• Title/Summary/Keyword: energy change ratio

Search Result 720, Processing Time 0.025 seconds

Calculating the Sunlight Amount for Buildings Using SAS: A Case Study of Gyeongsan City (그림자 분석 시뮬레이션을 활용한 건축물별 일조량 산정 - 경산시를 사례로)

  • Kim, Do-Ryeong;Kim, Sung-Jae;Han, Soo-Hee;Jo, Myung-Hee
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.1
    • /
    • pp.159-172
    • /
    • 2014
  • As greenhouse gas emissions have been increasing in the world, global warming is being recognized as a cause of the global problems like climate change. This is closely associated the fossil fuels. Thus renewable energy has been brought to the attention of many people as the upcoming alternative energy source to cope with the fossil drain and increased environmental regulations. Especially, the solar energy among renewable energy has drastically increased. In this study, we calculate on daylight ratio about the solar energy for buildings based on digital surface model. The digital surface model was made using the spatial information data. And it was simulated the shadow analysis using SAS. Therefore, it was suitable places to utilize the solar energy in the Gyeongsan city. Consequently, the daylight ratio was considered important factor to select region of the industry of the solar light power generation.

Energy Saving Potentials of Radiant Floor Heating Systems Based on Control Strategies (바닥 복사 난방 시스템의 제어전략에 따른 에너지 사용량 분석)

  • Lee, Joon-Woo;Park, Cheol-Soo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.109-114
    • /
    • 2009
  • The dominant heating system used in Korean residential apartment buildings is a hydronic radiant floor heating system, known as the Ondol system. The most common control strategy applied to this traditional hydronic radiant system is a simple on-off control that intermittently supplies "hot water of a fixed temperature" at a "constant flow rate" to each room. However, the current problems with the aforementioned control are as follows: (1) since the simple on-off control is usually based on a one point measured temperature (a signal from a thermostat installed in a living room) in each dwelling unit, heating energy use for unoccupied rooms as well as a difference in temperatures between spaces (master bedroom, living room, bedroom1, bedroom2) can occur occasionally. (2) the most widely used residential water splitter has static valves, and is thus not able to change the flow rate to each room depending on the space heating load. In other words, the ratio of flow rates to rooms is fixed after construction, resulting in over- or under-heating and an improper use of energy. The aim of this paper is therefore to investigate the differences in the system's performance between control strategies in terms of the flow rate control and sensor location. It is shown that energy savings of control strategies are strongly influenced by occupant schedule.

  • PDF

Physical Properties with Cu/(In+Ga) Ratios of Cu(InGa)$Se_2$ Films (Cu(InGa)$Se_2$ 박막의 Cu/(In+Ga) 조성비에 따른 전기적 물성특성)

  • Kim, S.K.;Lee, J.L.;Kang, K.H.;Yoon, K.H.;Song, J.;Park, I.J.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1584-1586
    • /
    • 2002
  • CuIn$Se_2$ (CIS) and related compounds such as Cu($In_xGa_{1-x})Se_2$(CIGS) have been studied by their potential for use in photovoltaic devices. CIS thin film materials which have high absorption coefficient and wide bandgap, have attracted much attention as an alternative to crystalline and amorphous silicon solar cells currently in use. Cu-rich CIGS film have very low resistivity, due to coexistence of the semimetallic $Cu_{2-x}Se$. In-rich CIGS films show high resistivity, since these films are compensated films without the $Cu_{2-x}Se$ phase. Optical properties of the CIGS films also change in accordance with the resistivity for the Cu/(In+Ga) ratio. The Cu-rich films have different spectra from In-rich films in near infrared wavelengths.

  • PDF

Market Acceptability of the ZEB Certification System for Public Buildings According to the 2025 Roadmap (2025년 의무화 로드맵에 따른 공공시설 제로에너지건축물 인증제도 시장 수용성)

  • Lee, Seung-Min;Kim, Jin-Ho;Shin, Gwang-Su;Kim, Eui-Jong
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.557-566
    • /
    • 2018
  • The ZEB certification system has come into effect since 2018 according to the ZEB road map. From 2020, the public buildings with the total floor area smaller than $3000m^2$ are the target of the certification, and it will be extended to the buildings with up to $5000m^2$ floor area in 2025. However, current mandatory regulations for public office buildings seem already to meet the ZEB certification system planned for 2025. In this work, two buildings belong to $3,000{\sim}5,000m^2$ in total floor area were selected to analyze the possibility of meeting the ZEB certification only by following current obligation regulations. Results showed that the test buildings satisfied the minimum building energy efficiency and energy self-sufficiency rates for the ZEB certification when the mandatory insulation and installation ratio of renewable energy are applied. This can be useful for revising the road map or extending the target buildings of the ZEB certification.

Modification of Carbohydrate Metabolism in Transgenic Potato

  • Heyer, Arnd G.
    • Journal of Plant Biotechnology
    • /
    • v.2 no.1
    • /
    • pp.13-19
    • /
    • 2000
  • Carbohydrates serve three different principal functions in the metabolism of plants. They are the primary products of energy fixation, they are important transport metabolites, and they are deposited as structural or storage compounds. Modification of carbohydrate metabolism therefore covers approaches to modify yield, to change sink/source relationships and thereby alter the ratio of harvestable material, and to improve the quality of crop plants. The scope of this article is to summarize research done at the Max-Planck-Institute related to the first two fields and to present in some detail what we learned, when we established a new carbohydrate storage form in potato.

  • PDF

A study on strain specification and safety degree of connection joints of steel structural member (강구조부재 연결부의 변형특성 및 안전도에 관한 연구)

  • 김경진;김두환
    • Journal of the Korean Professional Engineers Association
    • /
    • v.19 no.4
    • /
    • pp.5-10
    • /
    • 1986
  • On SWS 41 Plates jointed by the F11T M 20 high strength bolts the study on stress behavior and safety degree until rupture in static tensile tests were performed. By these results, in case of no clamping force stress concentration was extremed for strain of about 10% higher ratio. Elastic strain occurred to change of test specimens depth by the load and plastic strain occurred to local minute sleep after elastic strain. compared shear stress with tension stress from the fracture load it was showned lower values than the maximum shear stress theory and stress strain energy theory.

  • PDF

A study on the exhaust gas recirculation in a MILD combustion furnace by using a Venturi nozzle (MILD 이용한 배기가스 재순환에 관한 연구)

  • Ha, Ji Soo;Shim, Sung Hoon
    • Journal of Energy Engineering
    • /
    • v.22 no.4
    • /
    • pp.413-419
    • /
    • 2013
  • The present study used the MILD combustor, which has coaxial cylindrical tube. The outside tube of the MILD combustor corresponds to the exhaust gas passage and the inner side tube is the furnace passage. A numerical analysis was accomplished to elucidate the characteristics of exhaust gas entrainment toward the inner furnace with the changes of venturi nozzle geometrical parameters, nozzle position, nozzle gap between high pressure air nozzle and venturi nozzle, and with the change of high pressure nozzle inlet velocity. The entrainment flow rate for the case with the high pressure air nozzle attached at the exhaust gas wall has relatively small change with the change of nozzle gap. That for the case with the high pressure air nozzle exposed to the exhaust gas has monotonically increase with the change of nozzle gap. The flow rate ratio of entrainment flow rate has considerably increase tendency with relatively lower air inlet velocity, on the other hand, that with relatively higher air inlet velocity could be seen relatively small increase.

The Change of Pillar Strength due to Joint Dip Angles, Total Trace Length and Width-to-Height ratio of a Pillar (절리면의 방향, 절리선 길이 및 광주 형상비가 광주 강도에 미치는 영향 분석)

  • Choi, Ji-won;Lee, Yong-Ki;Song, Jae-Joon
    • Tunnel and Underground Space
    • /
    • v.30 no.3
    • /
    • pp.226-241
    • /
    • 2020
  • The stability of underground mine cavity is closely related with pillar strength. The vulnerability of pillars can be judged and reinforced if the pillar strength is known. The pillar strength is affected by characteristics of discontinuities and shape of a pillar. The change of pillar strength due to a discontinuity passing through the center of a pillar, width-to-height ratio of a pillar and small joints existing within a pillar was analyzed using PFC 3D. The result showed that the pillar strength is influenced by dip angle of a discontinuity and it increases as width-to-height ratio of a pillar increases. The pillar strength decreases as the number of contained joints increases. The relationship between total trace length observable from the pillar surface and the pillar strength was regressed with exponential function. The correlation coefficient of the regression was high enough so that pillar strength can be predicted using total trace length if a joint set exists in a pillar. Lastly, the method to estimate the strength of a pillar that includes two joint sets was proposed if the joint dip angles are 60°, 30°. The method also need total trace lengths of two joint sets.

Experimental study on hysteretic properties of SRC columns with high steel ratio

  • Lu, Xilin;Yin, Xiaowei;Jiang, Huanjun
    • Steel and Composite Structures
    • /
    • v.17 no.3
    • /
    • pp.287-303
    • /
    • 2014
  • 8 steel reinforced concrete (SRC) columns with the encased steel ratio of 13.12% and 15.04% respectively were tested under the test axial load ratio of 0.33-0.80 and the low-frequency cyclic lateral loading. The cross sectional area of composite columns was $500mm{\times}500mm$. The mechanical properties, failure modes and deformabilities were studied. All the specimens produced flexure failure subject to combined axial force, bending moment and shear. Force-displacement hysteretic curves, strain curves of encased steels and rebars were obtained. The interaction behavior of encased steel and concrete were verified. The hysteretic curves of columns were plump in shapes. Hysteresis loops were almost coincident under the same levels of lateral loading, and bearing capacities did not change much, which indicated that the columns had good energy-dissipation performance and seismic capacity. Based on the equilibrium equation, the suggested practical calculation method could accurately predict the flexural strength of SRC columns with cross-shaped section encased steel. The obtained M-N curves of SRC columns can be used as references for further studies.

Effect of Change of Hydrocarbon Reductant on HC-SCR over Fe/ZSM5 Catalyst (탄화수소 환원제 변화가 Fe/ZSM5 촉매를 사용하는 탈질 HC-SCR 반응에 미치는 영향)

  • Kim, Seong-Soo;Kim, Dae-Young;Oh, Se-Yong;Yoo, Seong-Jeon;Park, Jeong-Hwan;Kim, Jin-Gul
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.2
    • /
    • pp.265-273
    • /
    • 2011
  • HC-SCR was conducted using Fe/ZSM5 catalyst coated over 200 cpi cordierite in the conditions of atomspheric pressure and $200^{\circ}C-500^{\circ}C$. Among the tested hydrocarbon reductants, isobutane (i-$C_4H_{10}$) showed the highest de-$NO_x$ yield of 69% at $320^{\circ}C$ with the mole ratio of reductant/$NO_x$ =1.0. De-$NO_x$ yield resulted by the change of alkane reductant was increased as the carbon number of alkane reductant was increased. The order of increase of de-$NO_x$ yield was proportional to the order of decrease of bonding energy between C and H of reductant, where the H abstraction step from alkane molecule could be the rate controlling step of HC-SCR.