 기계공학 분야 기술인력 수급을 위한 대학교육 개선에 관한 연구)

  • Shim, Hyun-Sun;Kim, Young-Il;Chung, Kwang-Seop
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.11
    • /
    • pp.741-746
    • /
    • 2011
  • In this study, improvements of university education are suggested so that university graduates can work in plant engineering industry without major retraining which is required in plant engineering companies. Before disposition of manpower to the plant engineering site, new recruits are retrained by the company for about 2~3 years, since university education is not sufficient and appropriate to handle plant engineering tasks. It is urgent to integrate into university education practical plant engineering that can be used effectively after graduation. In case of S2 University located in Seoul, it is enough to supplement interdisciplinary program to plant engineering subjects if proper texts are developed. To replace plant engineering education offered by the company with the university education, following measures should be taken. First, basic plant engineering should be taught for 15 hours. Second, education on design and drawings should be reinforced.

Operating Characteristics of the Flow Control Valve for the Radiant Heating System (복사난방용 유량조절 밸브의 작동특성 연구)

  • Pyo, Jin-Soo;Jang, Choon-Soo;Choi, Kwang-Suk;Kim, Youn-Jea
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.552-557
    • /
    • 2007
  • Due to the recent improvement of living standard of residential buildings, the requirements of the thermal comfort and energy saving in heating system have been raised. The radiant floor heating system has been widely used as a residential heating method, which has been modernized to use hot water running into the tubes embedded in the floor structure. The uniform flow distribution is very important factor for a radiant floor heating system such as a blood vessel system in human body. Therefore, it is necessary to investigate the operating characteristics to develop an optimal radiant floor heating system. In this study, numerical analyses were carried out, using a commercial CFD code, FLUENT, to obtain the velocity distribution under steady, three-dimensional, standard k-$\varepsilon$ model and no-slip condition. Results are graphically depicted with various parameters.

  • PDF

The Relationship between Firm-Specific Characteristics and Board of Directors' Diligence in Saudi Arabia

  • ALJAAIDI, Khaled Salmen;BAGAIS, Omer Ali;ADOW, Anass Hamad Elneel
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.1
    • /
    • pp.733-739
    • /
    • 2021
  • This study investigates the relationships of energy firm-level characteristics, namely; firm size, firm leverage, and firm performance with board diligence among companies listed in Saudi Stock Exchange (Tadawul) for the periods ranging from 2012 to 2019. The final sample of this study consists of 32 firm-year observations. A quantitative approach was adopted to test 3 specific hypotheses developed for the board diligence model. Using the Pooled OLS regression, this study finds that firm size and firm performance are negatively associated with board diligence. The results of this study indicate an insignificant association of firm leverage with board diligence. Besides, firm performance is related negatively to board diligence. This indicates that the board of companies with poor performance increases the number of its meetings because of the increased pressure on the board to improve its oversight operations and address the severe performance challenges. The increased number of board meetings observe the daily management of the company, increase the chances for discussions concerning the performance challenges, and come up with solutions faster. The directors are also likely to encounter heightened pressure to appear more engaged during a company's financial distress since lenders require a meeting of the board or with the board.

Status of Czech Low and Intermediate Radioactive Waste Management in the Context of European Development

  • Trtilek, Radek;Havlova, Vaclava;Podlaha, Josef;Svoboda, Karel;Otcovsky, Tomas
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.19 no.1
    • /
    • pp.29-38
    • /
    • 2021
  • The article summarises the status and competence of UJV Rez, a. s. (up to 2012, the Nuclear Research Institute Rez, Czech Republic) in the field of radioactive waste (RAW) management as a company managing of 95% of institutional radioactive wastes in Czech Republic. UJV Rez a. s. has been one of the Czech Republic's key research and engineering institutions in the field of nuclear energy production since 1955. The company processes and conditions prior to storage 95% of so-called institutional RAW and is the principal partner of the state with respect to the research support of the Czech deep geological repository development project. UJV Rez a. s. boasts its own accredited radiochemical analytical test laboratory, unique of its kind in the Czech Republic. Of equal importance is UJV Rez's active participation in a range of international organisations and associations and its involvement in wide range of international projects, and so as European projects. One of them is EU funded project PREDIS: Pre-disposal management of radioactive wastes, that has started at September 2020, focused on the field of low level radioactive waste (LLW) and intermediate level radioactive waste (ILW) pre-disposal.

Investigation of a Hybrid HVDC System with DC Fault Ride-Through and Commutation Failure Mitigation Capability

  • Guo, Chunyi;Zhao, Chengyong;Peng, Maolan;Liu, Wei
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1367-1379
    • /
    • 2015
  • A hybrid HVDC system that is composed of line commutated converter (LCC) at the rectifier side and voltage source converter (VSC) in series with LCC at the inverter side is studied in this paper. The start-up strategy, DC fault ride-through capability, and fault recovery strategy for the hybrid HVDC system are proposed. The steady state and dynamic performances under start-up, AC fault, and DC fault scenarios are analyzed based on a bipolar hybrid HVDC system. Furthermore, the immunity of the LCC inverter in hybrid HVDC to commutation failure is investigated. The simulation results in PSCAD/EMTDC show that the hybrid HVDC system exhibits favorable steady state and dynamic performances, in particular, low susceptibility to commutation failure, excellent DC fault ride-through, and fast fault recovery capability. Results also indicate that the hybrid HVDC system can be a good alternative for large-capacity power transmission over a long distance byoverhead line.