• Title/Summary/Keyword: emergency stairs

Search Result 35, Processing Time 0.027 seconds

Study for Using VR Techniques Performance Evaluation of the Elevator Evacuation (VR기법을 활용한 엘리베이터 피난 성능평가에 관한 연구)

  • Ro, Se-Ho;Yoon, Sung-Wook;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.25 no.1
    • /
    • pp.13-18
    • /
    • 2011
  • In the disaster prevention design, it is important point to secure escape way at event of fire which makes people away from the fire more quickly and safely. Development of construction techniques leads to build many skyscrapers, and skyscrapers contains various dangers and increase levels of disaster. At basic design stage for skyscrapers, evacuation scenario is considered that occupants are escape using escape stairs and emergency elevators simultaneously at fire, but there is no evacuation program to simulate using escape stairs and emergency elevators at the same time. In this study, evacuation simulation is performed using method of VR which is based on Virtools of 3DVIA Co., and Simulex of IES Co. for safety and effectiveness where occupants are escape using escape stairs and emergency elevators simultaneously at the fire.

A Study on the Variation of Evacuation Time according to the Width of Corridor and the Emergency Exit in Gosiwon's Fire State (고시원 화재시 복도 및 비상구 폭에 따른 피난소요시간 변화에 관한 연구)

  • Kim, Jin-Ho;Yang, Jeong-Hoon;Seok, Ho-Tae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.133-138
    • /
    • 2009
  • The purpose of this study is to present an alternative plan in order to reduce the required time to flee from the inside of the gosiwon in danger. The data were derived from changing the width of corridors and emergency exits and the number of stairs in the building EXODUS, which is computer simulation program, The analyzed conclusions from the data are following as below (1) Increasing the exits and the number of stairs are efficient to reduce the accumulated time for standing by. (2) Increasing the number of stairs is efficient to decrease the distance to get out of the building to exit. (3) Increasing the number of stairs is efficient to reduce the time to get out of the building to exit.

  • PDF

A Pilot Study on Environmental Factors Contributing to Childhood Home Slip-Down Injuries (가정 내 낙상으로 인한 아동 손상의 유발 환경 인자에 관한 예비연구)

  • Ryu, Jeong-Min;Seo, Min Hoo;Kim, Won-Young;Kim, Won;Lim, Kyoung-Soo
    • Journal of Trauma and Injury
    • /
    • v.22 no.1
    • /
    • pp.51-56
    • /
    • 2009
  • Purpose: The purpose of this study was to investigate environmental factors contributing to childhood home slip-down injuries. Methods: Among a total of 2,812 injured children in our Customer Injury Surveillance System (CISS), we performed a prospective study on 262 children with home slip-down injuries who visited the pediatric emergency department of Asan Medical Center between March 2008 and February 2009. We made a frequency analysis on parameters such as activities just before the accident, the presence of any obstacles or lubricant materials, specific home place in the home where the injuries occurred, flooring materials on which the slip-down happened, additional objects hit after slip down, the site and kind of injury, the duration of therapy, and the disposition. Results: Walking was the most common activity just before the injury. Because rooms and bathrooms were most common places in the home for slip down injuries, laminated papers/ vinyl floor coverings and tiles were the most common flooring materials used in the places where the injuries occured. Most commonly, no obstacles caused the children to slip down, but the furniture, stairs, doorsills, wetness, or soapy fluid followed after that. Over half of the children who slipped (58%) also collided with other than the floor itself after the slip-down, most common objects hit were the edges of the furniture, and doorsills, followed by stairways. The head and neck were the most commonly injured sites, and a laceration was the most common kind of injury. Most children needed less than 1 week of therapy, only 4 children (1.53%) admitted. There were no mortalities. Conclusion: The environmental factors contributing to slip-down injuries were the bathroom, laminated papers/vinyl floors, the furniture, stairs, doorsills, and wetness or soapy fluid. Especially, the furniture, stairs, and doorsills can be both primary obstacles and secondary collision objects. For the safety of our children, we must consider these factors on housing, when decorating or remodeling our house.

Simulation Analysis of Safety Evacuation in University Experiment Building

  • Tao Zhang;Ha-Sung Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.218-226
    • /
    • 2024
  • According to the actual situation of a university, the emergency evacuation simulation is modeled based on the physical sign, evacuation speed and personnel ratio using the pathfinder software.The experimental construction export utilization rate is compared with the preliminary simulation scenario. The simulation results show that the utilization rate of evacuation stairs and evacuation exits is significantly improved.The optimized solution can provide the most effective evacuation passage, and the research results can provide the basis for the rational planning and management of evacuation passage in university experiment building.

Real-time Fall Detection with a Smartphone (스마트폰을 이용한 실시간 낙상 감지)

  • Hwang, Soo-Young;Ryu, Mun-Ho;Kim, Je-Nam;Yang, Yoon-Seok
    • Journal of Information Technology Services
    • /
    • v.11 no.sup
    • /
    • pp.113-121
    • /
    • 2012
  • In this study, a real-time fall detection system based on a smartphone equipped with three-axis accelerometer and magnetometer was proposed and evaluated. The proposed system provides a service that detects falls in real time, triggers alarm sound, and sends emergency SMS(Short Message Service) if the alarm is not deactivated within a predefined time. When both of the acceleration magnitude and angle displacement of the smartphone attached to waist belt are greater than predefined thresholds, it is detected as a fall. The proposed system was evaluated against activities of daily living(walking, jogging, sitting down, standing up, ascending stairs, and descending stairs) and unintended falls induced by a proprietary pneumatic-powered mattress. With the thresholds of acceleration magnitude 1.7g and angle displacement $80^{\circ}$, it showed 96.5% accuracy to detect the falls while all the activities of daily living were not detected as fall.

Economic and Evacuation Time Analysis of Horizontally-installed Indoor Emergency Exit (하향식 피난구의 경제성 및 피난 소요시간 분석)

  • Liu, Yue;Kim, Sun-Kuk;Kim, Ki-Hyuk;Lee, Dong-Hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.4
    • /
    • pp.363-373
    • /
    • 2018
  • Evacuation facilities are installed so that people can evacuate high-rise apartment houses when it is impossible to escape fire through the front door. The households of apartment houses may escape the building in two ways, which will reduce loss of lives. This study examined the characteristics of two-way evacuation facilities, including a light-weight partition wall, shelter space at the balcony and horizontally-installed indoor emergency exit. Then, it proposed a horizontally-installed outdoor emergency exit that improved the problems of the examined facility types, and analyzed its economic-feasibility. When a horizontally-installed emergency exit instead of a traditional type to escape from fire is used, people may be more autonomous in deciding whether active evacuation is possible or not. Thus, the time required to evacuate the building with 4 different evacuation methods using the stairs and horizontally-installed emergency exit was simulated in consideration of the impact of evacuation methods that people choose on the time required for evacuation using pathfinder. Then, the simulation results were compared and analyzed. Any appropriate evacuation method to reduce the time required for evacuation was predicted, analyzed and decided. As a result of this study, it was analyzed that the high - rise apartment top - down type evacuation zone can shorten the total evacuation time compared to the staircase type.

An Analysis of the Appropriate Number of People Per Apartment Household According to NFPA 101 (NFPA 101에 의한 아파트 한 세대당 적정 수용인원 분석)

  • Cho, Ji-Eun;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.331-337
    • /
    • 2020
  • The study analyzes the appropriate number of people per a household by applying an evacuation simulation to a 27-floor apartment in accordance with the NFPA 101 standard. The results of the analysis are as follows. First, if there are three people residing in each household, there would be 156 households in total, of which 85.25% were evacuated within 5 minutes. Second, 208 households with 4 residents were evacuated within 5 minutes. Third, if there are five people residing in each household, there would be a total of 260 households and 71.92% of residents were evacuated within 5 minutes. Lastly, 62.82% of the 312 households, each consisting of 6 people, were evacuated within 5 minutes. Measures to reduce evacuation time include determining the width of the stairs according to the number of people indoors, the number of floors in the building, the slope of stairs, and the users' characteristics, the design reflecting the ventilation conditions of the stairs, the installment of outdoor evacuation stairs, two-way stairs, evacuation lift, and the installation of an evacuation safety zone for people to evacuate outside of the building in the middle floors. In addition, measures, such as the mandatory installation of automatic emergency door open-close device to the rooftop, are required to facilitate rooftop evacuation.

Preventive Measures of Battery Explosion in Lifeboat (구명정 배터리의 폭발사고 예방을 위한 대안)

  • Im, Myeong-Hwan;Ahn, Byong-Won
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.849-855
    • /
    • 2011
  • Emergency batteries on board are used for stairs, pathway lights, and emergency communications during alternator black-out. In addition, there are engine start-up batteries in lifeboats. Typically, these batteries are installed under the Classification Rules. However, Since batteries inside life boats are installed in a confined narrow space, it is difficult to perform regular maintenances. Also, even though there are air vents in the life boat, the temperature inside the life boat often reaches above $65^{\circ}C$, which is much higher than the regulation temperature, $45^{\circ}C$. In this paper, we will summarize the accident of battery explosion occurred in MMU training ship, and possible causes. We will propose preventive measures of battery explosions as well as the revision of the regulation.

Assessing the risk of work-related musculoskeletal disorders in 119 EMT: a focus on patient-carrying tasks (119구급대원의 업무 관련성 근골격계 질환 위험성 평가 : 환자 운반 작업을 중심으로)

  • Jeong-Won Son
    • The Korean Journal of Emergency Medical Services
    • /
    • v.27 no.3
    • /
    • pp.33-46
    • /
    • 2023
  • Purpose: This study aims to evaluate the risk of work-related musculoskeletal disorders (WMSDs) in 119 EMT during patient-carrying tasks using a long backboard (LBB) and a variable stretcher. Methods: Manikins were used as patients, and 45 new 119 EMT from K Fire Academy were filmed performing patient-carrying tasks on stairs. The tasks were analyzed using Ovako working posture analysis system (OWAS) and Rapid entire body assessment (REBA). Results: In using LBB, the OWAS score was Mode 3(Mean 2.37, Maximum 3), requiring as soon as possible corrective action, the REBA score was Mode 11(Mean 9.16, Maximum 11), requiring immediate improvement. In using variable stretcher, the OWAS score was Mode 1(Mean 2.33, Maximum 3), non-necessity for corrective action, the REBA score was Mode 9(Mean 8.0, Maximum 11), requiring as soon as possible. Conclusion: In conclusion, improvement was needed in one task (carrying a patient using a LBB) in the OWAS and in two tasks (carrying a patient using a LBB, carrying a patient using a variable stretcher) in the REBA. Thereby, required attention and management of WMSDs during training. In addition, it is essential to carry out objective and quantitative assessments through ergonomic analysis by occupational health professionals when designing future training programs to prevent WMSDs.

Bathroom and approach design details evaluated by the elderly in Daejeon city (대전시 거주 노인의 욕실 및 통로공간 디자인에 대한 중요도 평가)

  • 이지숙;박정아
    • Korean Institute of Interior Design Journal
    • /
    • no.41
    • /
    • pp.121-128
    • /
    • 2003
  • This study was purposed to find that the elderly in Daejeon city evaluated design details in bathroom, stairway, entrance etc. On the base of housing expenses and an administrative district, the elderly over 65 were chosen and interviewed by well-trained investigators and 583 case was analyzed through SPSS PC 10.0. The results of this study were as follows ; they said a bathtub was necessary, the floor was not slippery, the height of basin was not high and the grab bar around toilet was not in bathroom and emergency bell was not in house. The elderly pointed out that the non-slip floor, grab bar, bathtub in bathroom and non-slip floor in entrance and stairs should be designed carefully. By the condition of the elderly' health and independent daily living and experience of housing, the evaluation of importance on bathroom and approach design by the elderly were different.