• Title/Summary/Keyword: emergency repair

Search Result 162, Processing Time 0.032 seconds

The Analysis of Emergency Response Guide for Hydrogen Fuel Cell Vehicle (수소연료전지 자동차의 긴급대응 가이드 분석)

  • Lee, Kwang-Ju;Lee, Jong-Tai;Yong, Gee-Joong
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.2
    • /
    • pp.156-161
    • /
    • 2012
  • In case of commercializing of the hydrogen fuel cell vehicle, the suitable emergency response guide is necessary to prepare an accident. In order to suggest the suitable guide for the domestic affairs, the existing external guide about GM, Ford, Honda, and Hyundai was reviewed. The emergency response guides in CAFCP and main FC vehicle makers were included in the analysis. As the results, it was found that the design and make of vehicle for the domestic user are demanded in the emergency response and the guide is made with the shut-down manual picked out for the rescuer and repair man as well as user.

Development of Arm Insulator for Self-Build Based Emergency Tower (긴급복구용 자주조립식 철주 절연암 개발)

  • Min, Byeong-Wook;Wi, Hwa-Bog;Park, Jae-Ung;Lee, Cheol-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.107-108
    • /
    • 2007
  • Overhead transmission lines are completely exposed to the environment. This causes faults in transmission lines due to natural environmental conditions. In some cases, transmission towers are damaged by typhoons and snow, as well as sleet on the transmission lines. It takes a lot of time to repair the damaged towers. For emergency restoration purposes, steel poles are installed to temporarily supply power. Before 2003, emergency restoration steel poles were made of angled steel, which required a large number of beams, bolts, etc. In addition, the foundation of the steel pole and ground wire was constructed using excavation and burial methods, therefore it required a lot of manpower and time to construct temporary transmission lines. In September 2003, typhoon Maemi, whose maximum wind speed was 60m/s, hit Korea. 'Maemi' destroyed transmission lines in the Busan and Geojea area, causing long blackouts. To reduce the recovery time to the damaged transmission lines, self-build based emergency towers were developed. self-build based emergency towers reduced recovery time from 24 hours to 4 hours or less. However, the self-build based emergency tower had no arms, so the temporary transmission lines could only be constructed without curves in line routes. In this paper, solving these self-build based emergency tower limitations, using insulated arms(designed for use with the self-build based emergency tower), shall be explained.

  • PDF

A Study on Repair Case of Journal and Bearing Damage for 25MW Industrial Gas Turbine (25MW급 산업용 가스터빈의 저널과 베어링 손상 보수사례에 관한 연구)

  • Kim, Byung Ok;Sun, Kyung Ho;Lee, An Sung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.6
    • /
    • pp.64-69
    • /
    • 2012
  • This paper deals with the study on repair case of journal shaft and bearing damage in 25MW industrial gas turbine caused by sudden blackout, operation mistake, and logic abnormal, etc. When a serious accident such as journal and bearing damage in a gas turbine occurs, the domestic local companies having the gas turbine are dependent on manufacturer for all maintenance and repair schedule until now. This case study shows that the damaged gas turbine is normally re-operated itself in domestic by establishing repair schedule in a short period of time, repairing damage journal shaft and tilting pad bearings, and performing rotating test for a reliability check. This paper can be regarded as the important case study of emergency test run experience of the refurbished 25MW gas turbine rotor.

Locking horizontal mattress suture as the alternative closure method for scalp lacerations difficult to suture with staple (두피 봉합기로 봉합하기 어려운 두피 열상에 시행한 잠금 수평 매트리스 봉합법의 유용성 관찰 연구)

  • Sah, Seung Woo;Seol, Seunghwan;Lee, Woon Jeong;Woo, Seon Hee;Kim, Dae Hee;Lee, June Young;In, Sangkook;Kim, Bonggyeom
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.6
    • /
    • pp.649-655
    • /
    • 2018
  • Objective: This paper reports the possibility of using of a locking horizontal mattress suture technique in repairing lacerations that are difficult to suture with staples. Methods: Data were collected retrospectively over a 6-month period regarding the routine repair of scalp lacerations: those in areas injured by a high energy blunt mechanism, continued to bleed after pressure, nonlinear or damaged skin repaired with a locking horizontal mattress technique, and simple interrupted technique. The effects of the two techniques used to repair scalp lacerations on wound healing, complication rate, and patient satisfaction were examined. The categorical variables are expressed as the number and percent. A Mann-Whitney-Wilcoxon test was used for statistical analysis. A P-value less than 0.05 was considered significant. Results: Thirty-seven consecutive patients with scalp lacerations presented for care. Wound closure was accomplished with the locking horizontal mattress sutures in 40.5% (n=15) (median length, 5.0 cm; interquartile range [IQR], 4.0-7.0 cm). Simple interrupted sutures (median length, 4 cm; IQR, 3.0-5.0 cm) were used in 59.5% (n=22) (P=0.015). The frequency of additional bandage compression (P=0.008), frequency of exudative hemorrhage (P=0.018), and suture mark frequency at suture removal (P=0.047) were significantly lower in the locking horizontal mattress group. Conclusion: The locking horizontal mattress suture, which has the advantage of a horizontal mattress suture, may be one of the ways that can be used alternatively to treat scalp lacerations that difficult to suture with staples.

SNPs of Excision Repair Cross Complementing Group 5 and Gastric Cancer Risk in Chinese Populations

  • Yang, Wan-Guang;Zhang, Shan-Feng;Chen, Ju-Wu;Li, Li;Wang, Wan-Peng;Zhang, Xie-Fu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.12
    • /
    • pp.6269-6272
    • /
    • 2012
  • We conducted a case-control study to determine the association between several potential SNPs of excision repair cross complementing group 5 (XPG) and gastric cancer susceptibility, and roles of XPG polymorphisms in combination with H.pylori infection in determining risk of gastric cancer. In our study, we collected 337 newly diagnosed gastric cancer cases and 347 health controls. Three SNPs of XPG, rs2296147T>C, rs2094258C>T and rs873601G>A, were genotyped using the Taqman real-time PCR method with a 7900 HT sequence detector system. H. pylori infection was diagnosed by ELISA. By multivariate logistic regression analysis, the rs2296147 CC genotype was associated with a decreased risk of gastric cancer (OR=0.52, 95% CI=0.27-0.97), and rs2094258 TT was associated with elevated risk (OR=2.13, 95% CI=1.22-3.35). Positive H.pylori individuals with rs2094258 TT genotypes demonstrated increased risk of gastric cancer (OR=2.13, 95% CI=1.22-3.35), while rs2296147 CC was associated with lower risk among patients with negative H.pylori (OR=0.45, 95%CI=0.22-0.89). Our findings suggested that XPG polymorphisms might contribute to risk of gastric cancer among Chinese populations, but the effect needs to be further validated by larger sample size studies.

Study of Personal Emergency Response System among Community Residing Elderly (119무선페이징의 이용실태에 관한 연구 - 일 지역을 중심으로 -)

  • Kwon, Hay-Rran;Jung, Ji-Yun;Choi, Gil-Soon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.11 no.2
    • /
    • pp.87-101
    • /
    • 2007
  • Health and disease related characteristics of 226 selected by systematic sampling from 452 personal emergency response system(PERS) beneficiaries and actual conditions of using PERS by them are as follows. Over 86% of PERS beneficiaries have not good health conditions and 70.7% of them have chronic diseases. On social supports family was highest as 52.2% and cases having social workers' assistance were 15.2%, but 53 as 23.7% had not visit or call from anyone and showed very low social supports. 86.2% was given PERS within 3years and 79.1% had it by the recommendation from related agencies and 4.0% was by their demand. On wearing it, 78.3% didn't bring it with them and 92% of them answered they were not sick and then it was found that they didn't use it because they had not special emergency. On satisfaction with paging system's operation, 81.3% answered they were satisfied with it, 48.8% used it for 'acute and emergency diseases' and 29.3% called ambulance for 'appointed medical treatment'. Time required for ambulance to arrive at the field was within 10 min. in 87.8% and after 10 min. in 12.2% and emergency service for beneficiaries by fire service was very good. On satisfaction with use of PERS, 85.4% were satisfied with it, 81.9% who requested repair or replacement of radio paging got it back after one or two days of their request and they answered they were satisfied with A/S. 45.5% answered they powered off it because 'they didn't use it' and 12.1% had 'economical reason of phone charge'.

  • PDF

Emergency Repair Using Cervico-median Sternotomy for Cervicothoracic Penetrating Injury (경흉부 관통상에 대한 경부와 정중흉골절개술을 이용한 치험 1례)

  • Lee, Hyun Joo;Kim, Hyun Koo;Choi, Young Ho
    • Journal of Trauma and Injury
    • /
    • v.21 no.2
    • /
    • pp.136-139
    • /
    • 2008
  • A great variety of penetrating injuries is happening due to the increasing population and violence today. An optimal surgical approach is the key factor for successful repair of a complicated penetrating injury. A 23-year-old woman fell down the stairs from the second floor and received cervico-thoracic penetration injury due to a metalic bar. The metalic bar ruptured the right jugular vein and penetrated the left upper and lower lung. Under cervico-median sternotomy, neck vessels were repaired and the left thorax was successfully entered to repair the damaged lung through the mediastinal pleura. With this approach, the patient's position did not need to be changed during operation, while reduced the operation time compared to the conventional approach (cervical incision and standard thoracotomy).

A Case of Penetrating Facial Wound by a Grinder (분쇄기에 의한 얼굴 관통창 1 례)

  • Kang, Jin-ah;Kim, Kang Ho;Paik, Jin Hui;Hong, Dae Young;Kim, Ji Hye;Lee, Kyoung Mi;Kim, Jun Sig;Han, Seung Baik
    • Journal of Trauma and Injury
    • /
    • v.19 no.1
    • /
    • pp.89-92
    • /
    • 2006
  • Penetrating facial wounds are uncommon and are usually life threatening because of the possibility of brain damage. There are three possible pathways for penetrating the cranium through the orbit: via the orbital roof, via the superior orbital fissure, or between the optic canal and lateral wall of the orbit. Brain injuries resulting from the penetrating wounds show extensive parenchymal damage, hemorrhage, and brain edema. Transorbital penetrating wounds can lead to diverse lesions of the optical apparatus, including the eye globe, the optical nerve, and the chiasm. Moreover, intracerebral structures may be hurt, and bleeding and infection may occur. Early diagnosis and prompt debridement are the fundamental factors affecting the outcome of a penetrating facial wound. An 87-year-old man was admitted to the emergency department with a grinder impacted into the medial aspect of the right eye. On presentation, the man was fully conscious with a Glasgow Coma Scale score of 15 and complained of a visual disturbance of the right eye. Computed tomography demonstrated a right orbital medial and inferior wall fracture, a frontal bone fracture, and a contusional hemorrhage in frontal lobe of the brain. A craniotomy with hematoma removal and repair of the orbital floor was done. He showed no neurological deficits except right visual loss. This appears to be the first report of a man with a penetrating facial wound caused by a grinder, who presented with a potentially disastrous craniocerebral injury that did not lead to any serious neurological seguelae.

Open Surgical Repair Using the Femoral Vein for a Mycotic Superior Mesenteric Artery Aneurysm

  • Namkoong, Min;Hong, Seok Beom;Kim, Hwan Wook;Jo, Keon Hyon;Kim, Jang Yong
    • Journal of Chest Surgery
    • /
    • v.51 no.3
    • /
    • pp.209-212
    • /
    • 2018
  • Superior mesenteric artery (SMA) aneurysms are rare and often fatal. A 72-year-old man had previously been admitted to the emergency room with epigastric pain and heart murmur. The echocardiographic diagnosis was vegetation on the aortic and mitral valves, with moderate regurgitation from both valves due to infective endocarditis. No aneurysm was detected on abdominal computed tomography, and emergency double-valve replacement was performed. On postoperative day 25, the patient experienced abrupt abdominal pain, and computed tomography revealed a mycotic SMA aneurysm. Open surgical repair of the SMA aneurysm was performed using the femoral vein, and the patient's postoperative course was uneventful.

Evaluation of Mechanical Properties and Durability of Fabric Concrete Binder for Emergency Repair (기상재해 대응 긴급보수용 패브릭 콘크리트 혼합물의 역학적 특성 및 내구성능 평가)

  • Jeon, Sang-Min;Jo, Sung-Mun;Oh, Ri-On;Kim, Hwang-Hee;Cha, Sang-Sun;Park, Chan-Gi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.4
    • /
    • pp.23-31
    • /
    • 2020
  • Recently, meteorological disasters have been increasing by climate change, excessive rainfall, and landslide. The purpose is to develop new fabric concrete that can prevent and recover from damages because some of areas are vulnerable to meteorological disaster. Specifically, this technology can minimize time and space constraint when repairing the concrete structure and installing a formwork. The structure of fabric concrete is a mixture of fabric concrete and a high-speed hardened cement, Silica sand, wollastonite mineral fiber, fabric material and waterproof PVC fabric. In this study, the ratio of mechanical properties and durability of the fabric concrete mixture was evaluated by deriving the binder: silica sand mix ratio of the fabric concrete mixture and substituting part of the cement amount with wollastonite mineral fiber. Best binder in performance evaluation: Silica sand mix ratio is 6: 4 and the target mechanical performance and durability are the best when over 15% wollastonite binder is replaced by silicate mineral fiber.