• 제목/요약/키워드: energy change ratio

검색결과 720건 처리시간 0.031초

주요국의 2030 온실가스 감축목표에 대한 비교분석과 시사점 (Comparative Analysis of the 2030 GHG Reduction Target for Eleven Major Countries and Its Implications)

  • 오진규
    • 한국기후변화학회지
    • /
    • 제9권4호
    • /
    • pp.357-368
    • /
    • 2018
  • The Paris Agreement, adopted in 2015, requires global mitigation actions by all countries, whether they are developed or developing countries. All member countries prepared and communicated a greenhouse gas reduction target, formally called the Intended Nationally Determined Contribution (INDC). There has been some concern regarding whether the INDCs communicated are sufficient to achieve the emissions reduction needed to hold the increase in global temperature to $2^{\circ}C$ above pre-industrial levels. How to address this emissions gap in an equitable and fair manner remains controversial. Beginning in the year 2023, global stocktaking under the Paris Agreement will be performed by the Conference of the Parties to assess progress towards temperature goals. The present study, based on various composite indicators reflecting equity, fairness, ability and efficiency, analyzed the GHG reduction targets of eleven major countries and the ambitiousness of these targets. Employing share indicators and comparative ratio indicators (resulting in eight composite indicators), this study showed that when share indicators are applied, Korea's appropriate reduction requirement rate is relatively low at 1~2%. However, when comparative ratio indicators are applied, Korea's appropriate reduction requirement rate increases dramatically to 6~11%. In a similar vein, when share indicators are applied, Korea's 2030 target is very ambitious compared to other countries, while the opposite is seen with comparative ratio indicators. This strongly suggests that Korea needs to apply more share indicators than comparative ratio indicators when discussing the equitable and ambitious role of Korea in the climate debate.

이산화탄소 저감형 CSA합성을 통한 수축저감형 시멘트의 특성 평가 (Characterization of Shrinkage Reducing Type Cement Carbon Dioxide-reducible CSA Synthesis)

  • 조용광;남성영;김춘식;조성현;이형우;안지환
    • 에너지공학
    • /
    • 제28권1호
    • /
    • pp.17-21
    • /
    • 2019
  • OPC의 건조수축을 개선시키기 위해 Calcium sulfaluminate(CSA)를 합성하여 수축저감형시멘트를 제조하였다. 본 연구에서는 합성된 CSA를 OPC에 10%, 13% 16%대체하여 응결시간, 압축강도, 길이변화율을 확인하였다. CSA를 함유한 수축저감형시멘트의 경우 Ca-Al-$H_2$계 수화물의 생성 활성화를 통해 응결시간이 크게 단축되는 것을 확인하였다. 압축강도의 경우 7일 강도 이후에는 기존OPC와 동등 수준이나 초기강도는 향상되는 결과를 확인하였다. 길이변화율은 28일 기준으로 -0.075%에서 -0.047%의 길이변화가 발생하였으며, 이로 인해 건조수축 안정성이 향상된 것을 확인하였다.

Study of SF6/Ar plasma based textured glass surface morphology for high haze ratio of ITO films in thin film solar cell

  • Kang, Junyoung;Hussain, Shahzada Qamar;Kim, Sunbo;Park, Hyeongsik;Le, Anh Huy Tuan;Yi, Junsin
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.430.2-430.2
    • /
    • 2016
  • The front transparent conductive oxide (TCO) films in thin fill solar cell should exhibit high transparency, conductivity, good surface morphology and excellent light scattering properties. The light trapping phenomenon is limited due to random surface structure of TCO films. The proper control of surface structure and uniform cauliflower TCO films may be appropriate for efficient light trapping. We report light trapping scheme of ICP-RIE glass texturing by SF6/Ar plasma for high roughness and haze ratio of ITO films. It was observed that the variation of etching time, pattern size and Ar flow ratio during ICP-RIE process were important factors to improve the diffused transmittance and haze ratio of textured glass. The ICP-RIE textured glass showed low etching rates due to the presence of metal elements like Al, B, F and Na. The ITO films deposited on textured glass substrates showed the high RMS roughness and haze ratio in the visible wavelength region. The change in surface morphology showed negligible influence on electrical and structural properties of ITO films. The ITO films with high roughness and haze ratio can be used to improve the performance of thin film solar cells.

  • PDF

공극 내 상대습도, 모세관압력, 표면에너지 변화에 따른 콘크리트 자기수축 (Relation between Autogenous Shrinkage of Concrete and Relative Humidity, Capillary Pressure, Surface Energy in Pore)

  • 이창수;박종혁
    • 콘크리트학회논문집
    • /
    • 제20권2호
    • /
    • pp.131-138
    • /
    • 2008
  • 물-결합재비가 낮은 고성능콘크리트의 자기건조에 의한 습도감소와 수축과의 연관성을 파악하기 위하여 물-결합재비 0.3, 0.4의 배합에 대하여 습도와 변형률을 측정하였다. 그 결과 물-결합재비 0.3의 콘크리트 내부 습도 감소는 약 10%, 수축변형률은 약 $320\times10^{-6}$을 나타내었고, 물-결합재비 0.4의 콘크리트의 경우 4%의 습도 감소와 $120\times10^{-6}$ 수축변형률을 나타내었으며 배합에 상관없이 습도와 변형률은 모두 강한 선형성을 보였다. 콘크리트 내부 습도 변화와 수축변형률의 관계를 보다 구체화하기 위하여 콘크리트 내부 공극을 단일 네트워크로 가정하고 확장 메니스커스 생성가정 하에 공극수에서 발생하는 모세관 압력과 수화조직체에서 발생하는 표면에너지 변화를 습도의 함수로 모델링하여 수축의 구동력으로 작용시킨 결과 실험값과 비교적 일치하는 값을 나타내었다. 이를 근거로 물-결합재비가 낮은 고성능 콘크리트에서 자기건조에 의한 습도감소는 20 nm 이하의 소형공극에서 발생함을 파악할 수 있었으며 따라서 자기수축에 대한 제어 방안은 이러한 소형공극에서의 공극수 표면장력과 포화도에 초점을 맞추어야 함을 확인할 수 있었다.

로터리 킬른용 Low-NOx 다공노즐버너 개발을 위한 수치해석적 연구 (Numerical Study to Develop Low-NOx Multi-nozzle Burner in Rotary Kiln)

  • 안석기;김진호;황민영;김규보;전충환
    • 에너지공학
    • /
    • 제23권4호
    • /
    • pp.130-140
    • /
    • 2014
  • 공정효율 및 배기배출물 개선을 위해 로터리 킬른 버너 개발에 대한 연구는 지속적으로 이루어져 왔다. 본 연구에서는 COG(Coke Oven Gas)를 연료로 사용하는 철광석 소결용 로터리 킬른의 다공노즐버너 개발을 위해 일차공기 노즐 직경, 버너 당량비, 버너 중앙노즐과 주위노즐의 당량비 변화에 따른 화염 및 배기배출 특성에 대한 수치해석 연구를 수행하였다. 일차공기 노즐 직경이 증가함에 따라 각 동일 당량비에서 화염길이는 길어지고 $NO_x$ 배출도 증가하였으며, 버너 당량비가 증가함에 따라 화염길이와 $NO_x$ 배출이 증가하는 결과를 보였다. 버너 중앙노즐의 당량비 변화에 따라 $NO_x$ 배출에는 차이를 보였으며, 화염길이 및 킬른 내부 온도에는 큰 차이가 없었다. 본 연구를 통해 $D_2/D_1$가 1.33, 버너 당량비가 1.25이고 버너 중앙 노즐이 Rich인 조건이 킬른 내부 온도분포 및 $NO_x$ 배출량 기준을 만족하는 적절한 설계조건임을 제시하였다.

DR 시스템에서 모드 변화에 따른 구리필터의 유용성 평가 (Evaluation for the Usefulness of Copper Filters according to Mode Change in Digital Radiography System)

  • 김재겸;김정구
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권1호
    • /
    • pp.39-46
    • /
    • 2021
  • This study confirmed the usefulness of the copper filter according to the mode change by comparing and analyzing the energy change according to the application of the copper filter and the change in effective dose and image quality according to the distance to the subject in the DR(Digital Radiography) system. The average energy increased when the copper filter was applied and the reduction rate by 50% of mAs was increased as the thickness of the copper filter increased according to the application of the 10 kVp rule in AEC mode. The effective dose decreased as the thickness increased when the copper filter was applied in AEC(Automatic Exposure Control) mode and manual mode according to the application of the 10 kVp rule, and the decrease rate decreased with increasing 10 kVp increments. As a result of analyzing the dicom images for AEC mode and manual mode with Image J. the PSNR(Peak Signal to Noise Ratio) values were approximate values of less than 30 dB for each mode and for each copper filter thickness. When the copper filter was applied, the average energy increased, so when the 10 kVp rule was applied, the mAs for each mode could be reduced, and the effective dose could also be reduced. However, as the distance and tube voltage increased, the reduction rate of mAs decreased, and the quality of the image was found to decrease when the copper filter was applied, but there was no difference in quality of the image when the copper filter thickness increased.

불포화 정성토의 체적변화에 대한 연구 (A Study on the Volume Change in Unsaturated Clayey Soil)

  • 장병욱;길상춘
    • 한국농공학회지
    • /
    • 제40권5호
    • /
    • pp.37-42
    • /
    • 1998
  • This study was performed to evaluate the characteristics of volume change is unsaturated clayed soil. The medium-plastic clay was selected and compacted by 50% of Proctor standard compaction energy at 6% higher moisture content than its OMC. A series of isotropic compression tests and triaxial shear tests were performed. The results of the study are summarized as follows. At each matric suction, when the matric suction was increased, the yield stress was increased and slope of volume change was decreased. The more net mean stress was, the less the quantity of volume change was. In shear test, the volumetric strain was much rapidly changed in large matric than in low matric suctions. But the effect of matric suction to volume change disappeared under high net mean stress. At lower deviator stress the more matric suction was, the higher volume change was. But As the matric suction was increasing, the behavior of the unsaturated clayey soil was similar to that of saturated clayey soil. Volume change in the unsaturated clayey soil can be represented as a unique plane in three-dimensional space, which is the axes of net mean stress, matric suction and void ratio.

  • PDF

탄소나노튜브 입자의 길이와 혼합비율이 나노유체의 비등 열전달에 미치는 영향에 대한 연구 (A Study on the Influence of Boiling Heat Transfer of Nanofluid with Particle Length and Mixing Ratio of Carbon Nanotube)

  • 박성식;김우중;김종윤;전용한;김남진
    • 설비공학논문집
    • /
    • 제27권1호
    • /
    • pp.1-7
    • /
    • 2015
  • A boiling heat transfer system is used in a variety of industrial processes and applications, such as refrigeration, power generation, heat exchangers, cooling of high-power electronics components, and cooling of nuclear reactors. The critical heat flux (CHF) is the thermal limit during a boiling heat transfer phase change; at the CHF point, the heat transfer is maximized, followed by a drastic degradation beyond the CHF point. Therefore, Enhancement of CHF is essential for economy and safety of heat transfer system. In this study, the CHF and heat transfer coefficient under the pool-boiling state were tested using multi-wall carbon nanotubes (MWCNTs) CM-95 and CM-100. These two types of multi-wall carbon nanotubes have different sizes but the same thermal conductivity. The results showed that the highest CHF increased for both MWCNTs CM-95 and CM-100 at the volume fraction of 0.001%, and that the CHF-increase ratio for MWCNT CM-100 nanofluid with long particles was higher than that for MWCNT CM-95 nanofluid with short particles. Also, at the volume fraction of 0.001%, the MWCNT CM-100 nanofluid indicated a 5.5% higher CHF-increase ratio as well as an approximately 23.87% higher heat-transfer coefficient increase ratio compared with the MWCNT CM-95 nanofluid.

파력발전용 수조실의 수면 운동 변화에 대한 실험적 연구 (The Experimental Study about Kinetic Change of Water Surface in the Chambers for Wave Energy Converter)

  • ;문병영;이성범;김광중
    • 한국유체기계학회 논문집
    • /
    • 제17권2호
    • /
    • pp.41-47
    • /
    • 2014
  • Experimental results are given for the vertical motion of water in the water chambers for wave energy converter aligned along the wave propagation direction in order to avoid the impulsive wave forces. This paper mainly focuses on the property of the amplitude of the vertical motion of the water surface in the chambers. The amplification has been investigated by dimensionless parameters of wave period to resonance period ratio of the U-shaped oscillation, $T/T_r$, chamber size to wave length ratio, l/L, water depth to wave length ratio, h/L, amplitude of up-down motion of water particles to draft of the front wall ratio, ${\zeta}/D$. It has been shown that l/L should be less than 0.1 and as $T/T_r$ approaches unity the up-down of the water in the chambers is amplified. Also, the structure of the walls which form th water chambers has been examined roughly. It is deduced that the chambers set on both sides of the hull of a single-point moored floating vessel is preferable to those set along a fixed structure such as breakwaters.

도시의 건폐율 및 용적률이 도시기후에 미치는 영향 분석 (Analysis on the Effects of Building Coverage Ratio and Floor Space Index on Urban Climate)

  • 여인애;이정재;윤성환
    • 한국태양에너지학회 논문집
    • /
    • 제29권3호
    • /
    • pp.19-27
    • /
    • 2009
  • In this study, Urban Climate Simulation was performed by 3-Dimensional Urban Canopy Model. The characteristics of urban climate were analyzed combining artificial land coverage, building size, heat production from the air conditioning and topographic conditions as physical variables which affects urban climate characteristics. The results are as follows. (1) The aspects of the urban climatal change is derived to be related to the combination of the building coverage ratio, building height and shading area. According to the building height, the highest temperature was increased by $2.1^{\circ}C$ from 2-story to 5-story building and the absolute humidity by 2.1g/kg maximum and the wind velocity by 1.0m/s was decreased from 2-story to 20-story building. (2) Whole heat generation was influenced by the convective sensible heat at the lower building height and by the artificial heat generation at the higher one over 20-story building influence to some extent of the building coverage ratio. The effect of the altitude is not more considerable than the other variables as below $1^{\circ}C$ of the air temperature. In the last, deriving the combination of building coverage and building height is needed to obtain effectiveness of the urban built environment planning at the point of the urban climate. These simulation results need to be constructed as DB which shows urban quantitative thermal characters by the urban physical structure. These can be quantitative base for suggesting combinations of the building and urban planning features at the point of the desirable urban thermal environment as well as analyzing urban climate phenomenon.