• 제목/요약/키워드: energy balance concept

검색결과 65건 처리시간 0.03초

Reference Spent Fuel and Its Characteristics for a Deep Geological Repository Concept Development

  • Choi, Jong-Won;Ko, Won-Il;Kang, Chul-Hyung
    • Nuclear Engineering and Technology
    • /
    • 제31권6호
    • /
    • pp.23-38
    • /
    • 1999
  • This study addresses the reference spent fuel and its characteristics for developing a geological repository concept. As a disposal capacity of the reference repository system to be developed, spent fuel inventories were projected based on the basis of the Nuclear Energy Plan of the Long-term National Power Program. The reference spent fuel encompassing a variability in characteristics of all existing and future spent fuels of interest was defined. Key parameters in the reference fuel screening processes were the nuclear and mechanical design parameters and the burnup histories for existing spent fuels as of 1996 and for future spent fuels with the more extended burnup the initial enrichment and its expected turnup. The selected reference fuel was characterized in terms of initial enrichment, bumup, dimension, gross weight and age. Also the isotopic composition and the radiological properties are quantitatively identified. This information provided in this study could be used as input for repository system development and performance assessment and applied in fuel material balance evaluation for the various types of back-end fuel cycle studies.

  • PDF

에너지 흐름(기(氣))의 간호학적 접근 (Nursing approach to energy (Qi) flow)

  • 김명자;이명숙
    • 동서간호학연구지
    • /
    • 제3권1호
    • /
    • pp.7-16
    • /
    • 1998
  • This paper reviewed the concept of the energy flow in east and west. The differences in the views of the energy flow between oriental and western thought were compaired according to the ontological point of view. Human body take up energy and material on open system which maintains homeostasis. Human and environment are continuously interacting in a state of co-existence. Human has energy field called "aura" and seven chakra in energy outflow moving came as meridian. Qi is an invisible cosmic energy helping the fundamental human activity and changes. The basic action of Qi is helping the human growth and development, maintain the body temperature and preventing the intrusion of microorganism. In the normal healthy organism, all are maintained in balance and in a continuous circulation of Qi, while illness is the result of the disturbed Qi flow in the aspect of Qi-theory. Although there are differences between oriental and western medicine in approaches to clients, the basic point of view and philosophy have many similarities on fundamental level. An understanding of the basic thought of energy flow and oriental concept of energy flow implies a more comprehensive meaning than the perspective of unitary transformation discussed in modern western thought of energy flow. Now we should avoid narrow view of energy concept and regard energy flow as an integrated concept with Korean culture. Regarding Qi-theory which provides a comprehensive and humanistic and ethical foundation for nursing philisophy through this overview, it is hoped that a contribution will be made to the development of nursing intervention which is suitable to Korean context.

  • PDF

에너지 절약을 위한 "유용성"(Availability)의 열역학적 고찰 (Study on the Thermodynamic concept of "Availability" in Energy Conservation)

  • 손병찬
    • 품질경영학회지
    • /
    • 제14권2호
    • /
    • pp.33-39
    • /
    • 1986
  • This paper is to present basic concepts of availability, irreversibility, dead states, its relationship to other thermodynamic functions, and the history of availability. The balance of availability and effectiveness has also been formulated in order to build basis on which further study and actual application of availability in estimation of available energy are to be thought.

  • PDF

에너지절감을 도모하는 실내 온열환경 제어논리-Adaptive Model (New approaches of Indoor Environmental Control for Energy Saving-Adaptive Model)

  • 송두삼;가토 신스케
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.838-846
    • /
    • 2006
  • The purpose of this study to develop the air-conditioning system that adopts adaptive model as an indoor climate control logic for energy saving. The adaptive model using the ability of human thermal adaptation could be expected to alleviate the indoor set-point temperature compared with the past heat-balance model. Especially, in case of hybrid air-conditioning system coupled with natural ventilation and heating/cooling system, the adaptive model can be describe the thermal comfort of inhabitant who stay at hybrid system controlled buildings with accuracy. In this paper, the concept of adaptive model will be described and the results of a continuous measurement on the actual thermal experiences and behaviors of thermal adaptation for office worker will be reported.

  • PDF

2 자유도 비선형 연성시스템에서 내부공진과 안정성 변화 (Internal Resonance and Stability Change for the Two Degree Nonlinear Coupled System)

  • 김명구;박철희;조종두
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.853-861
    • /
    • 2007
  • To understand the concept of dynamic motion in two degree nonlinear coupled system, free vibration not including damping and excitation is investigated with the concept of nonlinear normal mode. Stability analysis of a coupled system is conducted, and the theoretical analysis performed for the bifurcation phenomenon in the system. Bifurcation point is estimated using harmonic balance method. When the bifurcation occurs, the saddle point is always found on Poincare's map. Nonlinear phenomenon result in amplitude modulation near the saddle point and the internal resonance in the system making continuous interchange of energy. If the bifurcation in the normal mode is local, the motion remains stable for a long time even when the total energy is increased in the system. On the other hand, if the bifurcation is global, the motion in the normal mode disappears into the chaos range as the range becomes gradually large.

  • PDF

압축성 회전유체에서 발생하는 Taylor-Proudman 유동에 대한 점근해석 (An asymptotic analysis of the Taylor-Proudman flow in a rapidly-rotating compressible fluid)

  • 박준상;현재민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.341-344
    • /
    • 2002
  • A matched asymptotic analysis is conducted for a compressible rotating flow in a cylindrical container when a mechanical and/or a thermal disturbance is imposed on the wall. The system Ekman number is assumed to be very small. The conditions for the Taylor-Proudman column in the interior, which were also given in the companion paper Park & Hyun, 2002) by means of the energy balancing analysis, have been re-derived. The concept of the variable, the energy content $e[{\equiv}T+2 {\alpha}^2 {\gamma}{\nu}]$, is reformulated, and its effectiveness in characterizing the energy transport mechanism is delineated. It is seen that, under the condition of the Taylor-Proudman column, numerous admissible theoretical solutions for interior flow exist with an associated wail boundary condition. Some canonical examples are illustrated with comprehensive physical descriptions. The differential heating problem on the top and bottom endwall disks is revisited by using the concept of the energy content. The results are shown to be in line with the previous findings.

  • PDF

압축성 회전 유동에서의 비점성 Taylor-Proudman column 유동 (Taylor-Proudman Column Flows in a Compressible Rotating Fluid)

  • 박준상
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.27-32
    • /
    • 2001
  • A study has been made of the condition to maintaining Taylor-Proudman column flows in a compressible rotating fluid, which is driven by small mechanical and/or thermal perturbations imposing on the container wall in the basic state of isothermal rigid body rotation. The Rossby and system Ekman numbers are assumed to be very small. The Taylor-Proudman column flow can be produced when energy parameter, e, becomes constant on the whole flow region. Energy balance concept, related to energy parameter, and its physical interpretation are given with comprehensive discussions.

  • PDF

음양기혈대사(陰陽氣血代謝)와 비만(肥滿)의 상관관계 (Correlation between Eum, Yang, Ki and Blood Metabolism and Obesity)

  • 신순식
    • 동의생리병리학회지
    • /
    • 제33권1호
    • /
    • pp.1-9
    • /
    • 2019
  • This paper aims to present a model of obesity and leanness based on eum, yang, ki and blood metabolism of Korean medicine. I analyzed the theory of eum, yang, ki and blood metabolism, yang transforming ki and eum forming the body on Korean medicine, and compared them with energy homeostasis by anabolism and catabolism of modern medicine. In the eum and yang theory, the metabolic process of the human body is dominated by synergism and antagonism between eum force and yang force. When the balance of eum and yang collapses, all the pathological actions of the human body appear, and in the eum and yang metabolic process, an imbalance between yang transforming ki and eum forming the body occurs. The function of yang transforming ki is reduced to ki deficiency, and the function of eum forming the body is increased to blood excess. When blood excess and ki deficiency is given, energy intake increases, energy expenditure decreases, overweight and obesity occur. On the contrary, the function of yang transforming ki is increased to ki excess, and the function of eum forming the body is decreased to blood deficiency. When ki excess and blood deficiency is done, energy intake decreases and energy expenditure increases, the body becomes leanness. When the balance of eum, yang, ki and blood metabolism collapses and becomes blood excess and ki deficiency, overweight and obesity occur, and when ki excess and blood deficiency is done, the body becomes leanness. The energy homeostasis of the human body can be explained by eum, yang, ki and blood metabolism of Korean medicine and it contains the concept of anabolism and catabolism of modern medicine.

Active VM Consolidation for Cloud Data Centers under Energy Saving Approach

  • Saxena, Shailesh;Khan, Mohammad Zubair;Singh, Ravendra;Noorwali, Abdulfattah
    • International Journal of Computer Science & Network Security
    • /
    • 제21권11호
    • /
    • pp.345-353
    • /
    • 2021
  • Cloud computing represent a new era of computing that's forms through the combination of service-oriented architecture (SOA), Internet and grid computing with virtualization technology. Virtualization is a concept through which every cloud is enable to provide on-demand services to the users. Most IT service provider adopt cloud based services for their users to meet the high demand of computation, as it is most flexible, reliable and scalable technology. Energy based performance tradeoff become the main challenge in cloud computing, as its acceptance and popularity increases day by day. Cloud data centers required a huge amount of power supply to the virtualization of servers for maintain on- demand high computing. High power demand increase the energy cost of service providers as well as it also harm the environment through the emission of CO2. An optimization of cloud computing based on energy-performance tradeoff is required to obtain the balance between energy saving and QoS (quality of services) policies of cloud. A study about power usage of resources in cloud data centers based on workload assign to them, says that an idle server consume near about 50% of its peak utilization power [1]. Therefore, more number of underutilized servers in any cloud data center is responsible to reduce the energy performance tradeoff. To handle this issue, a lots of research proposed as energy efficient algorithms for minimize the consumption of energy and also maintain the SLA (service level agreement) at a satisfactory level. VM (virtual machine) consolidation is one such technique that ensured about the balance of energy based SLA. In the scope of this paper, we explore reinforcement with fuzzy logic (RFL) for VM consolidation to achieve energy based SLA. In this proposed RFL based active VM consolidation, the primary objective is to manage physical server (PS) nodes in order to avoid over-utilized and under-utilized, and to optimize the placement of VMs. A dynamic threshold (based on RFL) is proposed for over-utilized PS detection. For over-utilized PS, a VM selection policy based on fuzzy logic is proposed, which selects VM for migration to maintain the balance of SLA. Additionally, it incorporate VM placement policy through categorization of non-overutilized servers as- balanced, under-utilized and critical. CloudSim toolkit is used to simulate the proposed work on real-world work load traces of CoMon Project define by PlanetLab. Simulation results shows that the proposed policies is most energy efficient compared to others in terms of reduction in both electricity usage and SLA violation.

간척지 자연순환형 친환경축산단지 도입 타당성 연구 (Feasibility Study on the Development of Environmental Friendly Livestock Complex in the Reclaimed Tideland)

  • 허남효;이승헌;김병기
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.430-433
    • /
    • 2009
  • The development of large-scale environmental friendly livestock complex in the reclaimed tideland is one of different alternatives to increase the competitiveness of internal livestock industry against an international opening markets as DDA and FTA in agricultural field. Recently, it is possible to introduce an environmental friendly livestock complex in the reclaimed tideland by an amendment of the acts for agricultural land. However more studies that are on the basis of nitrogen and phosphorus mass balance need to preserve the agricultural environments as the quality of agricultural water and soil in rural area. In this study, the reference for feasibility study is Whaong reclaimed tideland which located at Whaseong city, Gyeonggi Province, and a basic concept of environmental friendly livestock complex is the production of forage crops with the supply of liquid fertilizer and the production of bioenergy such as biogas by the recycling of pig slurry as a resource. The mass balance of nitrogen based on between forage crops such as maize, barley and liquid fertilizer supplied at the reclaimed tideland, and also it was estimated an economical efficiency as anaerobic digestion plant for treating pig slurry of $100m^3/day$ introduce in an environmental friendly livestock complex.

  • PDF