• Title/Summary/Keyword: emg

Search Result 1,880, Processing Time 0.025 seconds

Intraoperative Neurophysiological Monitoring in Cerebello Pontine Angle Tumor

  • Park, Sang-Ku
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.46 no.1
    • /
    • pp.38-45
    • /
    • 2014
  • Intraoperative Neurophysiological Monitoring (INM) inspection has a very important role. While preserving the patient's neurological function be sure to safe surgery, neurological examination should thank. Cerebello pontine angle tumor surgery, especially in the nervous system is more important to the meaning of INM. In cochlear nerve, facial nerve, trigeminal nerve, which are intricate brain surgery, doctors are only human eye and brain to the brain that it is virtually impossible to distinguish the nervous system. They receives a lot of help from INM. In this paper, we examined six kinds broadly. First, the methods of spontaneous EMG and Free-running EMG, which can instantly detect a damage inflicted on a nerve during surgery. Second, methods of triggered EMG and direct nerve electrical stimulation, which directly stimulate a nerve using electricity to distinguish between nerves and brain tumors. Third, the method of knowing a more accurate neurologic status by informing neurological surgeons about Free-running EMG wave forms that are segmetalized into four. Fourth, three ways of knowing when a patient will be awaken from intraoperative anesthesia, which happens due to a weak anesthetic. Fifth, a method of understanding the structures of a brain tumor and a facial nerve as five dividend segments. Sixth, comparisons between cases normal facial nerve recovery and occurrence of a facial nerve paralysis during the postoperative course.

Effect of Electromyographic Biofeedback Training on the Muscle Activities of Unilateral Facial Palsy (근전도 바이오피드백을 이용한 훈련이 안면신경마비 환자의 운동학습에 미치는 영향)

  • Kim, Won-Ho;Park, Eun-Young;Chang, Ki-Yeon;Lee, Young-Jung
    • Physical Therapy Korea
    • /
    • v.9 no.3
    • /
    • pp.101-111
    • /
    • 2002
  • The purpose of this study was to determine EMG biofeedback training effect on the muscle activities in 3 unilateral facial palsy patients along with multiple baseline design across subjects. The auditory feedback about facial muscles (orbicularis oris, orbicularis oculi, frontalis) was provided with each patient during facial exercise training. Electromyographic (EMG) activity during maximal voluntary contraction and maximal compound muscle action potential (CMAP) amplitude elected by supramaximal electrical stimulation on facial nerve of facial muscles were measured pre- and post- EMG biofeedback training to evaluate motor learning. EMG activity during maximal voluntary contraction was increased after EMG biofeedback training and CMAP amplitude elected by supramaximal electrical stimulation was not changed in all subjects. The results indicate that EMG biofeedback training is useful method to improve motor learning of facial excercise training in unilateral facial palsy patients.

  • PDF

Difference in sEMG on lower extremity during leg press exercise with whole body vibration with various amplitude and frequency (수직 진동을 동반한 Leg Press 운동 시 진동 크기와 주파수에 따른 하지 근육의 근전도 차이 분석)

  • Choi, Jin-Seung;Kim, Yong-Jun;Kang, Dong-Won;Mun, Kyung-Ryoul;Tack, Gye-Rae
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1492-1495
    • /
    • 2008
  • As a prerequisite of developing muscle biofeedback system which can simulate analogous isokinetic exercise, the purpose of this study was to study the effects of frequency and amplitude of whole-body vibration on the difference in sEMG on lower extremities during leg press exercise with/without vibration. The amplitude of vibration was set to 20, 50, 80 and the frequency of vibration was set to 10, 20, 30, and 50 Hz. EMG were measured at Vastus lateralis muscle and Vastus medialis muscle. MP100 EMG module(BIOPAC system Inc., USA) was used for EMG measurement. The result showed that the combination of frequency of 30Hz and amplitude of 50 had more activated EMG than other combination with relatively small work load (30kg). It is necessary to experiment the frequency between 20 and 40Hz in detail, and to normalize sEMG using maximal voluntary contraction (MVC).

  • PDF

Masseteric EMG Signal Modeling Including Silent Period After Mechanical Stimulation (기계적 자극에 대한 휴지기를 포함한 교근의 근전도 신호 모델링)

  • Kim, Duck-Young;Lee, Sang-Hoon;Lee, Seung-Woo;Kim, Sung-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.11
    • /
    • pp.541-549
    • /
    • 2001
  • The term 'silent period(SP)' refers to a transitory, relative or absolute decrease electromyography(EMG) activity, evoked in the midst of an otherwise sustained contraction. Masseteric SP is elicited by a tap on the chin during isometric contraction of masseter muscle. In this paper, a new EMG signal generation model including SP in masseter muscle is proposed. This work is based on the anatomical structure of trigeminal nerve system that related on temporomandibular joint(TMJ) dysfunction. And it was verified by comparing the real EMG signals including SP in masseter muscle to the simulated signals by the proposed model. Through this studies, it was shown that SP has relation to variable neurophysiological phenomena. A proposed model is based on the control system theory and DSP(Digital Signal Processing) theory, and was simulated using MATLAB simulink. As a result, the proposed SP model generated EMG signals which are similar to real EMG signal including normal SP and an abnormal extended SP. This model can be applied to the diagnosis of TMJ dysfunction and can effectively explain the origin of extended SP.

  • PDF

Improvements of Multi-features Extraction for EMG for Estimating Wrist Movements (근전도 신호기반 손목 움직임의 추정을 위한 다중 특징점 추출 기법 알고리즘)

  • Kim, Seo-Jun;Jeong, Eui-Chul;Lee, Sang-Min;Song, Young-Rok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.5
    • /
    • pp.757-762
    • /
    • 2012
  • In this paper, the multi feature extraction algorithm for estimation of wrist movements based on Electromyogram(EMG) is proposed. For the extraction of precise features from the EMG signals, the difference absolute mean value(DAMV), the mean absolute value(MAV), the root mean square(RMS) and the difference absolute standard deviation value(DASDV) to consider amplitude characteristic of EMG signals are used. We figure out a more accurate feature-set by combination of two features out of these, because of multi feature extraction algorithm is more precise than single feature method. Also, for the motion classification based on EMG, the linear discriminant analysis(LDA), the quadratic discriminant analysis(QDA) and k-nearest neighbor(k-NN) are used. We implemented a test targeting twenty adult male to identify the accuracy of EMG pattern classification of wrist movements such as up, down, right, left and rest. As a result of our study, the LDA, QDA and k-NN classification method using feature-set with MAV and DASDV showed respectively 87.59%, 89.06%, 91.75% accuracy.

Influences of Shoe Heel Height on Isometric Shoulder Abductor Strength and EMG Activities of Selected Shoulder Muscles (신발 뒤굽 높이가 등척성 어깨 외전 근력과 근전도 활동에 미치는 영향)

  • Oh, Duck-Won
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.2
    • /
    • pp.9-16
    • /
    • 2015
  • PURPOSE: The objective of this study was to identify the effects of shoulder abduction strength and EMG activities of the selected scapular and shoulder muscles during isometric shoulder abduction. METHODS: Thirty-four healthy young females were recruited for this study. Surface EMG equipment with inline force sensor was used to determine the shoulder abductor strength and the activity of the serratus anterior (SA), upper trapezius (UT), lower trapezius (LT), and middle deltoid (MD) during three shoe heel height conditions: (1) barefoot, (2) 3-cm shoe heel height, and (3) 7-cm shoe heel height. RESULTS: Isometric shoulder strength showed statistically significant difference among the conditions (p<0.05), and post-hoc test showed lower strength during the 7-cm condition ($49.98{\pm}17.56kg$) than during the barefoot ($44.97{\pm}20.15kg$) and 3-cm conditions ($36.59{\pm}17.07kg$). Furthermore, EMG activities of the SA, UT, and MD appeared to be statistically significantly different among the conditions, with lower values in the 7-cm condition compared to the barefoot condition (p<0.05). EMG ratios (MD/UT and SA/UT) were lower during the 7-cm condition than during the barefoot condition (p<0.05). CONCLUSION: These findings suggest that isometric shoulder abduction strength and EMG activities of scapular and shoulder muscles may be adversely changed with increasing shoe heel height.

Development of EMG-Triggered Functional Electrical Stimulation Device for Upper Extremity Bilateral Movement Training in Stroke Patients: Feasibility and Pilot study

  • Song, Changho;Seo, Dong-kwon
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.3
    • /
    • pp.374-378
    • /
    • 2021
  • Objective: Bilateral movement training is an effective method for upper extremity rehabilitation of stroke. An approach to induce bilateral movement through functional electrical stimulation is attempted. The purpose of this study is to develop an EMG-triggered functional electrical stimulation device for upper extremity bilateral movement training in stroke patients and test its feasibility. Design: Feasibility and Pilot study design. Methods: We assessed muscle activation and kinematic data of the affected and unaffected upper extremities of a stroke patient during wrist flexion and extension with and without the device. Wireless EMG was used to evaluate muscle activity, and 12 3D infrared cameras were used to evaluate kinematic data. Results: We developed an EMG-triggered functional electrical stimulation device to enable bilateral arm training in stroke patients. A system for controlling functional electrical stimulation with signals received through a 2-channel EMG sensor was developed. The device consists of an EMG sensing unit, a functional electrical stimulation unit, and a control unit. There was asymmetry of movement between the two sides during wrist flexion and extension. With the device, the asymmetry was lowest at 60% of the threshold of the unaffected side. Conclusions: In this study, we developed an EMG-triggered FES device, and the pilot study result showed that the device reduces asymmetry.

Design of Device for Rotator Cuff Training and Its Experimental Validation with sEMG (회전근개 훈련용 기기 설계와 sEMG를 활용한 실험적 검증)

  • Byun, Sangkyu;Kim, Jaehoon;Chung, Jiyong;Kim, Heeyoung;Shin, Sungwook;Lee, Eunghyuk
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.8
    • /
    • pp.1035-1043
    • /
    • 2021
  • The shoulder is less stable than other joints, making it easier to onset of various shoulder disorders. In addition, limited range of motion and pain in the shoulder due to shoulder disorders restricts daily life and social activities. The problem with exercise therapy can be reduced in exercise effect by causing boredom through simple repetition of motion, thus reducing the patient's willingness to participate. Therefore, this paper aims to provide a treatment method that can induce active participation of patients by developing devices capable of passive, active, and resistance exercise and serious game contents using them. Furthermore, sEMG was used to verify whether the rotational exercise in the horizontal and vertical using serious game contents helps the shoulder movement actually. The measured sEMG signal was classified as 5 phases according to the angle of rotation and calculated the mean integrated EMG. The mean integrated EMG for the experimental results was higher in all phases when rotational was performed compared to those when both horizontal and vertical rotational exercise remained initial posture, indicating an increase in muscle activity.

Evaluation of Treatment Outcomes in Oromandibular Dystonia Using Surface Electromyography: A Case Series

  • Im, Yeong-Gwan;Kim, Jae-Hyung;Kim, Byung-Gook
    • Journal of Oral Medicine and Pain
    • /
    • v.46 no.4
    • /
    • pp.143-149
    • /
    • 2021
  • Purpose: Oromandibular dystonia is a neurological disorder that affects the jaw and lower face muscles, often resulting in abnormal repetitive movement of the jaw and perioral structures. The purpose of this study was to assess the effectiveness of surface electromyography (EMG) in evaluating the treatment outcome of oromandibular dystonia. Methods: Based on a retrospective review of medical records, we analyzed the data of four patients who received medication or botulinum toxin injection, as well as surface EMG of the jaw muscles before and after treatment. We assessed the patients' clinical characteristics and the results of surface EMG before and after treatment. Results: The case series included one female and three males, and the age range was 65-78 years. Based on the clinical features, two subjects were classified as jaw deviation and the remaining two were as jaw closing. Dystonic patterns revealed by surface EMG varied, including phasic, tonic, and mixed contraction patterns. EMG amplitude after treatment was lower than pre-treatment value in all four subjects, suggesting improved clinical signs and symptoms. One subject who received clonazepam and another who received botulinum toxin injection showed a remarkable reduction in EMG amplitude within a normal range. Conclusions: Surface EMG can be used to effective evaluate treatment outcomes in patients with oromandibular dystonia. It could be considered as an adjunctive diagnostic tool in managing patients with dystonia.

Effects of Mandibular Midline Shift and Difference of Mandibular Height on the Masticatory Muscle Activity (하악 정중선의 편위와 하악골의 높이차가 저작근 활성에 미치는 영향)

  • Jung, Dae-Yeon;Han, Kyung-Soo;Hyun, Tae-Yeon;Kwag, Dong-Kon
    • Journal of Oral Medicine and Pain
    • /
    • v.26 no.1
    • /
    • pp.75-85
    • /
    • 2001
  • This study was performed to investigate the effect of mandibular midline shift and difference of mandibular height between both sides on the electromyo- graphic(EMG) activity of the masticatory muscles on clenching or gum chewing movement. For this study, 105 patients with temporomandibular disorders(TMD) were selected and panoramic radiograph were taken. Amount and side of the midline shift and height of the mandible from antegonial notch to the top of the condylar head were measured on panoramic view. $BioEMG^{(R)}$ (Bioresearch Inc., Milwaukee, USA) was used for recording of EMG activity(${\mu}V$) of the anterior temporalis and the superficial masseter on clenching or gum chewing movement. EMG activity on clenching during 533msec period were measured for activity of the starting point and the one second-after activity as the early EMG and the maximum EMG, respectively. EMG activity on gum chewing movement were measured for activity of the first and the second chewing stroke. The data collected were analysed by SPSS windows program, and the results of this study were as follows : 1. Height of the mandible was 8.06cm on right side and 8.03cm on left side, and showed no difference by age, but significantly differed by sex with higher in male subjects. 2. Mean value of the midline shift was 0.1mm with range of 0~5mm on both sides. The amount and side of the midline shift did not related with height difference of the mandible and/or the EMG activity of the masticatory muscles on clenching. 3. Prevalence of higher right side and higher left side of the mandible were almost same, and the EMG activity of higher side was not higher than that of the other side. 4. In the subjects with height difference of more than 5mm between both sides of the mandible, the early EMG activity on clenching were differed for the anterior temporalis, but the maximum activity were differed for the superficial masseter. 5. In the subjects with height difference of more than 5mm between both sides of the mandible, EMG activity of the anterior temporalis of the gum chewing side was not higher than that of the other side when chewing on the side of lower height, but in the subjects with height difference of less than 5mm, the EMG activity was higher than that of the other side.

  • PDF