• Title/Summary/Keyword: embedded testing

Search Result 411, Processing Time 0.022 seconds

Optimal Heating Location for developing the Heating Smart Clothing based on Thermal Response of Body (발열 기능 스마트 의류를 위한 인체 온열반응 기반의 최적의 발열위치 연구)

  • Cho, Hakyung;Cho, Sangwoo
    • Science of Emotion and Sensibility
    • /
    • v.18 no.3
    • /
    • pp.93-106
    • /
    • 2015
  • In accordance with escalating demands for advanced technology products, the smart clothing that includes embedded ICT technology have expanded into fields of daily life. As a result of this trend, interest in smart clothing with digitally controllable heating has rapidly grown and the market for smart heated clothing has also expanded. Increasing of prospect in smart heated clothing market, the effectiveness and thermal sensation research of the location on the pad attached is insufficient. This study was conducted to find the optimal location of heated clothing via experimental research on changes in skin temperature and subjective thermal sensation when heating pads were placed on different areas of the body. For this experiment, the subjects consisted of 10 males in their 20's of standard physique. The skin temperature at 11 different areas of the body, rectal temperature, and subjective thermal sensation were taken at different stages (before testing, after a 20 minute rest period, 20 minute treatment period, and after a 40 minute recovery period) in an artificial-climate chamber at $-5^{\circ}C$. As a result, the optimal location for heating pads in smart clothing was estimated and suggested.

Effect of Lateral Load-Moment Combination on p-y Curves of Large Diameter Monopile for Offshore Wind Turbine: Centrifuge Model Tests (해상풍력 대구경 모노파일의 p-y 곡선에 대한 수평-모멘트 조합의 영향: 원심모형실험)

  • Lee, Min Jy;Yun, Jong Seok;Choo, Yun Wook
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.2
    • /
    • pp.29-42
    • /
    • 2020
  • In this study, centrifuge tests were performed to investigate the effect of the lateral load-moment combination on the p-y curves for 7 m-diameter monopiles installed in sand for offshore wind turbine. For the objectives, a centrifuge testing system was developed and tests were conducted at an acceleration of 68.83 g using well-instrumented model monopiles under two different lateral load-moment combinations simulated by different loading heights: 1 and 5 times monopile diameter from the ground surface. The sand was prepared as medium loose sand. Based on the centrifuge test results, the experimental p-y curves were evaluated and compared with previous literatures including API codes. The experimental results reveal that the p-y curves were little influenced by the combination of lateral load and moment. It was also found that the embedded length affects p-y curves.

Comparison of changes in retentive force of three stud attachments for implant overdentures

  • Kim, Su-Min;Choi, Jae-Won;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.4
    • /
    • pp.303-311
    • /
    • 2015
  • PURPOSE. The aim of this study was to compare the changes in retentive force of stud attachments for implant overdentures by in vitro 2-year-wear simulation. MATERIALS AND METHODS. Three commercially available attachment systems were investigated: Kerator blue, O-ring red, and EZ lock. Two implant fixtures were embedded in parallel in each custom base mounting. Five pairs of each attachment system were tested. A universal testing machine was used to measure the retentive force during 2500 insertion and removal cycles. Surface changes on the components were evaluated by scanning electron microscopy (SEM). A Kruskal-Wallis test, followed by Pairwise comparison, was used to compare the retentive force between the groups, and to determine groups that were significantly different (${\alpha}$<.05). RESULTS. A comparison of the initial retentive force revealed the highest value for Kerator, followed by the O-ring and EZ lock attachments. However, no significant difference was detected between Kerator and O-ring (P>.05). After 2500 insertion and removal cycles, the highest retention loss was recorded for O-ring, and no significant difference between Kerator and EZ lock (P>.05). Also, Kerator showed the highest retentive force, followed by EZ lock and O-ring, after 2500 cycles (P<.05). Based on SEM analysis, the polymeric components in O-ring and Kerator were observed to exhibit surface wear and deformation. CONCLUSION. After 2500 insertion and removal cycles, all attachments exhibited significant loss in retention. Mechanism of retention loss can only be partially explained by surface changes.

Detection of tension force reduction in a post-tensioning tendon using pulsed-eddy-current measurement

  • Kim, Ji-Min;Lee, Jun;Sohn, Hoon
    • Structural Engineering and Mechanics
    • /
    • v.65 no.2
    • /
    • pp.129-139
    • /
    • 2018
  • Post-tensioning (PT) tendons are commonly used for the assembly of modularized concrete members, and tension is applied to the tendons during construction to facilitate the integrated behavior of the members. However, the tension in a PT tendon decreases over time due to steel corrosion and concrete creep, and consequently, the stress on the anchor head that secures the PT tendon also diminishes. This study proposes an automatic detection system to identify tension reduction in a PT tendon using pulsed-eddy-current (PEC) measurement. An eddy-current sensor is installed on the surface of the steel anchor head. The sensor creates a pulsed excitation to the driving coil and measures the resulting PEC response using the pick-up coil. The basic premise is that the tension reduction of a PT tendon results in stress reduction on the anchor head surface and a change in the PEC intensity measured by the pick-up coil. Thus, PEC measurement is used to detect the reduction of the anchor head stress and consequently the reduction of the PT tendon force below a certain threshold value. The advantages of the proposed PEC-based tension-reduction-detection (PTRD) system are (1) a low-cost (< $ 30), low-power (< 2 Watts) sensor, (2) a short inspection time (< 10 seconds), (3) high reliability and (4) the potential for embedded sensing. A 3.3 m long full-scale monostrand PT tendon was used to evaluate the performance of the proposed PTRD system. The PT tendon was tensioned to 180 kN using a custom universal tensile machine, and the tension was decreased to 0 kN at 20 kN intervals. At each tension, the PEC responses were measured, and tension reduction was successfully detected.

Differences in Epidermal Growth Factor Receptor Gene Mutations and Relationship with Clinicopathological Features in NSCLC Between Uygur and Han Ethnic Groups

  • Zhang, Yan;Wang, Qiang;Han, Zhi-Gang;Shan, Li
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.5
    • /
    • pp.2879-2883
    • /
    • 2013
  • Objective: To investigate differences in mutations of epidermal growth factor receptor (EGFR) gene and relationships with clinicopathological features in patients with non-small cell lung cancer (NSCLC) between Uygur and Han ethnic groups. Methods: The Scorpions amplification refractory mutation system (Scorpions ARMS) was used to measure mutations in exons 18, 19, 20 and 21 of the EGFR gene in paraffin-embedded tumor tissue from NSCLC cases, and statistical analysis was performed to investigate links with clinicopathological features in different histological types of NSCLC. Results: Results from ARMS testing showed EGFR mutations in tumor tissues from six (6) of 50 NSCLC patients of Uygur ethnic group, with a positive rate of 12.0%; four of them (4) had exon 19 deletion in EGFR, and two (2) had L858R point mutation in exon 21 of EGFR. Statistically significant difference was noted in EGFR genetic mutation between adenocarcinoma and non-adenocarcinoma (P < 0.05), but no differences with gender, age group, smoking status, or stage (P > 0.05). EGFR mutations were detected in tumor tissues from 27 of 49 NSCLC patients of Han ethnic group, with a positive rate of 55.1%; 19 of them had exon 19 deletions, seven (7) had L858R point mutations in exon 21 of EGFR and one (1) had mutations in both exon 18 G719X and exon 20 T790M of EGFR. Statistically significant differences were noted in EGFR genetic mutations between genders and between adenocarcinoma and non-adenocarcinoma (P<0.05), but not with age group, smoking status, or stage (P > 0.05). Conclusion: Statistically significant differences were noted in the positive rates of EGFR genetic mutations in NSCLC patients between Uygur and Han ethnic groups, with lower positive rates for the Uygur cases.

The signal processing algorithm of the Missile Flight Test Launch Control System (비행시험 발사통제 시스템의 신호처리 알고리즘)

  • Oh, Jino
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.8
    • /
    • pp.1965-1972
    • /
    • 2015
  • The Missile Flight Test Launch Control System is to operate in conjunction with the Fire Control System during flight test to guided weapons. Also, this is a system for the test control and situation monitoring depending on the type of guided weapons and testing purposes. Message structure, communication protocols, such as data types for interworking with the fire control system and the Missile Flight Test Launch Control System are defined in the Launch Control ICD(Interface Control Document). ICD are composed differently of each guided weapons system and each test object. Previously, in order to interwork with the Fire Control System, the interlocking software was developed, which had a variety of problems. Therefore, we developed a new parsing algorithm in order to recognize the variety of Launch Control ICD and verified that the algorithm operates normally by checking transmitting and receiving various message in conjunction with the fire control system.

An Experimental Study on Principal Factors for Non-destructive Test of Detecting Steel bars (비파괴 철근탐사의 주요 영향인자에 관한 실험적 연구)

  • Oh, Kwang Chin;Kim, Jong Ho;Rhee, Jong Woo;Lee, Yun Hyang
    • Journal of Korean Society of societal Security
    • /
    • v.3 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • Detecting rebars in side the concrete structures is one of the important steps in assessing condition of the structure. In order to determine the detection capability of locating rebars inside the concrete, two types of equipments, which use radar system and electromagnetic system each, were tested. Four concrete specimens which have the dimensions of $1,000mm(length){\times}300mm(width)$ with different thickness and diameter of steel bars were applied. A series of testing was achieved after drying in air for 90 days, immersed in water for 3, 24, 48 hour and 28 day. From the experimental outcome, it is shown that error is increased as the diameter of rebar enlarge in case of electromagnetic method. In case of radar method, the detection of embedded rebars in deep is good in the view of reliability. As moisture content increase from 3.6% to 5.5%, the relative permittivity of concrete test specimens show tendency to increase, too. Therefore, it is shown that moisture content is one of the major contributing factors to determine the relative permittivity. And the relative permittivity regression equation is suggested.

  • PDF

Tensile bond strength between auto-polymerized acrylic resin and acrylic denture teeth treated with MF-MA solution

  • Thongrakard, Ticha;Wiwatwarrapan, Chairat
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.4
    • /
    • pp.285-289
    • /
    • 2016
  • PURPOSE. This study evaluated the effect of chemical surface treatment using methyl formate-methyl acetate (MF-MA) solution on the tensile bond strength between acrylic denture teeth and auto-polymerized acrylic resin. MATERIALS AND METHODS. Seventy maxillary central incisor acrylic denture teeth for each of three different brands (Yamahachi New Ace; Major Dent; Cosmo HXL) were embedded with incisal edge downwards in auto-polymerized resin in polyethylene pipes and ground with silicone carbide paper on their ridge lap surfaces. The teeth of each brand were divided into seven groups (n=10): no surface treatment (control group), MF-MA solution at a ratio of 25:75 (v/v) for 15 seconds, 30 seconds, 60 seconds, 120 seconds, 180 seconds, and MMA for 180 seconds. Auto-polymerized acrylic resin (Unifast Trad) was applied to the ground surface and polymerized in a pressure cooker. A tensile strength test was performed with a universal testing machine. Statistical analysis of the results was performed using two-way analysis of variance (ANOVA) and post-hoc Dunnett T3 test (${\alpha}$=.05). RESULTS. The surface treatment groups had significantly higher mean tensile bond strengths compared with the control group (P<.05) when compared within the same brand. Among the surface treatment groups of each brand, there were no significantly different tensile bond strengths between the MF-MA groups and the MMA 180 second group (P>.05), except for the Yamahachi New Ace MF-MA 180-second group (P<.05). CONCLUSION. 15-second MF-MA solution can be an alternative chemical surface treatment for repairing a denture base and rebonding acrylic denture teeth with auto-polymerized acrylic resin, for both conventional and cross-linked teeth.

Shear Bond Strength of Porcelain Repair Systems (도재 수리 시스템의 전단결합강도에 관한 연구)

  • Woo, Soo;Shin, Soo-Youn;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.3
    • /
    • pp.211-220
    • /
    • 2006
  • Need of porcelain-repair system is largely demanding as dental porcelain restorations are increased in clinical dentistry. This study investigated shear bond strength of commercial porcelain-repair systems on dental porcelain and their reliability. Experimental groups were as follows; Group A Super Bond C&B, Group B Porcelain repair kit, Group C Ceramic repair, and Group D Spectrum system as a control. Porcelain disks were fired and embedded in epoxy resin. Porcelain surface were ground using 220 grit SiC disk, then cleaned in ultrasonic bath. Then porcelain specimens were treated with each repair system. A clear polystyrene cylinder 3.5 mm in internal diameter was filled with composite resin. Then the resin cylinder was polymerized with a visible light curing unit. Thirty one specimens at each group were prepared and stored at $37^{\circ}C$ distilled water for 48 h. Specimens were tested in an Instron testing machine according to ISO TR 11405. Mean shear bond strength and standard deviation of each group was $15.7{\pm}4.1MPa$ (Group A), $12.8{\pm}4.9MPa$ (Group B), $7.2{\pm}3.0MPa$ (Group C) and $9.6{\pm}2.2MPa$ (Group D). ANOVA and Tukey HSD post-hoc test showed that there were significant differences between groups (p<0.05). Data of bond strength were analyzed with two-parameter Weibull distribution. Confidence interval of Weibull modulus (m-parameter) at 95% of Group A (3.5-6.3) and Group D (3.6-6.0) were significantly higher than Group B (2.2-3.7) and Group C (2.0-3.4). There was little correlation between mean shear bond strength and Weibull modulus. Results indicated that acid-etching of porcelain surface increased porcelain-resin shear bonding strength.

Resin bonding of metal brackets to glazed zirconia with a porcelain primer

  • Lee, Jung-Hwan;Lee, Milim;Kim, Kyoung-Nam;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.45 no.6
    • /
    • pp.299-307
    • /
    • 2015
  • Objective: The aims of this study were to compare the shear bond strength between orthodontic metal brackets and glazed zirconia using different types of primer before applying resin cement and to determine which primer was more effective. Methods: Zirconia blocks were milled and embedded in acrylic resin and randomly assigned to one of four groups: nonglazed zirconia with sandblasting and zirconia primer (NZ); glazed zirconia with sandblasting, etching, and zirconia primer (GZ); glazed zirconia with sandblasting, etching, and porcelain primer (GP); and glazed zirconia with sandblasting, etching, zirconia primer, and porcelain primer (GZP). A stainless steel metal bracket was bonded to each target surface with resin cement, and all specimens underwent thermal cycling. The shear bond strength of the specimens was measured by a universal testing machine. A scanning electron microscope, three-dimensional optical surface-profiler, and stereoscopic microscope were used to image the zirconia surfaces. The data were analyzed with one-way analyses of variance and the Fisher exact test. Results: Group GZ showed significantly lower shear bond strength than did the other groups. No statistically significant differences were found among groups NZ, GP, and GZP. All specimens in group GZ showed adhesive failure between the zirconia and resin cement. In groups NZ and GP, bonding failed at the interface between the resin cement and bracket base or showed complex adhesive and cohesive failure. Conclusions: Porcelain primer is the more appropriate choice for bonding a metal bracket to the surface of a full-contour glazed zirconia crown with resin cement.