• Title/Summary/Keyword: end-plate

Search Result 638, Processing Time 0.042 seconds

Shear Strength of Reinforced Glulam-bolt Connection by Glass Fiber Combination (유리섬유 조합에 따른 보강 집성재 볼트접합부의 전단강도 특성)

  • Kim, Keon-Ho;Song, Yo-Jin;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.1
    • /
    • pp.51-57
    • /
    • 2013
  • In order to know the shear performances of a bolted connection in reinforced glulam depending upon the combination of textile glass fiber, a tensile-type shear test was conducted. Textile glass fiber was used as a reinforcement, whose glass fiber arrangement was a plain weaving type or a diagonal cloth type. Reinforced glulam was made up of 5 plies and it was produced by inserting and laminating the plies between laminas depending upon a changed insert position and combination form of textile glass fiber. Tensile-type shear test specimens were a steel plate insert-type and joined at end-distance 7D with bolts whose diameter 12 or 16 mm. In textile glass fiber reinforced glulam, whose volume ratio was 1%, the yield shear strength of a 12 mm bolted connection increased by 10% when a test specimen had reinforced internal layers than when external layers were reinforced. As for textile glass fiber reinforced glulam, whose volume ratio was 2%, the yield shear strength of a 12 mm bolted connection increased significantly by about 22% compared to the bolted connection of non-reinforced glulam, and the yield shear strength of a 16 mm bolted connection was improved by about 20% compared to the bolted connection of non-reinforced glulam.

Influences of Clearcutting of Timber Harvesting on Stream Water Quality (개벌에 의한 수확벌채가 계류수질에 미치는 영향)

  • Park, Jae-Hyeon
    • Korean Journal of Ecology and Environment
    • /
    • v.35 no.1 s.97
    • /
    • pp.45-51
    • /
    • 2002
  • This study was investigated to tile influences of clearcutting of timber harvesting on stream water quality at a natural deciduous forest catchment within the Seoul National University Research Forests in Mt. Baegun, Chunnam province during the periods of 1993 to 2001. Soil chemical ingredients and stream water qualities were monitored at 13 ha clearcutting site, non-treatment site and included in these catchment nearby. After the harvesting first and End years, the levels of total- N, and exchangeable ions ($K^+,\;Na^+,\;Ca^{2+},\;Mg^{2+}$) were decreased the values of before harvesting, and after the harvesting 111th years and eighth years, respectively. But the chemical characteristics of soil were not changed at all. pH of water in the harvesting area was 6.5 in stream water. Among the nutrient, Cd, Pb, Cu, and phosphate were not found, and the level of BOD reached at the level of the domestic use for drinking. Turbidity, odor, taste, $NH_4\;^+-N,\;NO_3\;^--N$, standard plate count, and coliform were also low enough to be used as the domestic use for drinking in the near villagers. Total amount of cation, total amount of anion and total amount of ion in clearcutting site, non- treatment site and included in these catchment nearby were higher than clearcutting site and non- treatment site. But, there was no great difference.

Test Results on the Type of Beam-to-Column Connection using SHN490 Steel (SHN490강종의 보-기둥 접합부 형태에 따른 실험적 연구)

  • Kim, So Yeong;Byeon, Sang Min;Lee, Ho;Shin, Kyung Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.3
    • /
    • pp.311-321
    • /
    • 2015
  • In this study, an experimental study to evaluate the seismic performance of beam-to-column connection for medium and low-rise building was conducted. Five connections using SHN490 steel were made with test variables such as flange welded or bolted, web welded or bolted. Specimen SHN-W-W is web welded and flange welded type. Specimen SHN-W-B is web welded and flange bolted type. Specimen SHN-B-W is web bolted and flange welded type. Specimen SHN-B-B is web bolted and flange bolted type. Specimen SHN-EP is a connection with the end plate to the beam ends. Cyclic loadings was applied at the tip of beam following KBC2009 load protocol. The load vs rotation curves for different connection are shown and final failure mode shapes are summarized. The connections are classified in terms of stiffness and strength as semi-rigid or rigid connection. Energy dissipation capacities for seismic performance evaluation were compared.

The Effects of Mechanical Stress on Alkaline Phosphatase Activity of MC3T3-E1 Cells (기계적 자극이 MC3T3-EI 세포의 Alkaline Phosphatase Activity에 미치는 영향)

  • BAE, Sung-Min;KYUNG, Hee-Moon;SUNG, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.26 no.3
    • /
    • pp.291-299
    • /
    • 1996
  • Orthodontic force is a mechanical stress controlling both of tooth movement and skeletal growth. The mechanical stress stimulate bone cells that may exert some influence on bone remodeling. The purpose of this study was to evaluate the difference in cellular activity depending on mechanical stresses such as compressive and tensile force by determining the alkaline phosphatase(ALP) activity. A clonal osteogenic cell line MC3T3-E1 was seeded into a 24-well plate($2{\times}10^4/well$). At the confluent phase, a continuous compressive hydrostatic pressure($25g/cm^2$, $300g/cm^2$) and continuous tensile hydrostatic pressure($-25g/cm^2$, $-300g/cm^2$) were applied for 4, 6, 10, 14, 18, 20 days respectively by a diaphgragm pump. At the end of the stimulation period, cell layers were prepared for ALP activity assay. The ALP activity of the compressive group increased more than that of the tensile group at same force magnitude, whereas the cells responded to a similar pattern regardless of the type of mechanical stress The ALP activity of the compressive and tensile group turned into the level of the control group as the length of time increased. These results indicated that a mechanical stress may be more effective on cellular activity during active cellular proliferation and differentiation periods. The time to achieve maximum ALP activity was delayed as the mechanical stress increased in both the compressive and the tensile group. Accordingly, the magnitude of the stress rather than the type of mechanical stress may have more influence on cellular activity.

  • PDF

Long Term Efficacy of Posterior Lumbar Interbody Fusion with Standard Cages alone in Lumbar Disc Diseases Combined with Modic Changes

  • Kwon, Young-Min;Chin, Dong-Kyu;Jin, Byung-Ho;Kim, Keun-Su;Cho, Yong-Eun;Kuh, Sung-Uk
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.4
    • /
    • pp.322-327
    • /
    • 2009
  • Objective : Posterior lumbar interbody fusion (PLIF) is considered to have the best theoretical potential in promoting bony fusion of unstable vertebral segments by way of a load sharing effect of the anterior column. This study was undertaken to investigate the efficacy of PLIF with cages in chronic degenerative disc disease with Modic degeneration (changes of vertebral end plate). Methods : A total of 597 patients underwent a PLIF with threaded fusion cages (TFC) from 1993 to 2000. Three-hundred-fifty-one patients, who could be followed for more than 3 years, were enrolled in this study. Patients were grouped into 4 categories according to Modic classification (no degeneration : 259, type 1 : 26, type 2 : 55, type 3 : 11). Clinical and radiographic data were evaluated retrospectively. Results : The clinical success rate according to the Prolo's functional and economic outcome scale was 86% in patients without degeneration and 83% in patients with Modic degeneration. The clinical outcomes in each group were 88% in type 1, 84% in type 2, and 73% in type 3. The bony fusion rate was 97% in patients without degeneration and 83% in patients with Modic degeneration. The bony fusion rate in each group was 81% in type 1, 84% in type 2, and 55% in type 3. The clinical success and fusion rates were significantly lower in patients with type 3 degeneration. Conclusion : The PLIF with TFC has been found to be an effective procedure for lumbar spine fusion. But, the clinical outcome and bony fusion rates were significantly low in the patients with Modic type 3. The authors suggest that PLIF combined with pedicle screw fixation would be the better for them.

Shoes from Pinet to the Present

  • June, Swann
    • Proceedings of the Korea Society of Costume Conference
    • /
    • 2001.08a
    • /
    • pp.11-13
    • /
    • 2001
  • For those unfamiliar with the shoe world, Pinet (1817-1897) was a contemporary of Worth, the great Parisian couturier. So I look at the glamour shoes and the world of haute couture, and indeed the development of the named designer. That is a concept we are all familiar with now. So it is not easy to comprehend the lack of names for the exquisite work before 1850. Straightway I have to say that the number of noted shoe designers is far fewer than famous dress designers, but I will introduce you to some of them, against the background of contemporary shoe fashions. Franc;ois Pinet was born in the provinces (probably Touraine) in 1817, two years after the end of the Napoleonic Wars. His father, an ex-soldier, settled to shoemaking, a comparatively clean and quiet trade. It had a tradition of literacy, interest in politics, and was known as the gentle craft, which attracted intelligent people. We should presume father would be helped by the family. It was usual for a child to begin by the age of 5-6, tying knots, sweeping up, running errands and gradually learning the job. His mother died 1827, and father 1830 when he was 13, and at the time when exports of French shoes were flooding world markets. He went to live with a master shoemaker, was not well treated, and three years later set out on the tour-de- France. He worked with masters in Tours and Nantes, where he was received as Compagnon Cordonnier Bottier du Devoir as Tourangeau-Ia rose dAmour (a name to prove most appropriate). He went on to Bordeaux, where at 19 he became president of the local branch. In 1841 he went to Paris, and in 1848, revolution year, as delegate for his corporation, he managed to persuade them not to go on strike. By now the shoemakers either ran or worked for huge warehouses, and boots had replaced shoes as the main fashion. In 1855 Pinet at the age of 38 set up his own factory, as the first machines (for sewing just the uppers) were appearing. In 1863 he moved to new ateliers and shop at Rue ParadisPoissoniere 44, employing 120 people on the premises and 700 outworkers. The English Womans Domestic Magazine in 1867 records changes in the boots: the soles are now wider, so that it is no longer necessary to walk on the uppers. There is interest in eastern Europe, the Polonaise boots with rosette of cord and tassels and Bottines Hongroises withtwo rows of buttons, much ornamented. It comments on short dresses, and recommends that the chaussure should correspond to the rest of the toilet. This could already be seen in Pinets boots: tassels and superb flower embroidery on the higher bootleg, which he showed in the Paris Exposition that year. I think his more slender and elegant Pinet heel was also patented then or 1868. I found little evidence for colour-matching: an English fashion plate of 1860 shows emerald green boots with a violetcoloured dress.

  • PDF

A Clinical Study of Facial Paralysis (안명신경 손상 환자의 임상적 고찰)

  • Huh, Choon-Bok;Suh, Tae-Soo
    • Journal of Korean Physical Therapy Science
    • /
    • v.5 no.3
    • /
    • pp.643-650
    • /
    • 1998
  • Facial nerve is subject to injury at any point in the course from the cerebral cortex to the motor end plate in the face, so many etiologic varieties of facial paralysis may be encountered, including trauma, viral infection and the idiopathic. Authors have studied 39 cases of facial paralysis which had experienced of treatment in our department from March, 1996 to March, 1997 at Dong San Medical Center. The results obtained are as follows : 1) The highest age incidence showed 10 cases(24.6%) in 3rd decade 2) Among the total of 39 cases, male were 21 cases(53.8%) and female were 18cases(46.2%). 3) At the involved side, left side were 19 cases(48.7%) and right side were 18 cases(46.2%). 4) The causes of facial paralysis were; idiopathic (Bell's palsy) in 19 cases(48.7%) infectious in 6 cases(15.4%) neoplastic in 6 cases(15.4%) traumatic in 5 cases(12.9%) metabolic in 2 cases(5.1%) congenital in 1 cases(2.6%) 5) In time interval between onset of symptom and treated initial date, 26 cases(66.7%) in below 10 days and 8 cases(20.5%) in 11-20 days 6) Correlation of recovery rate according to the treated duration did not differ significantly 7)Result after treatment were satisfactory

  • PDF

Effects of spinal stabilization training on Chronic Low Back Pain in Private Guard and Security (척추안정화 운동이 민간 경호.경비원들의 허리통증에 미치는 영향)

  • Kim, Seong-Ho;Lee, Wan-Hee
    • Korean Security Journal
    • /
    • no.20
    • /
    • pp.71-93
    • /
    • 2009
  • The purpose of this study was to evaluate the effects of using spinal stabilization exercise for the improvement of atrophy of the multifidus and psoas major, of pain and disability with chronic low back pain in private guard and security. For 42 patients diagnosed with CLBP, and divided into spinal stabilization exercise group(SSEG) and general spinal strengthening exercise group(GSSEG). Each exercise was conducted for 10 weeks. Pain and disability were measured before and after exercise using the Visual analogue scale(VAS) and the Oswestry disability index(ODI). Cross section area(CSA) of both the left and right multifidus and the psoas major at the upper end plate of L4 were measured before and after exercise using computed tomography(CT). After 10 weeks of exercise, the both group's pain and lumbar disability were significantly decreased(p<0.01). Also there was significant difference in both group(p<0.05). In addition, the CSA of the left and right multifidus and posas major were significantly increased as compared to the pre-exercise in both group(p<0.01). But SSEG's cross sectional areas of multifidus was more significantly increase than GSSEG(p<0.05). In summary, Spinal stabilization exercise is more effective in improving atrophy in private guard and security patients, in reducing patients' pain and disability. It is an effective treatment to aid rehabilitation in these cases.

  • PDF

Changes in Quality Characteristics of Vacuum-Shrink Packaged Bierschinken after Stuffing in Fibrous Casing during Chilled Storage (화이브러스 케이싱에 충전 후 진공 수축 포장한 비어슁켄의 냉장 중 품질 특성 변화)

  • Lee Jung-Pyo;Lee Keun-Taik
    • Food Science of Animal Resources
    • /
    • v.25 no.2
    • /
    • pp.121-126
    • /
    • 2005
  • The changes in quality characteristics and shelf-life of vacuum-shrink packaged Bierschinken after stuffing in fibrous casing and stored at 5 and $10^{\circ}C$ were investigated The total aerobic plate count (APC) of Bierschinken was initially <2.00 $log_{10}CFU/cm^2$, however increased gradually over storage period The APCs of Bierschinken maintained at the level of 4.86 and 5.13 $log_{10}CFU/cm^2$ after 35 days at 5 and $10^{\circ}C$, respectively. pH tended to decrease with the extension of storage period The values of TBA and VBN tended to increase with storage time, of which trend was pronounced at $10^{\circ}C$ rather than at $5^{\circ}C$. According to the sensory evaluation, Bierschinken had the marketing value till 28 days irrespective of storage temperature. The shelf-life of Bierschinken tested might be preferentially restricted by the occurrence of off-odor and off-flavor at the end of storage period.

A Study on CFD Analysis to Investigate the Effects of Different Feed Rate into the High Temperature H2SO4 Transferring Pump at Fixed Frequency

  • Choi, Jung-Sik;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.3
    • /
    • pp.304-311
    • /
    • 2014
  • In this study, to apply hydrogen energy to ship engine and to generate effective hydrogen production, we investigated the effects of high temperature $H_2SO_4$ feed rate and cooling water rate to pump parts with fixed frequency needed to reciprocate motion and a simulation was conducted at each condition. In the fixed frequency and cooling water inlet flow rate of 0.5 Hz and 3.9 kg/s, we changed the high temperature $H_2SO_4$ flow rate to 47.46 kg/s (it is 105 % of 45.2 kg/s), 49.72 kg/s (110 %), and 51.98 kg/s (115 %). Also, at 0.5 Hz and 45.2 kg/s of frequency and high temperature $H_2SO_4$ flow, the thermal hydraulic analysis was performed at the condition of 95 % (3.705 kg/s), 90 % (3.51 kg/s), and 85 % (3.315 kg/s). In overall simulation cases, the physical properties of materials are more influential to the temperature increase in the pump part rather than the changes on the feed rate of high temperature $H_2SO_4$ and cooling water. A continuous operation of pump was also capable even if the excess feed of high temperature $H_2SO_4$ of about 15 % or the less feed of cooling water of about 15 % were performed, respectively. When the increasing feed of high temperature $H_2SO_4$ of up to 5 %, 10 %, and 15 % were compared with base flow (45.2 kg/s), the deviation of time period rose to a certain temperature and ranged from 0 to 4.5 s in the same position (same material). In case of cooling water, the deviation of time period rose to a certain temperature and ranged from 0 to 5.9 s according to the decreasing feed changes of cooling water at 5 %, 10 %, and 15 % compared to a base flow (3.9 kg/s). Finally, the additional researches related to the two different materials (Teflon and STS for Pitch and End-plate), which are concerned about the effects of temperature changes to the parts contacting different materials, are needed, and we have a plan to conduct a follow-up study.