유효광합성량 (PAR)의 증가에 따른 BVOCs 배출 특성 변화 (Variations of BVOCs Emission Characteristics according to Increasing PAR)

  • 손윤석;황윤서;성주한;김조천
    • 한국대기환경학회지
    • /
    • 제28권1호
    • /
    • pp.77-85
    • /
    • 2012
  • In this study, emission rates (ER) of biogenic volatile organic compounds (BVOCs) were measured by varying levels of photosynthetically active radiation (PAR). An appropriate plan for ozone reduction according to increasing ecology area ratio in future metropolitan areas was suggested. Several trees were selected as representative tree species in urban areas. Emission rates and composition ratios of monoterpene and isoprene emitted from these trees were estimated and compared. As a result, it was found that emission rates of BVOCs were considerably different depending on tree species. Especially, BVOCs emitted from Platanus orientalis and Quercus mongolica could significantly affect ozone increase in the metropolitan area, because the emission rates were several thousands to ten thousand times higher than those emitted from Zelkova serrata and Prunus serrulata. Furthermore, it was observed that emission rates of BVOCs by species increased maximum up to 10 times when PAR, which has close relations with temperature, rose. It was concluded that tree species such as Zelkova serrata et al., was appropriate for metropolitan areas since the species has low ozone potential and good landscape. Suppose this type of trees are planted on purpose in the urban areas, better ambient air quality will be promised in the future.

Measurements of 50 Non-polar Organic Compounds Including Polycyclic Aromatic Hydrocarbons, n-Alkanes and Phthalate Esters in Fine Particulate Matter (PM2.5) in an Industrial Area of Chiba Prefecture, Japan

  • Ichikawa, Yujiro;Watanabe, Takehisa;Horimoto, Yasuhide;Ishii, Katsumi;Naito, Suekazu
    • Asian Journal of Atmospheric Environment
    • /
    • 제12권3호
    • /
    • pp.274-288
    • /
    • 2018
  • Quantitative data of 50 non-polar organic compounds constituting $PM_{2.5}$ were continuously collected and analyzed from June 2016 to October 2017 (approximately 17 months) at Ichihara, one of the largest industrial areas in Japan. Target non-polar organic compounds including 21 species of polycyclic aromatic hydrocarbons (PAHs), 24 species of n-alkanes and 5 species of phthalate esters(PAEs) were simultaneously measured by gas chromatography/mass spectrometry. Basically, the average concentrations of the total PAHs, n-alkanes and PAEs in each season remained nearly level, and seasonal variations were little throughout the study period. These results suggest that the emission sources, which are not influenced by the seasons, are the dominant inputs for the target organic compounds. Diagnostic ratios of PAHs, assessment of n-alkane homologue distributions, carbon preference index, and the contribution of wax n-alkanes from plants were used to estimate source apportionments. These results indicate that anthropogenic sources were the main contributor for most PAHs and n-alkanes throughout the study period. The concentrations of PAEs selected in this study were low because emission amounts of these chemicals were little within the source areas of the sampling site. To our knowledge, this study is the first attempt to simultaneously measure a high number of non-polar organic compounds in $PM_{2.5}$ collected from the ambient air of Japan, and the resultant data will provide valuable data and information for environmental researchers.

합판 제조용 목재 건조공정에서의 휘발성 유기화합물(VOCs) 배출특성 (Emission Characteristics of VOCs in Drying Process for Plywood Manufacturing)

  • 장정국;김미란
    • 한국환경과학회지
    • /
    • 제17권12호
    • /
    • pp.1381-1390
    • /
    • 2008
  • Emission characteristics of volatile organic compounds (VOCs) were investigated in the flue gas emitted from wood drying process for plywood manufacturing. The moisture content of raw timber was average 48%, and its density was $831.55kg/m^3$. But the moisture content of dried wood is needed less than around 10%, thus the moisture contents of flue gas should be remarkably high(about 18.2 V/V%). Therefore, the vapor in flue gas is equivalent to 320 ton-vapor/day when 1100 ton-wood/day is treated in the wood drying process. The temperature of flue gas ranges from $140^{\circ}C\;to\;150^{\circ}C$ in each dryer stack with exception of the input site of wood(about $110^{\circ}C$). The velocity of flue gas in each stack ranges from 1.7 to 9.7m/sec. In order to assess the concentrations and attribution rate of odorous compounds, it was analyzed about 40 VOCs in the flue gases. It was found that the major odorous compounds were 8 compounds, and the concentrations of major VOCs(ppm) were as follows; benzene: $0.054{\sim}0.052$, toluene: $1.011{\sim}2.547$, ethylbenzene: $0.472{\sim}2.023$, m,p-xylene: $0.504{\sim}3.245$, styrene: $0.015{\sim}0.148$, o-xylene : $0.271{\sim}1.097$, ethanol: $11.2{\sim}32.5$, ${\alpha}$-pinene: $0.908{\sim}10.578$, ${\beta}$-pinene: $0.982{\sim}14.278$. The attribution rate of terpenes (${\alpha}$-pinene, ${\beta}$-pinene) was about 60.56%, and that of aromatics and alcohols was about 22.77%, and 16.67%, respectively. It is suggested that the adequate control device should be used to control both the water soluble and non-soluble compounds because both compounds were mixed in flue gas.

Air Pollutant Emission Factors from Composite Wood Products Manufacturing in Korea

  • Lee, Eun-Jung;Jung, Dong-Il;Kim, Dai-Gon;Lee, Sue-Been;Kang, Kyoung-Hee;Hong, Ji-Hyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제23권E2호
    • /
    • pp.57-65
    • /
    • 2007
  • In Korea, there is a general lack of information available on air emissions from industry. The reasons for this include the lack of regulatory requirements for emission monitoring, limited information on specific industries, and difficulties in monitoring certain sources. This paper presents the first detailed air pollutant emission factors from composite wood product manufacturing in Korea. This study introduced emission factors for wood-based panels such as plywood, particle board (PB), and medium density fiberboard (MDF). The emission factors of particulate matters (PM) and hazardous air pollutants (HAPs) from MDF were higher than that from other wood products. The concentration of total volatile organic compounds (TVOCs) for hot press from wood-based panels was higher than drying or gluing processes. Emissions data from NPIP were compared to the data from the suggested emission factors in this study and the US EPA's. The data from our emission factors were closer to the observed results than the data using the US EPA's emission factor.

도파민과 세로토닌 운반체 및 수용체 영상을 위한 방사성리간드 (Radioligands for Imaging Dopamine and Serotonin Receptors and Transporters)

  • 지대윤
    • 대한핵의학회지
    • /
    • 제34권3호
    • /
    • pp.159-168
    • /
    • 2000
  • In the 1980s, techniques to image the human subjects in a three-dimensional direction were developed. Two major techniques are SPECT (Single Photon Emission Computed Tomography) and PET (Positron Emission Tomography) which allow the detector to detect a single photon or annihilation photons emitted from the subjects injected with radiopharmaceuticals. Since the latter two techniques can measure the density of receptors, enzymes and transporters in living human, it may be very important project to develop selective methods of labeling with radionuclides and to develop new radiopharmaceuticals. There has been a considerable interest in developing new compounds which specifically bind to dopamine and serotonin receptor and transporters, and it will be thus very useful to label those compounds with radionuclides in order to gain a better understanding in biochemical and pharmacological interactions in living human. This review mentions the characteristics of radioligands for the imaging of dopamine and serotonin receptors and transporters. Although significant progress has been achieved in the development of new PET and SPECT ligands for in vivo imaging of those receptors and transporters, there are continuous needs of new diagnostic radioligands.

  • PDF

숯 제조시설의 악취물질 배출특성과 관리실태 조사 연구 (Evaluation of Malodor Release and Control Devices in Charcoal Manufacturing Facility)

  • 정주영;서병량;김재혁;진성민;정종수
    • 한국환경과학회지
    • /
    • 제21권7호
    • /
    • pp.883-890
    • /
    • 2012
  • Emission characteristics of gaseous odor compounds emitted from the charcoal manufacturing process were investigated, and evaluated the odor removal efficiency of odor control devices. It was found that the measured odor dilution ratio of emission gases ranged from 10,000 to 44,814, which exceed largely the emission standard in the stack. Methylmercaptan, trimethylamine, hydrogen sulfide, acetaldehyde were turned out as major odor compounds of the charcoal manufacturing process. It was revealed that the odor removal ratio of odor control devices were very low due to the its improper maintenance and wrong design.

자동차에서 배출되는 가스상 유해대기오염물질 (HAPs) 배출량 추정 (Estimation of Gaseous Hazardous Air Pollutants Emission from Vehicles)

  • 김정;장영기;최상진;김정수;서충열;손지환
    • 한국대기환경학회지
    • /
    • 제29권1호
    • /
    • pp.1-9
    • /
    • 2013
  • Hazardous Air Pollutants (HAPs) are difficult to measure, analyze and assess for risk because of low ambient concentrations and varieties. Types of HAPs are Volatile organic compounds (VOCs), Polycyclic aromatic hydrocarbon (PAHs) and Aldehydes. HAP emissions from vehicles are a contributor to serious adverse health effects in urban areas. In this study, hazardous air pollutant emissions from road transport vehicles by Non-methane volatile organic compounds (NMVOC) weight fraction and PAHs emission factors are estimated in 2008. The top-five-most hazardous air pollutant emissions were estimated to toluene 864.3 ton/yr, acrolein 690.6 ton/yr, acetaldehyde 554.5 ton/yr, formaldehyde 498.7 ton/yr, propionaldehyde 421.6 ton/yr in 2008. The results for a cancer and non-cancer risk assessment of HAPs emissions show that the major cancer driver is formaldehyde and the non-cancer driver is acrolein.

완주지역의 VOCs 배출특성에 따른 공단지역과 일반지역의 기여도 분석 (VOCs Emission Characteristics and Mass Contribution Analysis at Wanju Industrial Area)

  • 김득수;양고수;박비오
    • 한국대기환경학회지
    • /
    • 제24권5호
    • /
    • pp.562-573
    • /
    • 2008
  • Concentrations of volatile organic compounds (VOCs) measured from the local industrial sources in Wanju industrial complex during June $2007{\sim}January$ 2008. The samples were collected from the primary sources (6 emission points) in 4 major factories in Wanju industrial complex as well as two general sources in Wanju County to elucidate the abundances of speciated VOCs and their spacial and temporal distributions depending on source bases. Industrial sources are as follows; fabricated metal manufacture, motor vehicle manufacture, rubber and plastic manufacture, and chemical manufacture factories. Two general source samples were collected from gasoline gas station and dry cleaning shop in urban area. In order to understand the near source influence at receptor, samples from the two receptor sites (one is at center of the industrial complex and the other site is at distance residential area downwind from the center) were collected with sample canister, and analyzed by using GC/MSD. The concentrations from different sources were compared and discussed. The mass contributions of the speciated VOCs to total VOCs measured from industrial sources and ambient ai r at two receptors were presented and discussed.